Wedge-shaped BGO scintillation crystal for positron emission tomography: concise communication.

In order to increase the detection efficiency and also reduce the interdetector spillage, a new wedge-shaped BGO scintillation detector array is proposed. By shaping the front part of a detector as a wedge, the absorption path becomes longer, particularly for obliquely incident photons, thereby improving the uniformity in the sensitivity for the incident photons of different angles. To demonstrate the effectiveness of the proposed detector shape, a Monte Carlo simulation was performed and the results are presented.

Bismuth↗

High-resolution circular ring positron tomograph with dichotomic sampling: Dichotom-I.

The circular ring transaxial positron camera developed earlier was refitted with a new dichotomic sampling scheme and aperture collimators on the detector array to improve the sampling and the overall system resolution. The z-axis slice thickness collimators were also limited to 1 cm, which corresponds to a slice thickness of 0.5 cm FWHM. Two different types of aperture collimators were adopted for high resolution (HR) and very high resolution (VHR) imaging, respectively. In HR mode a resolution of 6.5 mm FWHM was obtained without appreciable degradation of overall sensitivity, which represents a threefold improvement in resolution over the original system. In phantom studies with HR mode a sensitivity of 4500 counts s-1 muCi-1 cm-3 was obtained for a 20 cm diameter uniform phantom filled with water. A VHR mode experiment was also conducted to observe the ultimate resolution capability of the Dichotom-I system, and a resolution of 4.2 mm FWHM was obtained at the expense of sensitivity which was reduced by a factor of four from the HR mode experiment. The experience gained with Dichotom-I suggests a relatively simple and inexpensive modification of the existing NaI(T1) ring positron cameras, most of which suffer from low resolution due to poor sampling and poor intrinsic detector resolution.

Animals↗

Bismuth germanate as a potential scintillation detector in positron cameras.

Timing and energy resolutions of the bismuth germanate (Bi4Ge3O12) scintillation crystals were studied, with particular respect to a positron-camera application. In comparison with the NaI(Tl) system, the detection efficiency for annihilation radiation is more than triple, and coincidence detection efficiency is more than ten times as good. This paper explores the properties of the new scintillator material and their bearing on the spatial resolution and the efficiency of coincidence detection in positron cameras with stationary ring detectors.

Bismuth↗

Physics of contrast mechanism and averaging effect of linear attenuation coefficients in a computerized transverse axial tomography CTAT) transmission scanner.

Detailed studies of the basic contrast mechanisms in computerized transverse axial tomography scanners have been carried out. Contrast is related to the effective atomic numbers and electron densities of materials and the resultant linear attenuation coefficients. We have therefore quantitatively evaluated various samples defined by these parameters. A multienergetic X-ray source causes resolution degrading problems arising from the averaging effect of the linear attenuation coefficients. The controversy regarding the use of fixed length water bath as a reference to compensate the spectral shift (hardening) effect of the multienergetic X-ray source is also analysed and reported. Computer simulations demonstrating the sensitivities of the linear attenuation coefficient measurements and errors, as functions of the energy spectrum, were made for representative cases. Simulation results indicate that by using a full water bath, artifacts stemming from the multienergetic X-ray souce can be significantly reduced. An alternative approach using a count rate equalizer, considered to be another way of reducing the wide dynamic range in count rate when a water bath is not used, is also studied and the results reported.

Biophysical Phenomena↗

Study of contrast and modulation mechanisms in X-ray/photon transverse axial transmission tomography.

The ultimate capabibity and a detailed study of contrast and modulation in the context of photon transmission tomography (or computerized transverse axial tomography (CTAT)) is presented. Quantitative evaluation of atomic number, density and electron density of compound materials were made by X-ray fluorescence and combustion analysis, and the attenuation coefficients of photoelectric and Compton effect were measured with high resolution Ge(Li) and Si(Li) detectors. This study provides a guide to an understanding of the high resolution of the currently existing X-ray transmission CTAT scanner (EMI scanner) and to the future development of high resolution scanners.

Brain↗

Semiconductor camera for detection of small tumors.

Early detection of small tumors (approximately 3 mm) with only a moderate uptake ratio is often difficult because of poor statistics and a small signal-to-background ratio. The detection capability of a germanium semiconductor camera is analyzed to show that a very large number of counts is required even when the spatial resolution is matched to the size of the tumor. A potential enhancement of statistics using the tissue-scattered gamma rays is discussed based on the superior energy resolution of the semiconductor.

Gamma Rays↗

In vivo NMR imaging of sodium-23 in the human head.

We report the first clinical nuclear magnetic resonance (NMR) images of cerebral sodium distribution in normal volunteers and in patients with a variety of pathological lesions. We have used a 1.5 T NMR magnet system. When compared with proton distribution, sodium shows a greater variation in its concentration from tissue to tissue and from normal to pathological conditions. Image contrast calculated on the basis of sodium concentration is 7 to 18 times greater than that of proton spin density. Normal images emphasize the extracellular compartments. In the clinical studies, areas of recent or old cerebral infarction and tumors show a pronounced increase of sodium content (300-400%). Actual measurements of image density values indicate that there is probably a further accentuation of the contrast by the increased "NMR visibility" of sodium in infarcted tissue. Sodium imaging may prove to be a more sensitive means for early detection of some brain disorders than other imaging methods.

Brain Neoplasms↗

An improved nuclear magnetic resonance diffusion coefficient imaging method using an optimized pulse sequence.

Two-dimensional diffusion coefficient maps (images) of a carefully controlled diffusion phantom have been measured by a new diffusion imaging sequence using a 0.6-T whole-body nuclear magnetic resonance (NMR) scanner having a gradient field strength of 2.5 mT/m. The free induction decay (FID) data for the diffusion coefficient images were collected by varying the duration of the readout gradient in the conventional two-dimensional Fourier imaging sequence. The experimental results obtained by the proposed NMR diffusion measurement technique indicate a close agreement with other previous measurements. The selection of optimum spin-echo time for maximum signal-to-noise ratio (SNR) in diffusion imaging is studied and also experimentally confirmed. Finally, a preclinical study with human volunteers has been performed and results are presented.

Humans↗

The effects of random directional distributed flow in nuclear magnetic resonance imaging.

Capillary flow or microscopic random directional coherent flow as a model of perfusion is investigated both theoretically and experimentally. In the model, we assumed that molecular motion within a finite resolvable volume element (voxel) is a superposition of flow of randomly oriented small capillaries. In such a case, the observed signal from the capillary flow within a voxel will be attenuated in signal amplitude without any change in phase. Although this attenuation effect is similar to the diffusion phenomenon, it differs basically in the following aspects: since the motion in each capillary segment is coherent, phase cancellation occurs at even echoes due to spin rephasing, while the diffusion phenomenon is a purely random Brownian motion of the thermally agitated molecules, changing both in direction and speed during the measurement period. Because of the random character of diffusion, even-echo rephasing cannot be observed. Thus capillary flow or perfusionlike microscopic flow can be measured based on the above distinct flow characteristics, i.e., signal restoration at even echoes versus signal amplitude attenuation at odd echoes. By applying a suitable mathematical algorithm, information on the capillary flow alone can be extracted from the two separate distinct measurements, i.e., one with a single echo and the other with a double echo. Both a theoretical calculation of the capillary flow, as well as the experimental results with a human volunteer by a 0.6-T nuclear magnetic resonance imager, are presented.

Algorithms↗

Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting.

A correction technique of the total magnetic field inhomogeneity effects including the localized object induced inhomogeneities such as chemical shift and susceptibility is developed and its usefulness is experimentally demonstrated. With this new and simple technique all the inhomogeneity induced artifacts can be corrected simultaneously. The basic idea of this method is to add a compensation gradient of the same amplitude as the selection gradient in simultaneity with the reading gradient in such a way that the view angle is tilted. Thereby all the inhomogeneity induced geometrical shifts and hence the intensity changes are corrected, since the addition of the compensation which is independent from the field inhomogeneities including both chemical shifts and susceptibility. This technique has been theoretically examined and its usefulness is demonstrated by experiments.

Humans↗

Nuclear magnetic resonance microscopy with 4-microns resolution: theoretical study and experimental results.

Nuclear magnetic resonance (NMR) microscopy with 4-microns resolution, a step closer to the 1-micron resolution with which in vivo cellular imaging would be possible is described. An analysis of the ultimate resolution and voxel size dependent signal-to-noise ratio (SNR) in NMR microscopy is presented and experimentally verified. For microscopic scale objects (less than 1-mm diameter), the SNR based on the geometrical scale factor(s) is found to be proportional to sn where n less than 2, rather than n = 3 as previously supposed. This comes about because of a drastic reduction in sample noise coupled with a significant sensitivity gain realized in small diameter radiofrequency coils. A new pulse sequence which reduces both diffusion dependent resolution degradation and signal attenuation is presented. The selection of optimal bandwidth and acquisition time for maximal SNR is discussed. Experimental results obtained on both a 2.0-T whole-body system and a 7.0-T small bore system adapted for microscopy indicate the potentials of 4-microns resolution microscopy with the existing magnets.

Animals↗

A generalized formulation of diffusion effects in micron resolution nuclear magnetic resonance imaging.

A generalized formulation of the diffusion related nuclear magnetic resonance (NMR) signal is derived from a random walk model. Previous analyses performed in the NMR spectroscopy were the formulations of the diffusion related signal amplitude at a specific time, such as the spin echo formation time. They are, in general, not applicable to continuous time domain analyses. In this paper, we have extended the theory to the two-dimensional imaging case and derived an analytical formula useful for the computation of the diffusion affected signal as a function of continuous time for a time variant gradient. This formulation will be useful in NMR imaging, especially in NMR microscopy where the diffusion associated signal attenuation is serious due to the strong gradient fields (100-1000 G/cm), and at the same time data are acquired continuously for the acquisition period. In addition to the loss of the resolution and signal-to-noise ratio due to the random phase fluctuation by diffusion, the variation of the intensity during the data acquisition period introduces a line broadening whose full width at half-maximum is found to be much larger than the bandwidth-limited resolution or diffusion related intrinsic resolution. This line spreading effect is integrated in a computer simulation and is evaluated as an integral part of the overall diffusion effects in micron resolution NMR imaging or NMR microscopy.

Computer Simulation↗

Localized in vivo high-resolution NMR imaging using gradient subencoding technique.

A new spatial localization technique for in vivo high-resolution imaging is presented here. In contrast to other localization techniques that use a series of rf pulses to define a volume of interest, only one rf pulse is utilized in the proposed method for selection of a region to be imaged. Instead of rf pulses for region selection, subencoding gradient pulses are used for the localization together with a convolution process on each phase-encoding gradient by a set of additional gradients (e.g., y direction). Then the 2-D localization is completed by restricting the bandwidth in the readout direction (e.g., x direction). The latter is simply achieved by using a low-pass filter in the receiver system. By applying this technique on a human body, localized in vivo high-resolution images are obtained for the knee with much improved resolution. 100 x 100 microns in-plane (x,y plane) resolution images obtained from the human knee demonstrate that localized in vivo high-resolution imaging for both human and animals is possible with an in-plane resolution of below 100 microns.