[Resuscitation in cardiopulmonary arrest in adults].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Y Louville.
Explore the source record for details and available documents.
Eleven anaesthesia ventilators were instrumentally tested under various conditions. They included: Excel and Modulus II Plus (Ohmeda); 710 and Servo anaesthesia circle 985 (Siemens); Jollytronic (Soxil) and Elsa (Engström); SA2 and Cicero (Dräger); ABT 4,300 (Kontron); Monnal A and the prototype Alys (Taema). The test circuit comprised a two compartment model lung, a pneumotachograph, a pressure gauge in the "airway". The volume was calculated as the integral of flow rate. Each machine was calibrated by the firms' technicians. Before each test, the pneumotachograph was calibrated using a 11 air syringe and the pressure gauge with a 5 cm water column. Each machine ventilated the model lung for 30 min before starting the tests. There were five tests: 1) reliability of the machine's spirometer, 2) reliability of the ventilation rate, 3) reliability of pressure measurements, 4) effect of increasing fresh gas flow on spirometry, 5) effect of increasing downstream resistances. In usual simulated ventilatory conditions, all the machines accurately delivered the setted ventilation and spirometric measurements were with minimal error only. Several ventilators (SA2, Excel, 710, Elsa, ABT 4,300) did not succeed in maintaining their performances when compliance was strongly decreased or resistance of the test lung notably increased. Resistance in the circuit during simulated spontaneous ventilation was < 3.6 cmH2O.l-1.s-1. Increasing fresh gas flow raised the minute volume delivered in six ventilators. It is concluded that, during extreme ventilatory conditions, the inspired volume must be adjusted so as to maintain the inspired tidal volume. However, ventilators which increase inspiratory time in response to an increased mechanical load cannot be adjusted by this way.
Non traumatic spinal hematomas are a rare pathology, anticoagulant treatments are one of their most frequent etiology. Therefore, the association of spinal anesthesia and a preventive treatment which has antithrombotic aim by the use of subcutaneous heparin (non fragmented or low molecular weight) is being discussed by many authors. It is lawful to associate spinal anesthesia with a soft dose of non fragmented subcutaneous heparin (Kakkar method) if the protocols are strictly respected. It is certainly possible to use low molecular weight subcutaneous heparin as well. However a slight decline in their use urges anyone to be very cautious.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The potency, amnesic, and postanesthetic analgesic effects of transcutaneous cranial electrical stimulation (TCES) were evaluated during N2O anesthesia in 120 unpremedicated patients, prior to urologic or general surgical operations. The patients were divided into six groups of 20 each with respect to what concentration of N2O in oxygen they were allowed to breathe (75, 62.5, and 50%), and whether they were or were not stimulated with TCES. Recordings of heart and respiratory rates, systolic arterial blood pressure, and minute ventilation were made prior to and after 20 min of N2O, and one minute later following application of a Kocker clamp to the upper inner thigh for one minute. The presence or absence of movement during the painful stimulus, memory of the painful stimulus, and postanesthetic pain at the clamp site (20 min after anesthesia) were also evaluated. Patients who received TCES had significantly lower incidences of movement, memory of the painful stimulus, and postanesthetic pain at the stimulation site at each N2O concentration than patients not getting TCES. TCES did not alter circulatory and respiratory dynamics prior to painful stimulation and prevented an increase in arterial blood pressure during painful stimulation in patients receiving 50% N2O. These data indicate that TCES significantly increases the analgesic potency of N2O and probably also the depth of anesthesia.
The influence of transcutaneous cranial electrical stimulation (TCES) on fentanyl requirements was evaluated in 50 patients undergoing urologic operations with pure neuroleptanesthesia (droperidol, diazepam, fentanyl, and air oxygen) with (group I) or without (group II) simultaneous TCES. All patients had silver electrodes (three) applied between the eyebrows and behind each mastoid process and attached to a 167-kHz current generator. Current was delivered only to group I. The wave form was a complex nonsinusoidal, nonsquare wave pattern which was applied intermittently in a 3-msec-on 10-msec-off sequence. All patients had anesthesia induced with droperidol (0.20 mg/kg IV), diazepam (0.2 mg/kg IV), and pancuronium (0.08 mg/kg IV), and, after tracheal intubation, had anesthesia maintained with fentanyl in 100-microgram intravenous increments every 3 minutes whenever and as long as systolic arterial blood pressure and/or heart rate were greater than 20% of control (preanesthetic induction) values. Fentanyl requirements averaged 6.1 +/- 0.5 and 7.9 +/- 0.4 microgram/kg/min for a mean total dosage of 9.0 +/- 0.9 and 12.5 +/- 0.8 microgram/kg for the entire operation in groups I and II, respectively. These differences between groups were statistically significant (p less than 0.05). The data demonstrate that TCES augments the analgesic effects of fentanyl and thus reduces fentanyl requirements during urologic operations with neuroleptanesthesia.
It is accepted that the laboratory and clinical so-called "transurethral resection syndrome" reflects passage into the body of a large fraction of the water used to perfuse the field of endoscopic resection. The major complete syndrome (dyspnoea, nausea, hypertension, raised central venous pressure, bradycardia then pulmonary oedema, cerebral oedema, cardiovascular shock and renal insufficiency) is rare: 1.5 per cent of cases of transurethral resection of the prostate in the literature, 0.6% in a series of the last 300 resections performed by the authors (2/300). Also was it not possible to hope for a complete physiological study of sufferers from this complication. Nevertheless, it may be considered that all transurethral resections of the prostate may be associated with similar movements of water to a minimal extent. In order to attempt to demonstrate this, the authors studied in a series of 19 patients pre- and postoperative blood volumes by a radio-immunological technique using pre- and postoperative serum albumin haematocrits. In this short series, patients who had undergone a short endoscopic resection (35 minutes on average) of a small adenoma (13 grams on average) with a mean irrigation of 10 litres of water rendered isotonic by the addition of glycocolle, without any transfusion or infusion being necessary during the course of the resection, the conclusion was simple: no variation in blood volume was demonstrated. Is the physiopathological hypothesis advanced to explain this phenomenon false? And is the problem in fact one of peroperative septicaemia?
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Sixty-five infants were submitted to complete repairment of a congenital cardiopathy under profound hypothermia and ECC. Description of the preparation of the young surgical patient, of the anesthesia, of the technique of ECC. The overall mortality was 35.5 p. 100. The hypothermia induced by ECC, does not introduce any supplementary risks as long as strict technical rules are respected.