RATIONALE AND OBJECTIVE: The aim of the study was to survey misfiled cases in a picture archiving and communication system environment at two hospitals and to demonstrate the potential usefulness of an automated patient recognition method for posteroanterior chest radiographs based on a template-matching technique designed to prevent filing errors. MATERIALS AND METHODS: We surveyed misfiled cases obtained from different modalities in one hospital for 25 months, and misfiled cases of chest radiographs in another hospital for 17 months. For investigating the usefulness of an automated patient recognition and identification method for chest radiographs, a prospective study has been completed in clinical settings at the latter hospital. RESULTS: The total numbers of misfiled cases for different modalities in one hospital and for chest radiographs in another hospital were 327 and 22, respectively. The misfiled cases in the two hospitals were mainly the result of human errors (eg, incorrect manual entries of patient information, incorrect usage of identification cards in which an identification card for the previous patient was used for the next patient's image acquisition). The prospective study indicated the usefulness of the computerized method for discovering misfiled cases with a high performance (ie, an 86.4% correct warning rate for different patients and 1.5% incorrect warning rate for the same patients). CONCLUSION: We confirmed the occurrence of misfiled cases in the two hospitals. The automated patient recognition and identification method for chest radiographs would be useful in preventing wrong images from being stored in the picture archiving and communication system environment.
To prefetch images in a hospital-wide picture archiving and communication system (PACS), a rule must be devised to permit accurate selection of examinations in which a patient's images are stored. We developed an inductive method to compose prefetch rules from practical data which were obtained in a hospital using a decision tree algorithm. Our methods were evaluated on data acquired in Osaka University Hospital for one month. The data collected consisted of 58,617 cases of consultation reservations, 643,797 examination histories of patients, and 323,993 records of image requests in PACS. Four parameters indicating whether the images of the patient were requested or not for each consultation reservation were derived from the database. As a result, the successful selection sensitivity for consultations in which images were requested was approximately 0.8, and the specificity for excluding consultations accurately where images were not requested was approximately 0.7.
First, history of PACS in Japan from 1982 to 2002 has been investigated. By 2002 total of 1468 PACS units have been installed. Of these, 1174 are small-size PACS with less than four image display terminals, 203 are medium-size with 5-14 terminals, and 91 are large-size with 15 up to 1300 terminals. The main nine large-size PACS of 91 have been retrospectively investigated from 1984 for PACS experiments and from 1989 for PACS operation. Most of these nine hospitals have increased the number of PACS terminals by installing additional PACS units, instead of reinforcing the existing single PACS. The use of DICOM interfaces has increased the number of modalities connected to PACS and influenced the spreading of PACS installations in Japan. The status of HIS and RIS coupling to PACS, and the use of PACS in primary diagnosis or in image referral are discussed. Assessment of PACS is now in an early stage. Baseline studies of HIS/RIS/PACS effectiveness have been carried out to assess quantitatively the PACS merit. Second, history of PACS development in Korea is described. Very acute climbing up of filmless PACS diffusion was observed from 2000 to 2002. The reasons seem to be lack of domestic X-ray film industry, economic crisis in 1997 and PACS Reimbursement Act in health insurance in Korea. Third, the Hong Kong Wide Area Image Distribution/PACS Project is reported. It is now under phase 1 of design and partial implementation employing the latest and the highest ends of advanced technology such as failure resilience.
Explore the source record for details and available documents.
The digital imaging and communications in medicine (DICOM) standard includes parts regarding nonimage data information, such as image study ordering data and performed procedure data, and is used for sharing information between HIS/RIS and modality systems, which is essential for IHE. To bring such parts of the DICOM standard into force in Japan, a joint committee of JIRA and JAHIS established the JJ1017 management guideline, specifying, for example, which items are legally required in Japan, while remaining optional in the DICOM standard. In Japan, the contents of orders from referring physicians for radiographic examinations include details of the examination. Such details are not used typically by referring physicians requesting radiographic examinations in the United States, because radiologists in the United States often determine the examination protocol. The DICOM standard has code tables for examination type, region, and direction for image examination orders. However, this investigation found that it does not include items that are detailed sufficiently for use in Japan, because of the above-mentioned reason. To overcome these drawbacks, we have generated the JJ1017 code for these 3 codes for use based on the JJ1017 guidelines. This report introduces the JJ1017 code. These codes (the study type codes in particular) must be expandable to keep up with technical advances in equipment. Expansion has 2 directions: width for covering more categories and depth for specifying the information in more detail (finer categories). The JJ1017 code takes these requirements into consideration and clearly distinguishes between the stem part as the common term and the expansion. The stem part of the JJ1017 code partially utilizes the DICOM codes to remain in line with the DICOM standard. This work is an example of how local requirements can be met by using the DICOM standard and extending it.
There are many cases in which picture archiving and communication systems (PACS) are built with old-type existing modalities with no DICOM output. One of the methods for interfacing them to the PACS is to implement video capture (/ frame grabber) equipment. This equipment takes analog video signal output from medical imaging modalities, and amplitude of the video signal is A/D converted and supplied to the PACS. In this report, we measured and evaluated the accuracy at which this video capture equipment could capture the image. From the physical evaluation, we found the pixel values of an original image and its captured image were almost equal in gray level from 20%-90%. The change in the pixel values of a captured image was +/-3 on average. The change of gray level concentration was acceptable and had an average standard deviation of around 0.63. As for resolution, the degradation was observed at the highest physical level. In a subjective evaluation, the evaluation value of the CT image had a grade of 2.81 on the average (the same quality for a reference image was set to a grade of 3.0). Abnormalities in heads, chests, and abdomens were judged not to influence diagnostic accuracy. Some small differences were seen when comparing captured and reference images, but they are recognized as having no influence on the diagnoses.