Search PubMed⌕ Search

Biomedical subjects

Xuezhu Liu

Publications and source records attributed to Xuezhu Liu.

3 recordsLinked to original sources

Electrokinetically based approach for single-nucleotide polymorphism discrimination using a microfluidic device.

In this work, we describe and implement an electrokinetic approach for single-nucleotide polymorphism (SNP) discrimination using a PDMS/glass-based microfluidic chip. The technique takes advantage of precise control of the coupled thermal (Joule heating), shear (electroosmosis), and electrical (electrophoresis) energies present at an array of probes afforded by the application of external electrical potentials. Temperature controllers and embedded thermal devices are not required. The chips can be easily and inexpensively fabricated using standard microarray printing methods combined with soft-lithography patterned PDMS fluidics, making these systems easily adaptable to applications using higher density arrays. Extensive numerical simulations of the coupled flow and thermal properties and microscale thermometry experiments are described and used to characterize the in-channel conditions. It was found that optimal conditions for SNP detection occur at a lower temperature on-chip than for typical microarray experiments, thereby revealing the importance of the electrical and shear forces to the overall process. To demonstrate the clinical utility of the technique, the detection of single-base pair mutations in the survival motor neuron gene, associated with the childhood disease spinal muscular atrophy, is conducted.

Cyclic AMP Response Element-Binding Protein↗

Electrokinetically controlled DNA hybridization microfluidic chip enabling rapid target analysis.

Biosensors and more specifically biochips exploit the interactions between a target analyte and an immobilized biological recognition element to produce a measurable signal. Systems based on surface nucleic acid hybridization, such as microarrays, are particularly attractive due to the high degree of selectivity in the binding interactions. One of the drawbacks of this reaction is the relatively long time required for complete hybridization to occur, which is often the result of diffusion-limited reaction kinetics. In this work, an electrokinetically controlled DNA hybridization microfluidic chip will be introduced. The electrokinetic delivery technique provides the ability to dispense controlled samples of nanoliter volumes directly to the hybridization array (thereby increasing the reaction rate) and rapidly remove nonspecific adsorption, enabling the hybridization, washing, and scanning procedures to be conducted simultaneously. The result is that all processes from sample dispensing to hybridization detection can be completed in as little as 5 min. The chip also demonstrates an efficient hybridization scheme in which the probe saturation level is reached very rapidly as the targets are transported over the immobilized probe site enabling quantitative analysis of the sample concentration. Detection levels as low as 50 pM have been recorded using an epifluorescence microscope.

Adsorption↗

Microfluidic devices fabricated in poly(methyl methacrylate) using hot-embossing with integrated sampling capillary and fiber optics for fluorescence detection.

High-aspect-ratio microstructures have been prepared using hot-embossing techniques in poly(methyl methacrylate) (PMMA) from Ni-based molding dies prepared using LIGA (Lithographie, Galvanoformung, Abformung). Due to the small amount of mask undercutting associated with X-ray lithography and the high energy X-ray beam used during photoresist patterning, deep structures with sharp and smooth sidewalls have been prepared. The Ni-electroforms produced devices with minimal replication errors using hot-embossing at a turn around time of approximately 5 min per device. In addition, several different polymers (with different glass transition temperatures) could be effectively molded with these Ni-electroforms and many devices (>300) molded with the same master without any noticeable degradation. The PMMA devices consisted of deep and narrow channels for insertion of a capillary for the automated electrokinetic loading of sample into the microfluidic device and also, a pair of optical fibers for shuttling laser light to the detection zone and collecting the resulting emission for fluorescence analysis. Electrophoretic separations of double-stranded DNA ladders Phi X174 digested with Hae III) were performed with fluorescence detection accomplished using near-IR excitation. It was found that the narrow width of the channels did not contribute significantly to electrophoretic zone broadening and the plate numbers generated in the extended length separation channel allowed sorting of the 271/281 base pair fragments associated with this sizing ladder when electrophoresed in methylcellulose entangled polymer solutions. The dual fiber detector produced sub-attomole detection limits with the entire detector, including laser source, electronics and photon transducer, situated in a single box measuring 3'' x 10" x 14".

Dinitrobenzenes↗