[Students practice of comprehensive nursing].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Y Ogushi.
Explore the source record for details and available documents.
Both transport delay (DELAY) and dynamic response (RESPONSE) of a mass spectrometer would theoretically result in considerable errors in the breath-by-breath calculation of VCO2 and VO2. However, curiously, the contribution of RESPONSE has been ignored. The purpose of this study is to quantify the error caused by RESPONSE. We found that RESPONSE of a mass spectrometer was regarded as a first-order response. We determined DELAY and time constant (T) of RESPONSE and compensated the on-line calculation for both DELAY and RESPONSE and for DELAY only. With T of 150 and 100 ms, deviations of VCO2 from the gas-collection method were 8 +/- 6 and 8 +/- 6 ml/min with compensation for both DELAY and RESPONSE, and 69 +/- 10 and 50 +/- 5 ml/min with compensation for DELAY only, respectively (mean +/- SD). Similar results were obtained with VO2. A computer simulation of error caused by RESPONSE disclosed that the error linearly increased with increasing T. We conclude that to be accurate within +/- 5% of the exact value, compensation should be made when T exceeds 25 ms.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A Laboratory Information System (LIS) has been developed and the main part of LIS is an on-line system with auto analysers. In April 1976, the Biochemistry Laboratory was computerized in Osaka Prefectural Habikino Hospital. This LIS uses a PDP 11/40 minicomputer system using MUMPS language. At present a Mycobacteria Tuberculosis Laboratory (MTL) is computerized using the same computer and MUMPS. In this laboratory, there is no auto analyser, so this computerization aims at saving on labour in paper work and increasing the reliability of test results. This paper shows that the computerization of MTL with no auto analyser can be effectively achieved using MUMPS.
This paper presents the basic consideration of global file design on MUMPS language. The major goal of global design is to reduce the number of disc accesses made over the long-term use of a file. To attain this goal, the procedure for finding the global file which minimizes the average number of disc blocks accessed to obtain a data node is proposed. Furthermore, the total number of blocks in use with file design are demonstrated by simple examples.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.