Search PubMed⌕ Search

Biomedical subjects

Yufeng Shen

Publications and source records attributed to Yufeng Shen.

At least 19 recordsLinked to original sources

Mitochondrial Lon Peptidase 1 Controls Diaphragm and Lung Development in a Context-Dependent Manner.

Congenital Diaphragmatic Hernia (CDH) is a rare neonatal disorder causing diaphragmatic defects and cardiopulmonary hypoplasia, traditionally attributed to mechanical compression from organ herniation. However, emerging evidence suggests genetic mutations may independently impair lung development, prompting debate over CDH etiology. Here, we investigated the requirement of mitochondrial function guarded by LON peptidase 1 (Lonp1), a CDH risk gene, in either diaphragm or lung development. Lonp1 loss in skeletal muscles of the diaphragm led to its thinning and membranization, recapitulating the pathology of sac-type CDH. On the other hand, lung-specific inactivation caused severe hypoplasia with defective branching morphogenesis, independent of diaphragm anomalies. Molecularly, Lonp1 disruption dysregulated key transcription factors and signaling pathways known to be critical for early lung development. Our findings here revealed that mitochondrial defects contribute to the pathogenesis of CDH in an organ and cell type specific manner, opening new avenues for drug and therapeutic development.

CDH↗

The genome of the sea urchin Strongylocentrotus purpuratus.

We report the sequence and analysis of the 814-megabase genome of the sea urchin Strongylocentrotus purpuratus, a model for developmental and systems biology. The sequencing strategy combined whole-genome shotgun and bacterial artificial chromosome (BAC) sequences. This use of BAC clones, aided by a pooling strategy, overcame difficulties associated with high heterozygosity of the genome. The genome encodes about 23,300 genes, including many previously thought to be vertebrate innovations or known only outside the deuterostomes. This echinoderm genome provides an evolutionary outgroup for the chordates and yields insights into the evolution of deuterostomes.

Animals↗

Shedding genomic light on Aristotle's lantern.

Sea urchins have proved fascinating to biologists since the time of Aristotle who compared the appearance of their bony mouth structure to a lantern in The History of Animals. Throughout modern times it has been a model system for research in developmental biology. Now, the genome of the sea urchin Strongylocentrotus purpuratus is the first echinoderm genome to be sequenced. A high quality draft sequence assembly was produced using the Atlas assembler to combine whole genome shotgun sequences with sequences from a collection of BACs selected to form a minimal tiling path along the genome. A formidable challenge was presented by the high degree of heterozygosity between the two haplotypes of the selected male representative of this marine organism. This was overcome by use of the BAC tiling path backbone, in which each BAC represents a single haplotype, as well as by improvements in the Atlas software. Another innovation introduced in this project was the sequencing of pools of tiling path BACs rather than individual BAC sequencing. The Clone-Array Pooled Shotgun Strategy greatly reduced the cost and time devoted to preparing shotgun libraries from BAC clones. The genome sequence was analyzed with several gene prediction methods to produce a comprehensive gene list that was then manually refined and annotated by a volunteer team of sea urchin experts. This latter annotation community edited over 9000 gene models and uncovered many unexpected aspects of the sea urchin genetic content impacting transcriptional regulation, immunology, sensory perception, and an organism's development. Analysis of the basic deuterostome genetic complement supports the sea urchin's role as a model system for deuterostome and, by extension, chordate development.

Animals↗

Ultra-sensitive and quantitative characterization of proteomes.

Electrospray ionization mass spectrometry combined with high efficiency capillary liquid chromatography provides high sensitivity and broad dynamic range measurements for the characterization of biological macromolecules in complex matrices, and is an increasingly powerful analytical tool for systems biology research.

Animals↗

Differential label-free quantitative proteomic analysis of Shewanella oneidensis cultured under aerobic and suboxic conditions by accurate mass and time tag approach.

We describe the application of LC-MS without the use of stable isotope labeling for differential quantitative proteomic analysis of whole cell lysates of Shewanella oneidensis MR-1 cultured under aerobic and suboxic conditions. LC-MS/MS was used to initially identify peptide sequences, and LC-FTICR was used to confirm these identifications as well as measure relative peptide abundances. 2343 peptides covering 668 proteins were identified with high confidence and quantified. Among these proteins, a subset of 56 changed significantly using statistical approaches such as statistical analysis of microarrays, whereas another subset of 56 that were annotated as performing housekeeping functions remained essentially unchanged in relative abundance. Numerous proteins involved in anaerobic energy metabolism exhibited up to a 10-fold increase in relative abundance when S. oneidensis was transitioned from aerobic to suboxic conditions.

Amino Acid Sequence↗

More sensitive and quantitative proteomic measurements using very low flow rate porous silica monolithic LC columns with electrospray ionization-mass spectrometry.

The sensitivity of proteomics measurements using liquid chromatography (LC) separations interfaced with electrospray ionization-mass spectrometry (ESI-MS) improves approximately inversely with liquid flow rate (for the columns having the same separation efficiency, linear velocity, and porosity), making attractive the use of smaller inner diameter LC columns. We report the development and initial application of 10 microm i.d. silica-based monolithic LC columns providing more sensitive proteomics measurements. A 50-microm-i.d. micro solid-phase extraction precolumn was used for ease of sample injection and cleanup prior to the reversed-phase LC separation, enabling the sample volume loading speed to be increased by approximately 50-fold. Greater than 10-fold improvement in sensitivity was obtained compared to analyses using more conventional capillary LC, enabling e.g. the identification of >5000 different peptides by MS/MS from 100-ng of a Shewanella oneidensis tryptic digest using an ion trap MS. The low nL/min LC flow rates provide more uniform responses for different peptides, and provided improved quantitative measurements compared to conventional separation systems without the use of internal standards or isotopic labeling. The improved sensitivity allowed LC-MS measurements of immunopurified protein phosphatase 5 that were in good agreement with quantitative Western blot analyses.

Amino Acid Sequence↗

Making broad proteome protein measurements in 1-5 min using high-speed RPLC separations and high-accuracy mass measurements.

The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both time-of-flight (TOF) and Fourier transform ion cyclotron resonance (FTICR) MS were applied for identifying peptides using the accurate mass and time (AMT) tag approach. Peptide RPLC relative retention (elution) times that were generated by solvent gradients that differed by at least 25-fold were found to provide relative elution times that agreed to within 5%, which provides the basis for using peptide AMT tags for higher throughput proteomics measurements. For fast MS acquisition speeds (e.g., 0.2 s for TOF and either approximately 0.3 or approximately 0.6 s for FTICR), peptide mass measurement accuracies of better than +/-15 ppm were obtained with the high-speed RPLC separations. The ability to identify peptides and the overall proteome coverage was determined by factors that include the separation peak capacity, the sensitivity of the MS (with fast scanning), and the accuracy of both the mass measurements and the relative RPLC peptide elution times. The experimental RPLC relative elution time accuracies of 5% (using high-speed capillary RPLC) and mass measurement accuracies of better than +/-15 ppm allowed for the confident identification of >2800 peptides and >760 proteins from >13,000 different putative peptides detected from a Shewanellaoneidensis tryptic digest. Initial results for both RPLC-ESI-TOF and RPLC-ESI-FTICR MS were similar, with approximately 2000 different peptides from approximately 600 different proteins identified within 2-3 min. For <120-s proteomic analysis, TOF MS analyses were more effective, while FTICR MS was more effective for the >150-s analysis due to the improved mass accuracies attained using longer spectrum acquisition times.

Animals↗

Ultrahigh-throughput proteomics using fast RPLC separations with ESI-MS/MS.

We describe approaches for proteomics analysis using electrospray ionization-tandem mass spectrometry coupled with fast reversed-phase liquid chromatography (RPLC) separations. The RPLC separations used 50-microm-i.d. fused-silica capillaries packed with submicrometer-sized C18-bonded porous silica particles and achieved peak capacities of 130-420 for analytes from proteome tryptic digests. When these separations were combined with linear ion trap tandem mass spectrometry measurements, approximately 1000 proteins could be identified in 50 min from approximately 4000 identified tryptic peptides; approximately 550 proteins in 20 min from approximately 1800 peptides; and approximately 250 proteins in 8 min from approximately 700 peptides for a S. oneidensis tryptic digest. The dynamic range for protein identification with the fast separations was determined to be approximately 3-4 orders of magnitude of relative protein abundance on the basis of known proteins in human blood plasma analyses. We found that 55% of the MS/MS spectra acquired during the entire analysis (and up to 100% of the MS/MS spectra acquired from the most data-rich zone) provided sufficient quality for identifying peptides. The results confirm that such analyses using very fast (minutes) RPLC separations based on columns packed with microsized porous particles are primarily limited by the MS/MS analysis speed.

Chromatography, High Pressure Liquid↗

Preparation of 20-microm-i.d. silica-based monolithic columns and their performance for proteomics analyses.

We describe the preparation and performance of high-efficiency 70 cm x 20 microm i.d. silica-based monolithic capillary LC columns. The monolithic columns at a mobile-phase pressure of 5000 psi provide flow rates of approximately 40 nL/min at a linear velocity of approximately 0.24 cm/s. The columns provide a separation peak capacity of approximately 420 in conjunction with both on-line coupling with microsolid-phase extraction and nanoelectrospray ionization-mass spectrometry. Performance was evaluated using a Shewanella oneidensis tryptic digest, and approximately 15-amol detection limits for peptides were obtained using a conventional ion trap and MS/MS for peptide identification. The sensitivity and separation efficiency enabled the identification of 2367 different peptides covering 855 distinct S. oneidensis proteins from a 2.5-microg tryptic digest sample in a single 10-h analysis. The number of identified peptides and proteins approximately doubled when the effective separation time was extended from 200 to 600 min. The number of identified peptides increased from 32 to 390 as the injection amount was increased from 0.5 to 100 ng. Both the run-to-run and column-to-column reproducibility for proteomic analyses were also evaluated.

Chromatography, Liquid↗

Automated 20 kpsi RPLC-MS and MS/MS with chromatographic peak capacities of 1000-1500 and capabilities in proteomics and metabolomics.

Proteomics analysis based-on reversed-phase liquid chromatography (RPLC) is widely practiced; however, variations providing cutting-edge RPLC performance have generally not been adopted even though their benefits are well established. Here, we describe an automated format 20 kpsi RPLC system for proteomics and metabolomics that includes on-line coupling of micro-solid phase extraction for sample loading and allows electrospray ionization emitters to be readily replaced. The system uses 50 microm i.d. x 40-200 cm fused-silica capillaries packed with 1.4-3-microm porous C18-bonded silica particles to obtain chromatographic peak capacities of 1000-1500 for complex peptide and metabolite mixtures. This separation quality provided high-confidence identifications of >12 000 different tryptic peptides from >2000 distinct Shewanella oneidensis proteins (approximately 40% of the proteins predicted for the S. oneidensis proteome) in a single 12-h ion trap tandem mass spectrometry (MS/MS) analysis. The protein identification reproducibility approached 90% between replicate experiments. The average protein MS/MS identification rate exceeded 10 proteins/min, and 1207 proteins were identified in 120 min through assignment of 5944 different peptides. The proteomic analysis dynamic range of the 20 kpsi RPLC-ion trap MS/MS was approximately 10(6) based on analyses of a human blood plasma sample, for which 835 distinct proteins were identified with high confidence in a single 12-h run. A single run of the 20 kpsi RPLC-accurate mass MS detected >5000 different compounds from a metabolomics sample.

Automation↗

Quantitative proteome analysis of human plasma following in vivo lipopolysaccharide administration using 16O/18O labeling and the accurate mass and time tag approach.

Identification of novel diagnostic or therapeutic biomarkers from human blood plasma would benefit significantly from quantitative measurements of the proteome constituents over a range of physiological conditions. Herein we describe an initial demonstration of proteome-wide quantitative analysis of human plasma. The approach utilizes postdigestion trypsin-catalyzed 16O/18O peptide labeling, two-dimensional LC-FTICR mass spectrometry, and the accurate mass and time (AMT) tag strategy to identify and quantify peptides/proteins from complex samples. A peptide accurate mass and LC elution time AMT tag data base was initially generated using MS/MS following extensive multidimensional LC separations to provide the basis for subsequent peptide identifications. The AMT tag data base contains >8,000 putative identified peptides, providing 938 confident plasma protein identifications. The quantitative approach was applied without depletion of high abundance proteins for comparative analyses of plasma samples from an individual prior to and 9 h after lipopolysaccharide (LPS) administration. Accurate quantification of changes in protein abundance was demonstrated by both 1:1 labeling of control plasma and the comparison between the plasma samples following LPS administration. A total of 429 distinct plasma proteins were quantified from the comparative analyses, and the protein abundances for 25 proteins, including several known inflammatory response mediators, were observed to change significantly following LPS administration.

Blood Proteins↗

Targeted comparative proteomics by liquid chromatography-tandem Fourier ion cyclotron resonance mass spectrometry.

In proteomics, effective methods are needed for identifying the relatively limited subset of proteins displaying significant changes in abundance between two samples. One way to accomplish this task is to target for identification by MS/MS only the "interesting" proteins based on the abundance ratio of isotopically labeled pairs of peptides. We have developed the software and hardware tools for online LC-FTICR MS/MS studies in which a set of initially unidentified peptides from a proteome analysis can be selected for identification based on their distinctive changes in abundance following a "perturbation". We report here the validation of this method using a mixture of standard proteins combined in different ratios after isotopic labeling. We also demonstrate the application of this method to the identification of Shewanella oneidensis peptides/proteins exhibiting differential abundance in suboxic versus aerobic cell cultures.

Bacterial Proteins↗

Characterization of the human blood plasma proteome.

We describe methods for broad characterization of the human plasma proteome. The combination of stepwise immunoglobulin G (IgG) and albumin protein depletion by affinity chromatography and ultrahigh-efficiency capillary liquid chromatography separations coupled to ion trap-tandem mass spectrometry enabled identification of 2392 proteins from a single plasma sample with an estimated confidence level of > 94%, and an additional 2198 proteins with an estimated confidence level of 80%. The relative abundances of the identified proteins span a range of over eight orders of magnitude in concentration (< 30 pg/mL to approximately 30 mg/mL), facilitated by the attomole-level sensitivity of the analysis methods. More than 80% of the observed proteins demonstrate interactions with IgG and/or albumin, and the human plasma protein loss in the affinity chromatography/strong cation exchange/reversed-phase liquid chromatography-tandem mass spectrometry methodology was investigated in detail. The results of this study provide a basis for a wide range of plasma proteomics studies, including broad quantitation of relative abundances in comparative studies of the identification of novel protein disease markers, as well as further studies of protein-protein interactions.

Animals↗

A proteomic study of the HUPO Plasma Proteome Project's pilot samples using an accurate mass and time tag strategy.

Characterization of the human blood plasma proteome is critical to the discovery of routinely useful clinical biomarkers. We used an accurate mass and time (AMT) tag strategy with high-resolution mass accuracy cLC-FT-ICR MS to perform a global proteomic analysis of pilot study samples as part of the HUPO Plasma Proteome Project. HUPO reference serum and citrated plasma samples from African Americans, Asian Americans, and Caucasian Americans were analyzed, in addition to a Pacific Northwest National Laboratory reference serum and plasma. The AMT tag strategy allowed us to leverage two previously published "shotgun" proteomics experiments to perform global analyses on these samples in triplicate in less than 4 days total analysis time. A total of 722 (22% with multiple peptide identifications) International Protein Index redundant proteins, or 377 protein families by ProteinProphet, were identified over the six individual HUPO serum and plasma samples. The samples yielded a similar number of identified redundant proteins in the plasma samples (average 446 +/- 23) as found in the serum samples (average 440 +/- 20). These proteins were identified by an average of 956 +/- 35 unique peptides in plasma and 930 +/- 11 unique peptides in serum. In addition to this high-throughput analysis, the AMT tag approach was used with a Z-score normalization to compare relative protein abundances. This analysis highlighted both known differences in serum and citrated plasma such as fibrinogens, and reproducible differences in peptide abundances from proteins such as soluble activin receptor-like kinase 7b and glycoprotein m6b. The AMT tag strategy not only improved our sample throughput but also provided a basis for estimated quantitation.

Blood Proteins↗

Advanced nanoscale separations and mass spectrometry for sensitive high-throughput proteomics.

Recent developments in combined separations with mass spectrometry for sensitive and high-throughput proteomic analyses are reviewed herein. These developments primarily involve high-efficiency (separation peak capacities of approximately 10(3)) nanoscale liquid chromatography (flow rates extending down to approximately 20 nl/min at optimal liquid mobile-phase separation linear velocities through narrow packed capillaries) in combination with advanced mass spectrometry and in particular, high-sensitivity and high-resolution Fourier transform ion cyclotron resonance mass spectrometry. Such approaches enable analysis of low nanogram level proteomic samples (i.e., nanoscale proteomics) with individual protein identification sensitivity at the low zeptomole level. The resultant protein measurement dynamic range can approach 10(6) for nanogram-sized proteomic samples, while more abundant proteins can be detected from subpicogram-sized (total) proteome samples. These qualities provide the foundation for proteomics studies of single or small populations of cells. The instrumental robustness required for automation and providing high-quality routine performance nanoscale proteomic analyses is also discussed.

Chromatography, Liquid↗

Ultra-high-efficiency strong cation exchange LC/RPLC/MS/MS for high dynamic range characterization of the human plasma proteome.

High-efficiency nanoscale reversed-phase liquid chromatography (chromatographic peak capacities of approximately 1000: Shen, Y.; Zhao, R.; Berger, S. J.; Anderson, G. A.; Rodriguez, N.; Smith, R. D. Anal. Chem. 2002, 74, 4235. Shen, Y.; Moore, R. J.; Zhao, R.; Blonder, J.; Auberry, D. L.; Masselon, C.; Pasa-Tolic, L.; Hixson, K. K.; Auberry, K. J.; Smith, R. D. Anal. Chem. 2003, 75, 3596.) and strong cation exchange LC was used to obtain ultra-high-efficiency separations (combined chromatographic peak capacities of >10(4)) in conjunction with tandem mass spectrometry (MS/MS) for characterization of the human plasma proteome. Using conservative SEQUEST peptide identification criteria (i.e., without considering chymotryptic or elastic peptides) and peptide LC normalized elution time constraints, the separation quality enabled the identification of proteins over a dynamic range of greater than 8 orders of magnitude in relative abundance using ion trap MS/MS instrumentation. Between 800 and 1682 human proteins were identified, depending on the criteria used for identification, from a total of 365 microg of human plasma. The analyses identified relatively low-level (approximately pg/mL) proteins (e.g., cytokines) coexisting with high-abundance proteins (e.g., mg/mL-level serum albumin).

Amino Acid Sequence↗

Ultrasensitive proteomics using high-efficiency on-line micro-SPE-nanoLC-nanoESI MS and MS/MS.

Ultrasensitive nanoscale proteomics approaches for characterizing proteins from complex proteomic samples of <50 ng of total mass are described. Protein identifications from 0.5 pg of whole proteome extracts were enabled by ultrahigh sensitivity (<75 zmol for individual proteins) achieved using high-efficiency (peak capacities of approximately 10(3)) 15-microm-i.d. capillary liquid chromatography separations (i.e., using nanoLC, approximately 20 nL/min mobile-phase flow rate at the optimal linear velocity of approximately 0.2 cm/s) coupled on-line with a micro-solid-phase sample extraction and a nanoscale electrospray ionization interface to a 11.4-T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (MS). Proteome measurement coverage improved as sample size was increased from as little as 0.5 pg of sample. It was found that a 2.5-ng sample provided 14% coverage of all annotated open reading frames for the microorganism Deinococcus radiodurans, consistent with previous results for a specific culture condition. The estimated detection dynamic range for detected proteins was 10(5)-10(6). An improved accurate mass and LC elution time two-dimensional data analysis methodology, used to both speed and increase the confidence of peptide/protein identifications, enabled identification of 872 proteins/run from a single 3-h nanoLC/FTICR MS analysis. The low-zeptomole-level sensitivity provides a basis for extending proteomics studies to smaller cell populations and potentially to a single mammalian cell. Application with ion trap MS/MS instrumentation allowed protein identification from 50 pg (total mass) of proteomic samples (i.e., approximately 100 times larger than FTICR MS), corresponding to a sensitivity of approximately 7 amol for individual proteins. Compared with single-stage FTICR measurements, ion trap MS/MS provided a much lower proteome measurement coverage and dynamic range for a given analysis time and sample quantity.

Amino Acid Sequence↗

Ultrasensitive and quantitative analyses from combined separations-mass spectrometry for the characterization of proteomes.

This article describes developments in fundamental and applied aspects of separations, electrospray ionization phenomena, and mass spectrometric instrumentation that are interrelated and important for making more effective and quantitative measurements, particularly for proteomics applications. The basis for better quantitation and ultrahigh sensitivity is highlighted for high-resolution capillary liquid chromatography separations that provide low nanoliter per minute flow rates to an electrospray ionization interface. The increased dynamic range of measurements and low zeptomole regime detection limits obtainable open new avenues for biological research.

Chromatography, Liquid↗