New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring.

This paper reports new methodology to obtain a calibration model for noninvasive blood glucose monitoring using diffuse reflectance near-infrared (NIR) spectroscopy. Conventional studies of noninvasive blood glucose monitoring with NIR spectroscopy use a calibration model developed by in vivo experimental data sets. In order to create a calibration model, we have used a numerical simulation of light propagation in skin tissue to obtain simulated NIR diffuse reflectance spectra. The numerical simulation method enables us to design parameters affecting the prediction of blood glucose levels and their variation ranges for a data set to create a calibration model using multivariate analysis without any in vivo experiments in advance. By designing the parameters and their variation ranges appropriately, we can prevent a calibration model from chance temporal correlations that are often observed in conventional studies using NIR spectroscopy. The calibration model (regression coefficient vector) obtained by the numerical simulation has a characteristic positive peak at the wavelength around 1600 nm. This characteristic feature of the regression coefficient vector is very similar to those obtained by our previous in vitro and in vivo experimental studies. This positive peak at around 1600 nm also corresponds to the characteristic absorption band of glucose. The present study has reinforced that the characteristic absorbance of glucose at around 1600 nm is useful to predict the blood glucose level by diffuse reflectance NIR spectroscopy. We have validated this new calibration methodology using in vivo experiments. As a result, we obtained a coefficient of determination, r2, of 0.87 and a standard error of prediction (SEP) of 12.3 mg/dL between the predicted blood glucose levels and the reference blood glucose levels for all the experiments we have conducted. These results of in vivo experiments indicate that if the parameters and their vibration ranges are appropriately taken into account in a numerical simulation, the new calibration methodology provides us with a very good calibration model that can predict blood glucose levels with small errors without conducting any experiments in advance to create a calibration model for each individual patient. This new calibration methodology using numerical simulation has promising potential for NIR spectroscopy, especially for noninvasive blood glucose monitoring.

Algorithms↗

Noninvasive near-infrared blood glucose monitoring using a calibration model built by a numerical simulation method: Trial application to patients in an intensive care unit.

We have applied a new methodology for noninvasive continuous blood glucose monitoring, proposed in our previous paper, to patients in ICU (intensive care unit), where strict controls of blood glucose levels are required. The new methodology can build calibration models essentially from numerical simulation, while the conventional methodology requires pre-experiments such as sugar tolerance tests, which are impossible to perform on ICU patients in most cases. The in vivo experiments in this study consisted of two stages, the first stage conducted on healthy subjects as preliminary experiments, and the second stage on ICU patients. The prediction performance of the first stage was obtained as a correlation coefficient (r) of 0.71 and standard error of prediction (SEP) of 28.7 mg/dL. Of the 323 total data, 71.5% were in the A zone, 28.5% were in the B zone, and none were in the C, D, and E zones for the Clarke error-grid analysis. The prediction performance of the second stage was obtained as an r of 0.97 and SEP of 27.2 mg/dL. Of the 304 total data, 80.3% were in the A zone, 19.7% were in the B zone, and none were in the C, D, and E zones. These prediction results suggest that the new methodology has the potential to realize a noninvasive blood glucose monitoring system using near-infrared spectroscopy (NIRS) in ICUs. Although the total performance of the present monitoring system has not yet reached a satisfactory level as a stand-alone system, it can be developed as a complementary system to the conventional one used in ICUs for routine blood glucose management, which checks the blood glucose levels of patients every few hours.

Blood Glucose↗

Simple algorithm for the measurement of absorption coefficients of a two-layered medium by spatially resolved and time-resolved reflectance.

An inversion procedure for the recovery of absorption coefficients of a two-layered semi-infinite diffusive medium by use of time-resolved reflectance measured at two different source-detector distances is proposed. The inversion procedure is based on the property of the photon diffusion equation; i.e., the solution of the diffusion equation for the time-resolved reflectance measured at a longer source--detector distance coincides with that measured at a shorter one by a proper temporal, spatial, and intensity transformation. This inversion procedure, used together with the results of one set of Monte Carlo simulations, is validated as working well when the values of the scattering coefficients of the two layers and the thickness of the first layer are within a range of interest in tissue optics.

Absorption↗

Time-resolved diffuse optical tomographic imaging for the provision of both anatomical and functional information about biological tissue.

We present in vivo images of near-infrared (NIR) diffuse optical tomography (DOT) of human lower legs and forearm to validate the dual functions of a time-resolved (TR) NIR DOT in clinical diagnosis, i.e., to provide anatomical and functional information simultaneously. The NIR DOT system is composed of time-correlated single-photon-counting channels, and the image reconstruction algorithm is based on the modified generalized pulsed spectral technique, which effectively incorporates the TR data with reasonable computation time. The reconstructed scattering images of both the lower legs and the forearm revealed their anatomies, in which the bones were clearly distinguished from the muscles. In the absorption images, some of the blood vessels were observable. In the functional imaging, a subject was requested to do handgripping exercise to stimulate physiological changes in the forearm tissue. The images of oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentration changes in the forearm were obtained from the differential images of the absorption at three wavelengths between the exercise and the rest states, which were reconstructed with a differential imaging scheme. These images showed increases in both blood volume and oxyhemoglobin concentration in the arteries and simultaneously showed hypoxia in the corresponding muscles. All the results have demonstrated the capability of TR NIR DOT by reconstruction of the absolute images of the scattering and the absorption with a high spatial resolution that finally provided both the anatomical and functional information inside bulky biological tissues.

Algorithms↗

Depth profile of diffuse reflectance near-infrared spectroscopy for measurement of water content in skin.

BACKGROUND/PURPOSE: The penetration depth of light in diffuse reflectance near-infrared spectroscopy for measuring water content in skin is assessed both from theoretical and experimental points of view. METHODS: The Monte Carlo simulation was implemented to investigate the dependencies of the light penetration depth on a source-detector distance. To compare with the simulation results, an in vivo experiment for water contents of skin was performed introducing two different optical fiber probes. RESULTS: It is found that the minimum separation between a source and detector fibers influences largely the measurement depth. The larger separation leads to a deeper measurement depth at a particular wavelength. The measurement depth is also influenced fairly by the absorption coefficient of the tissue. The larger absorption coefficient results in a shallower measurement depth. CONCLUSION: The correlations between the water contents measured by the optical and capacitance techniques were discussed. The dependencies of the light penetration depth on the source-detector geometry and wavelength are presented.

Absorption↗

A primary aorto-duodenal fistula associated with an inflammatory abdominal aortic aneurysm: a case report.

Primary aorto-enteric fistula (PAEF)is a serious complication of abdominal aortic aneurysm(AAA). We report a patient with PAEF associated with inflammatory AAA who underwent emergent surgery. A 52-year-old male presented with recurrent hematemesis. A computer tomography scan showed a sealed rupture of the AAA adjacent to the duodenum. At surgery, a coin-sized PAEF was noted. The aorta was replaced with a Dacron graft in situ . Histological examination revealed the characteristics of an inflammatory AAA. The postoperative course was uneventful, and there has been no evidence of infection during a follow-up period of 3 years. We discuss the etiologic and surgical considerations regarding this unusual entity.

Aortic Aneurysm, Abdominal↗

Musclin, a novel skeletal muscle-derived secretory factor.

Skeletal muscle is involved in the homeostasis of glucose and lipid metabolism. We hypothesized that the skeletal muscle produces and secretes bioactive factor(s), similar to adipocytokines secreted by fat tissue. Here, we report the identification of a novel secretory factor, musclin, by signal sequence trap of mouse skeletal muscle cDNAs. Musclin cDNA encoded 130 amino acids, including NH(2)-terminal 30-amino acid signal sequence. Musclin protein contained a region homologous to natriuretic peptide family, and KKKR, a putative serine protease cleavage site, similar to the natriuretic peptide family. Full-length musclin protein and KKKR-dependent cleaved form were secreted in media of musclin cDNA-transfected mammalian cell cultures. Musclin mRNA was expressed almost exclusively in the skeletal muscle of mice. Musclin mRNA levels in skeletal muscle were markedly low in fasted, increased upon re-feeding, and were low in streptozotocin-treated insulin-deficient mice. Musclin mRNA expression was induced at late stage in the differentiation of C2C12 myocytes. In myocytes, insulin increased, while epinephrine, isoproterenol, and forskolin reduced musclin mRNA, all of which are known to increase the cellular content of cyclic AMP, a counter-regulator to insulin. Pathologically, overexpression of musclin mRNA was noted in the muscles of obese insulin-resistant KKAy mice. Functionally, recombinant musclin significantly attenuated insulin-stimulated glucose uptake and glycogen synthesis in myocytes. In conclusion, we identified musclin, a novel skeletal muscle-derived secretory factor. Musclin expression level is tightly regulated by nutritional changes and its physiological role could be linked to glucose metabolism.

Amino Acid Sequence↗

Optical tomographic mapping of cerebral haemodynamics by means of time-domain detection: methodology and phantom validation.

One of the primary applications of diffuse optical imaging is to localize and quantify the changes in the cerebral oxygenation during functional brain activation. Up to now, data from an optical imager are simply presented as a two-dimensional (2D) topographic map using the modified Beer-Lambert law that assumes homogeneous optical properties beneath each optode. Due to the highly heterogeneous nature of the optical properties in the brain, the assumption is evidently invalid, leading to both low spatial resolution and inaccurate quantification in the assessment of haemodynamic changes. To cope with these difficulties, we propose a nonlinear tomographic image reconstruction algorithm for a two-layered slab geometry that uses time-resolved reflected light. The algorithm is based on the previously developed generalized pulse spectrum technique, and implemented within a semi-three-dimensional (3D) framework to conform to the topographic visualization and to reduce computational load. We demonstrate the advantages of the algorithm in quantifying simulated changes in haemoglobin concentrations and investigate its robustness to the uncertainties in the cortical structure and optical properties, as well as the effects of random noises on image quality. The methodology is also validated by experiments using a solid layered phantom.

Algorithms↗

Surgical treatment for an atherosclerotic aneurysm of the superficial femoral artery: report of a case.

We report the case of an isolated atherosclerotic aneurysm of the superficial femoral artery (SFA). The patient was a 76-year-old man who presented with intermittent claudication and muscle weakness in his right leg. Angiography showed an aneurysm in the lower portion of the right SFA, but no abdominal aortic aneurysm or any other peripheral aneurysms were detected. The patient had not suffered any major complications such as rupture, thrombosis, or distal emboli by the time of presentation. Thus, we resected the aneurysm and replaced it with a Dacron graft. Pathological examination revealed typical atherosclerotic changes and no evidence of infection, previous injury, or connective tissue disorders. While isolated atherosclerotic aneurysms of the SFA are rare, with only about 30 cases documented, patients frequently present with major complications and therefore, making an early diagnosis and initiating appropriate surgical treatment are essential.

Aged↗

Spontaneous dissection and rupture of common iliac artery in a patient with fibromuscular dysplasia: a case report and review of the literature on iliac artery dissections secondary to fibromuscular dysplasia.

Spontaneous dissection and rupture of the iliac artery is an unusual finding in patients with fibromuscular dysplasia (FMD). We report the case of a patient with FMD who required emergent surgery because of rupture of an iliac artery dissection, and review 9 previously reported cases of iliac artery dissection associated with FMD. A 30-year-old man had abdominal pain, and went into shock. Angiograms revealed dissection of the left common iliac artery with extravasation. At emergent surgery the rupture site was in the proximal left common iliac artery and extended to the left external iliac artery. Interposition of the diseased artery with a Dacron graft was attempted, but cardiac arrest occurred, and resuscitation was unsuccessful. Pathologic examination showed typical characteristics of diffuse medial FMD. Ten cases (5 male and 5 female patients), including the present case, with dissection of iliac arteries associated with FMD have been reported. Median patient age was 45 years (range, 29-56 years). Three of the 10 patients had acute onset of symptoms, and the remainder had gradual development of intermittent claudication or groin pain. Only the present case had evidence of rupture. The site of dissection was in the external iliac artery in 8 patients and the common iliac artery in 2 patients. Anatomic bypass or interposition of the diseased artery was performed in 8 patients; the others received conservative treatment. There was no mortality in the 9 previously reported cases. Fatal acute dissection and rupture of the common iliac artery occurred in a patient with FMD, even though the clinical course of this disease is relatively benign. FMD should be considered the cause of dissection and rupture of the iliac artery in a patient with symptoms but of non-atherosclerotic age.

Adult↗

Increased oxidative stress in obesity and its impact on metabolic syndrome.

Obesity is a principal causative factor in the development of metabolic syndrome. Here we report that increased oxidative stress in accumulated fat is an important pathogenic mechanism of obesity-associated metabolic syndrome. Fat accumulation correlated with systemic oxidative stress in humans and mice. Production of ROS increased selectively in adipose tissue of obese mice, accompanied by augmented expression of NADPH oxidase and decreased expression of antioxidative enzymes. In cultured adipocytes, elevated levels of fatty acids increased oxidative stress via NADPH oxidase activation, and oxidative stress caused dysregulated production of adipocytokines (fat-derived hormones), including adiponectin, plasminogen activator inhibitor-1, IL-6, and monocyte chemotactic protein-1. Finally, in obese mice, treatment with NADPH oxidase inhibitor reduced ROS production in adipose tissue, attenuated the dysregulation of adipocytokines, and improved diabetes, hyperlipidemia, and hepatic steatosis. Collectively, our results suggest that increased oxidative stress in accumulated fat is an early instigator of metabolic syndrome and that the redox state in adipose tissue is a potentially useful therapeutic target for obesity-associated metabolic syndrome.

3T3-L1 Cells↗

Simulation study of in vitro glucose measurement by NIR spectroscopy and a method of error reduction.

The effects of some important factors on the blood glucose measurements by NIR spectroscopy are investigated by numerical simulation, and a method is proposed to significantly reduce the prediction errors induced by these effects. The changes in the absorbance spectra with the changes in the glucose concentration, temperature and scattering characteristics of background tissue are obtained by a Monte Carlo simulation of light propagation for the wavelength range from 1200 nm to 1800 nm. The glucose concentration is predicted by applying a multivariate analysis to the numerically simulated spectra. This process estimates the errors in the prediction of the glucose concentration induced by the temperature and scattering changes. It has been found that only 1 C change in the temperature or only 1% change in the scattering coefficient induces about 500 mg dl(-1) or 300 mg dl(-1) errors, respectively, in the prediction of the glucose concentration. These errors can be significantly reduced to less than 20 mg dl(-1) of the glucose concentration by incorporating the effects of the temperature and scattering characteristics on the spectra to the multivariate analysis.

Algorithms↗

Induction of intestinal ATP-binding cassette transporters by a phytosterol-derived liver X receptor agonist.

The nuclear receptors liver X receptor (LXR) alpha and LXRbeta serve as oxysterol receptors and regulate the expression of genes involved in lipid metabolism. LXR activation induces the expression of ATP-binding cassette (ABC) transporters, such as ABCG5 and ABCG8, which inhibit intestinal absorption of cholesterol and phytosterols. Although several synthetic LXR agonists have been generated, these compounds have limited clinical application, because they cause hypertriglycemia by inducing the expression of lipogenic genes in the liver. We synthesized derivatives of phytosterols and found some of them to act as LXR agonists. Among them, YT-32 [(22E)-ergost-22-ene-1alpha,3beta-diol], which is related to ergosterol and brassicasterol, is the most potent LXR agonist. YT-32 directly bound to LXRalpha and LXRbeta and induced the interaction of LXRalpha with cofactors, such as steroid receptor coactivator-1, as effectively as the natural ligands, 22(R)-hydroxycholesterol and 24(S),25-epoxycholesterol. Although the nonsteroidal synthetic LXR agonist T0901317 induced the expression of intestinal ABC transporters and liver lipogenic genes, oral administration of YT-32 selectively activated intestinal ABC transporters in mice. Unlike T0901317 treatment, YT-32 inhibited intestinal cholesterol absorption without increasing plasma triglyceride levels. The phytosterol-derived LXR agonist YT-32 might selectively modulate intestinal cholesterol metabolism.

ATP-Binding Cassette Transporters↗

Solution of the time-dependent diffusion equation for layered diffusive media by the eigenfunction method.

An exact solution of the time-dependent diffusion equation for the case of a two- and a three-layered finite diffusive medium is proposed. The method is based on the decomposition of the fluence rate in a series of eigenfunctions and upon the solution of the consequent transcendental equation for the eigenvalues obtained from the boundary conditions. Comparisons among the solution of the diffusion equation and the results of Monte Carlo simulations show the correctness of the proposed model.

Journal Article↗

Treatment of nevus using medical tattooing.

Medical tattooing is used to color skin with a pigment loss. Currently, however, a trial-and-error scheme is employed to obtain the desired color appearance of tattooed skin because prediction of the color appearance is dependent on the experiences of medical doctors. We propose a method for predicting the color appearance of tattooed skin. Two trial dyes are first injected in the area of pigment loss, and the color appearance of a third dye to be injected can be predicted using measured spectrocolorimeter data and mathematical formula. The spectrocolorimeter measures the color appearances of the skin before and after tattooing using the first two dyes, and the mathematical formula calculates the color appearance of the tattooed skin using any third dye. In the derivation of the mathematical formula, light propagation in the skin has been modeled using the modified Lambert-Beer law considering the strong scattering of light by biological tissues. The proposed method was successfully validated by a preliminary tattooing of the skin to an area with pigment loss. Predicting the color appearance of tattooed skin significantly reduces the number of trial-and-error attempts required in the current methods. Medical tattooing using this method can also be applied to treat various skin color abnormalities such as leukoderma, intradermal nevi, and reconstructed nipples.

Colorimetry↗