Search PubMedSearch

PubMed · 10022666

Bismuth binds...

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Surawicz. 1999. Bismuth binds.... https://doi.org/10.1111/j.1572-0241.1999.00535.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Long-term evaluation of the influence of smear layer removal on the sealing ability of different sealers.

The purpose of this study was to examine the effect of the smear layer on apical microleakage over 16 wk. One hundred and four extracted human teeth were assigned to four groups treated as follows: group A1--smear layer was left intact and canals were obturated with gutta-percha and Roth 811; group A2--smear layer was left intact and canals were obturated with gutta-percha and AH26; group B1--smear layer was removed and canals were obturated with gutta-percha and Roth 811; and group B2--smear layer was removed and canals were obturated with gutta-percha and AH26. Microleakage was measured by the electrochemical method. In parallel, 12 teeth were examined under a scanning electron microscope. The results indicated that the smear layer removal resulted in a statistically significant reduction of microleakage values in groups obturated with AH26. The presence or absence of smear layer had no significant effect on the sealing ability of Roth 811.

Bismuth

Dentinal tubule penetration of root canal sealers after root canal dressing with calcium hydroxide.

The purpose of this study was to evaluate the dentinal tubule penetration of root canal sealers after root canal dressing with calcium hydroxide (Ca(OH)2). Forty-two single-rooted teeth were instrumented to size 60. Six teeth served as the control group, and the remaining teeth were assigned to two groups. Root canals of the first group were filled with the Ca(OH)2 paste; the second group was filled with TempCanal, and all were incubated for 7 days. The samples were either irrigated with only NaOCl or with EDTA, followed by NaOCl to remove Ca(OH)2. All of the teeth were obturated with CRCS, AH26, and Ketac Endo by a lateral condensation technique. The specimens were then kept at the same conditions for another 7 days, and then all of the roots were prepared for scanning electron microscopic evaluation. Scanning electron microscopic examination revealed that Ca(OH)2 was not completely removed from the root canal surfaces, and root canal sealers did not penetrate into the dentinal tubules when only NaOCl was used. EDTA followed by NaOCl irrigation resulted in complete removal of Ca(OH)2 and root canal sealers penetrated into the dentinal tubules.

Bismuth

Obturation of root canals with different sealers using non-instrumentation technology.

AIM: To evaluate and compare the sealing quality of hand- or vacuum-obturated root canals after hand preparation or hydrodynamic cleansing of root canals, respectively. METHODOLOGY: After assessing root curvature, 96 single-rooted deep-frozen teeth were divided into eight comparable groups. The root canals of four groups were instrumented with the balanced force technique. The remaining uninstrumented teeth were connected to a reduced-pressure device (NIT) and the root-canal system perfused with 2.5% NaOCl under alternating pressure fields. This dissolved the pulpal tissues and removed debris from the root-canal system. The canals of the hand-instrumented groups were obturated using the cold lateral condensation method with guttapercha and one of four different sealers (AH26, AH Plus, Apexit and Pulp Canal Sealer EWT). The teeth treated with the alternating pressure device (NIT) were obturated by a vacuum obturation method (NIT) with the same four sealers. The quality of the coronal seal was assessed using a dye penetration method. In order to minimize errors the roots were perfused with water before exposure to the dye, under vacuum. The teeth were then rendered transparent and the depth of penetration of the dye between the wall of the canal and the obturating material was measured with a stereomicroscope. RESULTS: The canals cleaned and filled by NIT showed statistically significantly less dye penetration than those obturated by lateral condensation (P < 0.05). Within the NIT group, Pulp Canal Sealer EWT exhibited significantly more dye penetration than Apexit. Amongst the control lateral condensation groups no significant differences were found between the various sealers. CONCLUSIONS: The present investigation demonstrated the validity of the NIT obturation method in combination with commonly used root-canal sealers.

Bismuth