Search PubMed⌕ Search

Biomedical subjects

Y Betsuin

Publications and source records attributed to Y Betsuin.

2 recordsLinked to original sources

Clinical application of the multifocal VEPs.

PURPOSE: To determine whether visual field defects can be detected by the multifocal VEP technique. METHODS: Multifocal VEPs were elicited by a pseudorandom binary m-sequence stimulus (VERIS II). The stimulus was a dartboard-like pattern of 61 sectors, and the luminance of each sector alternated between white and black. The stimulus area subtended approximately 25 degrees. Each recording was divided into 8 equal segments, and the total recording time was about 4 min. Multifocal VEPs were recorded from 25 normal subjects and six patients with visual field loss. The responses summed within 4 quadrants were used in the analysis and were compared with the visual fields obtained by perimetry. RESULTS: In six perimetrically-documented visual field defects, the responses summed over each quadrant of the field were reduced in the corresponding affected quadrants. In addition, recovery of the visual field loss following treatment was accompanied by a recovery of the responses. CONCLUSIONS: Multifocal VEPs summed within four quadrants can be used for an objective evaluation of the visual fields. The testing can be obtained in 4 min with no pain or discomfort to the patient.

Adult↗

[Two cases of digitalis toxicity with reversible and severe decrease of visual acuity].

BACKGROUND: We performed electrophysiologic tests on two patients with digitalis toxicity who first had photophobia and xanthopsia and revealed reversible reduced visual acuity and binocular central scotoma. CASES: The patients were a 72-year-old male and a 54-year-old male who had symptoms of digitalis toxicity. FINDINGS: The corrected visual acuity was severely decreased during digitalis toxicity, 0.02 oculus dexter (OD) and 0.1 oculus sinister (OS) in case 1 and 0.04 OD and 0.2 OS in case 2. But visual acuity recovered as the blood levels of digitalis decreased to the normal level and the corrected visual acuity was 0.7 OD and 0.8 OS in case 1 and 0.8 OD and 0.9 OS in case 2. We recorded 30 Hz-flicker electroretinogram (ERG), single flash ERG, photopic ERG, and scotopic ERG when digitalis blood levels were elevated and normal. Decreased amplitudes of 30 Hz-flicker ERG and photopic ERG suggested that photoreceptor function was disturbed at digitalis toxicity and cone dysfunction was more severely disturbed than rod dysfunction. CONCLUSION: 30 Hz-flicker ERG, as well as electrocardiogram and digitalis blood level, is a relatively convenient and useful measure of digitalis toxicity. It is necessary consiler toxicity when severe visual dysfunction is observed in patients with digitalis therapy.

Aged↗