OBJECTIVES: To study the incidence of fetal loss in threatened abortion after detection of embryonic/fetal heart activity. METHODS: A prospective study was performed on pregnant women with clinically diagnosed threatened abortion between 6 and 14 weeks of gestation. All had a good menstrual history and the calculated gestational age using crown-rump length in the first trimester ultrasound was in agreement. Embryonic/fetal heart rate measurements were obtained by a 5 MHz vaginal probe using M-mode and real-time B mode imaging. All cases were followed up with respect to pregnancy outcomes. The data were analyzed using the SPSS computer program. RESULTS: Eighty-seven pregnant women were included in the study. There were three pregnancies (3.4%) which resulted in fetal loss before 20 weeks of gestation. In viable pregnancies, the mean embryonic/fetal heart rate increased with advancing gestational age. The individual values of embryonic/fetal heart rate for fetal losses were within the reference range. CONCLUSIONS: The incidence of fetal loss in threatened abortion after detection of embryonic/fetal heart activity was 3.4%. There was no evident pattern of bradycardia or tachycardia that signaled the incipient of viability.
Explore the source record for details and available documents.
OBJECTIVE: To assess the value of femur length shortening for prenatal detection of Down syndrome in a Thai population. METHOD: A prospective study was performed by experienced perinatologists on 3137 women undergoing second-trimester amniocentesis, between 16 and 24 weeks of gestation, for the indications of advanced maternal age and past history of chromosomal abnormality. Biparietal diameter and femur length measurements were obtained before the procedures. Regression equations relating biparietal diameter to femur length were used to calculate observed femur length/expected femur length ratio in the chromosomally normal and Down syndrome fetuses. Sensitivity, specificity, false-positive rate and likelihood ratio of a positive test result at various observed femur length/expected femur length ratios for detection of Down syndrome were calculated. A receiver-operator characteristic curve was used to determine threshold screening ratio. RESULTS: There were 3084 chromosomally normal pregnancies, 26 fetuses with Down syndrome (1:118), and 27 other chromosomal abnormalities. The relationship between femur length and biparietal diameter (BPD) was: expected femur length=-7.631+0.814 BPD, R(2)=0.78, P<0.001). Femur length in Down syndrome fetuses was significantly shorter than in normal fetuses (P<0.001). A ratio of 0.91 for observed femur length/expected femur length yielded a sensitivity of 42.3%, specificity of 86.2%, false positive rate of 13.8% and likelihood ratio of a positive test result of 3.07 (95% CI 1.94-4.84) for detection of Down syndrome. CONCLUSIONS: In this study, femur length shortening in the second trimester appears to be a useful screening parameter for fetal Down syndrome in a Thai population.
Explore the source record for details and available documents.
A prospective descriptive cross-sectional study was undertaken at the Department of Obstetrics and Gynecology, Faculty of Medicine, Chulalongkorn University to establish a reference interval for fetal crown-rump length (CRL) in a Thai population using transvaginal ultrasound. This study was performed on normal pregnant women registered at the antenatal clinic in their first trimester. All had a good menstrual history. CRL measurement was obtained by a 5 MHz vaginal probe. All of the newborns were proved to be normal at birth. We constructed and compared CRL (mm) relating to gestational age (GA) (days). Five hundred and forty seven cases were enrolled into the study. CRL was correlated with gestational age. The best fit regression equation was the quadratic model: CRL (mm) = -13.872 - 0.014 GA (day) + 0.0097 GA (day)2, R = 0.92, p < 0.0001). Centiles and a chart for CRL derived from the regression equation are presented. In conclusion, a reference interval for fetal crown-rump length in a Thai population has been established. This data may be useful in the early detection of genetic or environmental disorders affecting fetal growth in the first trimester of pregnancy.
Explore the source record for details and available documents.
Short fetal acoustic stimulation test (FAST) was prospectively studied in 604 high risk pregnancies after 28 weeks of gestation. Fetal heart rates were recorded 3 minutes before and 5 minutes after fetal acoustic stimulation. The results of the tests performed within a week of delivery were compared with perinatal outcomes. Reactive response to short FAST occurred in 597 cases (98.8%) while nonreactive response was found in 7 cases (1.2%). Nine fetuses were considered poor outcomes. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of short FAST to predict poor fetal outcomes were 66.7, 99.8, 85.7, 99.5, and 99.3 per cent, respectively. Short FAST has high specificity, negative predictive value and accuracy for prediction of poor perinatal outcome. This rapid test should be used as a screening method for antepartum assessment of fetal well-being in a busy antenatal clinic.
Explore the source record for details and available documents.
We developed a nomogram for transverse cerebellar diameter (TCD) in Thai fetuses by recruitment of 153 normal pregnant women in the first trimester. The gestational age calculated by the certain last menstrual period and the first trimester ultrasound were in agreement. The pregnant women were stratified into 4 groups and scanned at four weekly intervals: group A was first scanned at 14 weeks, group B at 15 weeks, group C at 16 weeks, and group D at 17 weeks. A total of 699 measurements from 14 to 40 weeks of gestation were obtained. The data were analyzed for mean and standard deviation; and the best fit mathematical model was derived. The TCD grew progressively along gestational age. The growth rate was slightly less than that of a Western study after 28 weeks of gestation. This could serve as the basis for gestational dating in fetuses with aberrant fetal growth.
OBJECTIVE: To determine the sonographic appearances in pregnant women who presented with vaginal bleeding in the first 20 weeks of gestation. METHOD: Pregnant women of under 20 gestational weeks diagnosed clinically as threatened abortion were recruited for ultrasound scan at the Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Faculty of Medicine, Chulalongkorn University. The sonographic findings were reported as viable pregnancy, anembryonic pregnancy, embryonic death, incomplete abortion, complete abortion, ectopic pregnancy, molar pregnancy and inconclusive findings. Patients with inconclusive findings were followed weekly until final diagnoses were established. All patients were followed-up to 20 weeks or until the final outcomes were revealed. RESULTS: Two hundred and sixty eight pregnant patients were enrolled. Ultrasound scans demonstrated 100 viable fetuses (37.3%), 73 embryonic deaths (27.3%), 46 anembryonic pregnancies (17.2%), 6 molar pregnancies (2.2%), 3 ectopic pregnancies (1.1%), 14 complete abortions (5.2%) and 26 inconclusive findings (9.7%). Follow-up scan on patients with inconclusive findings revealed 9 anembryonic pregnancies (3.3%), 9 incomplete abortions (3.3%), 1 embryonic death (0.4%) and 1 viable pregnancy (0.4%). Six patients (2.3%) were lost to follow-up. The viable pregnancy rate according to maternal age was highest at the maternal age of 25 to 29 years old (49%), whereas, it was lowest at the maternal age of 40 to 44 years old (0%). The viable pregnancy rate according to gestational age was highest at 6 to 8 weeks (61.2%), whereas, it was lowest at 18 to 20 weeks (20%). CONCLUSION: Sonographic findings in patients with clinically diagnosed threatened abortion demonstrated viable pregnancies in around one-third of the cases. Use of ultrasound in clinically diagnosed threatened abortion may assist clinicians in establishing a definite diagnosis so that appropriate care could be offered to the patients.
The purpose of this study was to determine the incidence of vaginal vault granulation after total abdominal hysterectomy using polyglactin (Vicryl) for vault closure. Fifty women who underwent total abdominal hysterectomy for benign and elective conditions were included into the study. Standard surgical technique of total abdominal hysterectomy was employed except for closure of the vaginal vault performed by interrupted figure-of-eight sutures using No. 1 polyglactin. All patients were prospectively followed-up at approximately 6 weeks postoperatively and vaginal vault granulation was diagnosed as present or absent. It was found that 5 patients had vaginal vault granulation without any symptoms, giving the incidence of 10 per cent. One patient who developed vault granulation had postoperative morbidity from cuff cellulitis. The remaining 49 patients had no immediate postoperative complications.