Pulmonary function in a non-pulsatile pulmonary circulation.

The authors suggested that a mammal immediately accommodates well to nonpulsatile flow in the systemic circulation. In the current study, nonpulsatile pulmonary blood flow using a centrifugal pump was established in chronic models to analyze its influence on the pulmonary circulation. A pulsatile right ventricular assist device (RVAD) was implanted to draw blood from both the right atrium and ventricle and send blood to the pulmonary artery in six goats. After 2 weeks, the pulsatile pump was quickly replaced with a centrifugal pump without anesthesia, and a 100% non-pulsatile pulmonary blood flow was obtained. Cardiac output was kept at 80-120 ml/kg/min during the experiments. No changes were observed in hemodynamic parameters, including pulmonary arterial pressure, pulmonary vascular resistance index, and blood gas data, after the immediate depulsation of the pulmonary blood flow. There was also no significant change in the ventral to dorsal tissue blood flow ratio of the lower lobe of the right lung, which was calculated by a colored microsphere method, between pulsatile and non-pulsatile pulmonary blood perfusion. These results suggest that pulmonary function, including blood flow distribution, is not affected by non-pulsatile pulmonary circulation for periods up to 14 days.

Animals↗

Permeation of silicone oil through a diaphragm in an electrohydraulic ventricular assist system.

This study was designed to investigate the permeation of silicone oil through a pump diaphragm made of Pellethane in the authors' electrohydraulic ventricular assist system (EHVAS) and to evaluate influences on organ function. The permeability of the diaphragm to silicone oil was investigated by in vitro experiments. Influences on organ function were evaluated in five goats with an EHVAS by monitoring serum silicon levels (SSi), blood chemical parameters, and histologic findings. Elevation of silicone oil levels in Pellethane sheets immersed in silicone oil demonstrated that the Pellethane diaphragm was, in fact, permeable to silicone oil. The permeation rate of silicone oil was calculated to be 1.75 ml/year in the authors' EHVAS from the data of a diffusion apparatus test. Serum silicon levels did not increase during the EHVAS pumping, and renal and hepatic function were not affected. No abnormality or deposit suggestive of silicone oil was observed. However, the problem of permeation of silicone oil through the pump diaphragm must be solved to allow for a circulatory assist device for long-term use.

Animals↗

Influence of an impeller centrifugal pump on blood components in chronic animal experiments.

A chronic animal experiment was designed to examine the changes in blood components induced by the use of a centrifugal pump (CP). In the pump, an impeller spins in a blood chamber by magnetic coupling with a rotating magnet outside the blood chamber. A pulsatile ventricular assist device was implanted between the left atrium and the descending aorta in four goats weighing from 63 to 75 kg; the CP was installed to replace the assist device, without surgery and anesthesia, more than 2 weeks later when the influences of implantation surgery were diminished. Antithrombotic therapy was performed with oral administration of an antiplatelet agent, cilostazol, a cyclic adenosine monophosphate phosphodiesterase at a dose of 30 mg/kg/day. No significant differences were observed in any of the following parameters: 1) hematocrit, 2) plasma free hemoglobin, 3) lactic acid dehydrogenase, 4) adenosine diphosphate, 5) platelet count, 6) fibrinogen, and 7) antithrombin III, between the data before and after the use of the CP, nor were deformation or pseudopods of platelets seen. The CP developed in the authors' institute and evaluated in this study did not damage blood components, and it proved to be a promising device for long-term use.

Adenosine Diphosphate↗

An abdominally placed, implantable left ventricular assist system for long-term use.

An implantable left ventricular assist system was developed for long-term use. The system includes an implantable blood pump, a portable control drive unit (CDU), and a monitoring system. The blood pump was designed to be positioned in the left abdominal wall and was made of segmented polyether polyurethane. A percutaneous drive line connected it to the external CDU. The CDU included a continuous pump performance monitoring system that measured electrical impedance between the two metal connectors of a blood pump. In animal experiments using six adult goats, the pump was installed between the left ventricular apex and the descending aorta, and it was placed in the abdominal wall. No antithrombogenic agents were administered during the course of the experiment. This LVAS was easy to use and provided stable hemodynamic conditions for > 8 weeks. Pump output (Op), estimated by impedance, was linearly related to Op measured with an electromagnetic flowmeter. Pump performance was effectively estimated, and the fill-empty drive was well controlled by impedance. There were no significant abnormal hematologic or blood chemistry values, no signs of infection around the pump pocket (except in one animal), and no obvious thromboembolic symptoms. Maximum flow was 6.7 L/min with use of a prototype portable CDU (dimensions, 500 x 168 x 435 mm; weight, 16 kg). In conclusion, this LVAS is promising for long-term clinical use.

Abdomen↗

Development and evaluation of components for a totally implantable artificial heart system.

The authors have been developing an electrohydraulic (EH) artificial heart system for total implantation. This system consists of intrathoracic ventricles, an abdominally placed EH actuator, flexible silicone oil conduits, externally coupled transcutaneous energy transfer (TET) system, transcutaneous optical telemetry (TOT) system, internal battery, and internal control drive unit. Fitting was evaluated in chronic animal experiments as a pneumatic system in 11 goats weighing 55.2 +/- 4.2 kg and 3 calves of 52.3 +/- 1.2 kg. The longest survival time in calves was 111 days, and that in goats was 51 days. The assembled EH pump was implanted in two goats of 49 and 50 kg as an acute experiment, and 4.2-6.7 L/min of cardiac output was maintained. For the TET system, an internal coil 3 cm in diameter was implanted to make an arch covered by skin. Electric energy was transmitted from the external to the internal coil, and energy of about 20 W was carried through wires to an external load. The DC-to-DC efficiency of the system was 76-83% for 40 days. The TOT system with internal light emitting diodes and external photodiodes also was evaluated in a goat. Disalignment of up to 12 mm was tolerated. Although more improvement is necessary, most of the components showed characteristics desirable for a totally implantable system.

Animals↗

In vitro and in vivo assessment of an intravenous axial flow pump for right heart assist.

Right ventricular (RV) function is a limiting factor in maintaining systemic circulation with circulatory assist. There is, however, no easy way to institute RV assist, such as the intraarterial axial flow pump (Hemopump) used for left heart assist. In this study, the feasibility and hemodynamic effect of intravenous use of an axial flow pump was examined. A pump system was developed with an outflow cannula and an impeller that were newly designed for intravenous insertion with a Hemopump driving system. The pump system characteristics using goat blood at a hematocrit of 26% indicated that maximum flow at a pressure differential against 40 mmHg is 3.2 l/min at a pump speed of 28,000 rpm. The pump was tested in adult goats by intravenous insertion through a 14 mm, low porosity graft anastomosed to the infrarenal inferior vena cava. The pump was advanced until the tip of the cannula was positioned at the main pulmonary artery, using balloon catheter guidance under fluoroscopy. RV assistance was evaluated by pressure tracing, and aortic flow (AF) measured by electromagnetic flowmeter under 1) induced pulmonary stenosis (PS), and 2) electrically induced ventricular fibrillation (VF) in combination with left heart assist. Under PS, right atrial pressure decreased from 11 to 2 mmHg and AF increased from 1.0 to 4.1 l/min after initiation of the pump. Under VF, AF and aortic pressure were 2.6 l/min and 78 mmHg, respectively, with left ventricular assist. After initiation of the pump, they increased to 4.0 l/min and 98 mmHg, respectively. In chronic experiments using three adults goats for up to 48 hr, levels of plasma hemoglobin and platelet counts were maintained within an acceptable range. There was no prominent damage to the hearts. These data suggest that an axial flow pump introduced by an intravenous approach without thoracotomy is feasible and provides sufficient right heart assist.

Animals↗

Development of an electrohydraulic total artificial heart at the National Cardiovascular Center, Osaka, Japan.

The authors have been developing an electrohydraulic total artificial heart with a basic concept placing the blood pumps and an electrohydraulic energy converter separately, in the thorax and the abdominal region, respectively, to minimize anatomic constraints. Major problems of the system were a high energy consumption of 56 W at 6 L/min output and an insufficient maximum output of 6.7 L/min. The energy converter was redesigned to overcome these problems. A three phase, 4 pole brushless DC motor, which has maximum efficiency of 79% at a motor rotation of 2500 rpm with a load of 0.1 Nm, was developed for the new energy converter. Flow-channel design of the regenerative oil pump was optimized, which resulted in increasing the maximum flow rate at one directional motor rotation from 18 to 29 L/min. In vitro performance of the electrohydraulic total artificial heart was evaluated in a mock circulation with physiologic pressure conditions. Maximum output was increased to 10.7 L/min at a pump rate of 120 bpm and energy consumption of the motor at 6 L/min output was reduced to 18 W. Based upon these favorable results, the system is now being assembled for chronic animal implantation.

Animals↗

Heat generation and hemolysis at the shaft seal in centrifugal blood pumps.

The heat and hemolysis around a shaft seal were investigated. Materials were original pumps (Nikkiso HMS-15:N-original, and 3M Delphin:D-original), vane-removed pumps (Nvane(-), Dvane(-)), and a small chamber with a shaft coiled by nichrome wire (mock pump). The original pumps were driven at 500 mmHg and 5 L/min, and vane-removed pumps were driven at the same rotation number. An electrical powers of 0, 0.5, 2, and 10 W was supplied to the mock pumps. In vitro hemolytic testing showed that hemolytic indices were 0.027 g/100 L in N-original, 0.013 in Nvane(-), 0.061 in D-original, and 0.012 in Dvane(-). Measurement of heat with a thermally insulated water chamber showed total heat within the pump of 8.62 and 10.85 W, and heat at the shaft seal of 0.87 and 0.62 W in the Nikkiso and Delphin pumps, respectively. Hemolysis and heat generation of mock pumps remained low. The results indicate that the heat generated around the shaft seal was minimal. Hemolysis at the shaft-seal was considerable but not major. Local heat did not affect hemolysis. It was concluded that the shaft-seal affected hemolysis, not by local heat but friction itself.

Animals↗

Development and in vivo evaluation of an implantable left ventricular assist system with an impedance based monitoring and control system.

We have developed an implantable pneumatically driven diaphragm left ventricular assist system (LVAS) for small adults, and an electric impedance based monitoring and control system (Z system). In this Z system, measurement of electric impedance of the blood chamber is performed by charging an alternating current with a constant amplitude between two metal connectors without compromising anti-thrombogenicity. Automatic calibration was performed periodically by measuring trough values of impedance in the blood chamber for several beats while the blood pump was in a full-fill state under preset driving conditions. For precise control of the fill-to-empty (F/E) drive, an automatic trigger level adjustment method was developed. This method is an automatic searching algorithm that identifies the volume change of the last ejection or filling by the Z system and settles the next trigger level to maintain a definite stroke volume. In chronic in vivo evaluation, this LVAS was used in 13 adult goats. The pump was installed between the LV apex and the descending aorta and was placed in the abdominal wall. Pump output ranged from 2.5 to 5.8 L/min, and the Z system provided good monitoring. The F/E drive was achieved satisfactorily by this Z system. The physical condition of the goats was excellent for as long as 19 weeks. Hematologic, hepatic, and renal functions were within the normal range, and no prominent thromboembolic symptoms were observed. A new mobile control drive unit with this Z system is being developed. We conclude that this LVAS with the Z system is promising for long-term use in a clinical setting.

Adult↗

Development of an intravenous axial flow pump for temporary right heart assist.

In clinical settings, quick application systems with easy access for circulatory support are desired. For left heart assist, an intraarterial axial flow pump (Hemopump) has been developed and applied to clinical cases. However, no simple way has been proposed for right heart assist. We have developed an intravenous axial flow pump for temporary right heart assist and have reported its hemodynamic effect. In this study, in vivo evaluation of this system was performed. The pump system consists of an outflow cannula, an impeller that was newly developed for intravenous use, and a driving system for the Hemopump. A prototype pump demonstrated 3.2 L/min of maximal flow at a pressure differential against 40 mmHg at a pump speed of 28,000 rpm in mock circulation. Application to goats is as follows. A 14 mm low porosity graft was anastomosed to the infrarenal inferior vena cava (IVC). The pump system was inserted into the IVC through the graft and advanced to the right heart using balloon catheter guidance under fluoroscopy, and the tip of the cannula of the pump was positioned at the main pulmonary artery. In acute experiments, this system provided effective right heart assist under induced pulmonary stenosis and induced biventricular failure with left ventricular assist. Chronic animal experiments were performed for as long as 4 hr using adult goats weighing 51-54 kg. There were no difficulties in pump insertion. In one goat, the drive shaft was broken because of kinking of the shaft inside the body, caused by failure in securing the pump. Levels of platelet counts and plasma hemoglobin were acceptable, and there was no prominent damage to heart tissues. In conclusion, an intravenous axial flow pump introduced through a peripheral vein is practicable for temporary right heart assist.

Animals↗

Improvement in antithrombogenicity in a centrifugal pump with self wash-out structure for long-term use.

Antithrombogenicity in the initial (NCVC-1) centrifugal pump (CP) developed at our institute is provided by a central balancing hole in an impeller that promotes self wash-out blood flow (Sf) around the impeller. The current CP (NCVC-2) was ameliorated to obtain better antithrombogenicity, where the balancing hole diameter was widened to improve Sf velocity (Vsf), and the edge of a thrust bearing (TB) was rounded to minimize flow separation. Effects of the modifications were assessed in in vitro and in vivo studies. The Vsf of the NCVC-1 and the NCVC-2 evaluated by Doppler velocimeter were 12.8 and 22.1 cm/sec, respectively. Flow around the TB visualized by a light cutting method confirmed less flow stagnation in the NCVC-2. In vivo antithrombogenicity of the CPs was investigated in three goats. A pulsatile VAD (P-VAD) was installed paracorporeally between the left atrium and the aorta. After 3 weeks, the P-VAD was exchanged for the NCVC-2 and the NCVC-1 in sequence. Each CP was driven for 1 week and disassembled. No anticoagulation was used, except for heparin injection at pump exchange. Thrombus at the TB was found in the two NCVC-1s, and two little thrombi were on the impeller of another NCVC-1, whereas a thrombus smaller than 1 mm3 at the TB was noted in one NCVC-2. These results indicate that the NCVC-2 has better antithrombogenicity and Sf around the impeller and the TB.

Animals↗

Acute phase responses of vasoactive hormones to non pulsatile systemic circulation.

Acute phase responses of vasoactive hormones to the rapid conversion of a systemic flow pattern from pulsatile or non pulsatile mode to the reverse were assessed in 20 goats weighing 45-69 kg. A total left heart bypass was instituted under general anesthesia, with pulsatile and non pulsatile pumps interposed in the circuit in parallel, and the systemic flow mode was rapidly and bidirectionally converted from the pulsatile mode or non pulsatile mode to the reverse. Vasoactive hormone levels and hemodynamics were evaluated before and after 5 min of conversion. No significant difference was observed between the modes either in blood flow or systemic vascular resistance, while the mean aortic pressure was significantly higher in the non pulsatile mode than the pulsatile mode (106.7 +/- 2.4 versus 99.9 +/- 3.5 mmHg). Among various vasoactive hormone levels evaluated, only norepinephrine showed a significant difference between the modes, where concentration in the non pulsatile mode was significantly higher than the pulsatile mode (391.0 +/- 60.7 versus 309.4 +/- 42.5 pg/ml). No correlation was found between the absolute values of mean aortic pressure and norepinephrine level, whereas a significant reciprocal correlation was detected between the magnitude of inter-mode differences in these two parameters. In conclusion, a non pulsatile systemic circulation does not exert significant influence on vasoactive hormone levels, except for slight increase in norepinephrine with a reciprocally correlated increase in mean aortic pressure. It is deduced that activity of the sympathetic nervous system represented by norepinephrine level is higher in the non pulsatile mode than the pulsatile mode, and the baroreceptor reflex functions in an acute phase after flow mode conversion.

Acute-Phase Reaction↗

How does the sympathetic nervous system behave during non pulsatile circulation?

Non pulsatile circulation is commonly applied to clinical cardiopulmonary bypass or circulatory assist. However, influences of non pulsatile circulation on sympathetic nerve activity, which plays an important role in circulatory control, have not been elucidated. In this study the renal sympathetic nerve activity (RSNA) was recorded for the first time in goats, whose heart rate and size are similar to humans', and the difference during pulsatile and non pulsatile circulation was evaluated. Total left heart bypass was instituted in eight adult goats under general anesthesia. A pneumatic pulsatile pump and a centrifugal non pulsatile pump were incorporated in parallel so that pulsatile circulation and non pulsatile circulation could be instantly converted to the other. The pumping rate was set at 90/min regardless of the native heart rate during pulsatile circulation and the mean aortic pressure was maintained constant at the conversion of circulatory mode. The original signals of RSNA were integrated and defined as the mean RSNA. The mean RSNA and the mean aortic pressure were averaged every 30 sec and quantified during pulsatile circulation and non pulsatile circulation. The pulse synchronized burst of RSNA during pulsatile circulation immediately disappeared and the mean RSNA significantly increased up to 120% of pre depulsation level after changing the circulatory mode to non pulsatile circulation. Reverse conversion of circulatory mode from non pulsatile circulation to pulsatile circulation decreased the mean RSNA to 79%. The results suggest that vasotonus may be affected in its periodicity as well as its quantity by the loss of pulsation during the initial phase after depulsation.

Animals↗

Long-term cardiopulmonary support with a composite artificial heart-lung system.

A novel cardiopulmonary support (CPS) system as a long-term total substitute for the natural heart and lung was designed and evaluated. The CPS system is composed of a ventricular assist device (VAD) and a newly developed compact artificial lung (AL). The pneumatic VAD was originally developed in the authors' institute and has proven durable and antithrombogenic in over 120 clinical uses. The AL, with 1.2 m2 membrane surface area and 140 ml priming volume, consists of a special gas exchange membrane where not only are micropores blind-ended to prevent serum leakage, but the blood contacting surface is treated with heparin binding to ease systemic anticoagulation. Chronic animal experiments of total CPS were carried out in three goats weighing from 28 to 36 kg. Venoarterial bypass was instituted with the CPS system in which all venous blood was drawn from both the right atrium and ventricle and returned to the aorta. No systemic anticoagulation was conducted except for heparin added fluid infusion from pressure lines. One animal survived for 2 weeks without any device related problems until electively euthanized. Blood flow rate ranged between 3.2 to 4.5 L/min, O2 transfer between 120 to 220 ml/min, and CO2 removal between 60 to 210 ml/min. No substantial changes were found in platelet count or other coagulation factors. These results indicate that the system has the ability to be used for long-term CPS, such as a bridge to lung or heart-lung transplantation.

Animals↗

Power of the fatigue resistant in situ latissimus dorsi muscle.

To evaluate the in situ latissimus dorsi muscle as an actuator for circulatory assistance, 1) muscle power was analyzed in animal experiments, and 2) muscle weight was measured in human cadavers. Three adult goats underwent 12 week preconditioning. The insertion of the latissimus dorsi muscle was then connected to a spring and a tension transducer in series. The stroke length was measured with a photosensor without power loss. With contraction of muscles under various loads, tension-length relationships at end contraction and end relaxation were obtained and the maximum area of a square drawn within both lines was assumed to be maximum external power. Good fatigue resistance and the highest maximum external power of 3.16 Watts/kg at 120 min was derived from preconditioned latissimus dorsi muscle in burst frequency of 50 Hz. Muscle weight in 42 human cadavers was negatively correlated with age (r = 0.56) and was expected to be 221.6 g in patients aged 45 years. According to these data, the power of a human preconditioned latissimus dorsi muscle was estimated as 0.7 Watts. It was concluded the power of in situ preconditioned latissimus dorsi muscles was appropriate for right heart assistance or counterpulsation for left heart assist.

Aged↗

An approach to reducing hemolysis in an axial-flow blood pump.

In an attempt to decrease hemolysis caused by an axial-flow blood pump, we studied whether specific speed (Ns) at a design point (determined by flow in m3/min, pump head in m, and pump speeds in rpm), should be kept within the existing engineering standard range (1000 < Ns < 2500) or whether pump speed should be reduced to a minimum (Ns < 1000). Four pumps (A: 14,000 rpm, B: 18,000 rpm, C: 22,000 rpm, and D: 26,000 rpm), each with an impeller 11.8 mm in diameter, were designed to accommodate a flow rate of 5 L/min and a pressure head of 100 mmHg. At this design point, the Ns of each pump was calculated as A:758, B:974, C:1191, and D:1407. Pump performance was observed, and the total efficiency of each pump was calculated. The hemolysis index (HI) was calculated after simultaneous testing in duplicate of all four pumps using fresh goat blood (anticoagulated with citrate-dextrose solution) in a closed mock-loop circuit. Total efficiency of each pump was calculated as A:49%, B:50%, C:45%, and D:22%. In the first hemolytic test, HIs were measured as A:0.066, B:0.18, and C:0.13; a water seal failed in pump D. In the second test, HIs were B:0.077, C:0.0499, and D:0.12; a bearing failed in pump A. It is concluded that a lower level of hemolysis is associated with a pump speed in the minimum range at the design point, even though Ns is outside the standard range.

Animals↗

Set-up, improvement, and evaluation of an electrohydraulic total artificial heart with a separately placed energy converter.

The authors have been developing an electrohydraulic total artificial heart (TAH) system with a separately placed electrohydraulic energy converter to minimize anatomic constraints in the pericardial space. Improvements to the system and current status of the development are reported. The energy converter was miniaturized to improve implantability, and its thickness was reduced to 54 mm. System efficiency was increased by suppressing rush current at the time of motor reversal. Maximum cardiac output of the TAH system was 9 L/min, and maximum system efficiency increased to 10%. The blood pump system was implanted easily in the body of a 57 kg calf, and no significant temperature rise on the energy converter surface was observed. As the next step, main components were integrated into a total system. The transcutaneous energy transfer system could supply power to the TAH without a decline in pump performance, and the internal battery could support the system at 6.5 L/min of cardiac output for 1 hour without a decrease in cardiac output. The authors consider the TAH system with a separately placed energy converter the most promising approach to development of a TAH for smaller sized patients.

Animals↗

Development of a precise controller for an electrohydraulic total artificial heart. Improvement of the motor's dynamic response.

In an electrohydraulic total artificial heart developed at the National Cardiovascular Center (Osaka, Japan), two blood pumps are pushed alternatively by means of the bidirectional motion of a brushless DC motor for pump systole and diastole. Improvement in the dynamic response of the motor is very important to obtain better pump performance; this was accomplished by using power electronic simulation. For the motor to have the desired dynamic response, it must be commutated properly and the damping ratio (zeta), which represents transient characteristics of the motor, must lie between 0.4 and 0.8. Consequently, all satisfactory specifications with respect to power consumption must be obtained. Based on the simulated results, the design criteria were determined and the precise controller designed to reduce torque ripple and motor vibration, and determine motor stop time at every direction change. In in vitro tests, evaluation of the controller and dynamic response of the motor was justified in terms of zeta, power consumption, and motor stop time. The results indicated that the power consumption of the controller and the input power of the motor were decreased by 1.2 and 2.5 W at zeta = 0.6, respectively, compared to the previous system. An acceptable dynamic response of the motor, necessary for the reduction of torque ripple and motor vibration, was obtained between zeta = 0.5 and zeta = 0.7, with an increase in system efficiency from 10% to 12%. The motor stop time required for stable motor reoperation was determined to be over 10 msec, for a savings in power consumption of approximately 1.5 W. Therefore, the improved dynamic response of the motor can contribute to the stability and reliability of the pump.

Biomedical Engineering↗