Search PubMed⌕ Search

Biomedical subjects

Yu-Chie Chen

Publications and source records attributed to Yu-Chie Chen.

23 records · Page 2Linked to original sources

Laser desorption/ionization time-of-flight mass spectrometry on sol-gel-derived 2,5-dihydroxybenzoic acid film.

This work presents a novel method for direct desorption/ ionization of analytes from sol-gel-derived film. 2,5-Dihydroxy benzoic acid (DHB), a common MALDI matrix, was incorporated into a sol-gel polymeric structure. The sol-gel-derived DHB thin film can assist the mass analysis of analytes by laser desorption/ionization, with a matrix interference-free background in the mass spectra. The sol-gel-derived film can function as an energy absorber during laser irradiation because it contains DHB molecules. Furthermore, laser irradiation with normal laser power (70-110 microJ) is not likely to generate any background ions from this sol-gel-DHB derived film. The samples were prepared straightforwardly. After a thin film was formed on a Parafilm membrane from the sol-gel-derived DHB solution coating, the sample solution was directly added to the top of the film, for laser desorption/ ionization mass analysis. The analyte signals were homogeneously obtained on the sol-gel-derived DHB film. Experimental results show that the optimum concentrations of DHB incorporated in the sol-gel solution were between 7,500 ppm and 10,000 ppm, providing a matrix interference-free background. Analytes, including small proteins, peptides, amino acids, and small organics, were used to demonstrate the effectiveness of the proposed method. However, a higher laser power (> 110 microJ) than normal was required to desorb small proteins from the sol-gel-derived DHB film. Therefore, a few matrix ions desorbed from the thin film were generated during laser irradiation. The detection limit for both small molecules and proteins, using this sol-gel-assisted laser desorption/ ionization (SGALDI) mass spectrometry (MS), was as low as 81 fmol. However, a mass spectrometer with cutoff-mass selection could detect 8.1 fmol of cytochrome c. The largest analyte observed by the SGALDI-MS in this study was myoglobin.

Amino Acids↗

A novel approach of combining thin-layer chromatography with surface-assisted laser desorption/ionization (SALDI) time-of-flight mass spectrometry.

A novel means of combining thin-layer chromatography (TLC) with laser desorption/ionization mass spectrometry using a liquid matrix is proposed. Surface-assisted laser desorption/ionization (SALDI) mass spectrometry, which uses a mixture of a micrometer-sized carbon powder (graphite or activated carbon, the SALDI solid) and 15% sucrose/glycerol, dissolved in an equal volume of methanol (SALDI liquid) as a SALDI matrix, is used for laser desorption mass analysis. The ablation of carbon powder from a pencil drawing was used as an alternative to the SALDI solid. The liquid matrix resembled that used in a conventional SALDI matrix system. A line was drawn before separation with a pencil on the track of the sample developed on the TLC plate. After TLC separation, approximately 0.1 microl of SALDI liquid was directly applied to the chromatographic spots on the TLC plate. Porphyrins were used to demonstrate this combination owing to the visible colors of this type of compound. The analyte signal can be easily detected by irradiating the laser along the pencil line on the TLC plate. An additive, p-toluenesulfonic acid, is added to the SALDI liquid to enhance the signal's intensity. This additive dramatically improves the signal-to-noise ratio. A detection limit of approximately 500 pg is demonstrated for porphines, which is 50 times better than that corresponding to conventional TLC SALDI.

Journal Article↗

Analysis of the saliva from patients with oral cancer by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), this study analyzed the saliva obtained from patients with oral cancer and compared these mass spectra with those obtained from healthy controls. Saliva without pre-treatment was mixed directly with a sinapinic acid matrix. Alpha-amylase (57 kDa) dominated the high mass range in the MALDI mass spectra of the saliva from healthy subjects, but the peak was suppressed for patients with oral cancer and was replaced by a peak at m/z 66 k in the spectra of patients' samples (15 out of 20). Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) with in-gel tryptic digestion combined with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) was employed to characterize this 66-kDa protein, which was thus shown to be albumin. However, based on SDS-PAGE results, concentrations of both alpha-amylase and albumin in patients' saliva were significantly higher than those in healthy subjects. This discrepancy was shown to be due to MALDI suppression effects due to the albumin. MALDI-MS thus has potential as a possible rapid diagnostic screening tool for oral cancer.

Adult↗