Search PubMed⌕ Search

Biomedical subjects

Yongchao Zhang

Publications and source records attributed to Yongchao Zhang.

8 recordsLinked to original sources

Reduction of the nonspecific binding of a target antibody and of its enzyme-labeled detection probe enabling electrochemical immunoassay of an antibody through the 7 pg/ml-100 ng/mL (40 fM-400 pM) range.

We describe a simple, potentially low-cost, amperometric, enzyme-amplified, sandwich-type immunoassay, monitoring IgG at a concentration as low as approximately 7 pg/mL with a dynamic range of 10(4). The assay utilizes a screen-printed carbon electrode on which a redox hydrogel and avidin are co-electrodeposited. To neutralize nonspecifically binding positively charged microdomains of the avidin, two polyanions, poly(acrylic acid-co-maleic acid) and poly(acrylic acid), are applied. These polyanions bind to the film not only electrostatically but also by Michael addition reaction to cysteine, lysine, or arginine functions of the avidin. The electrode is then made specific for the analyte, for which rabbit IgG was chosen, by conjugating the film-bound avidin to biotin-labeled anti-rabbit IgG. After exposure to the tested solution and capture of rabbit IgG, the sandwich is completed by conjugation of horseradish-peroxidase (HRP)-labeled anti-rabbit IgG. Electrical contact between the HRP and the electrode-bound hydrogel results in the formation of an electrocatalyst for the electroreduction of H2O2 to water. The application of the poly(acrylic acid-co-maleic acid) and the poly(acrylic acid) reduces the nonspecific adsorption-associated noise, lowers the detection limit from 3 ng/mL (approximately 20 pM analyte antibody concentration) to approximately 7 pg/mL (approximately 40 fM analyte antibody concentration), and also expands the dynamic range to 10(4).

Adsorption↗

Detection of approximately 10(3) copies of DNA by an electrochemical enzyme-amplified sandwich assay with ambient O(2) as the substrate.

The electrochemical sandwich-type, enzyme-amplified assay of Zhang, Kim, and Heller (Anal. Chem. 2003, 75, 3267-3269) was simplified by replacing the amplifying horseradish peroxidase with bilirubin oxidase (BOD). BOD catalyzes the reduction of ambient O(2) to water and obviates the need for adding H(2)O(2). Femtomolar (10(-)(15) M) concentrations of DNA were detected at a 10-microm-diameter tip of a carbon fiber electrode. Correspondingly, a few thousand copies of DNA were detected in approximately 5-microL samples. The sandwich is formed in an electron-conducting redox hydrogel, to the polymer of which a DNA capture sequence is bound. Capture of the analyte DNA and its hybridization with a BOD-labeled complementary DNA sequence, electrically connects the BOD label to the electron-conducting redox polymer, which is in electrical contact with the electrode. Placing the BOD in contact with the redox polymer thus converts the noncatalytic base layer into a catalyst for the electroreduction of O(2) to water at +0.12 V (vs Ag/AgCl) (Figure 1). In an exemplary assay, approximately 3000 copies of the iron transporting sequence of the sit gene of Shigella flexneri were detected without PCR amplification.

Animals↗

Bilirubin oxidase label for an enzyme-linked affinity assay with O2 as substrate in a neutral pH NACL solution.

Laccase, a copper enzyme catalyzing the four-electron reduction of O(2) to water, has been shown by others to be a useful label in enzyme-linked immunoassays, in which the substrate is ambient O(2) instead of an added chemical, such as hydrogen peroxide, or a phosphate ester of a phenol. Laccase-catalyzed O(2) reduction is, however, inhibited by halides, which complex the enzyme's copper ions. Replacement of laccase by bilirubin oxidase, a copper enzyme retaining its maximal activity at high chloride concentrations and at pH 7.2, allows enzyme-amplified affinity assays with O(2) as the substrate in neutral-pH chloride solutions, exemplified here by the assay of DNA, the duplexes of which are unstable at low ionic strength but are stable in strong NaCl solutions.

Base Sequence↗

Deactivation of bilirubin oxidase by a product of the reaction of urate and O2.

The "wired" bilirubin oxidase (BOD) bioelectrocatalyst is superior to pure platinum as an electrocatalyst of the four-electron electroreduction of O(2) to water. Not only is its overpotential for O(2) reduction lower, but unlike platinum, it is not affected by organic compounds like glucose. The "wired" BOD-coated carbon cathode operates for >1 week at 37 degrees C in a glucose-containing physiological buffer solution. One of its key applications would be in a glucose-O(2) biofuel cell, which would operate in living tissues. The cathode is, however, short-lived in serum, losing its electrocatalytic activity in a few hours. Here we show that the damaging serum component is a product of the reaction of urate and dissolved oxygen. Exclusion of urate, by application of Nafion film on the cathode, improves the stability in serum.

Catalysis↗

Enzyme-amplified amperometric detection of 3000 copies of DNA in a 10-microL droplet at 0.5 fM concentration.

We reported earlier the detection of a 38-base DNA strand at 20 pM concentration by an enzyme-amplified sandwich-type amperometric assay. The assay utilized a carbon electrode on which a redox polymer, comprising a DNA capture sequence, was electrodeposited. When present in the tested solution, part of the probed sequence hybridized with the capture probe. Hybridization of its remaining part with a horseradish peroxidase (HRP)-labeled sequence resulted in the flow of an H2O2 electroreduction current, the redox polymer wired HRP forming an electrocatalyst. Here we report a > 10(4)-fold improvement in the detection limit of the assay. DNA was detected at 0.5 fM concentration when the earlier used 3.6-mm-diameter carbon electrode was replaced by a 10-microm-diameter microelectrode. The radial diffusion of electrons through the film on the microelectrode allowed the electrodeposition of a thicker film of the redox polymer, an increase in the loading of the capture sequence, and increased the collection efficiency of the electron vacancies originating in the electroreduced H2O2. When the volume probed by the microelectrode was 10 microL, as few as 3000 copies of DNA were detected.

DNA↗

Simple enzyme-amplified amperometric detection of a 38-base oligonucleotide at 20 pmol L(-1) concentration in a 30- microL droplet.

A 38-base DNA sequence has been detected at 20 pmol L(-1) concentration in 15-35- microL droplets by means of an electrochemical enzyme-amplified sandwich-type assay on a mass-manufacturable screen-printed carbon electrode. Formation of the sandwich brought the horseradish peroxidase-label of the detection sequence into electrical contact with a pre-electrodeposited redox polymer, making the sandwich an electrocatalyst for the reduction of hydrogen peroxide to water at +0.2 V (Ag/AgCl). Sensitivity twenty times better than that of a related system resulted from: 1. fivefold reduction of the noise by substituting the formerly used poly( N-vinyl imidazole)-co-acrylamide comprising redox co-polymer with poly(4-vinyl pyridine)-co-acrylamide comprising redox polymer, enabling use of the electrodes at a more oxidizing potential at which noise (the rate of non-enzyme catalyzed electroreduction currents of dissolved oxygen and hydrogen peroxide) was lower; 2. doubling of the catalytic electroreduction current upon electrodeposition of a second layer of the redox polymer on the capture sequence-containing film; and 3. doubling of the current by increasing the coverage by the capture sequence.

Base Sequence↗

An oxygen cathode operating in a physiological solution.

We report the electroreduction of O(2) to water under physiological conditions (pH 7.4, 0.15 M NaCl, 37.5 degrees C) at a current density of 5 mA cm(-2) and at a potential only 0.18 V reducing versus that of the reversible O(2)/H(2)O electrode at pH 7.4. The immobilized electrocatalyst enabling the reduction is the electrostatic adduct of bilirubin oxidase from Myrothecium verrucaria, a polyanion at pH >4.1, and the polycationic redox copolymer of polyacrylamide and poly (N-vinylimidazole) complexed with [Os (4,4'-dichloro-2,2'-bipyridine)(2)Cl](+/2+), cross-linked on carbon cloth. The current density of the rotating electrodes was O(2) transport limited up to 8.8 mA cm(-2); their kinetic limit was reached at 9.1 mA cm(-2). The operational life of the electrodes depended on their angular velocity, which defined not only the current density but also the mechanical shear stress stripping the electrocatalyst. When the electrodes were rotated at 300 rpm and were poised at -256 mV versus the potential of the reversible O(2)/H(2)O electrode, their 2.4 mA cm(-2) initial current density decreased to 1.3 mA cm(-2) after 6 days of continuous operation at 37.5 degrees C.

Animals↗