Search PubMed⌕ Search

Biomedical subjects

Xu Y Jin

Publications and source records attributed to Xu Y Jin.

2 recordsLinked to original sources

Circulatory support for long-term treatment of heart failure: experience with an intraventricular continuous flow pump.

BACKGROUND: A lifetime mechanical solution for advanced heart failure must be reliable, with a low risk of life-threatening complications. After extensive laboratory testing, we began clinical trials with an axial flow pump for long-term treatment of New York Heart Association class IV, transplant-ineligible patients. METHODS AND RESULTS: The Jarvik 2000 is a continuous flow device that is implanted in the apex of the left ventricle with offloading to the descending thoracic aorta. Skull-based percutaneous power delivery was derived from cochlear implant technology. We used this system in 4 patients with end-stage dilated cardiomyopathy. Exercise capacity, quality of life, device parameters, and native heart function were monitored serially. One patient died from right heart failure at 3 months. The other patients were discharged from hospital between 3 and 8 weeks postoperatively and are currently New York Heart Association I or II. Follow-up lasted between 9 and 20 months. There has been no device failure or hemolysis. Native heart function and quality of life were markedly improved. CONCLUSIONS: The Jarvik 2000 is a true assist (rather than replacement) device that functions synergistically with the native left ventricle and provides excellent quality of life. Adverse events are infrequent. This blood pump may provide a mechanical solution for end-stage heart failure in the community.

Adrenergic beta-Antagonists↗

Do stentless valves make a difference?

Stentless glutaraldehyde-preserved bioprosthetic valves for the aortic position were introduced into clinical practice in 1988. Their introduction coincided with the publication of several long-term observational studies of aortic homografts, which showed superior freedom from structural valve damage compared to the first generation stented porcine bioprosthesis. There followed 10 years of intensive investigation into the haemodynamic characteristics of stentless valves. These studies have demonstrated superior haemodynamic features in terms of transvalvular pressure gradients, effective orifice area, and more complete regression of left ventricular hypertrophy. Despite these advantages, stentless valves have yet to be adopted widely. This review seeks to explain this paradox.

Aortic Valve Stenosis↗