Search PubMed⌕ Search

Biomedical subjects

Xianmin Jiang

Publications and source records attributed to Xianmin Jiang.

3 recordsLinked to original sources

Dynamic hollow fiber-supported headspace liquid-phase microextraction.

With the increasing concern over deteriorating environmental quality, the analysis of organic pollutants in air, water, and soil has become critically important. The development of simple, efficient, and inexpensive analytical sample pretreatment is crucial for monitoring and evaluating the environment. In this work, a dynamic hollow-fiber supported headspace liquid-phase microextraction (DHF-HS-LPME) approach was developed. In dynamic LPME, the extracting solvent is held within a hollow fiber, affixed to a syringe needle and immersed in the sample solution, and is moved to-and-fro by using a programmable syringe pump. The movement facilitates mass transfer from the sample to the solvent. Here, a similar approach was adopted, except that extraction was from the headspace rather than by direct immersion. Analysis of the extract was carried out by gas chromatography-mass spectrometry. The effect of sampling temperature, water, salt, dwelling time were investigated. Results indicated that this novel headspace microextraction method gave good analyte-enrichment factors, linear range, limits of detection and repeatability, all of which were evaluated by extracting PAHs from soil samples. This technique represents an inexpensive, convenient, fast and simple sample preparation of this class of semi-volatile organic compounds.

Chromatography, Liquid↗

Dynamic liquid-liquid-liquid microextraction with automated movement of the acceptor phase.

A new dynamic liquid-liquid-liquid microextraction procedure, with the automated movement of acceptor phase (LLLME/AMAP) to facilitate mass transfer, was developed in this study. Four compounds, 3-nitrophenol, 4-nitrophenol, 3,4-dinitrophenol, and 2,4-dichlorophenol, were used as model compounds to be preconcentrated from water samples. The extraction involved filling a 2-cm length of hollow fiber with 4 muL of acceptor solution using a conventional microsyringe, followed by impregnation of the pores of the fiber wall with 1-octanol. The fiber was then immersed in 4 mL of aqueous sample solution. The analytes in the sample solution were extracted into the organic solvent and then back-extracted into the acceptor solution. During extraction, the acceptor phase was repeatedly moved in and out of the hollow fiber channel and the syringe controlled by a syringe pump. Separation and quantitative analyses were then performed by using high-performance liquid chromatography. The results indicated that up to 400-fold enrichment of the analytes could be obtained under the optimized conditions. The enrichment factors were two times those of static liquid-liquid-liquid microextraction. Good repeatabilities (RSD values below 9.30%) were obtained. The calibration linear range was from 10 to 1000 ng/mL with the square of the correlation coefficient (r2) >0.9916. Detection limits were in the range of 0.45-0.98 ng/mL. In addition, as compared with the previously reported dynamic three-phase microextraction in which there was no relative movement between the acceptor and the organic phase (which is not conducive to effective mass transfer), this new method shows much higher extraction efficiency. All these results suggest that this new dynamic LLLME/AMAP technique could be a better alternative to the previous LLLME for the extraction of analytes from aqueous samples.

Journal Article↗

Solvent bar microextraction.

In this work, a new and simple microextraction method termed solvent bar microextraction (SBME) was developed. In this method, the organic extractant solvent (1-octanol) was confined within a short length of a hollow fiber membrane (sealed at both ends) that was placed in a stirred aqueous sample solution. Tumbling of the extraction device within the sample solution facilitated extraction. Pentachlorobenzene (PCB) and hexachlorobenzene (HCB) were used as model compounds to investigate the extraction performance. Analysis was carried out by gas chromatography/electron capture detection. This new method provided very high enrichment (approximately 110-fold for PCB and approximately 70-fold for HCB) in 10 min and good reproducibility (<4%, n = 6). Since the hollow fiber membrane was sealed, it could be used for extraction from "dirty" samples, such soil slurries. This novel microextraction method was compared with single-drop microextraction and static hollow fiber membrane microextraction in which the extractant solvent was also held within a hollow fiber but with the latter fixed to a syringe needle (i.e., there was no tumbling effect). Comparison between SBME and conventional solid-phase microextraction in a soil slurry sample was also investigated.

Journal Article↗