Search PubMed⌕ Search

Biomedical subjects

Y Kotsuka

Publications and source records attributed to Y Kotsuka.

At least 37 records · Page 2Linked to original sources

Three-dimensional computed tomography for reoperative minimally invasive coronary artery bypass.

We have been using three-dimensional computed tomography (3-D CT) in reoperative coronary artery bypass grafting performed by using a minimally invasive approach. Preoperative 3-D CT scanning can provide beneficial anatomical information about old patent grafts as well as the internal thoracic artery. Thus a mini-thoracotomy can be created at an optimal site, leaving the old graft untouched, and the length of the harvested internal thoracic artery, necessary for the bypass, can be assessed using this new modality.

Coronary Artery Bypass↗

Minimally invasive limited pericardiectomy: the hybrid approach.

This communication describes our clinical experience with the hybrid method, a video-assisted anterior minithoracotomy approach developed for minimally invasive limited pericardiectomy to treat 8 patients with massive pericardial effusion. The average operating time was 37.2 minutes, and there was no procedure-related morbidity or mortality. The mean follow-up period was 5.6 months, and there have been no recurrences. The hybrid approach can be accomplished irrespective of pleural adhesions. It eliminates the need for hemipulmonary collapse, making it more advantageous than the totally port-access thoracoscopic approach.

Aged↗

Right heart mini-pump bypass for coronary artery bypass grafting: experimental study.

BACKGROUND: Visualization of the left circumflex arteries during off-pump coronary artery bypass grafting (CABG) causes hemodynamic disturbance. We investigated whether right heart mini-pump bypass (RHB), using a centrifugal pump, improved the safety of this procedure by studying the influences of different heart displacement positions, the Trendelenburg maneuver and RHB on hemodynamics. METHOD: Hemodynamic parameters in eight mongrel dogs (15.5-20 kg) were continuously monitored at a fixed heart rate of 80 beats/min through a conventional median sternotomy. The posterior descending artery (PDA) and left circumflex artery (LCX) were exposed using an Octopus tissue stabilizer. After evaluating the influence of the Trendelenburg maneuver on hemodynamics, a heparin-coated centrifugal pump without an oxygenator was introduced and the impact of different pump flow volumes was investigated during RHB. RESULTS: LCX exposure caused significant decreases in aortic flow (to 35. 1+/-12.8%) and arterial mean pressure (to 66.1+/-9.3%) compared with baseline (P<0.001). In contrast to PDA exposure, values remained significantly decreased during the Trendelenburg maneuver. On the contrary, RHB significantly improved the hemodynamic impairments caused by both heart displacement procedures, especially LCX exposure, although 100% pump flow significantly increased left atrial pressure to 131.3+/-19.5% (P<0.01). CONCLUSION: Exposure of the LCX caused severe hemodynamic deterioration, which was not fully reversed by the Trendelenburg maneuver. In contrast, RHB significantly improved hemodynamics, and therefore this technique can be beneficial for CABG of LCX in the limited cases.

Animals↗

[Recent donation and clinical results of homograft tissue].

Between August 1995 and July 1999, we have experienced 14 donors for allografts (mean age: 39.8 +/- 15.8, M/F = 10/4, mean warm ischemic time: 359 minutes). Donated tissues were included 12 aortic valves and 12 pulmonary valves, respectively. Since February 1994, clinical diagnoses of 14 patients included 7 congenital heart disease, 5 infective heart disease, 1 artificial graft infection, and 1 thrombosed valve. There was no graft-transmitted disease. In congenital heart disease, 3 patients (HLHS: 1, Truncus: 1, TOF + PA: 1) died (early mortality, 42%) and 1 with TGA had residual conduit stenosis. However, in infective heart disease, all patients survived without recurrent infection and did not need reoperation (early mortality, 0%). Our clinical results of homograft implantation for infective heart disease were excellent, but more careful consideration will be needed for congenital heart disease in neonates and/or patients with poor preoperative condition.

Adolescent↗

Swinging motion of intimal flap through the aortic valve in acute aortic dissection.

The purpose of this article is to present a very rare case of Stanford type A acute aortic dissection featuring a swinging motion of the cylinder-shaped intimal flap through the aortic valve. The patient was a 62-year-old male suffering from severe cardiogenic shock. A transthoracic echocardiogram revealed aortic dissection and severe aortic regurgitation. A transesophageal echocardiogram demonstrated that the aortic dissection in the ascending aorta was circumferential and the proximal portion of the intimal flap was swinging through the aortic valve, ie., falling into the left ventricle during the diastolic phase and being ejected back into the ascending aorta during the systolic phase. An emergency graft replacement of the ascending aorta was performed. During ventricular fibrillation under total cardiopulmonary bypass, we performed cardiac massage to prevent myocardial ischemia, because blood flow from a heart lung machine inverted the intimal flap, which might have disturbed the coronary circulation. The patient's postoperative course was uneventful, and his postoperative echocardiogram revealed only a trace of regurgitant flow through the aortic valve. Back-and-forth movement of the cylinder-shaped intima requires coexistence of the following three conditions: severe aortic regurgitation, circumferential dissection, and complete transection of the intimal flap. We conclude that this movement of the intimal flap should be regarded as one of the most serious complications leading rapidly to cardiogenic shock. From a surgical point of view, it is most important to prevent myocardial ischemia during cardiopulmonary bypass especially in cases in which ventricular fibrillation has occurred. We describe the ways to prevent myocardial ischemia in this rare situation.

Acute Disease↗

Atrial ablation using an IRK-151 infrared coagulator in canine model.

BACKGROUND: A method of atrial ablation was developed with the aim of shortening the aortic cross-clamp time during MAZE surgery. The IRK-151 infrared coagulator (Infrarot-Kontaktkoagulator: MBB: Messerschmidt-Bolkow-Blohn, Germany) was employed. Our aim was to electrophysiologically confirm the efficacy of this device. METHODS: The MAZE-III procedure was performed in four mongrel dogs. Instead of a pulmonary vein-encircling incision, IRK-151 was applied several times to create a continuously overlapping circular lesion. After aortic declamping, the potentials of both atria were recorded using 18 bipolar electrodes implanted in the atrial wall. The recording conditions were: 1) sinus rhythm, 2) overdrive pacing from outside the encircling coagulation, and 3) overdrive pacing from inside the encircling coagulation. RESULTS: 1) There was no detectable potential within the pulmonary vein-encircling coagulation. 2) There was no conduction of paced atrial potential inside the encircling coagulation. 3) Only the area within the encircling coagulation was activated by the stimulus. Other parts of the atrium showed sinus rhythm simultaneously. CONCLUSIONS: The left atrium within the pulmonary vein-encircling coagulation was isolated electrophysiologically.

Animals↗

Management of severe acute pancreatitis with a somatostatin analog in a patient undergoing surgery for dissecting thoracic aneurysm: report of a case.

A patient who was admitted to our hospital to undergo surgery for a dissecting thoracic aneurysm suffered preoperatively from severe acute pancreatitis with pancreatic pseudocysts. Computerized tomography (CT) demonstrated the presence of new fluid collection around the cyst with the absence of pancreatic necrosis. He was given a somatostatin analog (sandostatin), which was effective in decreasing the abdominal symptoms, leukocyte counts, and the serum C-reactive/protein level. A CT scan revealed that the pancreatic pseudocyst and peripancreatic fluid collection had disappeared. Although somatostatin has been reported to be ineffective for acute pancreatitis with necrosis, pancreatitis without necrosis may regress after treatment with sandostatin. This is probably due to its suppressive effect on the exocrine function, thus resulting in a decrease of pancreatic juice infiltration.

Acute Disease↗

Intravalvular implantation technique for aortic valve replacement in aortitis syndrome.

BACKGROUND: Paravalvular leakage is one of the most serious complications of aortic valve replacement in patients with aortitis syndrome. The purpose of this study was to compare the effectiveness of the intravalvular implantation technique in preventing paravalvular leakage with that of the conventional technique. METHODS: Since 1982, 14 patients with aortic regurgitation caused by aortitis syndrome have undergone aortic valve replacement at our institute. An intravalvular implantation technique was applied in 7 of the 14 patients. The technique consists of suturing a prosthetic valve to the aortic annulus and sandwiching the leaflets between exogenous felt pledgets and the inflamed aortic annulus. RESULTS: Paravalvular leakage occurred in 3 of 7 patients in the conventionally treated group and in none of 7 in the intravalvular implantation group. CONCLUSIONS: The intravalvular implantation technique is effective in preventing paravalvular leakage in patients with aortitis syndrome.

Adult↗

Hemodynamic effects of carbon dioxide insufflation under single-lung ventilation during thoracoscopy.

BACKGROUND: The hemodynamic effects of carbon dioxide insufflation under single-lung ventilation were studied in 22 consecutive thoracoscopic harvests of the left internal mammary artery, which was used for minimally invasive coronary artery bypass grafting. METHODS: An electrocardiograph, arterial catheter, Swan-Ganz catheter, and transesophageal echocardiograph were used to monitor seven hemodynamic variables. Baseline data were obtained during ventilation of both lungs and the measurements were repeated after the left lung was collapsed and at 5 and 30 minutes after hemithorax insufflation with low-flow (2 to 3 L/minute) carbon dioxide gas was begun. The intrapleural pressure was maintained at 8 to 10 mm Hg. RESULTS: Thoracoscopic harvest of the internal mammary artery was completed in all cases with a mean insufflation time of 44+/-12 minutes. There were no significant changes in the mean arterial pressure, heart rate, cardiac index, and left ventricular ejection fraction throughout the procedure, whereas the central venous pressure, mean pulmonary arterial pressure, and pulmonary capillary wedge pressure (p < 0.05 for each variable) during insufflation. CONCLUSIONS: Low-flow carbon dioxide insufflation into the left hemithorax with an intrapleural pressure of 8 to 10 mm Hg under selective right-lung ventilation does not compromise the human heart with normal to moderately depressed function and can be an efficacious adjunct in specific thoracoscopic procedures.

Aged↗

Application of AdvaSeal for acute aortic dissection: experimental study.

BACKGROUND: In the surgical treatment of acute aortic dissection, intractable hemorrhage often occurs. We performed an animal study to test the hypothesis that a new sealant, AdvaSeal (Ethicon Inc, Johnson & Johnson Medical KK, Somerville, NJ), can close the false channel of aortic dissection. METHODS: Acute descending aortic dissection was created surgically in 12 mongrel dogs. In 7 of these (treated group), AdvaSeal was applied to the false cavity for reinforcing and fusing the dissected layers and also to the suture line. The other 5 dogs (control) were left untreated. Specimens were harvested 2 weeks after surgery. RESULTS: The sealant could be used in wet conditions. In the treated group, hemostasis was easily achieved during surgery. All false cavities were perfectly thrombosed, causing no deleterious effects related to the sealant. In the control group, all false lumina remained patent. CONCLUSIONS: The advantage of AdvaSeal was its effectiveness on wet tissue and its adhesiveness, allowing good hemostasis and closure of the false lumen. The sealant can be an easy and efficacious sealant in treatment for acute aortic dissection.

Acute Disease↗

Estimation of functional liver reserve in patients before cardiac surgery using antipyrine plasma clearance test.

BACKGROUND: Hyperbilirubinemia is not uncommon and is sometimes fatal after valvular surgery. One important cause of it is a poor functional liver reserve, however, conventional tests reflect hepatic blood flow and do not offer precise evaluation of the pure functional liver reserve. Antipyrine has particular pharmacological properties, and its plasma clearance represents quantitatively the functional capacity of the liver. In this study, we measured antipyrine plasma clearance in cardiac surgical patients and evaluated the feasibility of using this parameter as a predictor of the risk of postoperative hyperbilirubinemia. METHODS: The plasma clearance of antipyrine was measured preoperatively in 40 cardiac patients undergoing mitral and/or tricuspid valvular surgery and its relations with hemodynamics or postoperative course were studied. RESULTS: Antipyrine clearance in preoperative patients was 0.365+/-0.175 (mean +/- SD) ml/min/kg, lower than the normal range (0.405+/-0.04 ml/min/kg), and showed no correlation with cardiac index, while the plasma disappearance rate of indocyanine green depended on the cardiac index. The maximum postoperative total bilirubin level showed significant correlation with antipyrine clearance (r=-0.699); this correlation coefficient was greater than that with indocyanine green (-0.477). The correlation was more prominent in patients with cardiac dysfunction. Furthermore, antipyrine clearance showed significant predictability of the duration of ICU stay. CONCLUSIONS: Antipyrine clearance provides a precise estimate of functional liver reserve which is independent of hemodynamics and predicts the risk of postoperative hyperbilirubinemia in preoperative cardiac patients.

Adult↗

[Video-assisted MICABG for the patient with right mammary carcinoma--a case report].

A 69-year-old female with advanced right mammary carcinoma presented to us with diffuse stenosis of the proxymal left anterior descending artery (LAD). Right mastectomy had been suspended. The LAD was treated with minimally invasive CABG (MICABG) assisted with a thoracoscopic procedure. The left internal thoracic artery (LITA) was taken down through thoracoscopy from the upper margin of the 1st rib to the lower margin of the 5th rib using only the Harmonic Scalpel (Ethicon Endo-Surgery). Coronary anastomosis to the LAD was completed without cardiopulmonary bypass through a small thoracotomy on the anterior 4th intercostal space. The operation time was 4 h 30 min and the blood loss was 120 ml. Post operative course was uneventful. Doppler study and angiography demonstrated patent LITA to the LAD. Right mastectomy was achieved 29 days after MICABG. MICABG can be a veneficial alternative method for the patient with malignant disease, allowing quick convalescence and early cancer operation. Thoracoscopy allows for sufficient LITA harvest up to the 1st rib or higher with the Harmonic Scalpel.

Aged↗

Repair of ruptured anastomotic aneurysm: elephant trunk technique after endovascular covered stents.

Endovascular covered stents were successfully applied to temporarily halt hemoptysis and postpone surgical intervention in a 69-year-old man with a ruptured anastomotic false aneurysm of the distal aortic arch. Surgical graft implantation was performed successfully by the elephant trunk technique 14 days after the endovascular stent-grafting, at which time aspiration pneumonia had subsided.

Aged↗

Atrial ablation with an IRK-151 infrared coagulator.

BACKGROUND: The purpose of this study was to develop a method of atrial ablation. In the IRK-151 infrared coagulator, light from a tungsten-halogen lamp is focused into a quartz rod. The distal exit plane is connected to a tip made of sapphire to allow linear ablation. METHODS: Thirty-six lesions were created in 9 mongrel dogs. The beating ventricular myocardium was ablated from the epicardium. In each dog, 4 lesions were created by using the following durations of application: 3, 9, 15, and 21 seconds. After the ablation, the myocardium was fixed and stained. A linear lesion on the beating right atrial free wall was created. Before and after the ablation, epicardial plaque-electrode mapping was performed. Three months after ablation, remapping was performed. RESULTS: The ablated myocardium had well-demarcated necrosis without carbonization or vaporization. The maximum depth was 10.3 +/- 0.8 mm. The conducting pathway was blocked. The block, once made, continued for 3 months. CONCLUSIONS: The IRK-151 produces well-demarcated lesions that were deep enough for atrial ablation to block the conducting pathway.

Aluminum Silicates↗