Search PubMed⌕ Search

Biomedical subjects

Yonghong He

Publications and source records attributed to Yonghong He.

17 recordsLinked to original sources

Artificial intelligence-assisted histopathological diagnosis of endocervical gastric-type adenocarcinoma: a multicenter model development and validation study.

Endocervical gastric-type adenocarcinoma (GAS) is one of the most aggressive subtypes of cervical cancer and is frequently underdiagnosed due to morphological ambiguity, leading to delayed diagnosis. Despite the availability of molecular and genomic assays, their high cost, complexity, and limited reproducibility restrict clinical use. This study therefore proposes a highly sensitive artificial intelligence (AI)-assisted diagnostic system for GAS based exclusively on H&E-stained histopathological images. We included 309 slides from 96 GAS cases collected at Peking University Third Hospital from January 2018 to January 2025, representing the largest GAS cohort reported to date for AI research. In addition, we incorporated other morphologically analogous diseases, encompassing a total of 1,320 slides sourced from four categories: normal cervical mucosa (NORM), benign endocervical lesion entities (BELE), HPV-associated adenocarcinoma (HPVA), and endometrioid carcinoma with mucinous differentiation (ECMD). We developed GASPath, based on a novel multiple instance learning framework that efficiently captures fine-grained morphological variations from H&E-stained images. Beyond internal validation, GASPath was evaluated across 12 independent retrospective cohorts and further subjected to large-scale real-world validation on more than 7,000 samples from March 2024 to April 2025. Across three stages, GASPath demonstrated high performance. In internal validation (Stage I), it achieved an accuracy of 0.980 (95% CI 0.977-0.983) and an ROC-AUC of 0.995 (95% CI 0.994-0.997). In external validation (Stage II), the sensitivity reached 0.902 and improved to 0.968 with proposed strategies. For biopsy samples, GASPath achieved an ROC-AUC of 0.990 (95% CI 0.984-0.997). In large-scale real-world deployment (Stage III, n = 7,056), GASPath achieved a balanced accuracy of 0.953, with 100% sensitivity for GAS (45/45 cases correctly identified). The heatmaps highlight morphological features of GAS that are easily underestimated, such as irregular, angulated glands, subtle loss of nuclear polarity, and mild cytologic atypia, which show substantial morphological overlap with other diagnostic categories. GASPath enables high-sensitivity detection of GAS in routine H&E-stained slides, obviating the need for extensive auxiliary testing while preventing underdiagnosis and misdiagnosis. This advancement addresses a critical gap by streamlining diagnostic workflows without compromising accuracy. Its implementation could enable cost-effective, scalable AI-assisted diagnostics, potentially transforming the early detection and management of this aggressive cancer subtype.

Female↗

Bacillus subtilis assisted assembly of gold nanoparticles into long conductive nodous ribbons.

Gold nanopraticles with diameters of about 20 nm were assembled onto the surfaces of Bacillus subtilis by keeping the mixture of the nanoparicles and the bacteria in the dark without disturbance for over a month. During the aging process, the bacteria connected to each other end-to-end to form long wires and gold nanoparticles were coated compactly onto the surfaces of the wires simultaneously. The resulting composite wires were collapsed into ribbons with a width of about 1 microm after drying in air. The ribbons present a novel structure with nodes on their backbones and have lengths of several millimeters. They are conductive and showed Ohmic behavior, which provides potential applications in the fabrication of electronic nanodevices.

Bacillus subtilis↗

Polarization-degree imaging contrast in turbid media: a quantitative study.

Scattering in biological tissue can degrade imaging contrast and reduce the probe depth. Polarization-based measurement has shown its advantages in overcoming such drawbacks. Here, linear and circular polarization degree imaging is applied to a comblike metal target submerged in Intralipid solutions. Contrasts of the metal bars are measured quantitatively as functions of the Intralipid concentration and the submersion depths. Different behaviors in contrast for linear and circular polarizations are compared. Contributions to the background of circular polarization degree images by backscattering, snake, and diffusive photons are examined carefully.

Algorithms↗

Surface plasmon resonance sensor based on polarization interferometry and angle modulation.

A surface plasmon resonance (SPR) sensing technique based on polarization interferometry and angle modulation is presented. Its sensitivity is not a direct function of variation of reflection intensity, nor of phase shift. Rather, it is a function of the complex reflection coefficient. A three times standard deviation detection limit of 5.1 x 10(-7) refractive index units in a 2 Hz bandwidth is obtained with our experimental setup. A theoretical analysis shows that this technique can provide a wide linear measurement range. Moreover, the sensitivity is insensitive to the thickness of gold films over approximately 5 nm. This SPR sensing technique is suitable for physical, chemical, and biological research.

Computer-Aided Design↗

Improvement of low-level light imaging performance using optical clearing method.

Low-level light-emitting imaging technique often detects the light emerged at the tissue surface that is generated internally from a specific target. However, in most cases, the high scattering nature of biological tissue limits the sensitivity and spatial resolution of this imaging modality. In this paper, we report that a significant improvement of chemiluminescence (CL) imaging performance in terms of both sensitivity and spatial resolution can be achieved by use of the topical application of glycerol solution onto tissue sample, i.e. optical clearing approach. Monte Carlo (MC) simulation of internally-launched point source shows that the decrease of scattering coefficient of turbid medium, which can be achieved by optical tissue clearing approach, causes stronger peak intensity with a narrower full-width at half-maximum (FWHM). The improvement becomes more significant with the source depth increasing from 1 to 5 mm. The experimental results shows that tissue clearing with 50% glycerol solution could largely improve the brightness and the spatial resolution of CL imaging when the target is covered by biological tissue with a thickness of either 1 or 3mm. This method could have potential applications for the in vivo low-level light imaging techniques.

Algorithms↗

Use of optical coherence tomography in delineating airways microstructure: comparison of OCT images to histopathological sections.

An ideal diagnostic system for the human airways should be able to detect and define early development of premalignant pathological lesions, to facilitate optimal curative treatment and prevent irreversible and/or invasive lung disease. There is great need for exploration of safe, repeatable imaging techniques which can run at real-time and with high spatial resolution. In this study, optical coherence tomography (OCT) was utilized to acquire cross-sectional images of upper and lower airways using fresh pig lung resections as a model system. Obtained OCT images were compared with parallel tissue characterization by conventional histological analysis. Our objective was to determine whether OCT differentiates the composite structural layers and inherent anatomical variations along different airway locations. The data show that OCT can clearly display the multilayered structure of the airways. The subtle architectural differences in three separate anatomical locations including trachea, main bronchus and tertiary bronchus were clearly delineated. Images of the appropriate anatomical profiles, with depth of up to 2 mm and 10 microm spatial resolution were obtained by our current OCT system, which was sufficient for recognition of the epithelium, subepithelial tissues and cartilage. In addition, the relative thickness of individual structural components was accurately reflected and comparable to histological sections. These data support OCT as a highly feasible, optical biopsy tool, which merits further exploration for early diagnosis of human airway epithelial pathology.

Animals↗

Doppler optical coherence imaging of converging flow.

The experimental methods of Doppler optical coherence tomography are applied for two-dimensional flow mapping of highly scattering fluid in flow with complex geometry. Converging flow (die entry) is used to demonstrate non-invasive methods to map varying velocity profiles before and after the entry. Complex geometry flow is scanned with approximately 10 x 10 x 10 microm3 spatial resolution. Structural images of the phantom and specific velocity images are demonstrated. A variety of velocity profiles have been obtained before and after the entry. Concave, blunted, parabolic and triangular profiles are obtained at different distances after the entry. Application of the technique to the study of blood circulation is discussed.

Blood Flow Velocity↗

[Advance of pesticide residue analysis techniques based on biological principle].

The application of pesticide residue analysis techniques based on biological principle, such as immunoassay, biosensor and direct test the influence of pesticide upon the activity of the enzyme and the growth of the propagation, was reviewed in this paper. Immunoassay is a kind of precise and sensitive method, but it's not easy to produce the antibody of pesticide. The strongpoint of biosensor is the process of the detection is quickly and real time, but the sensitivity and stability of biosensor still need improve. The tests based on the activity of the enzyme and the growth of the propagation are simple and inexpensive, and are useful in the situation of acute-poisoning and severe contamination. These techniques general work fast, cost inexpensive, and do not need large-volume unit, so they have a good large potential in extensive pesticide residue monitoring and spot assays.

Biosensing Techniques↗

Enhanced sensitivity and spatial resolution for in vivo imaging with low-level light-emitting probes by use of biocompatible chemical agents.

We describe a technique that uses biocompatible chemical agents to enhance both the sensitivity and the resolution of in vivo imaging with low-level light-emitting probes. We demonstrate experimentally, with chemiluminescence (CL) imaging in vitro as an example, that the detected intensity of CL from treated 3-mm-thick skin tissue is approximately fivefold stronger than that from untreated skin. The spatial resolution correspondingly increases approximately threefold.

Animals↗

Determination of flow velocity vector based on Doppler shift and spectrum broadening with optical coherence tomography.

We describe a technique that uses Doppler optical coherence tomography to estimate accurately the scattering fluid-flow velocity without a priori knowledge of the Doppler angle. Our technique is based on the combined use of the Doppler shift on the interference signal and the Doppler spectrum broadening caused by the particles moving across the probe beam. It is shown that the estimated values of the Doppler angle and average fluid velocity from the experiments agree well with the preset values.

Models, Theoretical↗

Localization of tumor by chemiluminescence probe during photosensitization action.

As a chemiluminescence (CL) probe, 3,7-dihydro-6-[4-[2-(N'-(5-fluoresceinyl) thioureido)ethoxy]phenyl]-2-methylimidazo[1,2-a]pyrazin-3-one dosium salt (FCLA) can sensitively and specifically react with singlet oxygen ((1)O(2)) and superoxide (O(2)(-)). Based on the fact that photosensitization action involves (1)O(2) generation, this report presents a novel method for localization of tumor mediated by FCLA. In experiments, FCLA was used as an optical reporter of (1)O(2) produced from photosensitization reaction of hematoporphyrin derivative. The effects of azide inhibition and deuterium enhancement on photosensitized CL indicated that (1)O(2) molecules generated during photosensitization action could be measured and imaged. In vivo experiments in vivo with tumor-bearing nude mice showed a clear CL image of tumor. The study suggests that CL imaging method may be applicable to the detection of (1)O(2) and the diagnosis of superficial tumors.

Animals↗

FCLA chemiluminescence from sonodynamic action in vitro and in vivo.

In this work, the chemiluminescence method was engaged for the first time to detect the active oxygen species during sonodynamic action in vitro and in vivo. We used FCLA (3,7-dihydro-6-[4-[2-[N'-(5-fluoresceinyl)thioureido]-ethoxy]phenyl]-2-methylimidazo[1,2-a]pyrazin-3-one sodium salt), which can selectively react with singlet oxygen ((1)O(2)) or superoxide anion (O(2)(-)) to emit photons, to detect in real time oxygen free radical formation in the sonosensitization of hematoporphyrin derivative. The results show that (1)O(2) is involved in the sonosensitization. In in vivo experiments, a tumor-imaging method by sonodynamic chemiluminescence detection was established. This method could have potential applications in clinics for tumor diagnosis.

Fluoresceins↗

Experimental study on photodynamic diagnosis of cancer mediated by chemiluminescence probe.

A novel method of photodynamic diagnosis of cancer mediated by chemiluminescence probe is presented. The mechanism for photodynamic therapy involves singlet oxygen ((1)O(2)) generated by energy transfer from photosensitizers. (1)O(2) can react with 3,7-dihydro-6-[4-[2-(N'-(5-fluoresceinyl)thioureido)ethoxy]phenyl]-2-methylimidazo[1,2-a]pyrazin-3-one sodium salt (FCLA), which is a Cypridina luciferin analog and a specific chemiluminescence probe for detecting (1)O(2) and superoxide (O(2)(-)). The reaction of FCLA and (1)O(2) can give emission with peak wavelength at about 532 nm. In the present study, FCLA was chosen as an optical reporter of (1)O(2) produced from the photosensitization reaction of hematoporphyrin derivative in model solution and in nude mice with transplanted mammary cancer. Photosensitized chemiluminescence from the reaction of FCLA with (1)O(2) was detected by a highly sensitive Intensified Charge-Coupled Device detector. The chemiluminescence was markedly inhibited by the addition of 10 mmol/l sodium azide (NaN(3)) to the model solution and minor effects were observed at the addition of 10 micromol/l superoxide dismutase, 20 mmol/l mannitol and 100 microg/ml catalase, respectively, thus indicating that (1)O(2) generation from photosensitization reaction mainly results in light emission. Experiments in vivo with tumor-bearing mice showed a clear chemiluminescence image of tumor. The study suggests that this novel method may be applicable to the diagnosis of superficial tumors.

Animals↗

In vivo sonoluminescence imaging with the assistance of FCLA.

In this paper, sonoluminescence of tissues is reported for the first time. A sonoluminescence image of a living animal was obtained with a high-sensitivity imaging system. Furthermore, to enhance biological sonoluminescence, fluoresceinyl Cypridina luminescent analogue (FCLA), a chemiluminescence analysis agent, was used in the experiment. With the assistance of FCLA we succeeded in observing an image of a living animal with high contrast and good signal-to-noise ratio. This technique has potential applications in clinical diagnosis.

Acoustics↗

Rapid determination of rice seed vigour by spontaneous chemiluminescence and singlet oxygen generation during early imbibition.

Using a highly sensitive single photon counter, a spontaneous chemiluminescence (CL) study on rice (Oryza sativa L.) seeds stored in different years was carried out. We first observed that the degree of ageing in rice seeds was related to the intensity of spontaneous CL during early imbibition (0-30 min). Rice seeds stored for a shorter time had a stronger intensity of CL in early imbibition. The germination rate of rice seeds showed an obvious positive correlation with the intensity of spontaneous CL. Singlet oxygen ((1)O(2)) in rice seeds during early imbibition was investigated by a CL method using a cypridina luciferin analogue, 2-methyl-6-(p-methoxyphenyl)-3,7-dihydroimidazo [1,2alpha] pyrazin-3-one (MCLA), as a selective CL probe. Additional experimental evidence for the formation of (1)O(2) came from the quenching effect of sodium azide (NaN(3)) on MCLA-mediated rice seeds' CL. Analysis based on the experimental results demonstrated that spontaneous CL in rice seeds during early imbibition was mainly contributed by singlet oxygen ((1)O(2)).

Germination↗

Imaging of ultra-weak bio-chemiluminescence and singlet oxygen generation in germinating soybean in response to wounding.

Ultra-weak bio-chemiluminescence (UBC) from germinating soybean (Glycine max L. Merr) cotyledon under mechanical wounding was observed using a high-sensitivity imaging system based on an ICCD detector and a highly sensitive single photon counter (SPC) device. The UBC imaging showed that the intensity at the injury location on a wounded cotyledon was obviously enhanced as compared with that at the non-injured point. The UBC intensity of wounded cotyledons was initially very high and reached a stationary state after about 5 min. Wounding-induced emission could be suppressed by wounding in the presence of sodium azide. Deuterium oxide amplified the emission intensity. It was concluded that singlet oxygen ((1)O(2)) was the main cause of the emission during the wounding phase.

Cotyledon↗

Dynamic optical clearing effect of tissue impregnated with hyperosmotic agents and studied with optical coherence tomography.

The depth of light penetration into highly scattering tissues can be improved by the application of biocompatible and osmotically active chemical agents. We compare the dynamics of optical clearing of tissue by the topical application of glycerol and dimethyl sulfoxide (DMSO) using optical coherence tomography (OCT). It is demonstrated experimentally that both agents can largely improve the OCT imaging depth for porcine stomach tissue. During a period of approximately 20 to 30 min after the application of glycerol image contrast is also enhanced. This enhancement disappears over time. Such enhancement of image contrast is not observed with DMSO. Glycerol causes a higher degree of dehydration of the tissue than DMSO does. We suggest that these phenomena are caused by a two-stage diffusion of the chemicals. The first stage of diffusion is from the top tissue to the intercellular space, and the second is into the cell matrix. During the first stage, the imaging contrast could be improved by dehydration.

Animals↗