Search PubMed⌕ Search

Biomedical subjects

Y Bashir

Publications and source records attributed to Y Bashir.

At least 37 records · Page 2Linked to original sources

Postcardiotomy syndrome following transvenous pacemaker insertion.

We describe a case of postcardiotomy syndrome following permanent pacemaker insertion. A 79-year-old woman presented with complete heart block. Following temporary pacing, a dual chamber permanent pacemaker was inserted. Two weeks later she developed fevers and malaise with an acute rise in inflammatory markers. After systemic infection had been carefully excluded, she was commenced on prednisolone with immediate benefit. Prednisolone was withdrawn over 2 months without recurrence of symptoms. Although the postcardiotomy syndrome is rare following transvenous pacemaker insertion it should be considered in the differential diagnosis of fevers and malaise after implantation.

Aged↗

Heart rate variability and its relation to ventricular arrhythmias in congestive heart failure.

BACKGROUND: It has been shown that heart rate variability is decreased in patients with congestive heart failure and that depressed heart rate variability is associated with a propensity to ventricular arrhythmias. Little is known, however, about heart rate variability in patients with both congestive heart failure and ventricular arrhythmias. METHODS: Spectral heart rate variability was analysed from 24 hour ambulatory electrocardiograms in 15 controls, 15 patients with non-sustained ventricular tachycardia associated with clinically normal hearts (NHVT group), and 40 patients with congestive heart failure (CHF group) secondary to either ischaemic heart disease (n = 15) or idiopathic dilated cardiomyopathy (n = 25). Of the 40 patients with congestive heart failure 15 had no appreciable ventricular arrhythmias (ventricular extrasystoles < 10 beats/h and no salvos) and formed the CHF-VA- group. Another 15 patients with congestive heart failure and non-sustained ventricular tachycardia formed the CHF-NSVT group. RESULTS: Heart rate variability was significantly lower in the CHF group than in controls (mean (SD) total frequency 23 (12) v 43 (13) ms; low frequency 12 (8) v 28 (9) ms; high frequency 8 (5) v 14 (7) ms; p < 0.001). The differences in heart rate variability between controls and the NHVT group, between ischaemic heart disease and dilated cardiomyopathy, and between the CHF-VA- and CHF-NSVT groups were not significant. In the CHF group heart rate variability was significantly related to left ventricular ejection fraction but not associated with ventricular arrhythmias. The frequency of ventricular extrasystoles was significantly related to the high frequency component of heart rate variability (r = 0.54, p < 0.05) in the NHVT group. Stepwise multiple regression analysis showed that in the CHF group, heart rate variability was predominantly related to left ventricular ejection fraction (p < 0.05). There was no significant difference in heart rate variability between survivors (n = 34) and those who died suddenly (n = 6) at one year of follow up in the CHF group. CONCLUSION: In patients with congestive heart failure, heart rate variability is significantly decreased. The depressed heart rate variability is principally related to the degree of left ventricular impairment and is independent of aetiology and the presence of ventricular arrhythmias. The data suggest that analysis of heart rate variability does not help the identification of patients with congestive heart failure at increased risk of sudden death.

Adult↗

Radiofrequency catheter ablation of septal accessory atrioventricular pathways.

OBJECTIVE: Septal accessory atrioventricular pathways are recognised as being more difficult to ablate than pathways in other locations. This paper describes an experience of 48 consecutive patients with septal accessory pathways who had catheter ablation with radiofrequency current. PATIENTS AND METHODS: There were 28 male and 20 female patients, mean (SD) age 35 (17). 43 patients had a single accessory pathway and 5 patients had multiple accessory pathways. Pre-excitation was present in 37 patients, and 11 patients had concealed accessory pathways. 21 patients had had a previous electrophysiological study. Catheter ablation was undertaken with radiofrequency current delivered by a standard unipolar technique or by delivery of current across the septum (the bipolar technique). RESULTS: The median total procedure time was 167 (83) minutes including a 30-40 minute observation period after the abolition of conduction by the accessory pathway. The median total fluoroscopic time was 56 (30) minutes. 42 (88%) out of 48 patients had successful ablation of the pathway during the first session. In the six patients in whom the procedure failed, five had a midseptal pathway and one had a right anteroseptal pathway. A second attempt at ablation was made in two patients and succeeded in both. In total, 49 accessory pathways were successfully ablated in 44 (92%) out of 48 patients. The bipolar technique was used in 11 patients and succeeded in 10 patients. Standard unipolar current delivery had previously failed in seven of the 11 patients. Complications developed in two patients with a mid septal pathway (one with complete atrioventricular block and the other with a small pericardial effusion). CONCLUSION: Radiofrequency catheter ablation of septal accessory pathways is efficacious and safe. The procedure time can be shortened and success rate can be increased after improvement of the technique--that is, consideration of a bipolar approach for energy delivery in difficult cases.

Adolescent↗

Effects of long-term oral magnesium chloride replacement in congestive heart failure secondary to coronary artery disease.

Magnesium deficiency frequently develops in patients with congestive heart failure and may increase susceptibility to lethal arrhythmias and sudden death via multiple pathophysiologic mechanisms. The effects of peroral magnesium supplementation were investigated in a randomized, double-blind, crossover trial involving 21 patients with stable congestive heart failure secondary to coronary artery disease. All were receiving long-term loop diuretics, and had normal renal function, and low or normal serum magnesium concentrations. Subjects alternately received enteric-coated magnesium chloride (15.8 mmol magnesium per day) and placebo for 6 weeks. Magnesium therapy increased serum magnesium from 0.87 +/- 0.07 to 0.92 +/- 0.05 mmol/liter (p < 0.05), serum potassium from 4.0 +/- 0.3 to 4.3 +/- 0.4 mmol/liter (p < 0.01) and urinary magnesium excretion from 2.82 +/- 0.96 to 4.74 +/- 2.38 mmol/24 hours (p = 0.001). There was no significant change in heart rate or Doppler cardiac index, but mean arterial pressure decreased from 91 +/- 10 to 87 +/- 10 mm Hg (p < 0.05) and systemic vascular resistance from 1,698 +/- 367 to 1,613 +/- 331 dynes s cm-5 (p = 0.047). The frequency of isolated ventricular premature complexes was reduced by 23% (95% confidence interval [CI] 6 to 37%; p < 0.02), couplets by 52% (95% CI 30 to 65%; p < 0.001) and nonsustained ventricular tachycardia episodes by 24% (95% CI 15 to 49%; p < 0.01). Plasma epinephrine decreased from 447 +/- 535 to 184 +/- 106 pg/ml (p = 0.02), but there was no corresponding change in plasma norepinephrine or heart rate variability.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Oral↗

Impaired immediate vasoconstrictor responses in patients with recurrent neurally mediated syncope.

Immediate responses to head-up tilt were determined in 78 consecutive patients with unexplained syncope undergoing 45-minute tilt tests at 60 degrees. Thirty-four patients developed neurally mediated syncope (mean time to syncope 18 minutes), 40 tolerated the full duration of tilt, and 4 were unable to complete the study but did not develop syncope. Blood pressure, heart rate, forearm blood flow and forearm vascular resistance were measured at baseline and after 2 and 5 minutes of tilt. Syncopal and nonsyncopal patients were well-matched for age and baseline hemodynamic parameters. There was no difference between the groups in heart rate or blood pressure at 2 minutes, but there was a small but significant difference in percent reduction in mean arterial pressure at 5 minutes. After 2 and 5 minutes of tilt, mean forearm blood flow was 2.4 and 2.6 ml/min/100 ml, respectively, in syncopal patients compared with 1.6 (p < 0.05) and 1.7 ml/min/100 ml (p < 0.01), respectively, in patients who tolerated 45 minutes of tilt. In syncopal patients, forearm vascular resistance was 51.0 and 44.0 at 2 and 5 minutes, respectively, whereas in nonsyncopal patients, it was 82.4 (p < 0.02) and 73.1 (p < 0.001), respectively. These differences remained consistent when only data for patients developing syncope after > 15 minutes were included in the analysis. Patients with neurally mediated syncope have clearly demonstrable abnormalities in vascular control immediately after assumption of the upright posture. The results shed new light on the pathophysiology of neurally mediated syncope.

Adolescent↗

Radiofrequency current delivery by way of a bipolar tricuspid annulus-mitral annulus electrode configuration for ablation of posteroseptal accessory pathways.

OBJECTIVES: This report describes a novel technique for ablation of "difficult" posteroseptal pathways. BACKGROUND: Although radiofrequency ablation of accessory atrioventricular (AV) pathways is successful in > or = 90% of cases, particular difficulty may be encountered with some bypass tracts in the posteroseptal region. METHODS: In eight patients with posteroseptal accessory pathways (two concealed), radiofrequency catheter ablation using conventional unipolar current applications from favorable sites along the tricuspid or mitral annulus, or both, was unsuccessful. Subsequently, a bipolar technique was adopted, with current application between the distal electrodes of two catheters positioned against the septal region at sites of early activation along both mitral and tricuspid annuli. RESULTS: The bipolar configuration proved effective in all cases. The number of bipolar lesions required for success was one (five patients), five (two patients) and nine (one patient). In five patients, bipolar current application abolished pathway conduction using positions at which delivery of unipolar lesions had been ineffective or caused transient block. The AV or ventriculoatrial interval at successful sites varied from 20 to 65 ms, and the time from delta wave onset to local ventricular activation was zero or negative. There were no complications attributable to the bipolar technique. During follow-up of 8 to 36 weeks, pathway conduction has not recurred in any patient. CONCLUSIONS: Bipolar radiofrequency current delivery across the septal region using a tricuspid annulus-mitral annulus electrode configuration may abolish accessory pathway conduction when conventional unipolar applications have proved ineffective. The technique may reduce procedure duration, radiation exposure and overall failure rate in these problematic cases.

Adolescent↗

Assessment of autonomic function in patients with neurally mediated syncope: augmented cardiopulmonary baroreceptor responses to graded orthostatic stress.

OBJECTIVES: The purpose of this study was to assess vagal tone and cardiopulmonary baroreceptor activity in patients with tilt-induced neurally mediated syncope. BACKGROUND: The causes of individual susceptibility to orthostatic stress leading to recurrent neurally mediated syncope remain obscure. The trigger for sympathetic withdrawal and increased vagal activity is believed to be stimulation of ventricular mechanoreceptors. METHODS: Seventeen patients (mean age 50.6 years) with recurrent syncope and a positive response on a 45-min 60 degrees head-up tilt test were compared with a control group of 17 patients (mean age 47.5 years) with unexplained syncope and negative tilt test findings. Vagal activity was assessed by high pressure baroreceptor testing and by temporal and spectral analysis of heart rate variability during Holter ambulatory electrocardiographic monitoring. Cardiopulmonary baroreceptor sensitivity was assessed by measurement of forearm vascular responses to lower body negative pressure. RESULTS: Mean high pressure baroreceptor sensitivity was 16.4 +/- 12.2 ms/mm Hg in the group with a positive tilt test response compared with 15.1 +/- 13.0 ms/mm Hg in the control group (p = NS). There were no significant differences between the groups in any of the temporal or spectral measures of heart rate variability. The increase in forearm vascular resistance in response to lower body negative pressure was 11.5 +/- 14.2 U in patients with tilt-induced syncope and 3.5 +/- 3.2 U in the control group at -5 mm Hg, 16.8 +/- 18.6 U and 4.8 +/- 5.3 U, respectively, at -10 mm Hg and 26.4 +/- 24.3 U and 10.2 +/- 7.8 U, respectively, at -20 mm Hg (p < 0.001). CONCLUSIONS: Patients with tilt-induced neurally mediated syncope have augmented cardiopulmonary baroreceptor responses to orthostatic stress. This finding sheds new light on the etiology of neurally mediated syncope.

Adult↗

Effects of procainamide on the signal-averaged electrocardiogram in relation to the results of programmed ventricular stimulation in patients with sustained monomorphic ventricular tachycardia.

OBJECTIVES: The aim of this study was to assess the ability of the signal-averaged electrocardiogram (ECG) to predict the efficacy of procainamide. BACKGROUND: The main role of the signal-averaged ECG has been the identification of postinfarction patients at risk of sudden death. Prediction of the efficacy of antiarrhythmic drugs represents another potential clinical application of this technique. METHODS: The study examined the effects of procainamide on the time domain and spectral temporal analysis of the signal-averaged ECG in relation to the results of programmed ventricular stimulation studies in 31 patients with inducible sustained monomorphic ventricular tachycardia. RESULTS: Procainamide significantly prolonged the total and the initial QRS complex and low amplitude signal durations (mean +/- SD 135 +/- 30 vs. 161 +/- 46 ms, p < 0.0001; 87 +/- 16 vs. 98 +/- 20 ms, p < 0.0001, and 48 +/- 23 vs. 63 +/- 36 ms, p < 0.001, respectively) whereas the root-mean-square voltage of the total QRS complex and of the last 40 ms of the QRS complex was significantly reduced (mean +/- SD 112 +/- 36 vs. 87 +/- 36 microV, p < 0.0001; 21 +/- 19 vs. 13 +/- 12 microV, p < 0.002, respectively). The results of spectral temporal mapping of the signal-averaged ECG were similar before and after procainamide administration. Procainamide prevented the inducibility of sustained ventricular tachycardia or prolonged the cycle length of ventricular tachycardia by > or = 100 ms in 16 patients (52%) (responders). The fractional prolongation of the total QRS duration was significantly greater in responders (26 +/- 15%) than in nonresponders (10 +/- 10%) (p < 0.002) and, when this prolongation was > or = 15%, identified responders with a sensitivity of 94%, a specificity of 87% and an overall predictive accuracy of 90%. CONCLUSIONS: The effects of procainamide on inducibility of ventricular tachycardia during programmed ventricular stimulation can be predicted by the degree of drug-induced prolongation of the signal-averaged QRS complex.

Aged↗

Radiofrequency ablation of accessory atrioventricular pathways: predictive value of local electrogram characteristics for the identification of successful target sites.

BACKGROUND: Radiofrequency catheter ablation of accessory arterioventricular pathways has been shown to be a highly effective treatment in patients with paroxysmal superventricular tachycardia. There is, however, considerable variability in the number of attempted ablation sites, contributing to lengthy operations in some cases. The purpose of this study was to investigate the predictive value of local electrogram characteristics for the identification of successful target sites. METHODS AND RESULTS: Local bipolar electrograms from 60 patients recorded at 568 sites of attempted ablation were analysed. There were 511 sites at which ablation was guided by antegrade mapping, with 49 successful sites and 462 failed sites including 61 at which accessory pathway conduction was blocked temporarily. In multivariate analysis, the time of local ventricular activation relative to onset of the QRS complex (QRS-V interval) (p < 0.001) and the presence of a possible accessory pathway potential (p < 0.05) were found to be independent predictors of successful outcome, whereas the atrioventricular interval, atrioventricular amplitude ratio, stability of local electrogram, and presence of continuous electrical activity were not. A QRS-V interval of < or = +10 ms identified successful sites with a sensitivity of 98%, but the positive predictive accuracy was only 11%. Even a QRS-V interval of < or = 20 ms resulted in only a 24% probability of success with a sensitivity of just 18%. Combining the QRS-V interval with the presence of a possible accessory pathway potential greatly reduced the sensitivity at all cut off values, but failed to increase positive predictive accuracy above 25%. There were no significant differences in electrogram characteristics between the successful sites and the sites at which conduction of the accessory pathway was interrupted transiently. There were 57 sites (nine successful, 48 failed) at which ablation was guided by retrograde mapping, but none of the local electrogram characteristics analysed emerged as independent predictors of successful pathway ablation. CONCLUSION: Local electrogram characteristics used to guide radiofrequency catheter ablation are all associated with a low positive predictive accuracy, which significantly contributes to duration of the operation. It is unlikely that this problem will be resolved solely by modification of the mapping techniques. It could require advances in catheter technology and power sources to enable larger tissue lesions to be delivered more reliably than is possible with the equipment in current use.

Adolescent↗

Increased renal and forearm vasoconstriction in response to exercise after heart transplantation.

OBJECTIVE: To test the hypothesis that the loss of the inhibitory effect of the cardiac ventricular afferent fibres on the vasomotor centre would result in increased vasoconstrictor drive to the forearm and renal vascular beds during supine exercise in heart transplant recipients. DESIGN: Comparison of regional haemodynamic response to exercise in heart transplant recipients and two age matched control groups. SETTING: Regional heart transplant unit. PATIENTS AND METHODS: Orthotopic heart transplant recipients (n = 10), patients with NYHA class II heart failure (n = 10), and normal controls (n = 10) underwent short duration maximal supine bicycle exercise. MAIN OUTCOME MEASURES: Simultaneous measurements were made of heart rate, systemic blood pressure, oxygen consumption (VO2), forearm blood flow, and renal blood flow. Forearm blood flow was measured by forearm plethysmography and renal blood flow by continuous renal vein thermodilution. RESULTS: The peak forearm vascular resistance was significantly greater in the transplant group than in the controls (mean (SEM) 75 (18) v 40 (7) resistance units, p < 0.05). The percentage fall in renal blood flow at peak exercise was significantly greater in heart transplant recipients than in the controls (44% (4%) v 32% (4%), p < 0.05) as was the percentage increase in renal vascular resistance (transplants: 116% (19%) v controls: 78% (17%), p < 0.05). Regional haemodynamics during exercise in the heart failure group were not significantly different from those in the controls. CONCLUSIONS: These findings suggest that surgical division of the cardiac ventricular afferent fibres results in increased vasoconstrictor drive to the kidneys and non-exercising muscle during exercise. This mechanism may contribute to persistent exercise limitation and renal impairment after heart transplantation.

Adult↗

Assessment of heart rate variability in hypertrophic cardiomyopathy. Association with clinical and prognostic features.

BACKGROUND: Altered vascular responses during exercise and disturbed responses to autonomic function testing have been documented in hypertrophic cardiomyopathy (HCM) and are associated with markers of an adverse prognosis. Reduced heart rate variability (HRV) and baroreflex sensitivity are predictors of increased risk of sudden death after myocardial infarction, but the value of these parameters in HCM is unknown. METHODS AND RESULTS: To determine the clinical significance of HRV and its relation to markers of electrical and hemodynamic instability in HCM, the 24-hour Holter recordings of 104 patients in sinus rhythm and off medication were analyzed. Five nonspectral measures of HRV were computed. The frequency components of HRV were calculated by fast Fourier transformation of the RR time intervals; the areas under the low (0.04 to 0.15 Hz) and high (0.15 to 0.4 Hz) frequency portions of the spectrum were measured as indices of autonomic and specific vagal influences on HRV, respectively. Spectral and nonspectral measures were compared with clinical, echo/Doppler, and Holter variables. ANCOVA was performed to allow for the effect of age on differences between variables. Spectral and nonspectral measures of HRV were correlated (r > .65; P < or = .001), indicating that the different time-domain and frequency parameters reflected similar measures of HRV. Global measures of HRV including the standard deviation of the mean of RR intervals (SDRR) and the standard deviation of 5-minute mean RR intervals (SDANN) were increased in patients with an adverse family history of HCM (173 +/- 67 vs 131 +/- 38 milliseconds, P = .001, and 158 +/- 66 vs 116 +/- 36 milliseconds, P = .004, respectively). In patients with exertional chest pain, global nonspectral measures were reduced compared with asymptomatic patients (118 +/- 31 vs 152 +/- 53 milliseconds, P = .006, and 105 +/- 30 vs 136 +/- 52 milliseconds, P = .014, respectively). Specific vagal influences on HRV including the proportion of RR intervals more than 50 milliseconds different (PNN50) and the high frequency peak on spectral analysis were less in patients with supraventricular arrhythmias on Holter monitoring (7.2 +/- 8 vs 16 +/- 13%, P = .012, and 21 +/- 10 vs 28 +/- 13 milliseconds, P = .048, respectively). Similarly, both global and specific vagal measures of HRV were less in the 27 patients with nonsustained ventricular tachycardia on Holter (PNN50, 7.7 +/- 9 vs 15 +/- 13 milliseconds, P = .048, and high frequency component, 19 +/- 9 vs 28 +/- 13 milliseconds, P = .05. During follow-up, 10 patients, 9 of whom were aged less than 33 years, experienced catastrophic events; 6 were resuscitated from ventricular fibrillation and 4 died suddenly. Indices of HRV were similar in these 10 patients to indices in the 94 survivors. CONCLUSIONS: Time-domain and spectral measures of HRV yield similar information about the specific autonomic influences on the heart. Global and specific vagal influences on HRV were reduced in patients with symptoms and arrhythmias and global HRV is increased in patients with an adverse family history of HCM, but these indices do not add to the predictive accuracy of established risk factors.

Adult↗