Search PubMed⌕ Search

PubMed · 10120060

Technical note: preventive maintenance quality assurance.

Abstract

Performance improvements in healthcare and, specifically, in clinical engineering are required by the Joint Commission on the Accreditation of Healthcare Organizations' Plant Technology and Safety Management (PTSM) documents. The goals of healthcare service quality assurance are to establish performance requirements and improve patient outcomes. It is important that these goals be kept in the forefront of the design of clinical engineering quality assurance planning. Indicator/threshold pairs must be carefully chosen on the basis of some logical relation to the desired goals of the overall program.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Russell. Technical note: preventive maintenance quality assurance.. https://doi.org/10.1097/00004669-199207000-00012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗