Search PubMed⌕ Search

Biomedical subjects

Yunsheng Hsieh

Publications and source records attributed to Yunsheng Hsieh.

27 records · Page 2Linked to original sources

Direct plasma analysis of drug compounds using monolithic column liquid chromatography and tandem mass spectrometry.

A monolithic silica column high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed for the high-speed direct simultaneous determination of a drug discovery compound and its major circulating metabolite (M-72) in rat plasma. This methodology makes use of flow programming and an alkyl-bonded silica rod column for fast macromolecule removal and chromatographic separation without the need for significant sample preparation. The matrix ionization suppression effect on the monolithic column HPLC-MS/MS system was investigated using the postcolumn infusion technique. After 200 plasma injections on a 50 x 4.6 mm monolithic silica column, consistent column efficiency of close to 39,000 theoretical plates/m and reproducible retention times for the analytes were observed. The apparent on-column recoveries of 12 test compounds in rat plasma samples were greater than 90%. The proposed fast direct plasma injection method was tested over a 3-day period with the interday coefficient of variation less than 15% for both analytes.

Calibration↗

Pharmacological characterization of the novel histamine H3-receptor antagonist N-(3,5-dichlorophenyl)-N'-[[4-(1H-imidazol-4-ylmethyl)phenyl]-methyl]-urea (SCH 79687).

We present the pharmacological and pharmacokinetic profiles of a novel histamine H3 receptor antagonist, N-(3,5-dichlorophenyl)-N'-[[4-(1H-imidazol-4-ylmethyl)phenyl]-methyl]-urea (SCH 79687). The H3-receptor binding Ki values for SCH 79687 were 1.9 and 13 nM in the rat and guinea pig (GP), respectively. The Ki values for SCH 79687 at histamine H1 and H2 receptors were greater than 1 microM. SCH 79687 showed a 41- and 82-fold binding selectivity for the H3 receptor over alpha 2A-adrenoceptors and imidazoline I2, and >500-fold H3 selectivity compared with over 60 additional receptors. The pA2 value for SCH 79687 in the GP ileum electrical field-stimulated (EFS) contraction was 9.6 +/- 0.3. Similar H3 antagonist activity was observed in the EFS cryopreserved and fresh tissue isolated human saphenous vein (HSV) assays (pKb = 9.4 +/- 0.3 and 10.1 +/- 0.4). SCH 79687 (30 nM) did not block clonidine-induced inhibition of EFS-induced contractions in HSV. SCH 79687 (ED50 = 0.3 mg/kg i.v.) attenuated (R)-alpha-methylhistamine inhibition of sympathetic hypertensive responses in the GP. At the time of activity evaluation, the GP plasma SCH 79687 concentration was 25 ng/ml at the dose of 0.3 mg/kg i.v. In feline nasal studies, combined administration of SCH 79687 (3 mg/kg i.v.) and the H1-antagonist loratadine (3 mg/kg i.v.), at individual doses that do not produce decongestion, inhibited the compound 48/80-induced congestion by 47%. The alpha-adrenergic agonist phenylpropanolamine (PPA; 1 mg/kg i.v.) also attenuated compound 48/80 nasal responses by 42%. Unlike the H3/H1 combination that did not affect blood pressure (BP), PPA (1 mg/kg i.v.) significantly increased BP compared with control animals by a maximum of 31 mm Hg. Orally, SCH 79687 (10 mg/kg) plus loratadine (10 mg/kg) also produced decongestion without effects on BP. In pharmacokinetic studies, oral dosing with SCH 79687 in the rat (10 mg/kg) and monkey (3 mg/kg) achieved plasma Cmax and area under the curve values greater than 1.5 and 12.1 microg. h/ml, respectively. SCH 79687 is an orally active H3 antagonist with a good pharmacokinetic profile that, in combination with an H1 antagonist, demonstrates decongestant efficacy comparable with oral sympathomimetic decongestants but without hypertensive liabilities.

Animals↗

Direct analysis of drug candidates in tissue by matrix-assisted laser desorption/ionization mass spectrometry.

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been used to directly analyze and image pharmaceutical compounds in intact tissue. The anti-tumor drug SCH 226374 was unambiguously determined in mouse tumor tissue using MALDI-QqTOFMS (QSTAR) by monitoring the dissociation of the protonated drug at m/z 695.4 to its predominant fragment at m/z 228.1. A second drug, compound A, was detected in slices of rat brain tissue following oral administration with doses ranging from 1-25 mg/kg. Quantitation of compound A from whole brain homogenates using routine high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) procedures revealed that concentrations of the drug in whole brain varied from a low of 24 ng/g to a high of 1790 ng/g. The drug candidate was successfully detected by MALDI-QqTOF in samples from each dose, covering a range of approximately two orders of magnitude. In addition, good correlation was observed between the MALDI-QqTOFMS intensities at each dose with the HPLC/MS/MS results. Thus the MALDI-MS response is proportional to the amount of drug in tissue. Custom software was developed to facilitate the imaging of small molecules in tissue using the MALDI-QqTOF mass spectrometer. Images revealing the spatial localization of SCH 226374 in tumor tissue and compound A in brain tissue were acquired.

Animals↗

Zirconia-based column high-performance liquid chromatography/atmospheric pressure photoionization tandem mass spectrometric analyses of drug molecules in rat plasma.

A method using zirconia-based column high-performance liquid chromatography (HPLC) interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer (MS/MS) was developed for the quantitative determination of new chemical entities in rat plasma in support of pharmacokinetics studies. The ionization suppression resulting from endogenous components of the biological matrices on the quantitative zirconia-based column HPLC/APPI-MS/MS method was investigated using the post-column infusion technique. The analytical results for 'rapid rat pharmacokinetics' for 12 drug discovery compounds, obtained by both silica-based phase (S-phase) and zirconia-based phase (Z-phase) chromatographic separation, are in good agreement in terms of accuracy. The application of a Z-phase column for high-temperature fast HPLC/MS/MS methods was explored to reduce the analysis time from 3 min to 30 s for column temperatures of 25-110 degrees C, respectively. The chromatographic retention times and peak responses of all analytes were found to be reproducible under high-temperature conditions following 100 continuous injections, with %CV less than 0.4 and 5, respectively.

Animals↗

Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays: application to drug discovery.

A series of studies was performed to investigate some of the causes for matrix effects ('ion suppression' or 'ion enhancement') in bioanalytical high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assays. Previous studies have reported that matrix effects are mainly due to endogenous components in biological fluids and are a greater concern for electrospray ionization (ESI) than for atmospheric pressure chemical ionization (APCI). In this report we demonstrate that: (1) matrix effects can also be caused by exogenous materials, such as polymers contained in different brands of plastic tubes, or Li-heparin, a commonly used anticoagulant; (2) matrix effects are not only ionization mode (APCI or ESI) dependent, but also source design (Sciex, Finnigan, Micromass) dependent; and (3) for at least one vendor's design, we found the APCI mode to be more sensitive to matrix effects than the ESI mode. Based on these findings, we have proposed the following simple strategies to avoid matrix effects: (1) select the same brand of plastic tubes for processing and storing plasma samples and spiked plasma standards; (2) avoid using Li-heparin as the anticoagulant; and (3) try switching the ionization mode or switching to different mass spectrometers when matrix effects are encountered. These three strategies have allowed us to use protein precipitation and generic fast LC techniques to generate reliable LC/MS/MS data for the support of pharmacokinetic studies at the early drug discovery stage.

Animals↗

Semi-automated determination of plasma stability of drug discovery compounds using liquid chromatography-tandem mass spectrometry.

A simple procedure for the measurement of stability of drug candidates in plasma was developed to eliminate the traditional labor-intensive and time-consuming sample preparation procedures that are typically used for these studies. The procedure makes use of a thermostatic autosampler as an incubator combined with the direct plasma injection method based on high-performance liquid chromatography (HPLC) coupled to tandem mass spectrometry (MS-MS). Untreated human, monkey, mouse and rat plasma containing the test compound was directly injected into a mixed-function column for on-line protein removal and chromatography. The test compound and its biotransformation product were separated via HPLC and monitored using the tandem mass spectrometer. The need for adequate chromatographic separation of the test compound (M) from its carboxylic acid metabolite (M+1) is demonstrated. Plasma samples from four different species at specified incubation temperatures were sequentially assayed in one analytical procedure. The injection-to-injection time was about 6 min. The peak responses of the test compound in individual plasma samples were repeatedly determined every 24 min. The retention times and peak shape of all analytes were found to be consistent throughout the experiments. The stability of the test compound in plasma was found to be a function of animal species, incubation time and temperature. The test compound was rapidly degraded in rat plasma at 37 degrees C, but it could be stabilized by adding sodium thiosulfate.

Automation↗

Direct cocktail analysis of drug discovery compounds in pooled plasma samples using liquid chromatography-tandem mass spectrometry.

Direct plasma injection technology coupled with a LC-MS/MS assay provides fast and straightforward method development and greatly reduces the time for the tedious sample preparation procedures. In this work, a simple and sensitive bioanalytical method based on direct plasma injection using a single column high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) was developed for direct cocktail analysis of double-pooled mouse plasma samples for the quantitative determination of small molecules. The overall goal was to improve the throughput of the rapid pharmacokinetic (PK) screening process for early drug discovery candidates. Each pooled plasma sample was diluted with working solution containing internal standard and then directly injected into a polymer-coated mixed-function column for sample clean-up, enrichment and chromatographic separation. The apparent on-column recovery of six drug candidates in mouse plasma samples was greater than 90%. The single HPLC column was linked to either an atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI) source as a part of MS/MS system. The total run cycle time using single column direct injection methods can be achieved within 4 min per sample. The analytical results obtained by the described direct injection methods were comparable with those obtained by semi-automated protein precipitation methods within +/- 15%. The advantages and challenges of using direct single column LC-MS/MS methods with two ionization sources in combination of sample pooling technique are discussed.

Chromatography, High Pressure Liquid↗

Direct simultaneous determination of drug discovery compounds in monkey plasma using mixed-function column liquid chromatography/tandem mass spectrometry.

A direct injection method based on a single column and high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS) was developed for the simultaneous determination of two drug candidates in monkey plasma samples in support of pharmacodynamic studies. Each diluted monkey plasma sample containing internal standard was directly injected into a mixed-function column for sample cleanup, enrichment and chromatographic separation. The proteins and macromolecules first passed through the column while the drug molecules were retained on the bonded hydrophobic phase. The analytes retained on the column with an aqueous liquid mobile phase were then chemically eluted by switching to a strong organic mobile phase at a constant flow rate of 1.0 ml/min. The column effluent was also diverted from waste to mass spectrometer for analyte detection. Samples from two different analyte studies were assayed in one analytical procedure and the calibration curves were prepared using both analytes. The calibration curves were linear over the range of 5-2500 ng/ml for both analytes. The retention times for analytes and the internal standard were found to be consistent and no column deterioration was observed after 200 injections. The apparent on-column recoveries for the test compounds in monkey plasma samples were greater than 90% with 6% CV (N=5). The total analysis time was less than 5 min per sample.

Animals↗

Simultaneous determination of a drug candidate and its metabolite in rat plasma samples using ultrafast monolithic column high-performance liquid chromatography/tandem mass spectrometry.

An ultrafast bioanalytical method using monolithic column high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) was evaluated for the simultaneous determination of a drug discovery compound and its metabolite in plasma. Baseline separation of the two compounds was achieved with run times of 24 or 30 s under isocratic or gradient conditions, respectively. The monolithic column HPLC/MS/MS system offers shorter chromatographic run times by increasing flow rate without sacrificing separation power for the drug candidate and its biotransformation product (metabolite). In this work, the necessity for adequate chromatographic resolution was demonstrated because the quantitative determination of the drug-related metabolism product was otherwise hampered by interference from the dosed drug compound. The chromatographic performance of a monolithic silica rod column as a function of HPLC flow rates was investigated with a mixture of the drug component and its synthetic metabolite. The assay reliability of the monolithic column HPLC/MS/MS system was checked for matrix ionization suppression using the post-column infusion technique. The proposed methods were successfully applied to the analysis of study rat plasma samples for the simultaneous quantitation of both the dosed drug and its metabolite. The analytical results obtained by the proposed monolithic column methods and the 'standard' silica particle-packed HPLC column method were in good agreement, within 10% error.

Animals↗