Search PubMed⌕ Search

Biomedical subjects

Y Tadir

Publications and source records attributed to Y Tadir.

At least 37 records · Page 2Linked to original sources

Comparison of continuous versus pulsed CO2 and Nd:YAG laser-induced pulmonary parenchymal lung injury in a rabbit model.

BACKGROUND AND OBJECTIVE: Laser techniques have recently been described for treatment of patients with emphysema and bullous lung disease. Laser exposure of the pulmonary parenchyma during these procedures is complicated by laser-induced lung injury with substantial associated morbidity. Animal investigations are needed to develop methods that reduce lung injury. We hypothesized that the depth of injury could be reduced by pulsing laser exposures, with the goal of limiting thermal effects to more superficial tissue levels. In this study, we compared acute and chronic histologic injury resulting from pulsed- versus continuous-mode CO2 and Nd:YAG laser pulmonary parenchymal exposures in rabbits. STUDY DESIGN/MATERIALS AND METHODS: A total of 40 New Zealand White (NZW) rabbits underwent thoracotomy followed by exposure with CO2 laser (n = 10 continuous vs. n = 10 pulsed at 250 Hz with duty cycle 0.15 ms) or ND:YAG laser (n = 10 continuous vs. n = 10 pulsed at 10 Hz with duty cycle 0.10 sec) to the visceral pleural surface using 1 minute of laser exposure (5 watts, defocused to 70 W/cm2 power density) to the exposed lung surface. Rabbits were sacrificed at 4 and 21 days post-injury, and lungs were examined histologically. RESULTS: CO2 and Nd:YAG laser treatment resulted in substantial pulmonary parenchymal injury. While CO2 laser-induced damage was distinct from Nd:YAG histologically, pulsed-mode laser exposures did not reduce lung injury for either laser. Acute edema occurred to depths of 1180 +/- 338 microns for continuous-mode CO2 laser exposures compared to 1,340 +/- 430 microns in pulsed mode (p = .77). For Nd:YAG laser exposure, acute edema depth was 750 +/- 748 microns continuous versus 1120 +/- 367 microns pulsed mode (p = .65). Chronic lung fibrosis depth was 450 +/- 164 microns for CO2 continuous mode compared to 575 +/- 170 microns in pulsed mode (p = .61). Lung fibrosis depth for Nd:YAG was 550 +/- 96 microns, continuous versus 484 +/- 180 microns pulsed mode (p = .76). CONCLUSION: The similarity in injury between pulsed- and continuous-mode exposures suggests that thermal relaxation times are long relative to the selected pulse frequencies in intact living rabbit lungs. Alternatively, brief high-energy pulsations may increase focal temperatures with a tendency to increase injury depth relative to the penetration of the laser light. Thus, pulsed laser modes in these settings appear to be ineffective in reducing laser-induced lung injury in clinical settings.

Animals↗

Viscosity and refractive index of follicular fluid in relation to in vitro fertilization.

PURPOSE: To set the standard values of follicular fluid viscosity and refractive index, and to investigate a possible relationship between these physiological parameters and the outcome of in vitro fertilization treatment. DESIGN AND RESULTS: 128 samples of follicular fluid were collected from 40 in vitro fertilization patients. Viscosity determinations (centipoise; mean +/- SD) for shear rates of 23, 46, 115, and 230 were 2.04 +/- 0.86, 1.84 +/- 0.49, 1.48 +/- 0.27, and 1.38 +/- 0.22, respectively. The average (+/- SD) refractive index was 1.030 +/- 0.002. There was no significant difference between the values of thawed frozen fluids and fresh samples of the same specimens. The data showed no correlation between follicular fluid viscosity or refractive index and the presence of oocytes, their maturation grade or their fertilizing capacity. CONCLUSIONS: For the first time, values of the viscosity and refractive index of follicular fluid obtained during in vitro fertilization have been determined. However, these preliminary results did not reveal any relationship between the physiological parameters examined and the outcome of in vitro fertilization treatment.

Female↗

Selective photosensitizer localization in the human endometrium after intrauterine application of 5-aminolevulinic acid.

OBJECTIVE: Our purpose was twofold: to determine the distribution of the endogenous photosensitizer protoporphyrin IX in the uterus and to ascertain the time interval leading to maximal endometrial fluorescence after intrauterine instillation of 5-aminolevulinic acid. STUDY DESIGN: One milliliter of a 400 mg/ml 5-aminolevulinic acid-Hyskon solution was instilled into the uterine cavity of 27 women before hysterectomy. On frozen sections of uterine samples 5-aminolevulinic acid-induced fluorescence was measured with fluorescence microscopy. RESULTS: 5-Aminolevulinic acid-induced fluorescence could first be detected in the superficial endometrial glands 75 minutes after drug injection. In the endometrial gland stumps fluorescence intensity peaked 4 to 8 hours after 5-aminolevulinic acid instillation and was > 48 times higher than in the underlying myometrium. CONCLUSIONS: Fluorescence in the endometrial glands suggests that selective photodynamic destruction of the endometrium may be possible 4 to 8 hours after intrauterine 5-aminolevulinic acid instillation.

Aminolevulinic Acid↗

Structural and functional effects of endometrial photodynamic therapy in a rat model.

OBJECTIVE: Our purpose was to determine the optical dose required for irreversible endometrial destruction and prevention of implantation by photodynamic therapy with topical 5-aminolevulinic acid. STUDY DESIGN: Three hours after drug application 74 female Sprague-Dawley rats received varying doses of 630 nm of light delivered by an intrauterine cylindric diffusing fiber. RESULTS: A 64 J/cm2 in situ optical dose resulted in long-term irreversible endometrial destruction; 43 J/cm2 damaged endometrial stroma and myometrium but not glandular epithelium 1 day after photodynamic therapy. At this lower light dose endometrium regenerated to full thickness within 3 weeks; however, implantation sacs were significantly reduced. CONCLUSIONS: Photodynamic destruction of glandular epithelium accompanies irreversible endometrial ablation, whereas isolated stromal damage leads to reproductive impairment only. The optical dose required for endometrial ablation is approximately 1.5-fold higher than for reproductive impairment (functional damage) because of differential cell photosensitivity.

Aminolevulinic Acid↗

Selective photosensitizer distribution in vulvar condyloma acuminatum after topical application of 5-aminolevulinic acid.

OBJECTIVE: Our purpose was to determine the feasibility of selective photosensitization of vulvar condylomas by use of tropical application of 5-aminolevulinic acid. STUDY DESIGN: In vivo fluorescence was assessed and biopsy specimens of condylomas were taken for fluorescence microscopy in 24 patients at different times after application of 2.5% 5-aminolevulinic acid ointment or 20% 5-aminolevulinic acid cream. RESULTS: Both in vivo fluorescence imaging and fluorescence microscopy showed selective fluorescence of condylomas of the labia minora and vestibule only within short time intervals, because fluorescence of poorly keratinized normal epithelium was induced by both 5-aminolevulinic acid formulations. In non-hair-bearing skin, lesional fluorescence remained highly selective. Fluorescence microscopy showed that 90 minutes after drug application peak selectivity in epithelial lesional fluorescence was significantly higher with 2.5% 5-aminolevulinic acid ointment (4.5 +/- 0.9) than it was with 20% cream (2.1 +/- 0.2). CONCLUSION: Selective fluorescence of vulvar condyloma acuminatum can be induced by nonselective topical 5-aminolevulinic acid application. Studies evaluating selective photodynamic destruction of condylomas are justified.

Administration, Topical↗

[Benzoporphyrin derivative mono acid for photodynamic therapy of the endometrium].

The aim was to study the impact of photodynamic therapy (PDT) on the endometrium after local intrauterine application of photosensitiser (Ps) and laser light without sensitising the skin. To our knowledge Benzoporphyrin Derivative Mono Acid (BPD) was used for the first time for this purpose in the rat model. The advantage of using BPD is the fact that light of 690 nm (maximum absorption) penetrates deeper into tissue and shows less absorption by haemoglobin. Low-light level tissue fluorescence imaging revealed a distinct positive endometrium-to-myometrium ratio within the first 12 hours. Relative fluorescence was highest in the endometrial glands and lowest in the myometrium. After 12 hours the intensity of fluorescence levelled off in all compartments and values of the glands approached close to those of the other layers. REPRODUCTIVE PERFORMANCE AFTER PDT: There was a significant difference in nidations (p < 0.03) in the treated left uterine horn as compared to the untreated right horn and the control animals (light/no drug and drug/no light). HISTOLOGICAL CHANGES: Following PDT a marked atrophy of the endometrial layer was observed in most animals leaving just a single cell epithelial layer covering the myometrium. SKIN PHOTOSENSITIVITY: None of the animals showed any alterations in the light treated skin area at any time. These promising results show that PDT of the endometrium is possible after topical application of the photosensitising drug and the laser light without provoking skin sensitivity.

Animals↗

A mathematical model for light dosimetry in photodynamic destruction of human endometrium.

We are involved in the development of photodynamic therapy (PDT) as a minimally invasive method for treating dysfunctional uterine bleeding, one of the primary clinical indications for hysterectomy. In this paper, we analyse light propagation through the uterus in order to specify the requirements for a light delivery system capable of effectively performing endometrial PDT. Our approach involves developing an analytical model based on diffusion theory to predict optical fluence rate distributions when cylindrical and spherical optical applicators are placed in the uterine cavity. We apply the results of our model calculations to estimate the thermal effects of optical irradiation and the effective photodynamic optical dose. Theoretical fluence rate calculations are compared to fluence rate measurements made in fresh, surgically removed human uteri. Our results show that a trifurcated cylindrical optical applicator inserted into the human uterus can provide a light dose that is sufficient to cause photodynamic destruction of the entire endometrium. When the optical power per unit length of each cylindrical applicator is 100 mW cm-1 (at 630 nm), a fluence rate of 40 mW cm-2 is delivered to the boundary layer between the endometrium and the myometrium (a depth of about 4-6 mm). The optical fluence delivered to the boundary layer after 20 min of exposure is 50 J cm-2, a level that is generally accepted to cause tissue damage throughout the endometrium in most patients.

Dose-Response Relationship, Radiation↗

Doppler grid surface scanning applications for pulmonary subsurface parenchymal perfusion assessment.

Subsurface perfusion to lung parenchyma underlying the pleura is difficult to assess in live ventilated animals. The purpose of this study was to assess applicability of a newly developed laser Doppler grid scanning imaging technology that measures perfusion of pleural subsurface lung regions in intact normal and abnormal animal lungs. Eighty-six Doppler grid perfusion measurements were performed in five New Zealand White Rabbits (3-5 kg); four with unilateral bullous lung disease, one normal control. Left upper lobe lung surface was exposed to 10 1-sec spot Nd:YAG exposures (70 W/cm2). One week following laser exposure, all rabbits underwent sequential bilateral open thoracotomy. Unaffected left lower lobes in these animals and all four lobes of a previously untreated rabbit were used as controls. Pleural subsurface perfusion measurements were recorded over a contiguous 900-pixel square surface grid using quantitative noncontact laser Doppler imaging during open thoracotomy procedures. Scans were obtained in a normal volume ventilation mode, at 30 cm of inspiratory hold airway pressure, and postinflation. A perfusion-pressure response curve was obtained in normal lung at 10-, 20-, and 30-cm static airway pressure. Post mortem measurements were used as 0 flow controls. Normal lung tissue was found to have relatively high pleural subsurface perfusion (1362 +/- 328 corrected units on a scale of 0-4095). Areas of atelectasis had decreased perfusion (659 +/- 512 U., 48.4 +/- 12.5% compared to normal lung, p < 0.02), but returned to normal levels after inflation of the lung (1253 +/- 363 U., p = 0.21 compared to normal). Pleural subsurface perfusion decreased uniformly and progressively as lung inflation pressure increased (p < 0.0001). Perfusion increased immediately to supranormal values following release of high inspiratory inflation pressure holds (1603 +/- 626 U., 117 +/- 18% compared to normal lung, p = 0.03). Bullae had markedly decreased perfusion (541 +/- 68 U.) that was not further reduced by increased inflation pressures. Noncontact laser Doppler grid perfusion imaging appears to provide a new tool for measuring pleural subsurface perfusion over a large area of lung surface in clinical experimental settings. Results are rapid, reproducible, and consistent. Sampling errors inherent in current point sampling Doppler flow techniques are reduced by the multiple contiguous measurements. We have used this technique to demonstrate inspiratory pressure-related reduction in pleural subsurface perfusion in normal lung, reversible decreased perfusion in atelectatic regions, and reduced perfusion in bullous and laser-treated lung regions.

Analysis of Variance↗

Effects of ultraviolet exposure and near infrared laser tweezers on human spermatozoa.

Photostress has to be considered during optical micromanipulation of gametes. Ultraviolet light, including low-energy UVA (32-400 nm) radiation, as well as high-intensity near infrared (NIR) laser radiation may induce cell damage. A total number of 580 light-exposed sperm cells were studied in single-cell photostress experiments. Low-power (1.5 mW, 5.3 W/cm2) UVA exposure with 365 nm radiation of a standard mercury microscopy lamp to human spermatozoa resulted within 109 +/- 30 s in paralysis and within 310 +/- 110 s in cell death. Cytotoxic effects during cell manipulation with laser microbeams were found to be partly based on non-linear excitation phenomena, in particular two-photon absorption by endogenous cell chromophores. Two-photon absorption will be more intense in the case of pulsed laser microradiation, but occur also during micromanipulation with highly focused continuous wave (cw) microbeams used as laser tweezers ('optical traps'). In particular, short-wavelength NIR traps < 800 nm induce UVA-like biological effects (oxidative stress). For example, sperm trapping with 760 nm microbeams resulted in UVA-like autofluorescence modifications, paralysis within 35 +/- 20 s and cell death within 65 +/- 20 s. In contrast, laser microbeams at 800-1064 nm may act as relatively safe micromanipulation tools. In most optical traps multifrequency cw lasers are employed. Radiation of these lasers can magnify cytotoxic effects. Therefore, single-frequency laser operation should be preferred. In general, laser assisted cell micromanipulation requires a new understanding of microbeam-cell interaction, including aspects of non-linear optics.

Cell Survival↗

Regeneration processes in rabbit endometrium: a photodynamic therapy model.

The origin and process of regeneration in rabbit endometrium was evaluated following photodynamic epithelial destruction using topically applied aminolevulinic acid (ALA). Selective destruction of endometrial epithelium was performed using photodynamic therapy (PDT). ALA was diluted to 200 mg/ml dextran 70 shortly prior to administration. A volume of 1.2 ml was injected into the left uterus. Intrauterine illumination (wavelength 630 nm, light dose 40-80 J/cm2) was performed 3 h after drug administration. Tissue morphology was evaluated by light and scanning electron microscopy 1, 3, 7 and 28 days post-treatment (three animals at each time-point). Regeneration of the endometrium following epithelial ablation by PDT was fully activated after 24 h and was completed after 72 h. Endometrial surface generation occurred by proliferation, originating primarily in deeper regions of the glands. Findings from our morphological follow-up study support the origin of endometrial regeneration being mainly from undifferentiated stem cells and residual glandular epithelium.

Aminolevulinic Acid↗

CO2 and Nd:YAG laser-induced pulmonary parenchymal lung injury in a rabbit model.

Laser exposure of the pulmonary parenchyma during treatment of emphysema and other clinical indications causes acute lung injury. Animal investigations are needed to understand and control laser-induced lung injury. We hypothesized that lung injury is deeper from Nd:YAG laser exposures than CO2 exposures because of deeper penetration of Nd:YAG wavelength light. We compared the temporal evolution of histologic injury in rabbits resulting from continuous mode shallow CO2 and Nd:YAG laser pulmonary parenchymal exposures applied in rabbits. Forty-six New Zealand white (NZW) rabbits underwent treatment with CO2 laser (n=18), Nd:YAG laser (n=18), or sham thoracotomy control (n=10) to the visceral pleural surface using 1 min of exposure (5 watts, defocused to 70 W/cm2 power density for both lasers). Animals were killed at 0, 4, 7, 21, and 49 d after exposure. Lung injury, similar to that seen clinically in humans, developed in all laser-treated animals. Injury progressed from ischemia and vascular congestion, to edema and necrosis, followed by pleural and parenchymal fibrosis. The acute injury was qualitatively distinct and slightly deeper in CO2 than Nd:YAG-treated animals (p<0.02) despite the shallower depth of penetration of the CO2 laser. These findings may imply that higher absorption coefficient for CO2 laser energy results in greater focal temperatures and injury in the areas of direct exposure, and suggest that Nd:YAG laser exposure at these settings may cause shallower injury than CO2 lasers in humans undergoing clinical treatment.

Absorption↗

Determination of motility forces of human spermatozoa using an 800 nm optical trap.

The measurement and calculation of trapping forces on ellipsoidal specimens, and the determination of intrinsic motility forces of human spermatozoa by employing an 800 nm optical trap ("laser tweezers"), are presented. ATP-driven motility forces were calculated from calibrated trapping forces generated during the interaction of an 800 nm laser beam with single sperm cells. Calibration was performed by moving optically trapped sperm heads through a laminar fluid and calculating viscous forces for an ellipsoidal cell shape. Sperm heads were obtained by microsurgically removing flagellum with a pulsed laser beam ("laser scissors"). A trapping efficiency of 0.12 +/- 0.02 and a mean intrinsic motility force of 44 +/- 20 pN were determined for motile spermatozoa from healthy donors.

Humans↗

Augmentation of low ovarian response to superovulation before in vitro fertilization following priming with contraceptive pills.

Poor ovarian response to superovulation treatment is observed in a certain group of patients, the so-called 'low responders'. Despite the evolution of sophisticated controlled ovarian hyperstimulation (COH) regimens prior to the in vitro fertilization (IVF), the ideal stimulation protocol for the low responder has yet to be formulated. The objective of this study was to assess the effect of oral contraceptive pills (OCP), administered before the initiation of superovulation, on ovarian response and IVF treatment results in patients with previous 'low response' to exogenous gonadotropin stimulation. The study group comprised 42 patients who had exhibited poor ovarian response to standard superovulation protocols in at least two previous consecutive treatment attempts. Contraceptive pills were administered for 28-42 days and were immediately followed by menotropin treatment. The study group (n=50 cycles) was compared with the control group consisting of previous cycles (n=88) of the same women. Significant differences were noted in peak estradiol levels (983 +/- 739 vs. 517 +/- 249 pg/ml; P <0.01, paired Student's t test) and number of pre-ovulatory follicles between the study and the control groups. Thirty-three of the cycles (66%) reached the stage of ovum pick-up, compared with 22 (25%) of the previous IVF cycles in these women. The mean number of oocytes retrieved was 6.1 +/- 3.0 and 2.4 +/- 1.3 in the study and control groups, respectively (P <0.01; paired Student's t test). Embryo transfer (ET) was performed in 62% of the treatment cycles and resulted in five clinical pregnancies (16.1% per ET). No pregnancies were recorded in the control group. This study demonstrates the beneficial effect of OCP given prior to IVF treatment, and provides an efficient treatment modality for women who consistently respond poorly to standard COH protocols.

Adult↗

Assisted hatching in mouse embryos using a noncontact Ho:YSGG laser system.

PURPOSE: A noncontact holmium:yttrium scandium gallium garnet (Ho:YSGG) laser system has been designed and tested for the micromanipulation of mammalian embryos. The purpose of this preliminary investigation was to determine the effectiveness of this laser for assisted hatching and evaluate its impact on embryo viability. The Ho:YSGG system, utilizing 250-microsecond pulses at a wavelength of 2.1 microns and 4 Hz, was used to remove a portion of the zona pellucida (ZP) of two- to four-cell FVB mouse embryos. RESULTS: In the first experiment there was no difference in blastocyst production or hatching rates following laser or conventional assisted hatching (LAH or AH, respectively) in contrast to control embryos cultured in a 5% CO2 humidified air incubator at 37 degrees C. In the second experiment a blastocyst antihatching culture model was employed and LAH-treated embryos were cultured in a serum-free HTF medium (HTF-o). Blastocyst formation was not influenced by LAH treatment and hatching was increased (P < 0.01) from 4 to 60% compared to HTF-o control group. CONCLUSIONS: These preliminary data demonstrate the utility and nontoxic properties of the Ho:YSGG laser system for quick and precise ZP drilling.

Animals↗

Photomedicine of the endometrium: experimental concepts.

Gynaecological photomedicine offers new diagnostic and therapeutic methods based on the interaction of light with the reproductive organs. One example is photodynamic therapy (PDT) in which photosensitizers are applied systemically or topically for selective endometrial ablation. Several studies describing the potential use of PDT for this application are reviewed. Basic experimental and clinical aspects of PDT, such as photosensitizer types, application modes, irradiation parameters, optical properties of tissues and photodegradation of photosensitizers are discussed.

Animals↗

Rat reproductive performance following photodynamic therapy with topically administered Photofrin.

A rat animal model was used for comparing the photodynamic efficacy of two formulations of topically administered Photofrin in the uterus: 0.7 mg/kg Photofrin and 0.7 mg/kg Photofrin + 4% Azone, a penetration-enhancing agent. Uterine structure and reproductive performance were evaluated following illumination with 80 J/cm2 of 630 nm light. Fluorescence microscopy was employed to determine drug localization in frozen uterine sections at various times after drug administration. Functionality studies demonstrated a significant reduction in the number of implantations per treated uterine horn compared to controls. The mean number of implantations decreased systematically on increasing the interval between Photofrin administration and light application. At 72 h, 0.88 +/- 0.52 gestational sacs per rat were recorded with Photofrin therapy, compared with 8.1 +/- 1.12 (P = 0.01) on the untreated side, indicating nearly complete loss of reproductive capability. Similar results were achieved after only 3 h treatment with Photofrin + Azone (0.38 +/- 0.26 sacs per rat versus 7.5 +/- 1.07 on the untreated side; P = 0.01). This indicates that the effect of Photofrin can be enhanced either by extending the drug incubation period from 3 to 72 h or by adding the penetration-enhancing drug Azone. Fluorescence pharmacokinetic studies suggest that both forms of topically administered Photofrin are diffusely distributed throughout the endometrium at virtually the same rate. However, Azone may enhance the selectivity of photodynamic therapy by facilitating drug targeting to critical endometrial structures.

Administration, Topical↗

Intrauterine light delivery for photodynamic therapy of the human endometrium.

Photodynamic therapy is currently being evaluated as a minimally invasive procedure for endometrial ablation not requiring anaesthesia. Light penetration depths at 630, 660 and 690 nm and the optimal configuration of intrauterine light-diffusing fibres were determined in 14 human uteri to assist in the design of a light intrauterine device. Post-menopausal ex-vivo uteri showed a significantly lower light penetration depth than pre-menopausal uteri. With a single central diffusing fibre inserted, the fluence rate measured in the uterine wall at the most remote point of the cavity decreased to 1.1 +/- 0.4% of that measured at closest proximity, whereas it decreased to only 40.0 +/- 9.0% with three fibres. Distension of the uterine cavity with 2 ml of an optically clear fluid increased the fluence rate at the fundus between the fibres at a depth of 2 mm by a factor of 4. We conclude that in normal-sized pre-menopausal uterine cavities, three diffusing fibres will deliver an optical dose above the photodynamic threshold level at a depth of 4 mm, even in the most remote areas, in < 30 min without causing thermal damage. For distorted and elongated cavities, either slight distension of the cavity or the insertion of a fourth diffusing fibre is required.

Adult↗

Heterotopic abdominal pregnancy following in-vitro fertilization/embryo transfer presenting as massive lower gastrointestinal bleeding.

We present a case that, as far as we know, is the first report of lower gastrointestinal haemorrhage as a complication of heterotopic pregnancy induced by artificial reproductive technology. The heterotopic abdominal pregnancy caused erosion of the intestinal wall and massive rectal bleeding, 8 weeks after in-vitro fertilization/embryo transfer. The source of the bleeding could not be identified despite comprehensive investigation including gastroscopy, ultrasonography, sigmoidoscopy, 99Tc (technetium) scanning and angiography. Tagged-erythrocyte isotope scanning revealed an abnormal concentration in the left lower quadrant, compatible with active bleeding in the area of the terminal ileum. Laparotomy disclosed a heterotopic abdominal pregnancy, causing erosion of the intestinal wall at this site. As assisted reproductive technologies become more and more common this rare complication of intestinal erosion should be kept in mind in case of lower gastrointestinal bleeding.

Abdomen↗