Search PubMed⌕ Search

Biomedical subjects

Xiaochuan Pan

Publications and source records attributed to Xiaochuan Pan.

At least 37 records · Page 2Linked to original sources

A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.

A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region of interest within the image in circular cone-beam and fan-beam cases. Recently, we have developed a 3D FBP-based algorithm for image reconstruction on PI-line segments in a helical cone-beam scan. In this work, we demonstrated that the 3D FBP-based algorithm indeed provided a rather general formulation for image reconstruction from divergent projections (such as cone-beam and fan-beam projections). On the basis of this formulation we derived new approximate or exact algorithms for image reconstruction in circular cone-beam or fan-beam scans, which can be interpreted as special cases of the helical scan. Existing algorithms corresponding to the derived algorithms were identified. We also performed a preliminary numerical study to verify our theoretical results in each of the cases. The results in the work can readily be generalized to other non-circular trajectories.

Algorithms↗

Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT.

Recently, we have derived a general formula for image reconstruction from helical cone-beam projections. Based upon this formula, we have also developed an exact algorithm for image reconstruction on PI-line segments from minimum data within the Tam-Danielsson window. This previous algorithm can be referred to as a backprojection-filtration algorithm because it reconstructs an image by first backprojection of the data derivatives and then filtration of the backprojections on PI-line segments. In this work, we propose an alternative algorithm, which reconstructs an image by first filtering the modified data along the cone-beam projections of the PI-lines onto the detector plane and then backprojecting the filtered data onto PI-line segments. Therefore, we refer to this alternative algorithm as the filtered-backprojection algorithm. A preliminary computer-simulation study was performed for validating and demonstrating this new algorithm. Furthermore, we derive a practically useful expression to accurately compute the derivative of the data function for image reconstruction. The proposed filtered-backprojection algorithm can reconstruct the image within any selected ROI inside the helix and thus can handle naturally the long object problem and the super-short scan problem. It can also be generalized to reconstruct images from data acquired with other scanning configurations such as the helical scan with a varying pitch.

Algorithms↗

Impact of polychromatic x-ray sources on helical, cone-beam computed tomography and dual-energy methods.

Recently, there has been much work devoted to developing accurate and efficient algorithms for image reconstruction in helical, cone-beam computed tomography (CT). Little attention, however, has been directed to the effect of physical factors on helical, cone-beam CT image reconstruction. This work investigates the effect of polychromatic x-rays on image reconstruction in helical, cone-beam computed tomography. A pre-reconstruction dual-energy technique is developed to reduce beam-hardening artefacts and enhance contrast in soft tissue.

Algorithms↗

Partial volume and aliasing artefacts in helical cone-beam CT.

A generalization of the quasi-exact algorithms of Kudo et al (2000 IEEE Trans. Med. Imaging 19 902-21) is developed that allows for data acquisition in a 'practical' frame for clinical diagnostic helical, cone-beam computed tomography (CT). The algorithm is investigated using data that model nonlinear partial volume averaging. This investigation leads to an understanding of aliasing artefacts in helical, cone-beam CT image reconstruction. An ad hoc scheme is proposed to mitigate artefacts due to the nonlinear partial volume and aliasing artefacts.

Algorithms↗

An exact Fourier rebinning algorithm for 3D PET imaging using panel detectors.

Abstract We present an exact Fourier-based algorithm for rebinning 3D data generated by a stationary dual-panel PET system to obtain direct slices for subsequent slice-by-slice reconstruction. The algorithm is computationally efficient and can greatly reduce the problem dimensionality and computation complexity of the reconstruction task. By conducting computer simulation studies in which the effects of scatter, randoms, detector response functions and attenuation correction are not considered, we demonstrate that direct slices generated by the proposed algorithm are quantitatively accurate and exhibit substantially better noise characteristics than the original direct slices. However, image artefacts, occurring at axial intensity discontinuities and in regions close to the axial axis, can be observed. With preliminary supporting evidence, we stipulate that these artefacts are due to errors in discrete implementations of partial derivatives of the 3D data. Although general weightings can be used in the proposed rebinning algorithm, in this work we only study the use of uniform weightings and the resulting direct slices exhibit non-uniform noise distributions, with the central slices being less noisy. In future studies, by using general weightings to reduce contributions of the data that are acquired at large oblique angles, we expect that more uniform noise distributions can be achieved, and axial blurring due to parallax errors can be reduced, at the cost of overall image variance.

Algorithms↗

Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT.

The development of accurate and efficient algorithms for image reconstruction from helical cone-beam projections remains a subject of active research. In the last few years, a number of quasi-exact and exact algorithms have been developed. Among them, the Katsevich algorithms are of filtered backprojection type and thus possess computational advantages over other existing exact algorithms. In this work, we propose an alternative approach to reconstructing exactly an image from helical cone-beam projections. Based on this approach, we develop an algorithm that requires less data than do the existing quasi-exact and exact algorithms, including the Katsevich algorithms. Our proposed algorithm is also of filtered backprojection type with one-dimensional filtering performed along a PI-line in image space. Therefore, it is (at least) computationally as efficient as the Katsevich algorithms. We have performed a preliminary numerical study to demonstrate and validate the proposed algorithm using computer-simulation data. The implication of the proposed approach and algorithm appears to be significant in that they can naturally address the long object problem as well as the super-short scan problem and, most importantly, in that they provide the opportunity to reconstruct images within any selected region of interest from minimum data, allowing the use of detector with a reduced size, the selection of a minimum number of rotation angles and thus the reduction of radiation dose delivered to the imaged subject.

Algorithms↗

Analytic image reconstruction in local phase-contrast tomography.

Phase-contrast tomography is a non-interferometric imaging technique for reconstructing the refractive index distribution of a weakly absorbing object from a set of tomographic projection measurements. In many practical situations, the spatial resolution of the reconstructed image can be increased by minimizing the field of view (FOV) of the imaging system. When the object of interest is larger than the FOV, the measured projections are truncated and one is faced with a local tomography reconstruction problem. In this work, we analytically and numerically investigate the problem of reconstructing tomographic images from truncated phase-contrast projection data. A simple backprojection algorithm for reconstructing object discontinuities from truncated phase-contrast projection data is proposed and investigated that involves no explicit filtering of the projection data. We also investigate the use of the filtered backprojection algorithm and a local tomography reconstruction algorithm developed for absorption CT. These reconstruction algorithms are implemented and numerically investigated to corroborate our theoretical assertions.

Algorithms↗

Sampling and aliasing consequences of quarter-detector offset use in helical CT.

In this paper, the sampling and aliasing consequences of employing a quarter-detector-offset (QDO) in helical computed tomography (CT) are analyzed. QDO is often used in conventional CT to reduce in-plane aliasing by eliminating data redundancies to improve radial sampling. In helical CT, these same redundancies are exploited to improve longitudinal sampling and so it might seem ill-advised to employ QDO. The relative merit of the two geometries for helical CT is studied by conducting a multidimensional sampling analysis of projection-space sampling as well as a Fourier crosstalk analysis of crosstalk among the object's Fourier basis components. Both a standard fanbeam helical CT geometry and a hypothetical parallel-beam CT geometry, which helps illuminate the more complicated fanbeam results, are analyzed. Using the sampling analysis, it was found that the use of QDO leads to very different spectral tiling than arise when not using QDO. However, due to the shape of the essential support of the projection data spectra that arises in practice, both configurations lead to very similar or identical amounts of spectral overlap. This perspective also predicts the spatially variant longitudinal aliasing that has been observed in helical CT. The crosstalk results were consistent with those of the multidimensional sampling analysis. Thus, from the standpoint of aliasing and crosstalk, no compelling difference is found between the two geometries.

Algorithms↗

Reduction of computed tomography metal artifacts due to the Fletcher-Suit applicator in gynecology patients receiving intracavitary brachytherapy.

PURPOSE: To evaluate a method of reducing computed tomography (CT) metal artifacts due to the Fletcher-Suit applicator. METHODS AND MATERIALS: We apply a projection-interpolation algorithm to CT images containing artifacts from the brachytherapy applicator. Regions of projection data containing the applicator are interpolated, removing the metal from the projections. A new image is then reconstructed, and a pixel-by-pixel correction factor applied to the original image to reduce the severity of metal artifacts. This technique is applied to phantom and patient image data. RESULTS: Qualitative and quantitative comparisons of images produced before and after projection-interpolation show a significant reduction in metal artifacts. In patient images containing the tandem alone, this method almost completely eliminated the artifact. In slices containing both tandem and colpostats, the algorithm reduced artifacts but did not completely eliminate them. CONCLUSIONS: The projection-interpolation method can be used to reduce the severity of metal artifacts caused by the Fletcher-Suit applicator.

Algorithms↗

An improved reconstruction algorithm for 3-D diffraction tomography using spherical-wave sources.

Diffraction tomography (DT) is an inversion technique that reconstructs the refractive index distribution of a weakly scattering object. In this paper, a novel reconstruction algorithm for three-dimensional diffraction tomography employing spherical-wave sources is mathematically developed and numerically implemented. Our algorithm is numerically robust and is much more computationally efficient than the conventional filtered backpropagation algorithm. Our previously developed algorithm for DT using plane-wave sources is contained as a special case.

Computer Simulation↗

Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography.

In computed tomography (CT), the fan-beam filtered backprojection (FFBP) algorithm is used widely for image reconstruction. It is known that the FFBP algorithm can significantly amplify data noise and aliasing artifacts in situations where the focal lengths are comparable to or smaller than the size of the field of measurement (FOM). In this work, we propose an algorithm that is less susceptible to data noise, aliasing, and other data inconsistencies than is the FFBP algorithm while retaining the favorable resolution properties of the FFBP algorithm. In an attempt to evaluate the noise properties in reconstructed images, we derive analytic expressions for image variances obtained by use of the FFBP algorithm and the proposed algorithm. Computer simulation studies are conducted for quantitative evaluation of the spatial resolution and noise properties of images reconstructed by use of the algorithms. Numerical results of these studies confirm the favorable spatial resolution and noise properties of the proposed algorithm and verify the validity of the theoretically predicted image variances. The proposed algorithm and the derived analytic expressions for image variances can have practical implications for both estimation and detection/classification tasks making use of CT images, and they can readily be generalized to other fan-beam geometries.

Algorithms↗

Half-scan fan-beam computed tomography with improved noise and resolution properties.

Half-scan strategy can be used for reducing scanning time and radiation dose delivered to the patient in fan-beam computed tomography (CT). In helical CT, the data weighting/interpolation functions are often devised based upon half-scan configurations. The half-scan fan-beam filtered backprojection (FFBP) algorithm is generally used for image reconstruction from half-scan data. It can, however, be susceptible to sample aliasing and data noise for configurations with short focal lengths and/or large fan-angles, leading to nonuniform resolution and noise properties in reconstructed images. Uniform resolution and noise properties are generally desired because they may lead to an increased utility of reconstructed images in estimation and/or detection/classification tasks. In this work, we propose an algorithm for reconstruction of images with uniform noise and resolution properties in half-scan CT. In an attempt to evaluate the image-noise properties, we derive analytic expressions for image variances obtained by use of the half-scan algorithms. We also perform numerical studies to assess quantitatively the resolution and noise properties of the algorithms. The results in these studies confirm that the proposed algorithm yields images with more uniform spatial resolution and with lower and more uniform noise levels than does the half-scan FFBP algorithm. Empirical results obtained in noise studies also verify the validity of the derived expressions for image variances. The proposed algorithm would be particularly useful for image reconstruction from data acquired by use of configurations with short focal lengths and large field of measurement, which may be encountered in compact micro-CT and radiation therapeutic CT applications. The analytic results of the image-noise properties can be used for image-quality assessment in detection/classification tasks by use of model-observers.

Algorithms↗

A preliminary investigation of local tomography for megavoltage CT imaging.

We investigate the problem of reconstructing a two-dimensional (2-D) cross-sectional image of a tumor volume from a set of truncated MV projections that are produced by radiation therapy treatment beams. Our proposed approach is conceptually distinct from previously investigated approaches in that it utilizes a noniterative local tomography reconstruction algorithm. A local tomography reconstruction algorithm is implemented and systematically investigated using several sets of simulated and experimental MV projection data. We demonstrate that the conventional (nonlocal) filtered backprojection reconstruction algorithm cannot, in general, accurately reconstruct the edges and boundaries of low-contrast features from truncated MV projection data. We demonstrate that the local tomography algorithm is not adversely affected by projection truncation and can reconstruct accurately the boundaries of low-contrast structures within the region of interest from truncated MV projections.

Algorithms↗

[Time-series analysis on the relationship between air pollution and daily mortality in Beijing].

To quantitively evaluate the associations between ambient air pollutant and daily mortality of Beijing and to supply the scientific bases for formulating control measures. Air pollutants including CO, SO2, NOx, TSP, PM10. time series analysis Poisson regression was used to evaluate the relationship between cause-specific deaths and air pollutant, considering the potential confounding factors such as seasonal and long-term patterns, meteorological factors (air temperature, air humidity), as well as adjusting the influence of flu epidemics in winter of 1998. The results showed that in single-factor Poisson regression analysis, there is a significant positive correlation between the four pollutants and daily mortality except for the relationship between TSP and coronary heart disease deaths. In multi-factor Poisson regression analysis, when SO2 increase in 100 micrograms/m3, respiratory deaths, cardiovascular and cerebro-vascular deaths, coronary heart disease deaths and chronic obstructive pulmonary deaths increased by 4.21%, 3.97%, 10.68%, 19.22% respectively. Meanwhile, each 100 micrograms/m3 increase in TSP associated with 3.19% increase in the respiratory deaths and 0.62% increase in the cardiovascular and cerebrovascular deaths. It is suggested that air pollution is a risk factor for health and an increase of air pollution level might lead to a raise in daily mortality.

Air Pollutants↗

Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT).

In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal.

Artifacts↗

Short-scan SPECT imaging with non-uniform attenuation and 3D distance-dependent spatial resolution.

Image quality and quantitative accuracy in single-photon emission computed tomography (SPECT) can be degraded by, e.g., the effects of photon attenuation and finite spatial resolution. It is generally considered that adequate compensation for such effects on SPECT images requires data acquired over 2 pi. Recently, using the existing consistency condition on the data function, Noo and Wagner (2001 Inverse Problems 17 1357-72) have shown analytically that data acquired over only pi can be used to correct completely for the effect of uniform attenuation in SPECT. It remains unknown, however, whether data acquired only over pi in SPECT with non-uniform attenuation and/or 3D distance-dependent spatial resolution (DDSR) contain complete information for accurate image reconstruction. In this work, we develop a heuristic perspective, which is referred to as the potato peeler perspective to show conceptually that data in SPECT with non-uniform attenuation and/or 3D DDSR acquired over 2 pi contain redundant information and that such information can be used to reduce the scanning angle in SPECT. Specifically, we show heuristically that, in SPECT with only non-uniform attenuation, the scanning angle can be reduced from 2 pi to pi and that, in SPECT with both non-uniform attenuation and DDSR with a physically realistic form, the scanning angle can be reduced from 2 pi to pi in a practical sense. We conduct computer simulation studies, and the results from these studies corroborate the observations obtained based upon the heuristic potato peeler perspective.

Algorithms↗

On a limited-view reconstruction problem in diffraction tomography.

Diffraction tomography (DT) is an inversion technique that reconstructs the refractive index distribution of a scattering object. We previously demonstrated that by exploiting the redundant information in the DT data, the scattering object could be exactly reconstructed using measurements taken over the angular range [0, phimin], where pi < phimin < or = 3pi/2. In this paper, we reveal a relationship between the maximum scanning angle and image resolution when a filtered backpropagation (FBPP) reconstruction algorithm is employed for image reconstruction. Based on this observation, we develop short-scan FBPP algorithms that reconstruct a low-pass filtered scattering object from measurements acquired over the angular range [0, phi(c)], where phi(c) < phimin.

Acoustics↗

Anti-aliasing weighting functions for single-slice helical CT.

Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can, for scans performed at pitch 1 or lower, essentially eliminate this longitudinal aliasing by exploiting a generalization of the Whittaker-Shannon sampling theorem whose conditions are satisfied by the interlaced pairs of direct and complementary longitudinal samples. However, the algorithm is computationally intensive and cannot be pipelined. In this paper, we address this shortcoming by deriving two spatial-domain, projection-data weighting functions that approximate the application of the Fourier-based approach, and preserve its aliasing suppression properties to some degree, while allowing for a pipelined implementation. The first approach, which we call simply 180AA, for anti-aliasing, is a direct spatial-domain approximation of the 180FT approach. The second approach, which we call 180BSP, is based on an approximate generalized interpolation approach making use of B-splines. Studies of aliasing and resolution properties in reconstructions from simulated data indicate that while the 180AA and 180BSP approaches do not perfectly replicate the favorable aliasing suppression and resolution properties of the 180FT approach, they do represent an improvement over the clinically standard 180LI approach on these fronts.

Computer Simulation↗