Search PubMed⌕ Search

Biomedical subjects

Yasutaka Morita

Publications and source records attributed to Yasutaka Morita.

At least 19 recordsLinked to original sources

Rapid and onsite BOD sensing system using luminous bacterial cells-immobilized chip.

A BOD monitoring system based on a bio-chip which immobilized luminous bacterium in micrometer-order holes were arrayed and fabricated by micro-machine techniques, was developed. The acrylic chip (3 cmx3 cm) comprises nine micro-holes (diameter: 700 microm or 1 mm, depth: 100 microm) arranged in a three by three array. Cells of the marine luminous bacterium, Photobacterium phosphoreum IFO 13896, which was grown at 15 degrees C for 15 h, were immobilized with 3% or 15% sodium alginate gel. BOD standard solutions or actual sample solution (approximately 10 microl) was fallen onto the cell-arrayed chip, and then the chip was incubated at 25 degrees C for 25 min. After incubation, bioluminescence from the each hole was gray-scaled and measured by a chemi-imager or newly developed onsite-type-monitoring system using a digital camera and a mobile-type personal computer. BOD values less than 16 ppm could detect by the chip, in particular, linear relationship at the concentrations between 0 and 16 ppm could be observed when luminous cells were immobilized with 3% sodium alginate gel. Steady bioluminescence was observed on the chip in the presence of BOD standard solution (GGA solution) which contained mineral elements. Furthermore, simultaneous detection of BOD values in various samples could be employed in the single chip. These results showed that the monitoring system with bio-chip could achieve high-through-put and onsite BOD detection. Our newly developed onsite-type BOD detection system which was used a digital camera and a (mobile) laptop computer was applied to measure and detect organic pollution due to biodegradable substances in wastewater treatment system. The same performance as the chemi-imager system was obtained for data of bioluminescence. The obtained BOD values showed a similar correlation with that of the conventional method for BOD determination (BOD5). These results suggested for successful achievement of high-though-put and onsite detection of BOD in practical.

Biosensing Techniques↗

Estimation of maturity of compost from food wastes and agro-residues by multiple regression analysis.

The composting process of food wastes and tree cuttings was examined on four composting types composed from two kinds of systems and added mixture of microorganisms. The time courses of 32 parameters in each composting type were observed. The efficient composting system was found to be the static aerated reactor system in comparison with the turning pile one. Using the multiple regression analysis of all the data (159 samples) obtained from this study, some parameters were selected to predict the germination index (GI) value, which was adopted as a marker of compost maturity. For example, using the regression model generated from pH, NH(4)(+) concentration, acid phosphatase activity, and esterase activity of water extracts of the compost, GI value was expressed by the multi-linear regression equation (p<0.0001). High correlations between the measured GI value and the predicted one were made in each type of compost. As a result of these observations, the compost maturity might be predicted by only sensing of the water extract at the composting site without any requirements for a large-size equipment and skill, and this prediction system could contribute to the production of a stable compost in wide-spread use for the recycling market.

Acid Phosphatase↗

Escherichia coli single-strand binding protein-DNA interactions on carbon nanotube-modified electrodes from a label-free electrochemical hybridization sensor.

An electrochemical hybridization biosensor based on the intrinsic oxidation signals of nucleic acids and proteins has been designed, that makes use of the unique binding event between Escherichia coli single-strand binding protein (SSB) and single-stranded DNA (ssDNA). The voltammetric signal from guanine oxidation significantly decreased upon binding of SSB to single-stranded oligonucleotides (probe), anchored on a single-walled carbon nanotube (SWCNT) -modified screen-printed carbon electrode (SPE). Simultaneously, oxidation of the tyrosine (Tyr) and tryptophan (Trp) residues of the SSB protein increased upon binding of the SSB protein to ssDNA and ss-oligonucleotides. After the hybridization, SSB did not bind to the double helix form, and the guanine signal could be observed along with the disappearance of the oxidation signal of the protein. The amplification of intrinsic guanine and protein oxidation signals by SWCNT, and a washing step with sodium dodecylsulfate, enabled the specific detection of a point mutation. Monitoring the changes in the guanine and protein signals upon hybridization greatly simplified the detection procedure. The detection limit of 0.15 microg/ml target DNA can be applied to genetic assays. To the best of our knowledge, this is the first work that utilizes the monitoring of SSB-DNA interactions on a solid transducer for the electrochemical detection of DNA hybridization by using intrinsic oxidation signals.

Base Sequence↗

Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes.

A novel method for DNA quantification and specific sequence detection in a highly integrated silicon microchamber array is described. Polymerase chain reaction (PCR) mixture of only 40 nL volume could be introduced precisely into each chamber of the mineral oil layer coated microarray by using a nanoliter dispensing system. The elimination of carry-over and cross-contamination between microchambers, and multiple DNA amplification and detection by TaqMan chemistry were demonstrated, for the first time, by using our system. Five different gene targets, related to Escherichia coli were amplified and detected simultaneously on the same chip by using DNA from three different serotypes as the templates. The conventional method of DNA quantification, which depends on the real-time monitoring of variations in fluorescence intensity, was not applied to our system, instead a simple method was established. Counting the number of the microchambers with a high fluorescence signal as a consequence of TaqMan PCR provided the precise quantification of trace amounts of DNA. The initial DNA concentration for Rhesus D (RhD) gene in each microchamber was ranged from 0.4 to 12 copies, and quantification was achieved by observing the changes in the released fluorescence signals of the microchambers on the chip. DNA target could be detected as small as 0.4 copies. The amplified DNA was detected with a CCD camera built-in to a fluorescence microscope, and also evaluated by a DNA microarray scanner with associated software. This simple method of counting the high fluorescence signal released in microchambers as a consequence of TaqMan PCR was further integrated with a portable miniaturized thermal cycler unit. Such a small device is surely a strong candidate for low-cost DNA amplification, and detected as little as 0.4 copies of target DNA.

Biosensing Techniques↗

Nanosystems for biosensing: multianalyte immunoassay on a protein chip.

This chapter describes the construction of addressable two-dimensional (2D) microarrays via the random fluidic self-assembly of metallic particles and the use of these arrays as platforms for constructing protein chips for bioassays. These arrays will be useful as platforms for constructing protein chips for bioassays in a broad range of applications. The basic units in the assembly are microfabricated particles, which carry a straightforward visible code, and the corresponding array template patterned on a glass substrate. On one face, the particles consist of a hydrophobic and magnetic Ni-polytetrafluoroethylene (Ni-PTFE) composite layer; the other face has a gold layer that was modified for biomolecular attachment. We use photoresist patterning to create an array template with spatially discrete microwells into which an Ni-PTFE hydrophobic composite layer and a hydrophobic photoadhesive coating are electrodeposited. After biomaterial attachment and binding processes in bulk, the particles are randomly self-assembled onto the lubricated bonding sites on the chip substrate. This self-assembly process is driven by a combination of magnetic, hydrophobic, and capillary interactions. The encoding symbol carried by each particle is used to identify the target attached to the particle surface. This model system demonstrates the utility of the protein chip array for conducting simultaneous multianalyte immunoassays of human immunoglobulins (IgA, IgG, and IgM).

Animals↗

On-chip nanoliter-volume multiplex TaqMan polymerase chain reaction from a single copy based on counting fluorescence released microchambers.

A novel method for multiplex TaqMan PCR in nanoliter volumes on a highly integrated silicon microchamber array is described. Three different gene targets, related to beta-actin, sex-determining region Y (SRY), and Rhesus D (RhD) were amplified and detected simultaneously on the same chip by using three different types of human genomic DNA as the templates. The lack of cross-contamination and carryover was shown using alternate dispensing of mineral oil-coated microchambers containing template and those without template. To confirm the specificity of our system to beta-actin, SRY, and RhD genes, we employed the larger volume PCR samples to a commercial real-time PCR system, SmartCycler. The samples were cycled with the same sustaining temperatures as with the microchamber array. Instead of the conventional method of DNA quantification, counting the number of the fluorescence released microchambers in consequence to TaqMan PCR was employed to our chip. This simple method of observing the end point signal had provided a dynamic quantitative range. Stochastic amplification of 0.4 copies/reaction chamber was achieved. The microfabricated PCR chip demonstrated a rapid and highly sensitive response for simultaneous multiple-target detection, which is a promising step toward the development of a fully integrated device for the "lab-on-a-chip" DNA analysis.

Actins↗

Electrochemical coding of single-nucleotide polymorphisms by monobase-modified gold nanoparticles.

Rapidly increasing information about the human genome requires a fast and simple method for the detection of single-nucleotide polymorphisms (SNPs). To date, the conventional SNP detection technologies have been unable to identify all possible SNPs and needed further development in cost, speed, and sensitivity. Here we describe a novel method to discriminate and code all possible combinations. SNPs were coded by monitoring the changes in the electrochemical signal of the monobase-modified colloidal gold (Au) nanoparticles. First, a chitosan layer was formed on the alkanethiol self-assembled monolayer-modified Au nanoparticle. The monobases were then attached onto the chitosan-coated Au nanoparticles through their 5' phosphate group via the formation of a phosphoramidate bond with the free amino groups of chitosan. The size of the surface-modified Au nanoparticle was found to be 8.46 +/- 1.53 nm by using atomic force microscopy. If there is a SNP in DNA and the mismatched bases are complementary to the monobase, Au nanoparticles accumulate on the electrode surface in the presence of DNA polymerase I (Klenow fragment), thus resulting in a significant change in the Au oxide wave. In this report, monobase-modified Au nanoparticles show not only the presence of a SNP, but also identify which bases are involved within the pair. Especially, the identification of a transversion SNP, which contains a couple of the same pyrimidine or purine bases, is greatly simplified. A model study was performed by using a synthetic 21-base DNA probe related to tumor necrosis factor (TNF-alpha) along with its all possible mutant combinations. This versatile nanoparticle-based electrochemical protocol is a promising candidate for coding all mutational changes.

Base Sequence↗

Application of on-chip cell cultures for the detection of allergic response.

In this report, the development of a microfluidic cell chip for monitoring allergic response is described. A rat basophilic leukemia cell line (RBL-2H3), a tumor analog of rat mucosal mast cells, has been used as a model to observe its allergic response upon antigen stimulus. The cells were cultivated on a poly(dimethylsiloxane) (PDMS) chip, the surface of which was modified by several methods. The PDMS chip, which comprised a cell cultivation chamber and microfluidic channels, was fabricated by conventional molding methods. In order to detect the allergic response, a fluorescent dye, quinacrine, was introduced inside the cell compartment that included histamine. The cells were stimulated with dinitrophenylated bovine serum albumin (DNP-BSA) after incubation with anti-DNP IgE. When exocytosis events occurred, the microfluidic system detected the fluorescent signal of quinacrine, which was released from RBL-2H3 cells by using a photomultiplier tube (PMT) fitted onto a microscope.

Animals↗

A picoliter chamber array for cell-free protein synthesis.

The completion of human genome sequencing has shifted the focus of research from genes to proteins. In this regard, a protein library chip has become a useful tool for cell-free protein synthesis. In this study, we attempted to make a highly-integrated protein chip from a DNA library using in vitro protein synthesis on a microchamber array fabricated by using PDMS (polydimethyl siloxane), a hydrophobic surface, and glass, a hydrophilic bottom substrate. These structural properties prevented cross-contamination among the chambers. The minimum volume capacity of the smallest chamber was about 1 pl. The total number of chambers per chip was 10,000 on one chip (capacity 150 pl) and 250,000 on two others (1 and 5 pl). Next, we attempted in vitro protein synthesis using this microchamber array. The fluorescence of Green Fluorescent Protein (GFP) expressed on the chamber was rapidly detected (within just 1 h). GFP expression was also successful using immobilized DNA molecules on polymer beads. DNA immobilized beads were added as the source to each microchamber. Protein was successfully synthesized from DNA immobilized beads, which allowed easy handling of the DNA molecules.

Cell-Free System↗

DNA condensation monitoring after interaction with hoechst 33258 by atomic force microscopy and fluorescence spectroscopy.

DNA condensation was only observed after the addition of Hoechst 33258 (H33258) among various types of DNA binding molecules. The morphological structural change of DNA was found to depend on the H33258 concentration. On comparison of fluorescence spectrum measurements with AFM observation, it was found that fluorescence quenching of DNA-H33258 complexes occurred after DNA condensation. Additionally, we showed that DNA condensation by H33258 was independent of sequence selectivity or binding style using two types of polynucleotides, i.e. poly(dA-dT).poly(dA-dT) and poly(dG-dC).poly(dG-dC). Moreover, it was concluded that the condensation was caused by a strong hydrophobic interaction, because the dissolution of condensed DNA into its native form on dimethyl sulfoxide (DMSO) treatment was observed. This study is the first report, which defines the DNA condensation mechanism of H33258, showing the correlation between the single molecule scale morphology seen on AFM observation and the bulky scale morphology observed on fluorescence spectroscopy.

Bisbenzimidazole↗

A rapid BOD sensing system using luminescent recombinants of Escherichia coli.

A biochemical oxygen demand (BOD) sensing system based on bacterial luminescence from recombinant Escherichia coli containing lux A-E genes from Vibrio fischeri has been developed. It was possible to use frozen cells of luminescent recombinants of E. coli as the bacterial reagents for measurement. Steady bioluminescence was observed during the incubation time between 90 and 150 min in the presence of a sole carbon source such as glucose, acetate, L-glutamate and BOD standard solution (GGA solution). This disposable bacterial reagent was applied to measure and detect organic pollution due to biodegradable substances in various wastewaters. The obtained values of this study showed a similar correlation with that of the conventional method for BOD determination (BOD5). Bacterial luminescence that was visualized with an imaging system using a charge coupled device (CCD) camera and a photomulti-counter demonstrated that this method could also be used for multi-sample detection of organic pollution due to biodegradable substances by using a microtiter plate. These results suggested for successful achievement of high-though-put detection of BOD in practical.

Biosensing Techniques↗

Micromachining microcarrier-based biomolecular encoding for miniaturized and multiplexed immunoassay.

Micromachining techniques, which originated in the microelectronics industry, have been employed to manufacture microparticles bearing an engraved dot-type signature for biomolecular encoding. These metallic microstructures are photolithographically defined and manufactured in a highly reproducible manner. In addition, the code introduced on the particle face is a straightforward visible feature that is easily recognizable with the use of optical microscopy. The number of distinct codes theoretically could be many thousands, depending on the coding element numbers. Such microparticles are, thus, with appropriate surface organic functionalizations, ideal for encoding biomolecular libraries and serving as a platform for developing high-throughput multiplexed bioassay schemes based on suspension array technology. As proof of this statement, we demonstrated that encoded microparticles tagged with antibodies to human immunoglobulin classes are capable, using imaging detection as the interrogating approach, of high sensitivity and high specificity, as well as multiplexed detection of the respective antigens in a microliter-sample volume.

Antigens↗

Multianalyte immunoassay with self-assembled addressable microparticle array on a chip.

This paper describes the random fluidic self-assembly of metallic particles into addressable two-dimensional microarrays and the use of these arrays as a platform for constructing a biochip useful for bioassays. The basic units in the assembly were the microfabricated particles carrying a straightforward visible code and the corresponding array template patterned on a glass substrate. The particles consisted of a hydrophobic and magnetic Ni-polytetrafluoroethylene (PTFE) composite layer on one face, and on the other face a gold layer that was modified for biomolecular attachment. An array template was photoresist-patterned with spatially discrete microwells in which an electrodeposited Ni-PTFE hydrophobic composite layer and a hydrophobic photo-adhesive coating were deposited. The particles, after biomaterial attachment and binding processes in bulk, were self-assembled randomly onto the lubricated bonding sites on the chip substrate, driven by a combination of magnetic, hydrophobic, and capillary interactions. The encoding symbol carried by the particles was used as the signature for the identification of each target/assay attached to the particle surface. We demonstrate here the utility of microfabricated-encoded particle arrays for conducting multianalyte immunoassays in a parallel fashion with the use of imaging detection.

Biological Assay↗

Enzyme-linked sensitive fluorometric imaging of glutamate release from cerebral neurons of chick embryos.

This paper describes a method for imaging the endogenous release of glutamate from cerebral neurons. This method is based on the reactions of glutamate oxidase and peroxidase, and on the detection of hydrogen peroxide by a fluorescent substrate of peroxidase. Glutamate has been sensitively measured in vitro in the range of 20 nM to 1 microM. We used two types of Ca(2+) channel inhibitors, MK-801 and omega-Conotoxin GVIA, which act to suppress Ca(2+) transport at postsynaptic and presynaptic neurons, respectively. MK-801 did not inhibit the increase in glutamate release after KCl stimulation, while there was no increase in glutamate release after KCl stimulation when omega-Conotoxin GVIA was used, probably due to the inhibition of voltage-activated Ca(2+) channels in the presynapse. Glutamate release and Ca(2+) flow in the synaptic regions were imaged using a laser confocal fluorescence microscope. KCl-evoked glutamate release was localized around cell bodies linked to axon terminals. This procedure allows imaging that can be sensitively detected by the fluorometric enzymatic assay of endogenous glutamate release in synapses.

Animals↗

Self-assembled DNA-conjugated polymer for novel DNA chip.

We developed DNA-conjugated polymer for DNA chip fabrication. A 30 mer probe DNA and disulfide bridges were covalently attached to the polymer side chain. The DNA-conjugated polymer can be specifically adsorbed on a gold substrate surface by a self-assembly technique. The interaction between fully matched DNA and DNA-conjugated polymer was investigated by surface plasmon resonance (SPR) technique. The DNA-conjugated polymer-modified gold surface highly recognized fully matched DNA, rather than unmatched DNA. Therefore, DNA-conjugated polymer can be used for novel DNA chip fabrication.

Base Sequence↗

Design of peptide that recognizes double-stranded DNA.

A novel molecular tool for double-stranded (ds) DNA detection using synthetic peptide is described. The peptide was designed based on the DNA binding domain of the lambda phage CRO repressor (CRO). The designed peptides contain helix-turn-helix (HTH), which is DNA binding motif. A cyclic peptide and a mutant peptide based on CRO were also designed, and the resulting affinity for dsDNA was increased. Furthermore, native amino acids of the peptide were replaced with arginine to increase the affinity for dsDNA. The affinity of these peptides for DNA binding was assessed by surface plasmon resonance (SPR) technique.

Amino Acid Sequence↗

Keratin degradation: a cooperative action of two enzymes from Stenotrophomonas sp.

A novel keratin-degrading bacterium Stenotrophomonas sp. strain D-1, isolated from deer fur, produced two types of extracellular proteins: proteolytic and disulfide bond-reducing. The results on the biochemical properties suggest that this protease belongs to the serine protease, and the disulfide bond-reducing protein could be the disulfide reductase type. None of these enzymes showed keratinolytic activity independently. However, after mixing of the two enzymes, the keratinolytic activity was increased tremendously (more than 50-fold) over that of the protease only. This keratinolytic activity was more than 2-fold higher than that of the combination with proteinase K (also known for its high keratinolytic activity). Since the two enzymes discovered in this study acted cooperatively and resulted in higher keratinolytic activity, a new mechanism of keratin degradation has been revealed. To our knowledge, this is the first report on the cooperative action of two enzymes resulting in the effective degradation of keratin.

Bacterial Proteins↗