Assessment of bolus injection protocol with appropriate concentration for quantitative assessment of pulmonary perfusion by dynamic contrast-enhanced MR imaging.

PURPOSE: To determine the appropriate concentration for quantitative assessment of dynamic contrast-enhanced pulmonary MR imaging. MATERIALS AND METHODS: A total of 40 consecutive patients with small bronchioalveolar carcinoma underwent perfusion single-photon emission tomography (SPECT) and three-dimensional (3D) dynamic MR imaging with a 3D radiofrequency spoiled gradient-echo sequence. In each patient, 5 mL of contrast media with 0.1, 0.3, and 0.5 mmol/mL were administered at a rate of 5 mL/second. All patients were divided into two groups (<70 kg and > or =70 kg) for assessment of appropriate concentration to quantitatively assess regional perfusion parameter in routine clinical practice. Pulmonary blood flow (PBF) in each protocol was calculated from a signal intensity (SI)-time course curve. Differences and limits of agreement of PBF between dynamic MR imaging (PBF(MR)) using three different concentrations and perfusion SPECT (PBF(SPECT)) were statistically compared in both patient groups. RESULTS: PBF(MR) using 0.3 mmol/mL in the <70-kg group and 0.5 mmol/mL in the > or =70-kg group showed no significant difference compared with PBF(SPECT) (P > 0.05). Limits of agreements in 0.3 mmol/mL in the <70-kg group and 0.5 mmol/mL in the > or =70-kg group were smaller than those of the other concentrations and small enough for clinical purposes. CONCLUSION: Appropriate concentrations provide accurate and reproducible assessments of regional pulmonary perfusion parameters on 3D dynamic MR perfusion imaging. We suggest using 5 mL of contrast media with 0.3 mmol/mL for patients weighing less than 70 kg and 0.5 mmol/mL for patients weighing 70 kg or more.

Aged↗

Primary pulmonary hypertension: 3D dynamic perfusion MRI for quantitative analysis of regional pulmonary perfusion.

OBJECTIVE: The purpose of this study was to determine whether quantitative pulmonary perfusion parameters obtained from 3D dynamic contrast-enhanced MR perfusion data can be used to assess the severity of primary pulmonary hypertension (PPH) as indicated by pulmonary vascular resistance (PVR) and mean pulmonary artery pressure (MPAP). CONCLUSION: Three-dimensional dynamic contrast-enhanced MRI has potential for assessment of disease severity as indicated by PVR and MPAP in patients with PPH.

Adult↗

Anticoagulant-induced pseudothrombocytopenia occurring after transcatheter arterial embolization for hepatocellular carcinoma.

Pseudothrombocytopenia (PTCP) is the in vitro phenomenon of anticoagulant-activated platelet agglutination that results in spuriously low platelet counts. We report the case of a 65-year-old man with EDTA- and sodium citrate-dependent PTCP occurring after transcatheter arterial embolization (TAE) for hepatocellular carcinoma (HCC) due to hepatitis C cirrhosis. Invasion of the portal and hepatic veins by HCC formed severe trans-tumoral arterio-venous shunts that were effectively treated by TAE. Two days after the therapy, PTCP was seen on blood count and continued for 4 months. The patient received unnecessary treatment for disseminated intravascular coagulation (DIC) until the diagnosis of PTCP was established. PTCP is a rare complication but should be considered after TAE for HCC; lack of recognition may lead the physician to misdiagnosis and patient mismanagement.

Aged↗

Focal liver lesions: breathhold gradient- and spin-echo T2-weighted imaging for detection and characterization.

PURPOSE: To evaluate breathhold gradient- and spin-echo (GRASE) T2-weighted imaging for the detection and characterization of focal liver lesions. MATERIALS AND METHODS: Two GRASE sequences with different echo times (75 and 90 msec, GRASE75 and GRASE90) were compared with respiratory-triggered fast spin-echo (SE) and breathhold fast SE in 64 patients with 103 malignant and 51 benign lesions. Compared with respiratory-triggered and breathhold fast SE, GRASE reduced scan time by 77% to 82% and 21% to 27%, respectively. Two independent readers evaluated image quality and reviewed 504 liver segments on a segment-by-segment basis. Observer performance was evaluated with receiver operating characteristic (ROC) curve analysis. The signal-to-noise ratio (SNR) of liver and spleen, and lesion-to-liver contrast-to-noise ratio (CNR) were also measured. RESULTS: The overall quality of the GRASE images was higher than that of the respiratory-triggered and breathhold fast SE images, although signal inhomogeneities were more frequently observed with GRASE. No significant difference in the values of the area under the ROC curve (Az) for malignant lesion detection was found. The mean SNR and CNR were highest for respiratory-triggered fast SE. CONCLUSION: T2-weighted breathhold GRASE has the potential to provide faster liver imaging.

Adult↗

Gradient- and spin-echo T2-weighted imaging for SPIO-enhanced detection and characterization of focal liver lesions.

PURPOSE: To evaluate superparamagnetic iron oxide (SPIO)-enhanced breathhold T2-weighted GRASE imaging in detection and characterization of focal liver lesions. MATERIALS AND METHODS: In 30 patients (including 20 with cirrhosis) with 39 malignant and 25 benign lesions, gradient- and spin-echo (GRASE) images with two echo times (75 and 90 msec; GRASE75 and GRASE90) were obtained prior to and following administration of SPIO, and compared with respiratory-triggered and breathhold fast spin-echo (RT-FSE and BH-FSE) images. Two readers evaluated image quality and reviewed 240 liver segments for sensitivity and specificity. Signal-to-noise ratio (SNR), and its reduction in liver and spleen after administration of SPIO, and lesion-to-liver contrast-to-noise ratio (CNR) were measured. RESULTS: Compared with RT-FSE and BH-FSE, GRASE reduced scan time by 77% to 82% and 21% to 27%, respectively. The image qualities with BH-FSE and GRASE75 were higher than with BH-FSE and GRASE90. BH-FSE showed higher specificity than RT-FSE and GRASE90, but otherwise there were no significant differences between pulse sequences for sensitivity or specificity. The mean SNR and CNR of the lesions with RT-FSE were significantly higher than with the other methods. SPIO-induced signal reduction of liver SNR was smallest with BH-FSE. CONCLUSION: GRASE is faster and more sensitive to SPIO than FSE, but its sensitivity and specificity were slightly inferior to those of BH-FSE. Image quality is a current limitation.

Adult↗

ADC measurement of abdominal organs and lesions using parallel imaging technique.

OBJECTIVE: The purpose of our study was to assess the reliability and usefulness of parallel imaging for apparent diffusion coefficient (ADC) measurement of abdominal organs and lesions. MATERIALS AND METHODS: Single-shot spin-echo echo-planar diffusion-weighted MRI (TE = 66, b = 0, 600 s/mm2) was performed in phantom and clinical studies. The b value was set to minimize the effects of perfusion in tissue and to maintain signal-to-noise ratio. Bottle phantoms were scanned with and without parallel imaging and with various parallel imaging factors and at various positions to evaluate the effects of parallel imaging on ADCs. In 200 consecutive clinical patients (122 men and 78 women: mean age, 61.9 years), ADCs were calculated for liver (four segments), spleen, pancreas (head, body, tail), gallbladder, renal parenchyma, and back muscle, and then compared to evaluate the reliability of clinical ADC measurements with parallel imaging. ADCs were also calculated for diffuse diseases and focal lesions (94 malignant and 93 benign) of abdominal organs to evaluate the clinical usefulness of ADC. RESULTS: Location-dependent changes in water ADCs were minimal with parallel imaging factors first of 3, then of 4, and were small except for measurements at the image periphery. Acetone ADCs were saturated at 4.00 x 10(-3) mm2/s. Degraded image quality prevented ADC measurement of the left hepatic lobe and pancreas in 7-18 patients. There was no significant difference among ADCs of four liver segments (1.50 +/- 0.24 [SD] x 10(-3) mm2/s - 1.56 +/- 0.31 x 10(-3) mm2/s) and between ADCs of the right and left kidneys (2.65 +/- 0.30 x 10(-3) mm2/s, 2.59 +/- 0.33 x 10(-3) mm2/s). ADC of the pancreas tail (1.65 +/- 0.37 x 10(-3) mm2/s) was significantly lower than those of the head (1.81 +/- 0.40 x 10(-3) mm2/s) and body (1.81 +/- 0.41 x 10(-3) mm2/s) (p < 0.005). Renal ADCs were significantly lower in patients with renal failure (right: 2.15 +/- 0.30 x 10(-3) mm2/s; left: 2.11 +/- 0.25 x 10(-3) mm2/s) than in those without disease (right: 2.67 +/- 0.29 x 10(-3) mm2/s; left: 2.60 +/- 0.32 x 10(-3) mm2/s) (p < 0.005). ADC of pancreatic cancer was significantly higher than that of healthy pancreas (p < 0.05). ADC of renal angiomyolipoma was significantly lower than those of renal cell carcinoma and healthy renal parenchyma (p < 0.0005). CONCLUSION: Clinical ADC measurements of abdominal organs and lesions using parallel imaging appear to be reliable and useful, and the effect of parallel imaging on calculated values is considered to be minimal.

Adult↗

Gadolinium-enhanced phase-contrast magnetic resonance portography.

PURPOSE: The purpose of this study was to investigate the effect and usefulness of gadolinium-chelated contrast medium in phase-contrast magnetic resonance (MR) portography. METHODS: Twenty-six patients (21 men, 5 women; aged 34 to 79 years, mean 62 years) underwent respiratory-triggered 3-dimensional phase-contrast portography before and after administration of gadolinium in a 1.5T MR unit. Coronal maximum intensity projection (MIP) images of the portal vein were reconstructed and compared to conventional arterial portograms regarding visualization. Signal-to-noise ratio (SNR) and portal vein-to-liver contrast-to-noise ratios (CNR) of main, right, right anterior, right posterior, left portal veins, and umbilical portion were measured on both non-enhanced and gadolinium-enhanced images and compared. RESULTS: Portal veins and branches were more clearly visualized on the gadolinium-enhanced than on the non-enhanced images. Compared to arterial portography, gadolinium-enhanced portography showed similar performances in visualization, except in the right posterior branch and left portal vein. No severe image degradation from respiration was experienced. SNR was significantly higher on the gadolinium-enhanced than on non-enhanced images except in the right anterior branch. CNR was significantly higher on the gadolinium-enhanced than on the non-enhanced images at all measured locations. CONCLUSIONS: Administration of gadolinium improves the SNR and CNR of phase-contrast portography and visualization of the portal vein. The phase-contrast technique with gadolinium enhancement can be used to evaluate the portal vein as a supplemental technique.

Adult↗

Oxygen-enhanced MR imaging: correlation with postsurgical lung function in patients with lung cancer.

PURPOSE: To prospectively determine if lung function as assessed with oxygen-enhanced magnetic resonance (MR) imaging correlates with postsurgical lung function in patients with lung cancer, as compared with quantitative and qualitative findings of computed tomography (CT) and scintigraphy. MATERIALS AND METHODS: Study received institutional review board approval, and informed patient consent was obtained. Thirty consecutive patients (16 men and 14 women, aged 44-81 years; mean age, 65 years) considered candidates for lung resection underwent oxygen-enhanced MR imaging, CT, perfusion scintigraphy, and measurement of forced expiratory volume in 1 second (FEV1). A respiratory-synchronized inversion-recovery half-Fourier single-shot turbo spin-echo MR sequence was used for data acquisition. Correlation of postsurgical lung function (postsurgical FEV1) as determined with oxygen-enhanced MR imaging (FEV1MR), quantitative assessment with CT (FEV1Quant), qualitative assessment with CT (FEV1Qual), and perfusion scintigraphy (FEV1PS) was conducted with actual postsurgical FEV1, and the limits of agreement of each were determined with Bland-Altman analysis. RESULTS: Correlation between postsurgical FEV1MR and actual postsurgical FEV1 values was excellent (r2= 0.81, P < .001); it was better than that of FEV1Qual (r2= 0.76) and FEV1PS (r2= 0.77) and similar to that of FEV1Quant (r2= 0.81) values. The limits of agreement of FEV1MR were between -9.9% and 10.9%. CONCLUSION: Oxygen-enhanced MR imaging can be used to predict posturgical lung function in patients with lung cancer, similar to quantitative CT.

Adult↗

Prognostic value of dynamic MR imaging for non-small-cell lung cancer patients after chemoradiotherapy.

PURPOSE: To determine the prognostic value of dynamic MRI for non-small-cell lung cancer (NSCLC) patients after chemoradiotherapy. MATERIALS AND METHODS: A total of 114 consecutive patients with NSCLC underwent dynamic MRI after chemoradiotherapy. The patients were divided into two groups (local control (n=22) and local failure (n=92)) according to the presence of local recurrence. From the signal intensity-time course curve in each subject, the maximum relative enhancement ratio and slope of enhancement were calculated, and compared between two groups by Student's t-test. To determine the feasible threshold values of both MR indexes for group differentiation, ROC-based positive tests were performed. Finally, the Kaplan-Meier survival curves of each group divided by the adapted threshold value were compared by log-rank test. RESULTS: The maximum relative enhancement ratio and the slope of enhancement in the local control group were significantly lower than those in the local failure group (P<0.05). Using 0.08/sec as the threshold value of the slope of enhancement, the sensitivity and specificity for differentiation between the two groups were 90.9% and 91.3%, respectively. When the slope of enhancement was adopted for estimation of prognosis after therapy, the mean survival period of the slope of enhancement 0.08/sec (P<0.0001). CONCLUSION: Dynamic MRI has potential prognostic value for NSCLC patients after chemoradiotherapy.

Adult↗

Thin-section multiplanar reformats from multidetector-row CT data: utility for assessment of regional tumor extent in non-small cell lung cancer.

PURPOSE: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. MATERIALS AND METHODS: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. RESULTS: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p<0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p=0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p=0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p=0.04). CONCLUSION: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non-small cell lung cancer patients.

Adult↗

Estimation of contrast of refraction contrast imaging compared with absorption imaging-basic approach.

PURPOSE: We discuss the usefulness of the refraction contrast method using highly parallel X-rays as a new approach to minute lung cancer detection. The advantages of refraction contrast images are discussed in terms of contrast, and a comparison is made with absorption images. MATERIALS AND METHODS: We simulated refraction contrast imaging using globules with the density of water in air as models for minute lung cancer detection. The contrast intensified by bright and dark lines was compared on a globule with the contrast of absorption images. We adopted the Monte Carlo simulation to determine the strength of the profile curve of the photon counts at the detector. RESULTS: The obtained contrasts were more intense by two to three digits than those obtainable with the absorption contrast imaging method. CONCLUSION: The contrast in refraction contrast imaging was more intense than that obtainable with absorption contrast imaging. A two to three digit improvement in contrast means that it is possible to greatly reduce the exposure dose necessary for imaging. Therefore, it is expected to become possible to detect the interfaces of soft tissues, which are difficult to capture with conventional absorption imaging, at low dosages and high resolution.

Absorption↗

Single-shot half-Fourier RARE sequence with ultra-short inter-echo spacing for lung imaging.

PURPOSE: To improve the image quality of pulmonary magnetic resonance (MR) imaging using an ultra-short inter-echo spacing half-Fourier single shot rapid acquisition with relaxation enhancement (USHA-RARE) sequence. MATERIALS AND METHODS: Pulmonary MR images were acquired by USHA-RARE sequence with various inter-echo spacings. The sequence parameters were as follows: repetition time (TR)/effective TE: infinite/39-41 msec; section thickness: 10 mm; acquisition matrix: 128 x 128; field of view: 450 x 450 mm. Inter-echo spacing varied (2.5 msec, 3.0 msec, 3.5 msec, 4.0 msec, 4.5 msec, 5.0 msec), and the respective phase-encoding steps were 80, 77, 75, 74, 73, and 72. Signal-to-noise ratios (SNRs), the signal ratios between lung and fat (lung-to-fat ratio: LFRs), and the signal ratios between the lung and the serratus anterior muscle (lung-to-muscle ratio: LMRs) of each inter-echo spacing were calculated, and statistically evaluated. RESULTS: The SNRs at inter-echo spacings of < or = 3.0 msec were significantly higher than those > or = 4.0 msec (P < 0.05). The LFRs and LMRs at inter-echo spacing < or = 3.0 msec were significantly higher than those > or = 4.0 msec (P < 0.05). CONCLUSION: USHA-RARE sequence does improve signal intensity from the lung.

Adult↗

Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: Preliminary experience in 40 subjects.

PURPOSE: To assess regional differences in quantitative pulmonary perfusion parameters, i.e., pulmonary blood flow (PBF), mean transit time (MTT), and pulmonary blood volume (PBV) in the entire lung on a pixel-by-pixel basis in normal volunteers and pulmonary hypertension patients. MATERIALS AND METHODS: Three-dimensional ultrafast dynamic contrast-enhanced MR imaging was performed in 15 normal volunteers and 25 patients with pulmonary hypertension. From the signal intensity-time course curves, PBF, MTT and PBV maps were generated using deconvolution analysis, indicator dilution theories, and the central volume principle, on a pixel-by-pixel basis. From pulmonary perfusion parameter maps of normal volunteers and pulmonary hypertension patients, regional PBF, MTT, and PBV were statistically evaluated. RESULTS: Regional PBF, MTT, and PBV showed significant differences in the gravitational and isogravitational directions (P < 0.05). The quantitative pulmonary perfusion parameter maps demonstrated significant differences between normal volunteers and pulmonary hypertension patients (P < 0.05). CONCLUSION: Three-dimensional ultrafast dynamic contrast-enhanced MR imaging is feasible for the assessment of regional quantitative pulmonary perfusion parameters in the entire lung on a pixel-by-pixel basis in normal volunteers and pulmonary hypertension patients.

Adult↗

Dynamic MR imaging: value of differentiating subtypes of peripheral small adenocarcinoma of the lung.

PURPOSE: To determine the utility of dynamic magnetic resonance imaging (MRI) in the differential subtyping of small adenocarcinomas of the lung. MATERIALS AND METHODS: Twenty-nine pathologically diagnosed peripheral adenocarcinomas (less than 20 mm in diameter) underwent dynamic contrast-enhanced MRI. Maximum relative enhancement ratio, slope of enhancement, and corrected start time of enhancement were calculated from signal intensity-time curve of pulmonary lesion for each subject, and were statistically compared among bronchioloalveolar carcinoma (BAC) group (7 cases), mixed BAC group (10 cases), and adenocarcinoma group (12 cases). RESULTS: Maximum relative enhancement ratio (P<0.001) and slope of enhancement (P<0.001) of BAC group were significantly higher than those of mixed BAC and adenocarcinoma groups. Start times of BAC group were significantly earlier than those of mixed BAC (P=0.0001) and adenocarcinoma groups (P<0.0001). Adapting the thresholds values of MR indexes from the positive tests, sensitivity, specificity, positive predictive value, negative predictive value and accuracy for differentiating BAC from other subtypes were 85.7, 100.0, 100.0, 95.7, and 96.6%, respectively. CONCLUSIONS: Dynamic MRI is useful for differentiating subtypes of small peripheral adenocarcinoma.

Adenocarcinoma↗

Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo sequence: improvement of the image quality of oxygen-enhanced MRI.

PURPOSE: The purpose of the study presented here was to determine the improvement in image quality of oxygen-enhanced magnetic resonance (MR) subtraction imaging obtained with a centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence compared with that obtained with a conventional sequentially reordered inversion recovery single-shot HASTE (s-IR-HASTE) sequence for pulmonary imaging. MATERIALS AND METHODS: Oxygen-enhanced MR imaging using a 1.5 T whole body scanner was performed on 12 healthy, non-smoking volunteers. Oxygen-enhanced MR images were obtained with the coronal two-dimensional (2D) c-IR-HASTE sequence and 2D s-IR-HASTE sequence combined with respiratory triggering. For a 256x256 matrix, 132 phase-encoding steps were acquired including four steps for phase correction. Inter-echo spacing for each sequence was 4.0 ms. The effective echo time (TE) for c-IR-HASTE was 4.0 ms, and 16 ms for s-IR-HASTE. The inversion time (TI) was 900 ms. To determine the improvement in oxygen-enhanced MR subtraction imaging by c-IR-HASTE, CNRs of subtraction image, overall image quality, and image degradation of the c-IR-HASTE and s-IR-HASTE techniques were statistically compared. RESULTS: CNR, overall image quality, and image degradation of c-IR-HASTE images showed significant improvement compared to those s-IR-HASTE images (P<0.05). CONCLUSION: Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence enhanced the signal from the lung and improved the image quality of oxygen-enhanced MR subtraction imaging.

Adult↗

Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules.

OBJECTIVE: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. MATERIALS AND METHODS: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. RESULTS: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P < 0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P < 0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P < 0.05). CONCLUSION: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time.

Adolescent↗

Metastases in mediastinal and hilar lymph nodes in patients with non-small cell lung cancer: quantitative and qualitative assessment with STIR turbo spin-echo MR imaging.

PURPOSE: To evaluate short inversion time inversion-recovery (STIR) turbo spin-echo (TSE) magnetic resonance (MR) imaging for detection of metastases in lymph nodes by using quantitative and qualitative analyses. MATERIALS AND METHODS: One hundred ten patients (68 men and 42 women) with non-small cell lung cancer who ranged in age from 36 to 82 years (mean age, 64 years) were examined with respiratory-triggered STIR TSE MR imaging. Ratios of signal intensity in a lymph node to that in a 0.9% saline phantom (lymph node-saline ratios [LSRs]) for all lymph nodes were classified into three groups according to nodal short-axis diameter. LSRs of each group were compared by using pathologic diagnosis as the standard of reference. For quantitative analysis, the LSR threshold value for a positive test was determined on a per-node basis and tested for ability to enable a correct diagnosis on a per-patient basis. For qualitative analysis, signal intensities of lymph nodes were assessed by using a five-point visual scoring system. Results of quantitative and qualitative analyses were compared on a per-patient basis with McNemar testing. RESULTS: In 110 patients, 92 of 802 lymph nodes were pathologically diagnosed as containing metastases, while 710 lymph nodes did not contain metastases. Mean LSR in the lymph node group with metastasis was higher than that in the group without metastasis (P <.05). When an LSR of 0.6 was used as the positive-test threshold at quantitative analysis, sensitivity was 93% (37 of 40 patients) and specificity was 87% (61 of 70 patients) on a per-patient basis. With a score of 4 as the positive-test threshold at qualitative analysis, sensitivity was 88% (35 of 40 patients) and specificity was 86% (60 of 70 patients) on a per-patient basis. There was no significant difference (P >.05) between results of quantitative and those of qualitative analysis. CONCLUSION: Quantitative and qualitative analyses of STIR TSE MR images enable differentiation of lymph nodes with metastasis from those without. Qualitative analysis can substitute for quantitative analysis of STIR TSE MR imaging data.

Adult↗

Dynamic perfusion MRI versus perfusion scintigraphy: prediction of postoperative lung function in patients with lung cancer.

OBJECTIVE: The purpose of this study was to determine the capability of dynamic perfusion MRI as an alternative to pulmonary perfusion scintigraphy for prediction of postoperative lung function in patients with lung cancer. SUBJECTS AND METHODS. Sixty patients with lung cancer (35 men, 25 women) underwent dynamic perfusion MRI, perfusion scintigraphy, and preoperative and postoperative pulmonary function tests (forced expiratory volume in 1 sec [FEV(1)]). Perfusion MRIs were obtained with a 3D turbo field-echo sequence (TR/TE, 2.7/0.6; flip angle, 40 degrees; matrix, 128 x 96) using a 1.5-T scanner. Regional blood flow was calculated from the signal intensity-time curves after bolus injection of contrast medium on MRI (Q(MRI)) and uptake ratios of radioisotope on perfusion scintigraphy (Q(PS)). Postoperative lung functions predicted by MRI (FEV(1,MRI)) and perfusion scintigraphy (FEV(1,PS)) were calculated from preoperative FEV(1) and regional Qs. To determine the capability of MRI as an alternative to scintigraphy, we evaluated correlations and the limits of agreement between predicted FEV(1,MRI) and postoperative FEV(1) and between predicted FEV(1,PS) and postoperative FEV(1). RESULTS: The correlation coefficient of postoperative FEV(1) with FEV(1,MRI) (r = 0.93, p < 0.0001) was better than that with FEV(1,PS) (r = 0.89, p < 0.0001). The limits of agreement between postoperative FEV(1) and predicted FEV(1,MRI) (0.9% +/- 10.4%) were smaller than those between postoperative FEV(1) and predicted FEV(1,PS) (2.1% +/- 13.2%). CONCLUSION: Dynamic perfusion MRI is a feasible alternative to pulmonary perfusion scintigraphy for predicting postoperative lung function in patients with lung cancer.

Adult↗