Search PubMed⌕ Search

Biomedical subjects

Zeynep Tartan

Publications and source records attributed to Zeynep Tartan.

20 records · Page 2Linked to original sources

Cardiac troponin I increase after successful percutaneous coronary angioplasty: predictors and long-term prognostic value.

After successful percutaneous coronary interventions (PCI), elevations of cardiac enzymes are not rare, but it is still not clear whether those elevations are associated with adverse late outcome. The purpose of the study was to investigate the relation between cardiac troponin I (cTn-I) increase after successful percutaneous intervention and late outcome. The study consisted of 100 consecutive patients (mean age 56 +/-9.8, 84% male) who had successful elective coronary balloon angioplasty with or without stent implantation. Patients with stable angina (n=54) and unstable angina (n=46) were included in the study. Blood samples for measurement of cTn-I were taken before and immediately after the procedure, and every 6 hours for the first 24 hours. Patients with preprocedural cTn-I elevation were excluded from the study. Postprocedural cTn-I elevation was detected in 34 patients (34%, troponin (+) group) and cTn-I levels were normal in 66 patients (66%, troponin (-) group). Logistic regression analysis showed that intervention in patients with unstable angina, stent implantation following balloon dilation, and maximal inflation pressure were the predictors of cTn-I elevation (p=0.035, p=0.038, and p=0.014, respectively). During the prospective follow-up period for 21 +/-7.5 months, the incidence of major cardiac events including recurrent angina, acute myocardial infarction, death, and revascularization were not different in patients with and without cTn-I elevation. Overall, major cardiac events occurred in 9 patients (26%) in the troponin (+) group and in 13 patients (20%) in the troponin (-) group. Kaplan-Meier survival analysis showed that cTn-I elevation was not an important correlate of overall cardiac events (log-rank: 1.66, p=0.19). The authors conclude that postprocedural cTn-I elevation is related to unstable angina, stent implantation following predilation, and inflation pressure, and there is no association with minor myocardial injury occurring after successful percutaneous coronary intervention and late adverse cardiac events.

Angina Pectoris↗

Impacts of glycoprotein IIb/IIIa inhibition on QT dispersion after successful percutaneous coronary intervention.

Coronary ischemia augments inhomogeneity in ventricular repolarization. Decrease in the QT dispersion (QTd) following restoration of coronary blood flow to the ischemic myocardium by successful percutaneous coronary intervention (PCI) is an expected outcome. The purpose of the study was to seek whether glycoprotein IIb/IIIa (GP IIb/IIIa) inhibition has additional beneficial effects on QT dispersion after angiographically successful PCI. The study involved 111 consecutive patients scheduled for elective coronary balloon angioplasty with or without stent implantation. Sixty patients (mean age 58 +/-9) were randomized to receive standard therapy including preprocedural aspirin, ticlopidine, and IV heparin, and 51 patients (mean age 54 +/-10) were randomized to receive additional IV tirofiban infusion before the lesion was crossed with the guidewire. Standard 12-lead simultaneous ECG recordings for the measurement of QTd and corrected QTd (QTcd) (calculated by using Bazett's formula) were obtained before and immediately after the procedure, and at the 6th, and 24th hours. Blood samples for detection of postprocedural myocardial damage (CK-MB and cTn-I) were taken before and immediately after the procedure, at the 6th, 12th, and 24th hours. In total, 128 stenoses were treated with PCI. Seventy of these lesions were in the standard therapy group and 58 in the tirofiban group. QTd and QTcd were not statistically different between the 2 groups before and immediately after the procedure and at the 6th hours, but at the 24th hour QTd and QTcd were significantly longer in the standard therapy group (p=0.047 and p=0.001, respectively). Postprocedural troponin-I elevation (B=0.692, p=0.037), maximum inflation pressure (B=0.182, p=0.001), and previous myocardial infarction (MI) (B=0.885, p=0.004) were defined as the predictors of the final QT dispersion at the 24th hour. QT dispersion significantly decreased after successful percutaneous coronary intervention. GP IIb/IIIa inhibition therapy was not superior by means of recovery of increased QT dispersion during the early hours of the intervention, but it prevented minor myocardial necrosis and provided more long-lasting recovery in QT dispersion as compared with heparin therapy. This impact of GP IIb/IIIa receptor inhibition on QTd may be a possible mechanism by which these drugs reduce cardiovascular events after PCI.

Angioplasty, Balloon, Coronary↗