Search PubMed⌕ Search

Biomedical subjects

Young Koog Cheon

Publications and source records attributed to Young Koog Cheon.

15 recordsLinked to original sources

Identification of risk factors for stone recurrence after endoscopic treatment of bile duct stones.

Recurrence of bile duct stones after endoscopic stone removal has been reported ranging from 4 to 24%. The risk of late complications such as stone recurrence is an important issue, especially for relatively young, otherwise healthy, patients with many years of future exposure time. The risk factors true recurrence of bile duct stones after endoscopic sphincterotomy (EST) and stone clearance are suboptimally defined. If patients at significant risk for stone recurrence could be identified, closer follow-up, earlier intervention, and possible preventive measures could theoretically decrease stone recurrence and late complications. The majority of patients with common bile duct stone who have EST and stone clearance will have no further biliary events during the remainder of their life. Whether identifying risk factors for recurrence can improve outcomes by prophylactic treatments or earlier interventions needs further prospective study.

Cholangiopancreatography, Endoscopic Retrograde↗

[Detection of Intrahepatic HBV DNA in HBsAg-negative liver diseases].

BACKGROUNDS/AIMS: Occult HBV infection is characterized by the presence of HBV infection with undetectable HBsAg. This study was carried out to find out the frequency of HBV infection in HBsAg- negative patients. METHODS: Fifty-six HBsAg-negative patients including 17 anti-HCV positive patients were evaluated. Patients were grouped according to their serological status; group A (anti-HBc+, anti-HBs-, n=16), B (anti-HBc+, anti-HBs+, n=26), and C (anti-HBc-, anti-HBs+/-, n=14). DNA was extracted from frozen liver biopsy specimen, and HBV DNA level was measured with real-time PCR. RESULTS: Overall frequency of detectable intrahepatic HBV DNA was 34% (19/56). The frequency was 56% (9/16) in group A, 31% (8/26) in group B and 14% (2/14) in group C (P=0.01). Intrahepatic HBV DNA levels were as follows; 2,010 +/- 6,660 copies/mg in group A, 6,180 +/- 29,530 copies/mg in group B and 350 +/- 1,220 copies/mg in group C. The frequency of occult HBV infection was not increased in anti-HCV positive patients. CONCLUSIONS: Intrahepatic HBV DNA is frequently detected in anti-HBc positive, HBsAg-negative patients, although the concentration is low.

Adult↗

[A case of complete regression of hepatocellular carcinoma during administration of COX-2 inhibitor].

Overexpression of cyclooxygenase-2 (COX-2) has been associated with hepatocarcinogenesis. Inhibitors of COX-2 have proapoptotic and antiproliferative effects on malignant tumors and inhibit tumor invasion to the surrounding tissues. We report here a case of complete regression of advanced hepatocellular carcinoma (HCC) during COX-2 inhibitor administration. An eighty-year-old female was diagnosed as an advanced HCC, which was associated with HCV infection. She received COX-2 inhibitor for 3 months due to degenerative arthritis of both knees. Tumor enhancement on arterial phase CT completely disappeared without specific treatment for the HCC, and the tumor size decreased on the follow-up CT scan.

Aged, 80 and over↗

Wire-guided endoscopic snare papillectomy for tumors of the major duodenal papilla.

BACKGROUND: Endoscopic excision for adenoma of the major duodenal papilla was introduced as an alternative to surgery, but postprocedure pancreatitis is a serious drawback. This study assessed the feasibility and the safety of endoscopic papillectomy with a guidewire and pancreatic-duct stent insertion to prevent pancreatitis. METHODS: Six patients were enrolled. The snare loop was passed over a guidewire that had been inserted into the pancreatic duct. Immediately after snare resection, a pancreatic stent was placed along the indwelling guidewire. RESULTS: En bloc papillectomy and pancreatic stent insertion were performed successfully in all patients. Pancreatitis did not develop acutely in any patient. Complications included cholangitis (n = 1) and late-onset pancreatitis owing to the pancreatic stent (n = 1). Scant residual adenomatous tissue was present at resection margins in two patients and was treated endoscopically. CONCLUSIONS: Wire-guided endoscopic snare papillectomy in selected patients is a useful technique that maintains pancreatic-duct access for stent placement. This appears to prevent pancreatitis and to improve the outcome for patients undergoing endoscopic resection of papillary tumors.

Adult↗

The detection of bile duct stones in suspected biliary pancreatitis: comparison of MRCP, ERCP, and intraductal US.

OBJECTIVES: Early ERCP and endoscopic sphincterotomy for stone extraction can benefit the prognosis in patients with severe biliary pancreatitis, but are associated with complications. The ability to identify choledocholithiasis by noninvasive means in biliary pancreatitis is limited. The aim of this study was evaluation of the ability of MRCP to detect choledocholithiasis in patients with acute biliary pancreatitis. In addition, we investigated whether intraductal US (IDUS) could help manage these patients. METHODS: Thirty-two patients with suspected biliary pancreatitis were studied prospectively. MRCP was performed immediately before ERCP by separate blinded examiners within 24 h of admission. Wire-guided IDUS was performed during ERCP within 72 h of admission, regardless of the results of MRCP. Using endoscopic extraction of a stone as the reference standard, the diagnostic yield of MRCP was compared with transabdominal US, CT, ERCP, and IDUS. RESULTS: The sensitivity of US, CT, MRCP, ERCP, and IDUS for identifying choledocholithiasis was 20.0%, 40.0%, 80.0%, 90.0%, and 95.0%, respectively. The overall agreement between MRCP and ERCP was 90.6% for choledocholithiasis (kappa= 0.808, p < 0.01). The sensitivity of MRCP for detecting choledocholithiasis decreased with dilated bile ducts (bile duct diameter > 10 mm, 72.7% vs 88.9%). The combination of ERCP and IDUS improved accuracy in the diagnosis of choledocholithiasis. CONCLUSIONS: MRCP can be used to select patients with biliary pancreatitis who require ERCP. IDUS may be applied in the management of biliary pancreatitis if ERCP is performed.

Adult↗

[A common bile duct web in association with common bile duct stone].

Webs are diagnosed by their characteristic appearance on imaging studies, typically appearing as thin, radiolucent rings with or without dilatation of the organ proximal to it. Like in other organs, the etiology of webs in the common bile duct is controversial. Some webs are thought to be congenital, whereas others occur in the presence of chronic inflammation, suggesting a pathogenic relationship. We report a case of a common bile duct septum in association with numerous large black pigment stones in a 62-year-old woman. The patient was treated by cholecystectomy with T-tube insertion.

Cholangiopancreatography, Endoscopic Retrograde↗

Endoscopic treatment of retained bile-duct stones by using a balloon catheter for electrohydraulic lithotripsy without cholangioscopy.

BACKGROUND: Electrohydraulic lithotripsy is a highly effective method for fragmenting biliary stones, but direct visual control is required. The efficacy and the safety of electrohydraulic lithotripsy without cholangioscopy by using a balloon catheter were evaluated in patients with bile-duct stones that could not be extracted by using standard techniques. METHODS: Nineteen patients with extrahepatic bile-duct stones that could not be extracted by using conventional endoscopic methods, e.g., mechanical lithotripsy, were selected to undergo electrohydraulic lithotripsy without peroral cholangioscopy. An electrohydraulic lithotripsy probe with a 3.0 F radio-opaque tip was inserted through a balloon catheter. Electrohydraulic lithotripsy was performed under fluoroscopy until the fragmented stone could be captured in a large basket for mechanical lithotripsy. Endoscopic removal of the fragments was attempted during the electrohydraulic lithotripsy session. RESULTS: Stones were successfully fragmented in 17 of 19 patients. In 16 patients (84.2%), the bile duct was cleared of all stones. A mean of 1.8 endoscopic sessions was required for complete removal. Additional mechanical lithotripsy was performed in 9 (56.2%) of the 16 patients. Minor complications were noted in 4 patients (2 hemobilia, 1 pancreatitis, 1 cholangitis). There was no 30-day mortality. CONCLUSIONS: For a selected group of patients with bile-duct stones not extractable by using standard techniques, fluoroscopically controlled electrohydraulic lithotripsy with a balloon catheter seems to be an effective method of fragmentation.

Adult↗

[Comparison of survival of advanced hilar cholangiocarcinoma after biliary drainage alone versus photodynamic therapy with external drainage].

BACKGROUND/AIMS: Photodynamic therapy (PDT) has a promising effect on non-resectable hilar cholangiocarcinoma. The aim of this study was to compare overall survival of PDT plus biliary drainage versus biliary stent alone in advanced hilar cholangiocarcinoma. METHODS: Twenty patients who were treated with endoscopic biliary drainage alone (Group A) and 27 patients treated with PDT under percutaneous cholangioscopy and additional percutaneous biliary drainage (Group B) were analyzed retrospectively. RESULTS: The mean bilirubin level declined effectively in both group after treatment. One-year survival was 28% in group A, 52% in group B (p<0.05). Median survival time was 288 days in group A, 558 days in group B (p=0.0143). CONCLUSIONS: PDT under percutaneous cholangioscopy seems to be more effective in extending survival than biliary drainage alone in advanced hilar tumor. To investigate whether PDT can increase survival rates, further prospective, randomized study is needed.

Aged↗

A spontaneously ruptured gastric stromal tumor with cystic degeneration presenting as hemoperitoneum: a case report.

We report a case of a 38-yr-old man with a spontaneously ruptured gastric stromal tumor presenting as hemoperitoneum in outpatient clinic. He visited our hospital with generalized abdominal pain after abdominal CT scan for the evaluation of the asymptomatic palpable abdominal mass. Repeated abdominal CT scan showed a size decrement of cystic mass compared with the previous abdominal CT scan, and newly developed fluid collection in the left paracolic gutter. An emergency laparotomy revealed a ruptured gastric stromal tumor with bloody fluid in the peritoneal cavity. Immunohistochemical examination revealed positive reactivity to C-kit protein and CD34. The patient presented with hemoperitoneum due to spontaneous rupture of the tumor, which is an extremely rare complication.

Adult↗

Use of detachable snares and elastic bands for endoscopic control of bleeding from large gastric varices.

BACKGROUND: Bleeding from gastric varices larger than 2 cm in diameter represents a major limitation for endoscopic hemostasis. METHODS: Endoscopic ligation of gastric varices was performed with detachable snares and elastic bands in 41 patients who had recent bleeding from gastric varices larger than 2 cm in diameter. Gastric varices larger than 2 cm were ligated with detachable snares, and then adjacent small gastric varices were ligated with elastic bands. RESULTS: Among the 41 patients, 10 of 12 patients with active bleeding and 28 of 29 patients with red color signs at initial endoscopy were successfully treated by endoscopic ligation by using detachable snares and elastic bands. Bleeding recurred early (before variceal eradication) in 4 of 38 patients (10.5%). The overall hemostatic rate for endoscopic ligation was 82.9% (34/41). In 33 of 36 patients (91.7%) who underwent repeated ligation treatments, variceal eradication was nearly complete. Mean follow-up in 30 of 33 patients after eradication of varices was 16.4 months (3-32 months), and 29 of 30 did not have recurrent bleeding. During and after ligation there were no serious complications. CONCLUSIONS: Endoscopic ligation therapy with large detachable snares and elastic bands is safe and effective for treatment of large bleeding gastric varices.

Acute Disease↗

Wire-guided intraductal US in the assessment of bile duct strictures with Mirizzi syndrome-like features at ERCP.

BACKGROUND: Mirizzi syndrome refers to common hepatic duct obstruction caused by extrinsic compression that is usually from a stone impacted in the cystic duct. The utility of transpapillary intraductal US for assessment of biliary strictures with radiographic features of Mirizzi syndrome was studied retrospectively. METHODS: Intraductal US was performed in 16 patients with a common hepatic duct stricture caused by extrinsic compression and nonvisualization of the gallbladder by endoscopic retrograde cholangiography. An over-the-wire catheter US probe (20 MHz) was inserted into the bile duct. Intraductal US findings were compared with the final diagnoses at surgery. RESULTS: Intraductal US was successful in all patients. The extraluminal cause of the common hepatic duct stricture was detected in 14 patients (87.5%). In 9 patients, intraductal US detected an impacted stone outside the common hepatic duct. Intraductal US demonstrated extraluminal lesions without evidence of a stone in 5 patients, including a mass in 4 and asymmetrical, irregular thickening of the bile duct wall in 1 patient. In the remaining 2 patients, intraductal US demonstrated only a distended gallbladder. CONCLUSIONS: Transpapillary wire-guided intraductal US is useful for assessing biliary strictures with features that suggest Mirizzi syndrome and optimizes management of patients with these findings.

Aged↗

Biliary metal stent as a nidus for bile duct stone.

Several cases of recurrent stone formation caused by a surgical material as a nidus have been reported. Recently, we experienced one case in which a migrated metal stent might have been served as a nidus for common duct stone formation. The diagnosis was confirmed by ERCP, the stone was successfully removed with endoscopic therapy. Six years ago, she had undergone a lithotripsy using a percutaneous cholangioscopy (PTCS) because of intrahepatic bile duct stones. Six years later, she developed abdominal pain in the right upper quadrant. ERCP revealed the dilated extrahepatic bile duct and left intrahepatic bile duct and the presence of a large elongated freely mobile filling defect suggestive of common bile duct stone containing metal mesh in the distal common bile duct. The removed stone with endoscopic sphincterotomy was soft and dark brown in color with metal stent.

Cholangiopancreatography, Endoscopic Retrograde↗