Search PubMed⌕ Search

Biomedical subjects

Xiuhan Yang

Publications and source records attributed to Xiuhan Yang.

5 recordsLinked to original sources

Indirect laser-induced fluorescence detection of diuretics separated by capillary electrophoresis.

Indirect LIF detection was applied to the detection of four acidic diuretics separated by CZE. Semiconductor laser was employed to provide the stable excitation of 473 nm. With an optimized electrophoretic buffer system which contained 5 mM of triethylamine, 0.1 microM of fluorescein, and 5% of n-butanol, fast separation of four diuretics (ethacrynic acid, chlorthalidone, bendroflumethiazide, and bumetanide) can be performed within 3 min with the detection limits of 0.2-2 microg/mL. The impacts of buffer components including the concentrations of the electrolytes, fluorescence probe, and the organic additives were demonstrated. The method was applied for the detection of diuretics in urine. As an alternative way for the fast analysis of diuretics, this indirect detection method provided the technical support for future microchip performances, in which diuretics may be detected in the microchip by the common LIF detector without derivatization.

Buffers↗

Preparation of the capillary-based microchips for solid phase extraction by using the monolithic frits prepared by UV-initiated polymerization.

A microfluidic solid phase extraction (SPE) array for sample enrichment was prepared by a simple method, a hot embossing technique. Five fused-silica capillaries (250 microm i.d., 380 microm o.d.) were partly embedded parallel in a polymethyl methacrylate (PMMA) microchip to serve as the extraction channels. Within each of the channels, a 2-mm-long monolithic porous polymer was prepared by in-situ photoinitiated polymerization. This then acted as the frit for packing of the extraction materials (octadecylsilica beads, ODS). By defining the light-exposure window on the channels, one can easily control the length and location of the polymer frits and the ODS beads can be packed at the desired location. With this method, solid phase extraction channels for microfluidic use can be easily prepared without complex fabrication of microstructures. Several SPE channels can be conveniently made in one microchip since the frits can be prepared in different channels through one polymerization; packing of the different channels can also be performed simultaneously. With the use of dilute ephedrine solutions, the sample loading capacity, linearity, and reproducibility were characterized. Coupled with the fast capillary electrophoresis separation, this microchip SPE array was applied for the detection of ephedrines in human urine.

Calibration↗

A novel miniaturized flame ionization detector for portable gas chromatography.

A novel miniaturized flame ionization detector (FID) operated by battery, which can be used as a detector in portable gas chromatography (GC) is devised and manufactured. It is characterized by the structure of building blocks, small volume, low energy consumption, and needing only two gases, which can be used for detection of hydrocarbons in portable GC. The miniaturized detector mainly includes a porous metallic diffuser plate, bugle-figuration collector, quartz capillary flame tip, and self-heated system. The miniaturized FID is easy to fabricate and assemble because of its structure of building blocks. The FID response is linear over six orders of magnitude and the detection limit of 0.518 ng for benzene, 0.430 ng for n-dodecane, 0.473 ng for naphthalene, and 0.509 ng for n-tetradecane.

Alkanes↗

Comprehensive two-dimensional separations based on capillary high-performance liquid chromatography and microchip electrophoresis.

A novel comprehensive two-dimensional (2-D) separation system coupling capillary high-performance liquid chromatography (cHPLC) with microchip electrophoresis (chip CE) is demonstrated. Reversed-phase cHPLC was used as the first dimension, and chip CE acted as the second dimension to perform fast sample transfers and separations. A valve-free gating interface was devised simply by inserting the outlet-end of LC column into the cross-channel on a specially designed chip. A home-made confocal laser-induced fluorescence detector was used to perform on-chip high-sensitive detection. The cHPLC effluents were continuously delivered to the chip and pinched injections of the effluents every 20 seconds were employed for chip CE separation. Gradient elution of cHPLC was carried out to obtain the high-efficiency separation. Free-zone electrophoresis was performed with triethylamine buffer to achieve high-speed separation and prevent sample adsorption. Such a simple-made comprehensive system was proved to be effective. The relative standard deviations for migration time and peak height of rhodamine B in 150 sample transfers were 3.2% and 9.8%, respectively. Peptides of the fluorescein isothiocyanate (FITC)-labeled tryptic digests of bovine serum albumin were fairly resolved and detected with this comprehensive 2-D system.

Animals↗

Gas chromatography-mass spectrometry method for determination of phenylalanine and tyrosine in neonatal blood spots.

In this paper we developed a simple, rapid and sensitive method for the quantitative analysis of phenylalanine (Phe) and tyrosine (Tyr) in dried blood spots of newborns by gas chromatography-mass spectrometry (GC-MS). Phe and Tyr in blood samples were reacted with N-methyl-N-(tert.-butyldimethylsilyl)trifluoroacetamide at 120 degrees C for 30 min and their corresponding single derivatives were obtained. Phe and Tyr were determined by measurement of their derivatives by GC-MS in the selected ion monitoring mode. Contents of Phe and Tyr in blood spots were calculated by external standard method. The ratio of Phe to Tyr was used for neonatal screening for phenylketonuria. The present method only took a few minutes to perform and required minimal sample preparation. In addition it provided low detection limits of 1.2 micromol l(-1) for Phe and 1.6 micromol l(-1)for Tyr.

Gas Chromatography-Mass Spectrometry↗