Search PubMed⌕ Search

Biomedical subjects

Y A Ding

Publications and source records attributed to Y A Ding.

At least 37 records · Page 2Linked to original sources

Impact of transisthmus linear ablation of typical atrial flutter on coronary sinus activation time.

Complete or incomplete bidirectional isthmus conduction block after linear ablation of atrial flutter is difficult to interpret without detailed multiple electrodes mapping along the tricuspid annulus and the low right atrial isthmus area. The influence of isthmus block on the intraatrial septal and coronary sinus activation has not been assessed by endocardial mapping. This study was designed to analyze the intraartial and interatrial activation times in a retrospective fashion to investigate (1) whether isthmus conduction block can change the coronary sinus activation sequence during low lateral right atrial pacing, and (2) the correlation between change of coronary sinus activation time and isthmus conduction block. Sixty-five consecutive patients (mean age, 57 +/- 18 years) with clinically documented typical atrial flutter were studied. A 20-pole "Halo" catheter was placed around the tricuspid annulus including the entire low right atrial isthmus to verify complete bidirectional isthmus block. Activation time from ostium to distal coronary sinus (OCS-->DCS), and interatrial septum and isthmus activation times during right atrial pacing were analyzed and compared before and after incomplete or complete isthmus block. Complete bidirectional isthmus block was achieved in 50 (77%) patients. During low lateral right atrial pacing, linear ablation at low right atrial isthmus results in a significant delay of activation in all coronary sinus recording sites with greater extent at the ostium area without influence on interatrial septum activation in complete and incomplete isthmus conduction block. The difference of the OCS-->DCS interval before and after ablation, delta (OCS-->DCS), was well correlated with results of isthmus conduction block and significantly longer in patients with complete than those with incomplete isthmus block (34 +/- 11 vs 11 +/- 8 ms, P < 0.001), thereby allowing a value of 20 ms as a discriminative parameter to differentiate incomplete (< 20 ms) from complete (> or = 20 ms) isthmus counterclockwise conduction block with a sensitivity of 96% and a specificity of 88%. In conclusion, creation of a line of block at the inferior vena cava-tricuspid annulus isthmus could change coronary sinus activation sequence during low lateral right atrial pacing in sinus rhythm. The change of coronary sinus activation time after linear ablation, delta (OCS-->DCS), was well correlated with isthmus conduction block by using a value > or = 20 ms to discern complete counterclockwise isthmus block.

Adolescent↗

Proarrhythmic effects of ibutilide in a canine model of pacing induced cardiomyopathy.

The authors developed a canine model of pacing induced cardiomyopathy to study the possible mechanisms of ibutilide induced torsades de pointes (TP) in heart failure. Thirteen dogs received intravenous ibutilide after acute AV block for 60 minutes, and after implantation of a VVI pacemaker, with a rate of 270 beats/min for 2-3 weeks. Twelve-lead ECG and right and left ventricle monophasic action potentials were recorded at different right ventricle pacing cycle lengths from 600 ms to 1200 ms during the study. The results showed ibutilide could significantly prolong ventricular repolarization and increase the dispersion in a dose dependent and reverse use dependent manner. Furthermore, after ibutilide administration, cardiomyopathic dogs had a greater dispersion of ventricular repolarization, and also had higher incidences of early afterdepolarizations and spontaneous or pacing induced TP than acute AV block dogs.

Action Potentials↗

Ventricular tachycardia in a patient with primary hyperparathyroidism.

We present a case of primary hyperparathyroidism with hypercalcemia in a patient who had spontaneous attacks of ventricular tachycardia. Right ventricular burst pacing reproducibly induced ventricular tachycardia in the electrophysiological laboratory after intravenous administration of calcium-gluconate, and verapamil could terminate the tachycardia. After resection of the parathyroid adenoma, the calcium level was restored to normal, and ventricular tachycardia did not occur again during the follow-up period.

Adenoma↗

Prevention of the initiation of atrial fibrillation: mechanism and efficacy of different atrial pacing modes.

Several atrial pacing modes have been reported to be effective in the prevention of atrial fibrillation (AF); they included biatrial pacing, dual site right atrial pacing, Bachmann's bundle (BB) pacing, and coronary sinus pacing. However, the relative efficacy and electrophysiological mechanisms of these pacing modes in the prevention of AF are not clear. In 15 patients (age 54 +/- 14 years) with paroxysmal AF, P wave duration, effective refractory period, and atrial conduction time were determined with six different atrial drive pacings, that were right atrial appendage (RAA), BB, right posterior interatrial septum (RPS), distal coronary sinus (DCS), RAA plus RPS simultaneously (DSA), and RAA plus DCS simultaneously (BiA). All these patients consistently had AF induced with early RAA extrastimulation coupling to RAA drive pacing. No patient had AF induced with RAA extrastimulation coupled to BB, RPS, or DCS drive pacing, but seven and eight patients had AF induced with RAA extrastimulation coupled to DSA and BiA drive pacing, respectively. The P wave duration was longest during RAA pacing, and became shorter during other atrial pacing modes. Analysis of electrophysiological change showed that early RAA extrastimulation coupled to RAA drive pacing caused the longest atrial conduction delay among these atrial pacing modes; BB, RPS, and DCS drive pacing caused a greater reduction of this conduction delay than DSA and BiA drive pacing. In addition, the effective refractory periods of RAA determined with BB, RPS, and DCS drive pacing were similar and longer than that determined with DSA and BiA drive pacing. In patients with paroxysmal AF, this arrhythmia was readily induced with RAA extrastimuli coupled to RAA drive pacing. BB, RPS, and DCS pacing were similar and more effective than DSA and BiA pacing in preventing AF.

Adolescent↗

Atrial tachycardias originating from the atrial septum: electrophysiologic characteristics and radiofrequency ablation.

INTRODUCTION: The characteristics of atrial tachycardia (AT) have varied widely among different reports. The anatomic locations of ATs may bias the results. We propose that septal ATs and free-wall ATs have different characteristics. METHODS AND RESULTS: One hundred forty-one patients with AT underwent electropharmacologic study, endocardial mapping, and radiofrequency ablation. Forty-nine (34.7%) patients had septal AT originating from the anteroseptal, mid-septal, and posteroseptal areas. Tachycardia cycle length was similar between septal AT and free-wall AT (367 +/- 46 msec vs 366 +/- 58 msec, P > 0.05). More patients with septal AT required isoproterenol to facilitate induction (44.9% vs 31.5%, P <.0.05). Septal AT was more sensitive to adenosine than free-wall AT (84.4% vs 67.8%, P < 0.05). Only posteroseptal AT showed a positive P wave in lead V1 and negative P wave in all the inferior leads (II, III, aVF). Radiofrequency catheter ablation had a comparable success rate for septal AT and free-wall AT (96% vs 95%) without impairment of AV conduction. During follow-up of 49 +/- 13 months (range 17 to 85), the recurrence rate was similar for septal AT and free-wall AT (3.2% vs 4.6%, P = 0.08). CONCLUSION: Septal AT has electrophysiologic characteristics that are distinct from those of free-wall AT. Catheter ablation of the septal AT is safe and effective.

Adult↗

Predicting the arrhythmogenic foci of atrial fibrillation before atrial transseptal procedure: implication for catheter ablation.

INTRODUCTION: Use of endocardial atrial activation sequences from recording catheters in the right atrium, His bundle, and coronary sinus to predict the location of initiating foci of atrial fibrillation (AF) before an atrial transseptal procedure has not been reported. The purpose of the present study was to develop an algorithm using endocardial atrial activation sequences to predict the location of initiating foci of AF before transseptal procedure. METHODS AND RESULTS: Seventy-five patients (60 men and 15 women, age 68 +/- 12 years) with frequent episodes of paroxysmal AF were referred for radiofrequency ablation. By retrospective analysis, characteristics of the endocardial atrial activation sequences of right atrial, His-bundle, and coronary sinus catheters from the initial 37 patients were correlated with the location of initiating foci of AF, which were confirmed by successful ablation. The endocardial atrial activation sequences of the other 38 patients were evaluated prospectively to predict the location of initiating foci of AF before transseptal procedure using the algorithm derived from the retrospective analysis. Accuracy of the value <0 msec (obtained by subtracting the time interval between high right atrium and His-bundle atrial activation during atrial premature beats from that obtained during sinus rhythm) for discriminating the superior vena cava or upper portion of the crista terminalis from the pulmonary vein (PV) foci was 100%. When the interval between atrial activation of ostial and distal pairs of the coronary sinus catheter of the atrial premature beats was <0 msec, the accuracy for discriminating left PV foci from right PV foci was 92% in the 24 foci from the left PVs and 100% in the 19 foci from the right PVs. CONCLUSION: Endocardial atrial activation sequences from right atrial, His-bundle, and coronary sinus catheters can accurately predict the location of initiating foci of AF before transseptal procedure. This may facilitate mapping and radiofrequency ablation of paroxysmal AF.

Adult↗

Pulmonary vein electrogram characteristics in patients with focal sources of paroxysmal atrial fibrillation.

INTRODUCTION: The major source of ectopic beats initiating paroxysmal atrial fibrillation (AF) is from pulmonary veins (PVs). However, the electrogram characteristics of PVs are not well defined. METHODS AND RESULTS: Group I consisted of 129 patients with paroxysmal AF. Group II consisted of 10 patients with a concealed left-sided free-wall accessory pathway. All group I patients had spontaneous AF initiated by ectopic beats, including 169 ectopic foci originating from the PVs. We analyzed PV electrograms from the 169 ectopic foci during sinus beats and ectopic beats. During AF initiation, most (70%) ectopic beats showed PV spike potential followed by atrial potential; 16% of ectopic beats showed PV fragmented potential followed by atrial potential; and 14% showed fusion potentials. The coupling interval between the sinus beat and the ectopic beat was significantly shorter in the inferior PVs than in the superior PVs (171 +/- 48 msec vs 222 +/- 63 msec, P = 0.001) and was significantly shorter in the distal foci than in the ostial foci of PVs (206 +/- 52 msec vs 230 +/- 56 msec, P = 0.01). The incidence of conduction block in the PVs during AF initiation was significantly higher in the inferior PVs than in the superior PVs (12/24 vs 37/145, P = 0.03) and was significantly higher in the distal foci than in the ostial foci of PVs (43/121 vs 6/48, P = 0.04). The maximal amplitude of PV potential was significantly larger in the left PVs than in the right PVs, and the maximal duration of PV potential was significantly longer in the superior PVs than in the inferior PVs during sinus beats in both group I and II patients. CONCLUSION: PV electrogram characteristics were different among the four PVs. Detailed mapping and careful interpretation are the most important steps in ablation of paroxysmal AF originating from PVs.

Adult↗

Recombinant adeno-associated virus expressing human papillomavirus type 16 E7 peptide DNA fused with heat shock protein DNA as a potential vaccine for cervical cancer.

In this study, we explore a potential vaccine for human papillomavirus (HPV)-induced tumors, using heat shock protein as an adjuvant, a peptide vaccine for safety, and adeno-associated virus (AAV) as a gene delivery vector. The tumor vaccine was devised by constructing a chimeric gene which contained HPV type 16 E7 cytotoxic T-lymphocyte (CTL) epitope DNA (M. C. Feltkamp, H. L. Smits, M. P. Vierboom, R. P. Minnaar, B. M. de Jongh, J. W. Drijfhout, J. ter Schegget, C. J. Melief, and W. M. Kast, Eur. J. Immunol. 23:2242-2249, 1993) fused with the heat shock protein gene as a tumor vaccine delivered via AAV. Our results demonstrate that this vaccine can eliminate tumor cells in syngeneic animals and induce CD4- and CD8-dependent CTL activity in vitro. Moreover, studies with knockout mice with distinct T-cell deficiencies confirm that CTL-induced tumor protection is CD4 and CD8 dependent. Taken together, the evidence indicates that this chimeric gene delivered by AAV has potential as a cervical cancer vaccine.

Animals↗

Alterations of heart rate variability after radiofrequency catheter ablation of focal atrial fibrillation originating from pulmonary veins.

BACKGROUND: Transient sinus bradycardia and hypotension have been reported as complications during radiofrequency (RF) ablation of focal atrial fibrillation (AF) originating from pulmonary veins (PVs). This study used heart rate variability (HRV) to evaluate the effects of focal PVs ablation on autonomic function. METHODS AND RESULTS: Thirty-seven patients with paroxysmal AF were referred for ablation. The study group included 30 patients who underwent transseptal ablation of PVs, and the control group included 7 patients who underwent the transseptal procedure without ablation. The mean sinus rate and time-domain (standard deviation of RR intervals and root-mean-square of differences of adjacent RR intervals) and frequency-domain (low frequency, high frequency, and low-frequency/high-frequency ratio) analyses of HRV were obtained by use of 24-hour Holter monitoring before and 1 week, 1 month, and 6 months after ablation. All the triggering points of AF were from PVs, and they were successfully ablated. Severe bradycardia and hypotension were noted during ablation of PVs in 6 patients (group IA); 24 patients without the above complication belonged to group IB. Compared with preablation values, a significant increase in mean sinus rate and low-frequency/high-frequency ratio and a significant decrease in standard deviation of RR intervals, root-mean-square of differences of adjacent RR intervals, low frequency, and high frequency were noted in groups IA and IB patients 1 week after ablation. The changes in HR and HRV recovered spontaneously in the 2 subgroups by 1 month later. These parameters of HRV did not change in the control group after the transseptal procedure. CONCLUSIONS: Transient autonomic dysfunction with alterations in HR and HRV occurred after ablation of focal AF originating from PVs.

Adult↗

Antiplatelet effect of amlodipine: a possible mechanism through a nitric oxide-mediated process.

The effect of amlodipine, a novel calcium channel blocker of the dihydropyridine type, on rabbit platelet aggregation, and the possible antiaggregatory mechanisms of amlodipine, especially on the nitric oxide (NO) guanosine 3',5'-cyclic monophosphate (cyclic GMP)-mediated pathway, were investigated. Other effects of amlodipine on thromboxane B2 (TXB2) formation in platelets also were examined. Amlodipine concentration-dependently inhibited rabbit platelet aggregation induced by collagen (10 microg/mL) or thrombin (0.1 U/mL) with an IC50 range of 32-69 microM. Along with this inhibition, our results also demonstrated that in the presence of L-arginine (100 IM), amlodipine (50 microM) increased nitric oxide synthetase (NOS) activity (from the resting activity of 2.05+/-0.36 to 7.11+/-0.95 pmol/mg protein/min) and NO release (by 80%), accompanied by an elevation of the cyclic GMP level (from the resting platelet level of 1.27+/-0.12 to 6.21+/-0.55 pmol/10(9) platelets) induced by collagen (10 microg/mL). However, the antiaggregatory effect of amlodipine (50 microM) could be attenuated significantly by oxyhemoglobin (5 microM), a NO scavenger, or N(G)-nitro-L-arginine methyl ester (100 microM), a specific NOS inhibitor. In addition, the TXB2 production in platelets induced by collagen or thrombin was concentration-dependently inhibited by amlodipine. Therefore, we propose that the antiaggregatory mechanisms of amlodipine might be mediated, in part, by a NO-cyclic GMP process accompanied by the inhibition of TXB2 formation in platelets.

Amlodipine↗

Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation.

BACKGROUND: Atrial fibrillation (AF) can be initiated by ectopic beats originating from the atrial or great venous tissues. This study investigated the anatomic characteristics and electrophysiological properties of pulmonary veins (PVs), as well as the possible mechanisms and response to drugs of ectopic foci, and assessed the effects of radiofrequency (RF) ablation on AF initiated by ectopic beats originating from PVs. METHODS AND RESULTS: Seventy-nine patients with frequent episodes of paroxysmal AF and 10 control patients were included. Distal PVs showed the shortest effective refractory periods (ERPs), and right superior PVs showed a higher incidence of intra-PV conduction block than left superior PVs. Superior and left PVs had longer myocardial sleeves than inferior and right PVs, respectively. These electrophysiological characteristics were similar between AF and control patients. Propranolol, verapamil, and procainamide suppressed ectopic beats that originated from the PVs. Of 116 ectopic foci that initiated AF, 103 (88.8%) originated from PVs. A mean of 7+/-3 RF applications completely eliminated 110 ectopic foci (94.8%). During the 6+/-2-month follow-up period, 68 patients (86. 1%) were free of AF without any antiarrhythmic drugs. Follow-up transesophageal echocardiogram showed 42.4% of ablated PVs had focal stenosis. One patient had mild exertional dyspnea after ablation, but it resolved 3 months later; 1 patient had onset of mild exertional dyspnea 5 months after ablation. CONCLUSIONS: Electrophysiological characteristics of PVs are different from those in the atria. Ectopic beats from PVs can initiate AF, and beta-adrenergic receptor blocker, calcium channel blockers, and sodium channel blockers can suppress these ectopic beats. Careful mapping and elimination of these ectopic foci can cure paroxysmal AF.

Adult↗

Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?

BACKGROUND: The prospective, randomized study comparing 4- with 8-mm tip electrodes for radiofrequency linear ablation of typical atrial flutter is not available. METHODS AND RESULTS: A total of 104 consecutive patients with typical atrial flutter were randomly assigned to undergo radiofrequency linear ablation using a 4- (Group I, n=54) or 8-mm tip electrode (Group II, n=50) catheter (temperature-control model, preset 70 degrees C). If complete bidirectional isthmus block could not be achieved after 5 pulses, the ablation catheter was changed to the other type; the maximal radiofrequency pulse number was limited to <10 pulses. Complete or incomplete isthmus conduction block was assessed by activation sequence in a multielectrode Halo catheter during low lateral right atrial and proximal coronary sinus pacing. Before shifting to the other catheter type, the 8-mm electrode catheter achieved higher complete isthmus block rate (92% versus 67%, P<0.05) with fewer pulses (2+/-1 versus 3+/-1, P<0.05), shorter procedure time (24+/-15 versus 31+/-12 minutes, P<0.05), and shorter fluoroscopic time (14+/-10 versus 23+/-15 minutes, P<0.05). After 5 failed ablation pulses, 12 (67%) of 18 patients in group I attained complete isthmus block by using an 8-mm tip catheter, but none of 4 patients in group II achieved complete block by changing to a 4-mm tip catheter. CONCLUSIONS: The 8-mm tip electrodes are more effective than the standard 4-mm length electrodes in linear ablation for typical atrial flutter. This clinical benefit may be of particular value for some patients with broad and/or thick isthmus.

Aged↗

Reversal of atrial electrical remodeling following cardioversion of long-standing atrial fibrillation in man.

BACKGROUND: In animal studies, atrial fibrillation has been shown to shorten the atrial refractory period and impair its rate adaptation. However, little is known about the effects of chronic atrial fibrillation on atrial electrophysiology and its recovery course in humans. METHODS AND RESULTS: Nineteen patients, mean age 64 +/- 14 years, with chronic atrial fibrillation of more than six months duration were included in this study. All of them were successfully converted to sinus rhythm with an external defibrillator. Atrial effective refractory periods at right atrial appendage and distal coronary sinus were determined with five pacing cycle lengths (300, 400, 500, 600 and 700 ms) at 30 min after cardioversion and once a day for four days. The atrial conduction properties, including P wave duration of surface ECG, and right and left atrial conduction times, were also measured at the same time interval. Twenty age-matched patients without a history of atrial tachyarrhythmia were evaluated as controls. In comparison with controls, chronic atrial fibrillation significantly shortened the atrial effective refractory period, impaired its rate adaptation response, especially at distal coronary sinus, and depressed the conduction properties of atria. The atrial conduction properties did not change during the four-day follow-up period; however, the atrial effective refractory period was gradually prolonged and its rate adaptation response improved after restoration of sinus rhythm. CONCLUSIONS: In humans, chronic atrial fibrillation significantly shortened the atrial effective refractory period, and impaired its rate adaptation response. Restoration and maintenance of sinus rhythm could reverse these electrophysiological changes.

Aged↗

Stimulation of TNF-alpha, IL-1beta and nitrite release from mouse cultured spleen cells and lavaged peritoneal cells by mastoparan M.

Chemically synthesized mastoparan M, a tetradecapeptide toxin of venom (INLKAIAALAKKLL), was used in the experiments described. After addition of mastoparan M to cultures of mouse macrophages in vitro, tumour necrosis factor-alpha (TNF-alpha) and interleukin 1beta (IL-1beta) were detected in the culture fluids by 12 h and their highest accumulation was observed by 24 h. Mastoparan M induced increases in both TNF-alpha secretion and mRNA level at the same time. Nitrite levels, which reflect nitric oxide synthesis, were also found to increase in the macrophage cultures at 24 h after mastoparan M addition. In vivo studies showed that mastoparan M induced the formation and accumulation of TNF-alpha, IL-1beta and nitrite in the peritoneal exudates of mice much faster at 90 min, 120 min and 180 min after mastoparan M injection, respectively. Similarly, significant increases in myeloperoxidase activity, a marker for neutrophil and macrophage content, were observed in the peritoneal lavage cells after intraperitoneal injection of mastoparan M. However, induction of nitrite by mastoparan M was completely inhibited by simultaneous addition of antimouse TNF-alpha antibody to the macrophage cultures. These results suggest that modulation of both neutrophil and macrophage influx by mastoparan M may be conveyed through TNF-alpha and IL-1beta secretion accompanied by nitrite formation.

Animals↗

Early recurrence of atrial fibrillation after external cardioversion.

UNLABELLED: Early recurrence of atrial fibrillation (AF) has been reported to occur in a significant number of patients after internal cardioversion. However, information about early recurrence of AF after external cardioversion has never been reported. The present study was conducted to investigate the clinical and electrophysiological characteristics of early recurrence of AF and its role in failure of cardioversion in patients with chronic AF. METHODS AND RESULTS: The study included 50 consecutive patients, age 69+/-9, with a history of chronic AF for more than 3 months duration and electrical cardioversion. They were divided into two groups according to the presence (group 1) or absence (group 2) of early recurrence of AF. There were 13 (26%) patients in group 1 and 37 (74%) patients in group 2. The age, gender, duration of AF, left ventricular function, left atrial dimension, and underlying heart disease were similar between group 1 and 2. Forty-five patients were successfully converted to sinus rhythm with a mean energy of 158+/-57 . Among those who failed to be converted to sinus rhythm, 4 (80%) belonged to group 1 and 1 (20%) belonged to group 2. The early recurrences of AF were initiated with consecutive APDs; but the numbers of APD in the first 30 seconds after cardioversion were similar between group 1 and 2. However, the coupling interval of the second APD was shorter in group 1 than group 2 (188+/-22 vs 324+/-59 ms, P = 0.003). Nine of the 13 early recurrences were prevented by an increase of shock energy (n = 3) or intravenous amiodarone infusion (n = 6). There were no differences in duration of follow-up, recurrence rate, and time interval to recurrence between group 1 and group 2. Early recurrence of AF occurred in 26% of chronic AF patients who underwent external electrical cardioversion and was a major cause of failure in cardioversion. Early recurrence of AF was initiated by APDs with decreasing coupling intervals and could be prevented with an increase of shock energy or amiodarone.

Aged↗

Persistent atrial flutter in patients treated for atrial fibrillation with amiodarone and propafenone: electrophysiologic characteristics, radiofrequency catheter ablation, and risk prediction.

INTRODUCTION: Antiarrhythmic drugs have been reported to promote the conversion of atrial fibrillation to atrial flutter in patients with paroxysmal atrial fibrillation. However, information about the electrophysiologic mechanism and response to radiofrequency ablation of these drug-induced atrial flutters is limited. Furthermore, the determinants of the development of persistent atrial flutter in patients treated for atrial fibrillation with antiarrhythmic drugs are still unknown. METHODS AND RESULTS: Among the 136 patients treated for atrial fibrillation with amiodarone (n = 96) or propafenone (n = 40), 15 (11%, mean age 65.5 +/- 12.3 years) were identified to have subsequent development of persistent atrial flutter based on surface ECG characteristics during antiarrhythmic drug treatment. The mean interval between the beginning of drug treatment and the onset of atrial flutter was 5.0 +/- 5.5 months. Intracardiac mapping and entrainment studies revealed that 11 patients had counterclockwise typical atrial flutter, and 4 had clockwise typical atrial flutter. All 15 patients underwent successful ablation with creation of complete bidirectional isthmus conduction block. After a mean follow-up of 12.3 +/- 4.2 months, 14 (93%) of 15 patients who underwent successful ablation and continued taking antiarrhythmic drugs have remained in sinus rhythm. Univariate analysis of clinical variables demonstrated that only atrial enlargement was significantly related to the occurrence of persistent atrial flutter. CONCLUSION: In patients with atrial fibrillation, persistent typical atrial flutter might occur during antiarrhythmic drug treatment, and atrial enlargement was a risk factor for the development of such an arrhythmia. Radiofrequency ablation and continuation of pharmacologic therapy offered a safe and effective means of achieving and maintaining sinus rhythm.

Aged↗

Bezold-Jarisch-like reflex during radiofrequency ablation of the pulmonary vein tissues in patients with paroxysmal focal atrial fibrillation.

INTRODUCTION: Information is lacking about the occurrence of ablation-related proarrhythmic events during application of radiofrequency (RF) energy at the pulmonary veins in patients with paroxysmal focal atrial fibrillation. The purpose of this study was to assess the theoretical risk of reflex bradycardia and hypotension response during RF ablation of these regions rich in endocardial nerve terminals. METHODS AND RESULTS: Among the 40 consecutive patients (29 men, 11 women; mean age 65+/-12 years) with clinically documented frequent attacks of paroxysmal atrial fibrillation who underwent superior pulmonary vein ablation for left focal atrial fibrillation, 6 patients (15%) developed bradycardia-hypotension syndrome during energy delivery. A single atrial fibrillation trigger focus in the left or right superior pulmonary vein was found in 3 and 1 patients, respectively. Two patients had two trigger foci originating from the orifice or proximal part of both superior pulmonary veins. After RF current was applied for a period of 14+/-10 seconds, 2 patients developed junctional rhythm and sinus bradycardia, another 2 patients had profound sinus bradycardia, 1 patient had two episodes of sudden onset of complete AV block with resultant 9.5-second asystole, and 1 patient showed profound sinus bradycardia, transient AV block, and an 8-second asystole due to sinus arrest. Blood pressure fell when any substantial bradyarrhythmias occurred. All 6 patients were free of rhythm disturbances during the postablation follow-up period (mean 8+/-2 months). CONCLUSION: RF catheter ablation of the pulmonary vein tissues could evoke a variety of profound bradycardia-hypotension responses. The Bezold-Jarisch-like reflex might be the underlying mechanism.

Adult↗