Treatment of acute myocardial infarction with cardiogenic shock using left ventricular assist device.

We have treated ten cardiogenic shock patients after acute myocardial infarction (AMI) with a left ventricular assist device (LVAD). These patients were later divided into three groups: the first group with ventricular septal perforation, the second with aorto-coronary bypass grafting (ACBG) before LVAD implantation and the third group without ACBG. LVAD maintained the systemic circulation in each group, and cardiac function recovered enough to remove LVAD in 70% of the total patients. Two of three patients in the first group were discharged from hospital. Two weaned cases in the second group died of multiple organ failure and one was discharged, and hemorrhagic necrosis was seen in the bypassed area of the myocardium. One patient of the third group could not be weaned from LVAD because of respiratory failure though his heart function began to recover. Another case in the third group underwent bypass grafting after removal of LVAD. However ACBG surgery should be done very carefully because a patient in shock is occasionally intolerant to major surgery. In all groups, the major cause of death was multiple organ failure which was probably caused by the prolonged low output condition prior to LVAD application. In the light of this experience, it appears that LVAD should be applied before irreversible damage occurs to major organs, including the heart itself. To ensure the timely application of LVAD, some way must be found to introduce systematic application of LVAD into the normal course of AMI treatment.

Aged↗

Percutaneous access devices in calves receiving an artificial heart.

Vegetative endocarditis and thromboembolism are the two leading pathologic findings and causes of death in calves receiving total artificial hearts (TAH). Percutaneous access devices (PAD) for the pneumatic drive lines often become infected and may serve as the nidus of infection of the vegetative lesions. Observations of 80 calves living with TAHs revealed that most infections began at the dorsal surface of the PAD. Chronic skin ulceration or acute, traumatic avulsion can result in PAD separation from the skin and bacterial implantation. Evaluation of 58 necropsy specimens from calves with TAHs demonstrated improper flange positioning in 76% of the PAD and gross infection in 57%. A new implantation technique and design of PAD have resulted in better flange position and less irritation at the skin/device interface. Necropsies of 11 animals with the new PAD have shown a reduction in superficial infections.

Animals↗

Use of a paracorporeal pneumatic ventricular assist device for postoperative cardiogenic shock in two children with complex cardiac lesions.

Pneumatic ventricular assist device (VAD) was utilized for cardiogenic shock after intracardiac operation in two children with complex cardiac anomalies based with single ventricle. In the first case (a 10-year-old), after a modified Fontan operation, VAD was placed between the functional left atrium and ascending aorta, serving as a "artificial single ventricle" with neither pumping chamber nor artificial support in the right side of the heart. The systemic circulation was maintained by keeping relatively high central venous pressure. In another child (a 3-year-old) who underwent repair of incompetent atrioventricular valve leaving intracardiac lesions, VAD was placed between the common atrium and ascending aorta, serving as a pump for both pulmonary and systemic circulation with regulation of pulmonary blood flow through an aortopulmonary Gore-Tex shunt. The circulatory assist with VAD was utilized for 5 and 6 days, respectively. Although weaning from the device was not feasible in both patients because of the pulmonary dysfunction, these experience showed the possible use of VAD for cardiogenic shock after surgery in patients with complex cardiac anomalies.

Assisted Circulation↗

Comparison of an implanted abdominal aortic counterpulsation device with the intraaortic balloon pump in a heart failure model.

The abdominal aortic counterpulsation device is a round pumping chamber with a valveless opening which is implanted retroperitoneally on the abdominal aorta. The Utah driver is connected to the device through an air conduit and is synchronized on the electrocardiographic signal to provide diastolic aortic augmentation. For comparison an intraaortic balloon was also driven by the Utah driver system. The abdominal aortic counterpulsation device (stroke volume = 30, 40 and 60 ml) and the intraaortic balloon pump (balloon volume = 20 ml) were tested in dogs with acute left ventricular failure. The abdominal aortic counterpulsation device was also tested in normal animals. In acute left ventricular failure the abdominal aortic counterpulsation device at a stroke volume of 30, 40 or 60 ml decreased left ventricular end-diastolic pressure by an average of 28.56 (p less than 0.001), 39.56 (p less than 0.001) and 44.14% (p less than 0.005), respectively; aortic end-diastolic pressure by 24.11 (p less than 0.001), 26.67 (p less than 0.001) and 19.57% (p less than 0.01); and aortic systolic pressure by 18.56 (p less than 0.002), 26.0 (p less than 0.001) and 22.43% (p less than 0.005). It increased cardiac index by 27.58 (p less than 0.02), 35.59 (p less than 0.005) and 43.42% (p less than 0.001) and it provided peak aortic diastolic augmentation of 64.5 (p less than 0.001), 69.78 (p less than 0.001) and 74.43% (p less than 0.001), respectively, above the control aortic end-diastolic pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Surgical technique and hemodynamic characteristics of partial cardiac replacement with an artificial left ventricle.

To evaluate a method of mechanical replacement of the left ventricle in patients with left ventricular failure, we used a single mechanical ventricle in experimental animals. Identical mechanical ventricles were placed in six Hereford calves to obtain data for partial replacement. Four of the animals were weaned from cardiopulmonary bypass, and the other two died because of kinked grafts and poor function of the right ventricle. The main problems occurring with the mechanical ventricle were postoperative bleeding and kinking of the grafts, both of which can be solved with improvements in the design of the device.

Journal Article↗

Effects of implantation on the mechanical properties of the polyurethane diaphragm of left ventricular assist devices.

Tensile properties of blood pump diaphragms made from a segmented polyether polyurethane (Toyobo TM5) were studied after implanting in goats for variable periods of time up to 72 days. The implantation decreased the tensile strength and ultimate elongation at break, while the elastic modulus increased very slightly. These changes in the strength and ductility were primarily caused by the contact of material with blood rather than by the mechanical fatigue of material. Mechanical stability was greatly improved by removing residual oligomers from the material by a refining procedure. The refined polyurethane has characteristics favourable for blood pump applications.

Animals↗

Design of pusher-plate-type left ventricular assist device based on mechanical analyses.

A permanently implantable left ventricular assist device (LVAD) pump of the pusher-plate type was designed based on mechanical analyses. A series of three different segmented polyether polyurethanes was utilized for the diaphragm, cannulae, and their blood-contacting surfaces, considering each material's characteristics. The span and thickness of the pump diaphragm were determined so as to minimize the stress developed by the bending and blood pressure forces. The inflow and outflow cannulae were designed using fundamental equations that describe the operation of a piston-type reciprocating pump. The pump diameter was determined considering the required flow for the average Japanese person. In vitro and in vivo experiments showed good pump performance, which satisfied the design specifications. No failure was observed in the designed diaphragm. The Hall effect sensor incorporated in the pump was very useful in monitoring the cardiac output of the pump.

Animals↗

Circulation control of experimental and clinical profound left ventricular failures by automatic left ventricular assist system.

It is desirable that circulation control of the patient using a left ventricular assist device (LVAD) should be achieved appropriately and safely. We have developed an automatic LVAD system, which can maintain the normal circulation irrespective of the severity of heart failure and can restore the failing heart by decreasing the bypass flow (BF) through the LVAD as the heart recovers. The main part of the control-drive unit is an automatic level control (ALC) system for left atrial pressure (LAP) and total flow (TF). Profound left ventricular failure (LVF) was made by complete interception of blood supply to the extent of 50% (5 goats) and 70% (5 goats) of the LV free wall. The air-driven diaphragm-type LVAD was implanted between LA and aorta. At the beginning of LVAD pumping, BF tended to be very high to keep LAP at the preset level (0-5 mmHg) and to maintain TF at somewhat higher level (120-140 ml/kg/min). The recovering heart was able to decrease LAP gradually. Since the LAP was set at a certain level, the ALC of LAP decreased BF to maintain LAP at the preset level. During the recovering stage from LVF, preset level of LAP was gradually raised while checking the pulmonary function. When natural heart output exceeded 100 ml/kg/min, LVAD was removed. The 50% LVF group recovered between 17 hours and 3 days, and 70% LVF group between 6th and 16th postoperative day. This LVAD system was then applied to the postoperative profound LVF in a MVR patient whose entire circulation was maintained normal during 14 day pumping. The failed heart gradually recovered and the pump was successfully removed. We consider that the decompression of LV will prevent overextension of impaired myocardium and simultaneously accelerate the solid scar formation. And gradual increase of LV work will promote the compensation ability of the residual myocardium. Continuous LVAD assistance can therefore earn time for the impaired myocardium to recover while maintaining normal circulation.

Adult↗