Search PubMed⌕ Search

Biomedical subjects

Yves Lachkar

Publications and source records attributed to Yves Lachkar.

4 recordsLinked to original sources

Asymmetric pigmentary glaucoma in a patient with Marfan's syndrome.

BACKGROUND: No relationship between Marfan's syndrome and pigmentary glaucoma has previously been described in the ophthalmic literature. We describe the case of a patient with Marfan's syndrome who had bilateral pigment dispersion syndrome and asymmetrical glaucoma. METHODS: A 34-year-old man with Marfan's syndrome developed pigment dispersion bilaterally. In the right eye, elevated intra-ocular pressure was associated with marked glaucomatous excavation of the right disc and corresponding visual field loss. A localised zonular dehiscence was present at the 6 o'clock position in the right eye. RESULTS: Ultrasound biomicroscopy showed marked iris concavity in the right eye, increased iridolenticular contact and superior subluxation of the right lens, resulting in increased dispersion of pigment unilaterally. This explains the asymmetric pattern of the glaucomatous damage. CONCLUSIONS: Asymmetrical progression of pigmentary glaucoma is uncommon and should prompt a search for some other mechanical factor, which might increase the iridozonular contact on one side or reduce it on the other. The association between the two syndromes in this patient was most likely mechanical due to reduced fibrillin expression throughout the eye and particularly in the iris and the lens zonules, resulting in loss of iris tensile strength and marked iris concavity as well as zonular weakness and partial lens subluxation.

Adult↗

Comparison of dynamic contour tonometry with goldman applanation tonometry over a wide range of central corneal thickness.

PURPOSE: To compare dynamic contour tonometry with Goldmann applanation tonometry in structurally normal corneas over a wide range of central corneal thickness (CCT). PATIENTS AND METHODS: Twenty-five patients each with normal CCT (group A), thin corneas (group B), and thick corneas (group C) had IOP measured with the Goldmann (GAT) and dynamic contour tonometer (DCT). RESULTS: In group A (mean CCT = 552 +/- 16 microm) the mean GAT was 15.9 +/- 3.1 mm Hg and mean DCT was 16 +/- 3.3 mm Hg (P = 0.91). In group B (mean CCT = 491 +/- 19 microm) the mean GAT was 13.2 +/- 3.5 mm Hg and the mean DCT was 15.9 +/- 3.5 mm Hg (P = 0.009). For group C (mean CCT = 615 +/- 22 microm), the mean GAT was 17.4 +/- 3.8 mm Hg and the mean DCT was 17.4 +/- 3.5 mm Hg (P = 0.95). The 95% agreement limits for DCT were -3.1 mm Hg to 2.9 mm Hg. The mean GAT-DCT difference was -2.6 mm Hg in thin corneas and -0.06 mm Hg in thick corneas. Below 520 microm reduction of 10 microm in CCT appears to result in a significant underestimation of the GAT IOP by 0.7 mm Hg (P < .001) and above 580 microm a non-significant overestimation of 0.2 mm Hg per 10 microm increase in CCT (P = 0.27). CONCLUSION: Dynamic contour tonometer agrees well on average with GAT but the agreement limits are wide. In structurally normal thin corneas DCT may give a more accurate assessment of the true IOP but it does not appear to have any benefit over GAT in thick corneas.

Adult↗

Central corneal thickness and vascular risk factors in normal tension glaucoma.

BACKGROUND: Normal tension glaucoma (NTG) has been shown to be associated with reduced central corneal thickness (CCT). The association of NTG with vascular risk factors is well documented. It has been postulated that a subset of NTG patients are misclassified due to incorrect intraocular pressure measurements on thin corneas. The aim of this study was to establish whether corneal thickness in NTG differs between patients with vascular risk factors specific to NTG and those without. METHODS: The study comprised a retrospective analysis of 108 eyes of 54 patients with NTG and 54 patients with primary open-angle glaucoma (POAG). Corneal thickness was measured in all patients. Vascular risk factors were recorded. Patients with NTG were divided into two groups depending on the presence (group A) or absence (group B) of vascular risk factors. RESULTS: The mean CCT was 549 +/- 34 microm in patients with POAG and 528 +/- 31 microm in patients with NTG (p = 0.001). Mean CCT was 512 +/- 31 microm in group A (n = 13) and 533 +/- 31 microm in group B (n = 41) (p = 0.034). A total of 40.9% of those with thin corneas (n = 22) had vascular risk factors versus only 12.5% of those with CCT within the normal range (n = 32) (p < 0.05). CONCLUSION: Central corneal thickness in NTG was significantly lower than in POAG and corneas were thinner in NTG patients with vascular risk factors than in those without. Vascular risk factors were significantly more common in patients with thin corneas. The finding of reduced corneal thickness in NTG does not obviate the need to consider vascular risk factors in the pathophysiology of the disease.

Adult↗

Nonpenetrating filtering surgery.

Trabeculectomy is currently the standard filtration procedure for surgical treatment of glaucoma. This technique has advantages over full thickness procedures but can cause early postoperative complications such as hyphema, shallow or flat anterior chamber, hypotony with the risk of choroidal detachment, and maculopathy. Nonpenetrating procedures are alternatives to trabeculectomy with the advantage of minimizing the risk of postoperative complications related to hypotony. The two major variations of nonpenetrating glaucoma surgery are nonpenetrating deep sclerectomy and viscocanalostomy. Techniques and results are discussed in this paper.

Filtering Surgery↗