Search PubMed⌕ Search

Biomedical subjects

Z P Liang

Publications and source records attributed to Z P Liang.

At least 19 recordsLinked to original sources

A bound on mutual information for image registration.

An upper bound is derived for the mutual information between a fixed image and a deformable template containing a fixed number of gray-levels. The bound can be calculated by maximizing the entropy of the template under the constraint that the conditional entropy of the template, given the fixed image, be zero. This bound provides useful insight into the properties of mutual information as a similarity metric for deformable image registration. Specifically, it indicates that maximizing mutual information may not necessarily produce an optimal solution when the deformable transform is too flexible.

Image Processing, Computer-Assisted↗

fMri studies of Stroop tasks reveal unique roles of anterior and posterior brain systems in attentional selection.

The brain's attentional system identifies and selects information that is task-relevant while ignoring information that is task-irrelevant. In two experiments using functional magnetic resonance imaging, we examined the effects of varying task-relevant information compared to task-irrelevant information. In the first experiment, we compared patterns of activation as attentional demands were increased for two Stroop tasks that differed in the task-relevant information, but not the task-irrelevant information: a color-word task and a spatial-word task. Distinct subdivisions of dorsolateral prefrontal cortex and the precuneus became activated for each task, indicating differential sensitivity of these regions to task-relevant information (e.g., spatial information vs. color). In the second experiment, we compared patterns of activation with increased attentional demands for two Stroop tasks that differed in task-irrelevant information, but not task-relevant information: a color-word task and color-object task. Little differentiation in activation for dorsolateral prefrontal and precuneus regions was observed, indicating a relative insensitivity of these regions to task-irrelevant information. However, we observed a differentiation in the pattern of activity for posterior regions. There were unique areas of activation in parietal regions for the color-word task and in occipitotemporal regions for the color-object task. No increase in activation was observed in regions responsible for processing the perceptual attribute of color. The results of this second experiment indicate that attentional selection in tasks such as the Stroop task, which contain multiple potential sources of relevant information (e.g., the word vs. its ink color), acts more by modulating the processing of task-irrelevant information than by modulating processing of task-relevant information.

Adult↗

Lactate quantitation in a gerbil brain stroke model by GSLIM of multiple-quantum-filtered signals. Generalized spectral localization by imaging.

Quantitative magnetic resonance imaging of lactate using a zero-quantum/double-quantum filter and generalized spectral localization by imaging (GSLIM) was applied to a model of unilateral stroke in gerbil brain. GSLIM lactate images at 4T clearly reveal elevated concentrations of lactate in the ischemic compared with the normal hemisphere 100-175 minutes after unilateral carotid ligation. These results indicate that the technique is capable of studies of brain infarcts, and that application to human ischemic pathology in brain and other tissues may be possible.

Animals↗

A fast spin echo technique with circular sampling.

This paper presents a fast spin echo (FSE) imaging method that employs circular sampling of k-space. The technique has been implemented on a 2 Tesla imaging system and validated on both phantoms and living animals. Experimental studies have shown that circular sampling can produce artifact-free FSE images without the need of phase correction. Although not fully explored, preliminary results also show that circular sampling may have advantages over the conventional rectilinear FSE in signal-to-noise ratio and imaging efficiency. A major disadvantage is the increased sensitivity to off-resonance effects. The authors expect that the FSE technique with circular sampling will find its applications in magnetic resonance microscopy, neuro-functional imaging, and real-time dynamic studies.

Animals↗

Biochemical heterogeneity in hysterectomized uterus measured by 31P NMR using SLIM localization.

Ultrasound and magnetic resonance imaging show contrast between the inner and outer myometrium, which is useful in the diagnosis of gynecological disorders. To determine whether the image contrast is associated with biochemical differences between these myometrial regions, phosphorus metabolite concentrations in the inner one third of the myometrium (the junctional zone; JZ) were compared with the outermost one third of the myometrium (OM) in hysterectomized uteri using 31P spectral localization by imaging (SLIM). The technique was validated by comparing the results of SLIM with the results of standard Fourier-encoded spectroscopic imaging (FSI) analysis using phantoms, and by nonlocalized spectroscopy on biopsies taken from the same hysterectomy specimens. As expected theoretically, SLIM yielded better localization than FSI, as judged by spectral intensity and leakage measurements on phantom compartments of known composition. SLIM localization revealed that the JZ has a higher intracellular phosphomonoester (PME) concentration than does the OM, which was confirmed by nonlocalized spectroscopy, and that there is very little NMR-visible phosphorus in the cervix.

Adult↗

Quantitative lactate-specific MR imaging and 1H spectroscopy of skeletal muscle at macroscopic and microscopic resolutions using a zero-quantum/double-quantum coherence filter and SLIM/GSLIM localization.

Quantitative lactate imaging and spectroscopy were performed on phantoms and on electrically stimulated, excised frog skeletal muscle at macroscopic and microscopic resolutions. Lactate selectivity was achieved by use of a zero-quantum/double-quantum coherence (ZQC/DQC) lactate filter, which suppressed all signals besides lactate, including water and lipid, to below noise level. Three-dimensional lactate data sets were acquired in 1-3 h; one of these spatial dimensions was frequency-encoded and the other two were phase-encoded. High-resolution images were reconstructed using the spectral localization by imaging (SLIM) and generalized SLIM (GSLIM) techniques. Lactate quantitation was achieved by employing an external lactate concentration standard and was verified by comparison to quantitative STEAM-localized and nonlocalized spectra that used total creatine as an internal concentration reference. Additionally, quantitatively accurate behavior of the SLIM and GSLIM techniques as applied to data sets of low signal-to-noise ratio and to macroscopically heterogeneous objects was verified using simulations and real muscle lactate data sets with known heterogeneity.

Animals↗

A comparison of RIGR and SVD dynamic imaging methods.

Several constrained imaging methods have recently been proposed for dynamic imaging applications. This paper compares two of these methods: the Reduced-encoding Imaging by Generalized-series Reconstruction (RIGR) and Singular Value Decomposition (SVD) methods. RIGR utilizes a priori data for optimal image reconstruction whereas the SVD method seeks to optimize data acquisition. However, this study shows that the existing SVD encoding method tends to bias the data acquisition scheme toward reproducing the known features in the reference image. This characteristic of the SVD encoding method reduces its capability to capture new image features and makes it less suitable than RIGR for dynamic imaging applications.

Image Processing, Computer-Assisted↗

A software system for interactive MR signal processing.

This paper describes a new software platform called "V" which is designed for interactive processing of magnetic resonance data. The package currently contains a variety of functions for image reconstruction and spectral data analysis. More importantly, it provides a framework to facilitate the exchange and application of processing algorithms among researchers in the field. We discuss the architecture of the package, give an example to demonstrate its operation and provide instructions for obtaining the software.

Algorithms↗

Fast dynamic imaging using two reference images.

This paper presents a fast dynamic imaging method which is characterized by the acquisition of two high-resolution reference images and a sequence of low-resolution dynamic data sets. Image reconstruction is accomplished using a generalized series based algorithm. Experimental results demonstrate that dynamic images with high temporal resolution can be obtained while maintaining excellent spatial resolution. This method will be useful for a variety of dynamic imaging applications including contrast-enhanced dynamic imaging and functional brain studies.

Algorithms↗

[Breeding grass carp against mosquitoes in rice field].

In this experimental study, grass carp were bred in rice field (1.9 fish/m2) to control mosquito larvae. 78 days after treatment, the larvae population of An. sinensis and Cu. tritaeniorhynchus dropped down by 87.4% and 80% respectively. Newly hatched 1-2 instar larvae accounted for 73.3% of the larvae remained in rice field after treatment. Eighty-nine samples of fish feces taken from rice field and 10 fishes were examined for breathing syphons of mosquito larvae. Breathing syphons were found in 22 fecal samples (24.7% positive) and 3 fishes (30% positive). The average number of mosquito larvae devoured by one fish was 861.5 in 24 hours in tap water and 661 in 24 hours in water containing grass and aquatic plants. The simulated field test showed that the average number of mosquito larvae devoured by fish was 362 larvae in 24 hours. The field trial indicated that the grass carp could not only cut down the mosquito larvae population but also benefit the peasants by increasing the production of both fish and rice.

Animals↗

Phase-constrained data extrapolation method for reduction of truncation artifacts.

The authors present an improvement to a sigma-filter extrapolation method for the reconstruction of magnetic resonance (MR) images from symmetric discrete Fourier data. By making use of the phase information in the image data, the proposed method can overcome the data inconsistency problem of the original method for handling MR image data with large phase variations, such as those obtained in gradient-echo pulse sequences. Reconstruction results show that its performance is comparable with that of the modified complex sigma-filter method proposed previously to handle the inconsistency problem. However, the new approach has the advantage of reducing computation time by a factor of two with use of a sigma filter applied to real instead of complex images. It is expected that this method will be more practical for use in clinical MR imaging systems.

Algorithms↗

Reduction of ringing and blurring artifacts in fast spin-echo imaging.

A simple method was devised to reduce ringing and blurring artifacts caused by discontinuous T2 weighting of k-space data in fast spin-echo magnetic resonance (MR) imaging. The method demodulates the weighting function along the phase-encoding direction by using multiple T2 values derived from a set of non-phase-encoded echoes obtained from an extra excitation. The performance of this method was evaluated by computer simulations and experiments, which confirmed its capability of effectively reducing or, in some cases, even completely removing the ringing and blurring artifacts. The results also show that the proposed method produces better results than other artifact reduction methods. The method is particularly useful at high magnetic field strengths (7.1-9.4 T) and with strong gradients (> 20 G/cm) used in MR microscopy, in which the apparent T2 values are short for most tissues. The authors expect that the proposed method will find useful applications in various fast spin-echo pulse sequences.

Artifacts↗

Applications of reduced-encoding MR imaging with generalized-series reconstruction (RIGR).

The RIGR (reduced-encoding imaging by generalized-series reconstruction) technique for magnetic resonance imaging uses a high-resolution reference image as the basis set for the reconstruction of subsequent images acquired with a reduced number of phase-encoding steps. The technique allows increased temporal resolution in applications requiring repeated acquisitions, such as the dynamic imaging of contrast agent biodistribution, and in intrinsically time-consuming protocols such as the acquisition of a series of T2-weighted images. Several examples are presented to demonstrate that a four- to eightfold improvement in spatial or temporal resolution can be achieved with this technique.

Animals↗

Application of reduced-encoding imaging with generalized-series reconstruction (RIGR) in dynamic MR imaging.

Dynamic MRI has proven to be an important tool in studies of transient physiologic changes in animals and humans. High sensitivity and temporal resolution in such measurements are critical for accurate estimation of dynamic information. Fast imaging, often involving expensive hardware, has evolved for use in such cases. We demonstrate herein the possibility of accelerated data acquisition schemes on conventional machines using standard pulse sequences for dynamic studies. This is achieved by combining reduced-encoded dynamic data (typically 30 to 40 phase encodings) with a priori high-resolution data via a novel constrained image reconstruction algorithm. Such an approach reduces image acquisition time significantly (by a factor of 3 to 4 in the examples described here) without loss in the accuracy of information.

Animals↗

A simulation study to assess SVD encoding for interventional MRI: effect of object rotation and needle insertion.

Singular value decomposition (SVD) encoding offers great promise to provide high spatial and temporal resolution required for interventional MRI (I-MRI) (1). This study investigates its efficacy when (a) objects are rotated and (b) a small device (ie, a needle) is moved within anatomic structures. It was found that SVD-encoded MRI is biased toward the reference from which encoding vectors are derived, thus providing a potential limitation under conditions in which the object has undergone significant global change. Reference images with partial device insertion may be needed to accurately resolve the device or track the object motion. Theoretically, the differences between the reference and the object being imaged suggest that SVD encoding is suboptimal (in a minimum mean squared error sense). Other encoding/reconstruction algorithms may come closer to achieving the desired advantages in spatial and temporal fidelity.

Biopsy, Needle↗

Constrained reconstruction: a superresolution, optimal signal-to-noise alternative to the Fourier transform in magnetic resonance imaging.

Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference phenomena in optics and is known as the Gibbs phenomenon in engineering. Present techniques to cope with this problem include filtering and regularization schemes based on minimum norm or maximum entropy constraints. In this paper, a new technique based on object modeling and estimation is developed to achieve superresolution reconstruction from partial Fourier transform data. The nonlinear parameters of the object model are obtained using the singular value decomposition (SVD)-based all-pole model framework, and the linear parameters are determined using a standard least squares estimation method. This technique is capable, in principle, of unlimited resolution and is robust with respect to Gaussian white noise perturbation to the measured data and with respect to systematic modeling errors. Reconstruction results from simulated data and real magnetic resonance data are presented to illustrate the performance of the proposed method.

Fourier Analysis↗