Search PubMedSearch

subject

Injections, Subcutaneous

Injections, Subcutaneous: explore 4 source-linked works published from 2026 to 2026, with original documents and citations.

This collection is a preview while coverage and quality are evaluated.

Search within this collection

Coverage and selection

Includes records with this source-supplied label or an explicit phrase match in their metadata. Matches indicate a mention, not proof that a paper uses a method or tests a material. Source versions are consolidated by DOI.

Sources: pubmed. Collection updated 2026-09-15. Counts describe this index, not the complete source archives.

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

A phase I clinical study of the safety, tolerability, pharmacokinetics and pharmacodynamics of SHR-2106, an anti-CD40 antibody, following single intravenous or subcutaneous administration in healthy participants.

BACKGROUND: SHR-2106 is a humanized IgG1 monoclonal antibody that blocks CD40-CD40L interactions and has demonstrated immunosuppressive activity and graft-prolonging effects in preclinical studies. This first-in-human Phase I study evaluated the safety, pharmacokinetics, pharmacodynamics, and immunogenicity of single intravenous or subcutaneous doses of SHR-2106 in healthy adults. METHODS: This randomized, double-blind, placebo-controlled Phase I study enrolled healthy participants. Fifty-one participants were enrolled in seven cohorts and received five intravenous doses (50-1200 mg) or two subcutaneous doses (300 and 600 mg). Safety, serum pharmacokinetics, CD40 occupancy on B cells, and anti-drug antibodies were assessed using standard clinical and bioanalytical methods. RESULTS: SHR-2106 demonstrated a favorable safety and tolerability profile, and most treatment-emergent adverse events were mild to moderate laboratory abnormalities with incidence rates comparable to placebo. SHR-2106 exhibited nonlinear pharmacokinetics consistent with target-mediated drug disposition, with a dose-dependent increase in geometric mean terminal half-life following intravenous administration (1.83-10.7 days). Absolute bioavailability after subcutaneous administration was approximately 60%. CD40 occupancy exceeded 80% within 24 h at all doses, with saturation duration increasing from 7 to 70 days across the intravenous dose range and remaining comparable between routes at matched doses. Anti-drug antibody incidence decreased with increasing intravenous dose and did not significantly affect pharmacokinetics or pharmacodynamics. CONCLUSION: SHR-2106 was well tolerated and achieved rapid and sustained CD40 engagement, supporting dose and route selection for Phase II studies.

Humans

Characterization of local tolerability of TV-46000, a long-acting subcutaneous formulation of risperidone for the treatment of schizophrenia.

TV-46000 is a long-acting injectable antipsychotic (LAI) approved for the treatment of adults with schizophrenia and bipolar I disorder. LAIs like TV-46000 can improve adherence and reduce relapse in patients with schizophrenia; however, injection site reactions (ISRs) can contribute to LAI discontinuation. ISRs with TV-46000 treatment were characterized using data from two phase 3 trials of patients with schizophrenia (RISE [NCT03503318], SHINE [NCT03893825]) and a phase 1 study of patients with schizophrenia or schizoaffective disorder. Patients in the pooled safety population (aged 16-67 years) from RISE and SHINE (n = 525 TV-46000, n = 179 placebo) received 4554 TV-46000 injections and 2721 placebo injections. ISRs were reported in 19 % (n = 102) of patients who received TV-46000, corresponding to an exposure-adjusted event rate (EAER)/100 patient-years of 48.67. ISRs led to 9 (1.7 %) treatment discontinuations of TV-46000. The most frequently reported ISR adverse events were injection site pain (EAER, 15.38, n = 36 [7 %]) and injection site nodule (EAER, 12.01, n = 35 [7 %]). ISR frequency and pain and nodule adverse event frequency decreased after the first injection. In the phase 1 study (n = 99), mean injection site pain scores were highest immediately after injection, showed a notable decrease within 10 min of injection, and further decreased within 1 h after injection. In conclusion, for >4500 injections evaluated, ISR rates with TV-46000 were modest. Most ISRs were mild or moderate and rarely led to treatment discontinuation. Results support the favorable tolerability of TV-46000 as a treatment for schizophrenia in adults.

Humans

The effect of zalunfiban on high sensitivity cardiac troponin and the association with clinical outcomes in patients with STEMI.

BACKGROUND: Among individuals with ST-segment elevation myocardial infarction (STEMI), a single subcutaneous injection of the short-acting glycoprotein IIb/IIIa receptor blocker antagonist zalunfiban at first medical contact significantly improved the primary outcome including clinical endpoints. The impact of zalunfiban on Myocardial Infarction (MI) size and association with downstream outcomes remains unclear. METHODS: In a prespecified analysis, we studied results among study participants treated with 2 doses of zalunfiban who had core laboratory measurements concentrations of hs-cTnT. RESULTS: More elevated hs-cTnT concentrations at presentation were associated with less resolution of ST deviation (P = .006) and more frequent Q wave development (P < .001). At coronary angiography more elevated hs-cTnT at presentation was associated with higher thrombus grade and worse epicardial and myocardial perfusion (all P < .05). In multivariable analyses, higher hs-cTnT concentrations at 24 hours were associated with greater adjusted risk for all-cause death (odds ratio [OR] 1.83 per log unit increase; P = .03), cardiovascular death (OR 1.83 per log unit increase; P = .03), heart failure (OR 2.74 per log unit increase; P < .001) or the composite of death and heart failure (P < .001) by 30 days. At 24 hours, those treated with zalunfiban had lower hs-cTnT compared to placebo (P = .04) and across multiples &#x2265; 10 to &#x2265; 1,000 times elevation, treatment with zalunfiban resulted in smaller hs-cTnT determined MI size. CONCLUSIONS: Among patients with STEMI, more elevated concentrations of hs-cTnT are associated with worse measures of reperfusion and higher-risk for short-term death or heart failure. A single dose of zalunfiban at first medical contact reduced MI size. TRIAL REGISTRATION: A phase 3 study of zalunfiban in subjects with ST-elevation MI (CELEBRATE); NCT04825743.

Humans
Compare source metadata on this page

These are bibliographic comparisons, not experimental rankings. Follow the original document for methods and conditions.