Bioactive and bioresorbable cellular cubic-composite scaffolds for use in bone reconstruction.

We used a novel composite fibre-precipitation method to create bioactive and bioresorbable cellular cubic composites containing calcium phosphate (CaP) particles (unsintered and uncalcined hydroxyapatite (u-HA), alpha-tricalcium phosphate, beta-tricalcium phosphate, tetracalcium phosphate, dicalcium phosphate dihydrate, dicalcium phosphate anhydrate or octacalcium phosphate) in a poly-D/L-lactide matrix. The CaP particles occupied greater than or equal to 70 wt% (greater than or equal to 50 vol%) fractions within the composites. The porosities of the cellular cubic composites were greater than or equal to 70% and interconnective pores accounted for greater than or equal to 70% of these values. In vitro changes in the cellular geometries and physical properties of the composites were evaluated over time. The Alamar Blue assay was used to measure osteoblast proliferation, while the alkaline phosphatase assay was used to measure osteoblast differentiation. Cellular cubic C-u-HA70, which contained 70 wt% u-HA particles in a 30 wt% poly-D/L-lactide matrix, showed the greatest three-dimensional cell affinity among the materials tested. This composite had similar compressive strength and cellular geometry to cancellous bone, could be modified intraoperatively (by trimming or heating) and was able to form cortico-cancellous bone-like hybrids. The osteoinductivity of C-u-HA70, independent of biological growth factors, was confirmed by implantation into the back muscles of beagles. Our results demonstrated that C-u-HA70 has the potential as a cell scaffold or temporary hard-tissue substitute for clinical use in bone reconstruction.

Absorbable Implants↗

Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine model.

The in vitro multidirectional flexibility analysis was conducted to investigate the initial biomechanical effect of biomimetic artificial intervertebral disc replacement from either anterior or posterior approach in a cadaveric lumbosacral spine model. Two designs of anterior total and posterior subtotal artificial discs were developed using bioactive three-dimensional fabric and bioresorbable hydroxyapatite/poly-l-lactide material (3DF disc). Both models were designed to obtain the stable interface bonding to vertebral endplates with maximum surface area occupation. Using seven cadaveric lumbosacral spines, the following three anterior reconstruction methods were sequentially performed at L4-5 level: anterior 3DF disc replacement; anterior BAK cages (BAK); and posterior pedicle screw fixation and anterior BAK cages combined (BAK + PS). The L2-3 level received two methods of posterior reconstructions: subtotal 3DF disc replacement (two implants), and posterior interbody cages and pedicle screw fixation (PLIF). Six unconstrained pure moments were applied and three-dimensional segmental motions were measured with an optoelectronic motion measurement system. The center of rotation (COR) calculation was conducted radiographically using flexion-extension films. Both anterior and posterior 3DF replacements statistically demonstrated equivalent range of motions (ROMs) in all loading modes compared to intact segment. Anterior BAK, BAK + PS, and PLIF demonstrated significantly lower ROMs when compared to intact and 3DF groups (P<0.05). The 3DF reconstruction tended to realign the COR to the posterior third or surrounding position at the operative disc level. The stand-alone lumbar 3DF disc replacement demonstrated biomechanical characteristics nearly equivalent to the intact spinal segments even through anterior or posterior approach in vitro, suggesting an excellent clinical potential.

Absorbable Implants↗

In vivo evaluation of a porous hydroxyapatite/poly-DL-lactide composite for use as a bone substitute.

We investigated the biocompatibility, osteoconductivity, and biodegradability of a porous composite of hydroxyapatite (HA) and poly-DL-lactide (PDLLA) implanted into rabbit femoral condyles and compared it with porous HA. Six weeks after implantation, the HA/PDLLA was covered with bone and contacted the bone directly. The amount of newly formed bone in the pores was similar in both materials during the examined period. The newly formed bone in the HA/PDLLA tended to increase over 26 weeks, but that in the HA did not show a significant increase after 12 weeks. By 26 weeks, remodeling of the newly formed bone in the pores was seen and bone marrow tissue was found in the pores of the HA/PDLLA. The porous HA/PDLLA was resorbed much faster than the porous HA. Porous HA/PDLLA was resorbed continuously through bone formation and remodeling. Conversely, porous HA was scarcely resorbed throughout the period. HA/PDLLA is thought to be degraded almost completely after about 1 year, and in this study, porous HA/PDLLA showed excellent osteoconductivity and faster resorption than HA. Therefore, HA/PDLLA might be a desirable material for bone substitutes.

Animals↗

A 5-7 year in vivo study of high-strength hydroxyapatite/poly(L-lactide) composite rods for the internal fixation of bone fractures.

The biocompatibility and biodegradation of hydroxyapatite (HA)/poly(L-lactide) (PLLA) composite bone implant rods were studied using two types of HA particles as reinforcing fillers, uncalcined-HA (u-HA) or calcined-HA (c-HA). Composite rods of u-HA/PLLA and c-HA/PLLA were implanted into the distal femurs of 25 rabbits. Four of these rabbits lived for more than 5 years after implantation, with one living for 7 years 4 months. Samples were retrieved after the rabbits died naturally and specimens were examined by light microscopy and scanning electron microscopy (SEM). For u-HA/PLLA, the shrinkage of the rods progressed further after 4 years, and some were almost completely resorbed. We could not find traces of the rod in some sections from more than 6 years. Remodeled bone encircled the residual material, and trabecular bone bonded directly to the rod was found toward the center. For u-HA/PLLA 30%, results were similar to u-HA/PLLA 40%, and the cross-sectional area had decreased by 4.0% at over 7 years. Most of the PLLA had been released from the rods. Neither obvious osteolytic nor osteoarthritic changes were found after 4 years.

Animals↗

A biomechanical and histological evaluation of a bioresorbable lumbar interbody fusion cage.

Novel spinal interbody fusion cages made of bioactive and bioresorbable composites by a unique forging process were developed. Previous in vitro study demonstrated that these cages marked excellent biomechanical values. The purpose of the present in vivo study was to evaluate the viability and advantage of this forged composite of uncalcined hydroxyapatite/poly L-Lactide (F-u-HA/PLLA) cage radiographically, biomechanically, and histologically, when compared to conventional autologous iliac bone (AIB) and carbon fiber cage (CFC). Twenty-five mature sheep underwent posterior lumbar interbody fusion at L2-3 level with pedicle screws system made of titanium. Three types of interbody fusion implants were grafted: AIB (n = 7), CFCs (n = 9), F-u-HA/PLLA cages (n = 9). Two types of cages were packed with autologous fragmented cancellous bone harvested locally. All animals were euthanized at 120 days after surgery. The fusion scoring using the coronal view CT scans was designed to three-dimensionally evaluate fusion quality within and around cages. The mean CT scores of three groups were 33.3 points, 35.0 points, and 33.6 points in AIB, CFC, and F-u-HA/PLLA cage groups, respectively (full-score: 56 points). Statistical differences were not detected among the three groups. The mean range of motion values among fused groups had no significant difference under all pure loadings. The range of motion showed strong and significant correlation with the CT fusion scores. Histologic results demonstrated that F-u-HA/PLLA cages contacted with the surrounding bone directly, and CFC was encircled with thick fibrous tissue layers without any sign of inflammation around cages. The fusion quality of fused spinal segment using F-u-HA/PLLA cages was equal to that of AIB or CFCs both radiographically and biomechanically. In the histological observation, biocompatibility of F-u-HA/PLLA cage was obviously superior to CFC. It has been confirmed that the novel bioactive and bioresorbable cages had valuable advantages over existing CFC for use in spinal reconstructive surgery.

Absorbable Implants↗

Enhanced repair of large osteochondral defects using a combination of artificial cartilage and basic fibroblast growth factor.

The purpose of this study was to examine the efficacy of a combination of artificial cartilage and basic fibroblast growth factor (bFGF) for the repair of large osteochondral defects. The artificial cartilage was a three-dimensional fabric (3-DF) composed of an ultra-high molecular weight polyethylene fiber with a triaxial three-dimensional structure. We implanted 3-DF impregnated with type I collagen gel containing 500 ng of bFGF (bFGF-treated group) or 3-DF impregnated with type I collagen gel alone (non-treated group) into a large full-thickness osteochondral defect (6 x 6 x 3 mm) of the patellar groove of rabbits. The defect area was examined grossly, histologically and biomechanically 4-48 weeks after surgery. Bone ingrowth into and around the 3-DF was evaluated with micro-computed tomography (micro-CT). Addition of bFGF to the 3-DF greatly accelerated cartilage formation on the articular surface and subchondral bone formation into and around the 3-DF, and improved biomechanical properties. These findings suggest that a combination of artificial cartilage and bFGF is clinically useful in cases involving large osteochondral defects.

Animals↗

The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles/poly l-lactide (F-u-HA/PLLA).

Here we document the complete process of bioresorption and bone replacement of rods made of forged composites of unsintered hydroxyapatite particles/poly l-lactide (F-u-HA/PLLA) implanted in the femoral medullary cavities of rabbits. Bioresorption, osteoconductive bioactivity and bone replacement were compared in three implantation sites. In the first site, the end of the rod was located near the endosteum in the proximal medullary cavity. In the second, the rod was located at the centre of the bone marrow space without contacting the endosteum. In the third, the rod was in direct contact with cancellous bone within the distal femoral condyle. Micro-computerised tomography, scanning electron microscopy and photomicrographs of stained sections were used to document the complete process of bioresorption and bone replacement. At the first implantation site, the rod was completely resorbed and unbound u-HA particles were detected in and around the endosteum 5-6 years after implantation. At the second site, the rod showed significant shrinkage 4-5 years after implantation due to the release of almost all the PLLA, although a contracted cylindrical structure containing a few u-HA persisted even after approximately 6 years. At the third site, u-HA particles were almost completely replaced with bone after 5-6 years. Conversely, PLLA-only rods showed little bone conduction, and small amounts of degraded PLLA debris and intervening some tissue persisted even after long periods. Namely, the u-HA/PLLA composites were replaced with bone in the distal femoral condyle, where they were in direct contact with the bone and new bone formation was anatomically necessary. By contrast, composite rods were resorbed without replacement in the proximal medullary cavity, in which new bone growth was not required. We therefore conclude that the F-u-HA30/40 composites containing 30 wt%/40 wt% u-HA particles are clinically effective for use in high-strength bioactive, bioresorbable bone-fixation devices with the capacity for total bone replacement.

Absorbable Implants↗

Multidirectional flexibility analysis of cervical artificial disc reconstruction: in vitro human cadaveric spine model.

OBJECT: This in vitro experimental study was conducted to investigate the initial biomechanical effect of artificial intervertebral disc replacement in the cervical spine. The multidirectional flexibility of replaced and adjacent spinal segments were analyzed using a cadaveric cervical spine model. METHODS: The following three cervical reconstructions were sequentially performed at the C5-6 level after anterior discectomy in seven human cadaveric occipitocervical spines: anterior artificial disc replacement with a bioactive three-dimensional (3D) fabric disc (FD); anterior iliac bone graft; and anterior plate fixation with iliac bone graft. Six unconstrained pure moments were applied with a 6-df spine simulator, and 3D segmental motions at the operative and adjacent segments were measured with an optoelectronic motion measurement system. The 3D FD group demonstrated statistically equivalent ranges of motion (ROMs) when compared with intact values in axial rotation and lateral bending. The 45% increase in flexion-extension ROM was demonstrated in 3D FD group; however, neutral zone analysis did not reach statistical significance between the intact spine and 3D FD. The anterior iliac bone graft and iliac bone graft reconstructions demonstrated statistically lower ROMs when compared with 3D FD in all loading modes (p < 0.05). The adjacent-level ROMs of the 3D FD group demonstrated nearly physiological characteristics at upper and lower adjacent levels. Excellent stability at the interface was maintained during the whole testing without any device displacement and dislodgment. CONCLUSIONS: The stand-alone cervical 3D FD demonstrated nearly physiological biomechanical characteristics at both operative and adjacent spinal segments in vitro, indicating an excellent clinical potential for cervical artificial disc replacement.

Bone Plates↗

Two-year observation of artificial intervertebral disc replacement: results after supplemental ultra-high strength bioresorbable spinal stabilization.

OBJECT: This 2-year experimental study was conducted to investigate the efficacy of a bioactive three-dimensional (3D) fabric disc for lumbar intervertebral disc replacement. The authors used a bioresorbable spinal fixation rod consisting of a forged composite of particulate unsintered hydroxyapatite/poly-L-lactide acid (HA/PLLA) for stability augmentation. The biomechanical and histological alterations as well as possible device-related loosening were examined at 2 years postoperatively. METHODS: Two lumbar intervertebral discs (L2-3 and L4-5) were replaced with the 3D fabric discs, which were augmented by two titanium screws and a spanning bioresorbable rod (HA/PLLA). The segmental biomechanics and interface bone ingrowth were investigated at 6, 15, and 24 months postoperatively, and results were compared with the other two surgical groups (3D fabric disc alone; 3D fabric disc with additional anterior instrumentation stabilization). The 3D fabric disc and HA/PLLA-spinal segments demonstrated segmental mobility at 15 and 24 months; however, the range of motion (ROM) in flexion-extension decreased to 49 and 40%, respectively, despite statistically equivalent preserved torsional ROM. Histologically there was excellent osseous fusion at the 3D fabric disc surface-vertebral body interface. At 2 years posttreatment, no adverse tissue reaction nor aseptic loosening of the device was observed. CONCLUSIONS: Intervertebral disc replacement with the 3D fabric disc was viable and when used in conjunction with the bioresorbable HA/PLLA spinal augmentation. Further refinements of device design to create a stand-alone type are necessary to obviate the need for additional spinal stabilization.

Animals↗

Long-term study of high-strength hydroxyapatite/poly(L-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits.

Biodegradation of hydroxyapatite (HA)/poly(L-lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u-HA) or calcined HA (c-HA). Composite rods of u-HA/PLLA and c-HA/PLLA containing 30 or 40% (w/w) HA were implanted in the distal femur of 21 rabbits, and specimens were examined by light microscopy, scanning-electron microscopy (SEM), and transmission-electron microscopy (TEM) 2-4 years later. For u-HA/PLLA, trabecular bone bonding directly onto the rod was maintained for up to 2 years. By 3 years, surface collapse had begun, and the implants were shrinking. By 4 years, they had shrunk further, with complete bone encapsulation. The u-HA particles were small and needle shaped in the peripheries, and TEM confirmed their resorption. The cross-sectional area after 4 years decreased by 23.3+/-8.4%. The mean ratio of bony ingrowth to the initial cross-sectional area around the shrunken rods was 6.7+/-1.3 %. The viscosity molecular weight of PLLA reduced from 2 x 10(5) to less than 1 x 10(3). Thus, most of the PLLA had released from the rods. The c-HA/PLLA implants also showed good osteoconductivity, but shrinkage and infiltration of histiocytes were less. No osteolytic or osteoarthritic changes were found.

Absorbable Implants↗

Comparative biomechanical analysis of a cervical cage made of an unsintered hydroxyapatite particle and poly-L-lactide composite in a cadaver model.

STUDY DESIGN: A new cage made from a forged composite of unsintered hydroxyapatite particles and poly-L-lactide (F-u-HA/PLLA) is compared biomechanically with the Ray threaded fusion cage. OBJECTIVES: To compare the stability imparted to the human cadaveric spine by two different threaded cervical cages and the effect of cyclic loading on construct stability. SUMMARY OF BACKGROUND DATA: Threaded cages have been developed for use in anterior cervical interbody fusions to provide initial stability during the fusion process. However, metallic instrumentation has several limitations. Recently, totally bioresorbable bone fixation devices made of F-u-HA/PLLA have been developed, including a cage for spinal interbody fusion. However, no biomechanical study has compared the F-u-HA/poly-L-lactide (PLLA) cage with metallic cages. METHODS: For this study, 12 fresh ligamentous human cervical spines (C4-C7) were used. After anterior discectomy across C5-C6, stabilization was achieved with the F-u-HA/PLLA cage in six spines and with the Ray threaded fusion cage in the remaining six spines. Biomechanical testing of the spines was performed with six degrees of freedom before and after stabilization, and after cyclic loading of the stabilized spines (5000 cycles of flexion-extension at 0.5 Nm). RESULTS: The specimens stabilized with either the F-u-HA/PLLA cage or the Ray cage were significantly more stable than the discectomy case in all directions except in extension. In extension, both groups were stiffer, although not at a significant level (P > 0.05). After fatigue, the stiffness, as compared with that in the prefatigue case, decreased in both groups, although not at a significant level. The Ray cage group exhibited better stability than the F-u-HA/PLLA cage group in all directions, although a significant difference was found only in right axial rotation. CONCLUSIONS: The F-u-HA/PLLA cage has the possibility to supplant the use of metallic devices in interbody fusions of the cervical spine.

Biomechanical Phenomena↗

Bone ingrowth fixation of artificial intervertebral disc consisting of bioceramic-coated three-dimensional fabric.

STUDY DESIGN: The bone-bonding characteristic of the new artificial intervertebral disc consisting of bioceramic-coated three-dimensional fabric was evaluated mechanically and histologically in an in vivo sheep model. OBJECTIVES: To investigate the mechanical properties and the histologic appearance of the interface between the three-dimensional fabric disc and the vertebral body, and to evaluate these alterations in vivo under a spinal segmentally mobile condition. SUMMARY OF BACKGROUND DATA: Bone ingrowth to the bioceramic-coated three-dimensional fabric surface had been demonstrated already under a stable environment in preliminary animal studies. METHODS: For this study, 20 sheep underwent two-level lumbar intervertebral disc replacement with three-dimensional fabric discs (Group I) or bioceramic spacers as a comparative material (Group II). All operative segments were stabilized temporarily with spinal instrumentation for the initial ingrown phase. Four animals each were killed at 4, 6, 15, and 24 months in Group I and at 6 months in Group II, and the operative segments were subjected to either a detachment test or histologic evaluation. RESULTS: The interfacial tensile strength at 6 months was significantly higher in Group I than in Group II. No significant decrease in tensile strength was detected until 24 months after surgery in Group I. Histologically, bone ingrowth to the three-dimensional fabric surface was observed 4 months after surgery, and no aseptic loosening occurred until 24 months after surgery. CONCLUSIONS: The findings show that the three-dimensional fabric disc was firmly fixed to the vertebral body by bone ingrowth, and that this biologic fixation was preserved even under the spinal segmentally mobile condition.

Animals↗

Mechanical evaluation of novel spinal interbody fusion cages made of bioactive, resorbable composites.

Osteoconductive and totally bioresorbable spinal/cervical interbody fusion cages were fabricated from a forged composite of raw particulate hydroxyapatite/poly L-lactide (u-HA/PLLA) with an u-HA 40wt% fraction (F-u-HA 40). The mechanical strengths of three types of cages, designed for open-box, screw and cylinder constructs, were compared with those of existing metal and carbon-fiber/polymer cages. Compressive strengths of these composite cages surpassed those of existing metal and carbon-fiber cages. Fatigue resistance to alternate and static compressive loading persisted for longer than the minimum period (6 months) necessary for spinal devices in simulated body fluid (SBF) at 37 degrees C. These novel interbody fusion cages await clinical application in humans.

Absorbable Implants↗

Artificial intervertebral disc replacement using bioactive three-dimensional fabric: design, development, and preliminary animal study.

STUDY DESIGN: A new artificial intervertebral disc was developed, and its intrinsic biomechanical properties, bioactivity, and the effectiveness as a total disc replacement were evaluated in vitro and in vivo. OBJECTIVES: To introduce a new artificial intervertebral disc and to evaluate the in vitro mechanical properties, fusion capacity to bone, and segmental biomechanics in the total intervertebral disc replacement using a sheep lumbar spine. SUMMARY OF BACKGROUND DATA: The loss of biologic fusion at the bone-implant interface and prosthetic failures have been reported in previous artificial discs. There have been no clinically applicable discs with detailed experimental testing of in vivo mechanics and interface fusion capacity. METHODS: The artificial intervertebral disc consists of a triaxial three-dimensional fabric (3-DF) woven with an ultra-high molecular weight polyethylene fiber, and spray-coated bioactive ceramics on the disc surface. The arrangement of weave properties was designed to produce mechanical behavior nearly equivalent to the natural intervertebral disc. Total intervertebral disc replacement at L2-L3 and L4-L5 was performed using 3-DF disc with or without internal fixation in a sheep lumbar spine model. The segmental biomechanics and interface histology were evaluated after surgery at 4 and 6 months. RESULTS: The tensile-compressive and torsional properties of prototype 3-DF were nearly equivalent to those of human lumbar disc. The lumbar segments replaced with 3-DF disc alone showed a significant decrease of flexion-extension range of motion to 28% of control values as well as partial bony fusion at 6 months. However, the use of temporary fixation provided a nearly physiologic mobility of the spinal segment after implant removal as well as excellent bone-disc fusion at 6 months. CONCLUSION: An artificial intervertebral disc using a three-dimensional fabric demonstrated excellent in vitro and in vivo performance in both biomechanics and interface histology. There is a potential for future clinical application.

Animals↗

Influence of bioresorbable, unsintered hydroxyapatite/poly-L-lactide composite films on spinal cord, nerve roots, and epidural space.

The effect of forged unsintered hydroxyapatite/poly-L-lactide (u-HA/PLLA) composite films on spinal cord and nerve roots and its degradation behavior and osteoconductivity in epidural space were compared with those of calcined HA (c-HA)/PLLA and unfilled PLLA films. Partial laminectomy was performed on 20 rabbits, and u-HA/PLLA and PLLA films were implanted in the intervertebral space. Total laminectomy was performed on 30 rabbits to implant u-HA/PLLA, c-HA/PLLA, and PLLA films in both epidural and subcutaneous spaces. For up to 50 weeks, there were no histological changes in the spinal cord or nerve root, and no inflammatory cell infiltration into the epidural space around the films. The rate of decrease in viscosity average molecular weight of both composite films was initially higher than that of PLLA but eventually became lower, although there was no difference in the degradation behavior of the three films in either the epidural or subcutaneous spaces after 50 weeks. Scanning electron microscopic and energy-dispersive X-ray analysis indicated calcium phosphate deposits on the surface of composite films with new bone formation from 4 weeks. The u-HA/PLLA composite film therefore has good biocompatibility, osteoconductivity, and fast primary degradation rate, which may prove compatible with application to spinal surgery.