Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Litvin. 1992. Implementing cardiac catheterization services: a case study.. https://pubmed.ncbi.nlm.nih.gov/10117665/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Surgical validation and implications for transcatheter closure of quantitative echocardiographic evaluation of atrial septal defect.

Accurate evaluation of secundum atrial septal defect (ASD) is important for the success of transcatheter closure. The purpose of this study was (1) to describe a quantitative evaluation by transthoracic (TTE) and transesophageal (TEE) echocardiography of the various morphologic features of ASD that might be important for patient selection for transcatheter closure, and (2) to assess the reliability of these 2 methods by surgical findings. Preoperative TTE and TEE were used to evaluate the ASD of 27 children undergoing surgical closure. Measurements included the diameters of ASD and the atrial septal lengths in the transverse and longitudinal axis, and the width of the superior, inferior, anteroinferior, and posterior septal margins. The shape and location of the ASD and the adequacy of the septal margins for anchoring occluding devices were determined. Echocardiographic data were compared with corresponding surgical measurements. No significant difference occurred in the means of all the parameters measured with the 3 methods, except for the transverse ASD diameter (p <0.05). Good agreement occurred between TTE and TEE and surgical data, except for the transverse ASD diameter, transverse atrial septal length, and the posterior septal margin on TTE. Intraclass correlations between TTE and TEE and surgical measurements of all parameters were good, except for the transverse ASD diameter. The accuracy in determining shape and location of the ASD by TTE and TEE were 100%, whereas that for determining the adequacy of septal margins was 98% and 97%, respectively. In conclusion, TTE and TEE are reliable methods for quantitative evaluation of ASD.

Cardiac Catheterization

Prognostic usefulness of the tricuspid annular plane systolic excursion in patients with congestive heart failure secondary to idiopathic or ischemic dilated cardiomyopathy.

The prognostic value of ultrasound evaluation of right ventricular (RV) performance in patients with congestive heart failure (CHF) is still a matter of investigation. We studied 140 consecutive patients with chronic CHF and a left ventricular ejection fraction <35%. All patients underwent a complete echocardiographic evaluation that systematically included the measurement of the tricuspid annular plane systolic excursion (TAPSE). During a follow-up period of 24 +/- 14 months, 45 patients died and 7 underwent emergency heart transplantation. At the multivariate survival analysis (Cox regression model) backward stepwise selection identified a prognostic model with 2 parameters: New York Heart Association (NYHA) class III or IV and TAPSE < or =14 mm (p <000). In a subgroup of 97 patients in sinus rhythm in whom mitral inflow Doppler variables could be measured, survival was further analyzed according to a model in which the significant parameters were included in the same order as usually used in routine clinical practice: clinical variables first, left ventricular function data second, mitral Doppler variables third, and indexes of right ventricular (RV) function last. TAPSE < or =14 mm added significant (p <0.03) prognostic information to NYHA class III or IV, left ventricular ejection fraction of <20%, and mitral deceleration time of < 125 ms. In conclusion, in patients with CHF, TAPSE adds significant prognostic information to the NYHA clinical classification, to the echocardiographic evaluation of left ventricular function, and to mitral Doppler variables. Furthermore, the measurement of TAPSE is easy to obtain in all patients, irrespective of heart rate and rhythm.

Cardiac Catheterization