Search PubMed⌕ Search

Biomedical subjects

Yoshikatsu Akiyama

Publications and source records attributed to Yoshikatsu Akiyama.

6 recordsLinked to original sources

Thermal modulated interaction of aqueous steroids using polymer-grafted capillaries.

Poly(N-isopropylacrylamide) (PIPAAm) of controlled molecular weight was densely grafted onto glass capillary lumenal surfaces using surface-initiated atom transfer radical polymerization (ATRP). Temperature-dependent changes of these thermoresponsive brush surfaces with hydrophobic steroids were investigated by exploiting thermoresponsive aqueous wettability changes of the polymer-modified surfaces in microfluidic systems. IPAAm was polymerized on ATRP initiator-immobilized glass surfaces using CuCl/CuCl(2)/tris(dimethylaminoethyl)amine (Me(6)TREN) as an ATRP catalyst in water at 25 degrees C. PIPAAm graft layer thickness and its homogeneity on glass surfaces are controlled by changing ATRP reaction time. Aqueous wettability changes of PIPAAm-grafted surfaces responses drastically changed to both grafted polymer layer thickness and temperature, especially at lower temperatures. Temperature-responsive surface properties of these PIPAAm brushes within capillary inner wall surfaces were then investigated using capillary chromatography. Effective interaction of hydrophobic steroids with dehydrated, hydrophobized PIPAAm-grafted capillary surfaces was observed above 30 degrees C without any column packing materials. Steroid elution behavior from PIPAAm-grafted capillaries contrasted sharply with that from PIPAAm hydrogel-grafted porous monolithic silica capillaries prepared by electron beam (EB) irradiation wherein significant peak broadening was observed at high-temperature regardless of sample hydrophobicity factors (log P values), indicating multistep separation modes in coated monolithic silica capillaries. In conclusion, thermoresponsive polymer-grafted capillary inner wall surfaces prepared by ATRP exhibit useful temperature-dependent surface property alterations effective to regulate interactions with biomolecules without requirements for separation bed packing materials within the capillary lumen.

Journal Article↗

Fabrication of a cell array on ultrathin hydrophilic polymer gels utilising electron beam irradiation and UV excimer laser ablation.

Most of the surface patterning methods currently applied are based on lithography techniques and microfabrication onto silicon or glass substrates. Here we report a novel method to prepare patterned surfaces on polystyrene substrates by grafting ultrathin cell-repellent polymer layers utilising both electron beam (EB) polymerisation and local laser ablation techniques for microfabrication. Polyacrylamide was grafted onto tissue culture polystyrene (TCPS) dishes using EB irradiation. Water contact angles for these PAAm-grafted TCPS surfaces were less than 10 degrees (costheta = 0.99) with PAAm grafted amounts of 1.6 microg/cm(2) as determined by ATR/FT-IR. UV excimer laser (ArF: 193 nm) ablation resulted in the successful fabrication of micropatterned surfaces composed of hydrophilic PAAm and hydrophobic basal polystyrene layers. Bovine carotid artery endothelial cells adhered only to the ablated domains after pretreatment of the patterned surfaces with 15 microg/mL fibronectin at 37 degrees C. The ablated domain sizes significantly influenced the number of cells occupying each domain. Cell patterning functionality of the patterned surfaces was maintained for more than 2 months without loss of pattern fidelity, indicating that more durable cell arrays can be obtained compared to those prepared by self-assembled monolayers of alkanethiols, as described in previous reports. The surface fabrication techniques presented here can be utilised for the preparation of cell-based biosensors as well as tissue engineering constructs.

Acrylic Resins↗

Ultrathin poly(N-isopropylacrylamide) grafted layer on polystyrene surfaces for cell adhesion/detachment control.

We investigated physicochemical properties of two types of poly(N-isopropylacrylamide) (PIPAAm)-grafted tissue culture polystyrene (TCPS) surfaces, to elucidate the influential factors for thermally regulated cell adhesion and detachment to PIPAAm-grafted surfaces. The two types of PIPAAm-grafted surfaces were prepared by the electron beam polymerization method. Attenuated total reflection Fourier transform infrared spectroscopy revealed that amounts of the grafted polymers were 1.4 +/- 0.1 microg/cm2 for PIPAAm-1.4 and 2.9 +/- 0.1 microg/cm2 for PIPAAm-2.9. Both PIPAAm-grafted surfaces showed hydrophobic/hydrophilic property alterations in response to temperature. However, PIPAAm-1.4 surfaces were more hydrophobic (cos theta = 0.21 at 37 degrees C and cos theta = 0.35 at 20 degrees C) than PIPAAm-2.9 (cos theta = 0.42 at 37 degrees C and cos theta = 0.50 at 20 degrees C) both above and below the PIPAAm's transition temperature. Thicknesses of the grafted PIPAAm layers were estimated to be 15.5 +/- 7.2 nm for PIPAAm-1.4 and 29.5 +/- 8.4 nm for PIPAAm-2.9, by the use of UV excimer laser and atomic force microscope. Bovine carotid artery endothelial cells (ECs) adhere to the surfaces of PIPAAm-1.4 and proliferate to form confluent cell monolayers. The cell monolayers were harvested as single cell sheets by temperature decrease from 37 to 20 degrees C. On the contrary, ECs did not adhere to the surfaces of PIPAAm-2.9. This phenomenon was correlated with an adsorption of cell adhesion protein, fibronectin, onto surfaces ofPIPAAm-1.4 and -2.9. In the case of nano-ordered thin grafted surfaces, the surface chain mobility is strongly influenced by the thickness of PIPAAm grafted layers because dehydration of PIPAAm chains should be enhanced by the hydrophobic TCPS surfaces. PIPAAm graft amounts, that is, thickness of the PIPAAm grafted layers, play a crucial role in temperature-induced hydrophilic/hydrophobic property alterations and cell adhesion/detachment behavior.

Acrylamides↗

Affinity chromatography with collapsibly tethered ligands.

We introduce a novel affinity chromatography mode in which affinity ligands are secured to the media surface via collapsible tethers. In traditional affinity chromatography, the immobilized ligands act passively, and their local concentration is static. In collapsibly tethered affinity chromatography, the ligand can move dynamically in response to external stimuli, a design that enables marked changes in both the local concentration of the ligand and its surrounding environment without exchange of solvent. Using the thermoresponsive polymer poly(N-isopropylacrylamide) (PIPAAm) as a scaffold for ligand and hapten attachment, we were able to achieve controlled mobility and microenvironment alteration of the affinity ligand Ricinus communis agglutinin (RCA120). The glycoprotein target, asialotransferrin, was loaded onto a column in which PIPAAm was partially substituted with both RCA120 and lactose. At 5 degrees C, the column retained the glycoprotein, but released most (95%) of the asialotransferrin upon warming to 30 degrees C. This temperature-induced elution was much greater than can be explained by temperature dependency of sugar recognition by RCA120. The simplest explanation is that upon thermally induced dehydration and collapse of the PIPAAm chains, coimmobilized RCA120 ligand and lactose hapten are brought into closer proximity to each other, enabling immobilized lactose to displace affinity-bound asislotransferrin from the immobilized RCA120 lectin.

Asialoglycoproteins↗

Regulation of protein binding toward a ligand on chromatographic matrixes by masking and forced-releasing effects using thermoresponsive polymer.

A novel concept of affinity regulation based on masking and forced-releasing effects using a thermoresponsive polymer was elucidated. Affinity chromatographic matrixes were prepared using either poly(glycidyl methacrylate-co-ethyleneglycol dimethacrylate) or poly(glycidyl methacrylate-co-triethyleneglycol dimethacrylate) beads immobilized with ligand molecule, Cibacron Blue F3G-A (CB), together with poly(N-isopropylacrylamide) (PIPAAm), a polymer with a cloud point of 32 degrees C. Two different lengths of spacer molecules were used for the immobilization of CB while maintaining the PIPAAm size constant. Chromatographic analyses using bovine serum albumin as a model protein showed a clear correlation between spacer length and binding capacity at temperatures lower than the lower critical solution temperature (LCST) of PIPAAm. The binding capacity under the LCST was significantly reduced only when the calculated spacer length was shorter than the mean size of the extended PIPAAm. Furthermore, the adsorbed protein could be desorbed (released) from the matrix surface by lowering the temperature to below the LCST while maintaining other factors such as pH and ion strength. Selective recovery of human albumin from human sera was demonstrated using this newly developed thermoresponsive affinity column.

Chromatography, Affinity↗