Search PubMed⌕ Search

Biomedical subjects

X Shi

Publications and source records attributed to X Shi.

At least 433 records · Page 24Linked to original sources

A diminished aortic-cardiac reflex during hypotension in aerobically fit young men.

We compared the aortic-cardiac baroreflex sensitivity in eight average fit (AF: VO2max = 44.7 +/- 1.3 ml.kg-1 x min-1) and seven high fit (HF: VO2max = 64.1 +/- 1.7 ml.min-1 x kg-1) healthy young men during hypotension elicited by steady state sodium nitroprusside (SN) infusion. During SN mean arterial pressure (MAP) was similarly decreased in AF (-12.6 +/- 1.0 mm Hg) and HF (-12.1 +/- 1.1 mm Hg). However, the increases in heart rate (HR) were less (P < 0.023) in HF (15 +/- 3 bpm) than AF (25 +/- 1 bpm). When sustained neck suction (NS, -22 +/- 1 torr in AF and -20 +/- 1 torr in HF, P > 0.05) was applied to counteract the decreased carotid sinus transmural pressure during SN, thereby isolating the aortic baroreceptors, the increased HR remained less (P < 0.021) in HF (8 +/- 2 bpm) than AF (16 +/- 2 bpm). During both SN infusion and SN+NS, the calculated gains (i.e., delta HR/delta MAP) were significantly greater in AF (2.1 +/- 0.3 and 1.3 +/- 0.2 bpm.mm Hg-1) than HF (1.2 +/- 0.2 and 0.6 +/- 0.2 bpm.mm Hg-1). However, the estimated carotid-cardiac baroreflex sensitivity (i.e., the gain difference between the stage SN and SN + NS) was not different between AF (0.7 +/- 0.2 bpm.mm Hg-1) and HF (0.6 +/- 0.1 bpm.mm Hg-1). These data indicated that the aortic-cardiac baroreflex sensitivity during hypotension was significantly diminished with endurance exercise training.

Adult↗

An analysis of the correlation between angiographic and clinical findings in cerebral arteriovenous malformations.

One hundred and sixty-seven cases of cerebral arteriovenous malformations (AVMs) confirmed by digital subtract angiography (DSA) and surgery were analyzed to find the correlation between clinical and angiographic findings with regard to sex, age, size of angioma, and number of drainage veins and feeding arteries. Statistical analysis showed that the risk of hemorrhage was highest in small AVMs with only one drainage vein, and decreased with increases of volume and number of AVMs. Statistics also demonstrated that small AVMs usually have one drainage vein and so have a high risk of hemorrhage.

Adolescent↗

Effects of dynamic exercise on cardiovascular regulation during lower body negative pressure.

The purpose of this study was to compare the cardiovascular control mechanisms that defend arterial blood pressure against blood pooling between rest and moderate dynamic exercise. We studied ten physically active men during rest and five 12-min graded supine cycle ergometer exercise bouts with and without application of LBNP in 25 degrees C and 35 degrees C. Exercise intensities were 10, 50, and 100 watts (W), each for 4 min, and LBNP was applied at 0 (control), -20, -40, and -60 mm Hg in 25 degrees C and -40 mm Hg in 35 degrees C. At rest, cardiac stroke volume (SV) decreased from 120 +/- 5 ml during control to 94 +/- 6, 67 +/- 5 and 49 +/- 3 ml during -20, -40, and -60 mm Hg LBNP, respectively, and to 55 +/- 3 ml during -40 mm Hg at 35 degrees C. Exercise elevated SV toward the control level during LBNP due to muscle pumping action. Heart rate (HR) did not increase significantly during application of LBNP until SV decreased by 20-25 ml during LBNP, both during rest and exercise. The magnitude of HR increase per decrease in SV, once an increase in HR occurred, was similar between rest and exercise, regardless of exercise intensity. The change in total peripheral resistance (TPR) with respect to SV was linear, confirming that peripheral vascular adjustments were proportional to changes in the heart's preload. The slopes of the TPR-SV relation were similar during rest and exercise, although shifted to the left with increasing exercise intensity.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Hormonal responses during orthostasis following 4 hours of head-down tilt.

The purpose of this investigation was to test the hypothesis that endurance exercise trained (ET) subjects would demonstrate a greater reduction in orthostatic tolerance as compared to untrained (UT) subjects following prior exposure to -6 degrees head-down tilt (HDT) because vasoactive hormone and enzyme responses to head-up tilt (HUT) would be decreased following HDT so as to predispose ET subjects to orthostatic intolerance. Six ET subjects (VO2peak = 4.52 +/- 0.20 L/min) were matched for age and height with six UT subjects (VO2peak = 3.26 +/- 0.22 L/min; p < 0.01). After 30 min of supine rest, subjects were exposed to 30 min of head-up tilt (HUT) at 70 degrees, then on a separate occasion, 4 h of HDT (-6 degrees) followed by 30 min of HUT. The HUT involved passive standing for 30 min or until subjects became presyncopal. Blood sampled from the antecubital vein at min 1, 15, and 30, or at presyncope was analyzed for atrial natriuretic peptide (ANP), aldosterone (PA), arginine vasopressin (AVP), plasma renin activity (PRA), and norepinephrine (NE), while BP and HR were continuously monitored. All subjects tolerating 30 min of HUT, after either condition, had significantly increased (p < 0.05) levels of PRA at the 30th min. Following 4 h of HDT, five of six UT subjects and only one of six ET subjects endured 30 min of HUT. The most marked difference during HUT after prior exposure to HDT was a significant increase in AVP (p < 0.05) at the onset of HUT observed only for the UT subjects.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Comparative laboratory evaluation of two new toothbrushes regarding interproximal access efficacy.

The Colgate Precision toothbrush and the Crest Complete toothbrush were compared using a laboratory device designed to simulate clinical toothbrushing motions and pressures, allowing measurement of interproximal access efficacy. The toothbrushing time was sixty seconds for each vertical or horizontal toothbrushing motion and for each of the three brushing weights tested (250, 500 or 750g). Interproximal access efficacy was determined by measuring the maximum width of the brushing stroke on pressure-sensitive paper placed around simulated anterior or posterior-shaped teeth. Twenty-four toothbrushes of each design were evaluated for each toothbrushing motion, tooth shape and toothbrushing weight for a total of 576 measurements. Using vertical toothbrushing motions the Colgate Precision toothbrush had significantly higher (p < 0.01) interproximal access efficacy mean values, compared to the Crest Complete toothbrush on both anterior and posterior tooth shapes and at each of the brushing weights tested. Using the horizontal toothbrushing motion on anterior-shaped teeth, the interproximal access efficacy for the Colgate Precision toothbrush was significantly greater (p < 0.05) than the Crest Complete toothbrush at 750g of brushing weight. With horizontal toothbrushing across posterior-shaped teeth, interproximal access efficacy values for the Colgate Precision toothbrush were significantly greater (p < 0.01) than the Crest Complete toothbrush at the 250, 500 and 750g brushing weights tested.

Analysis of Variance↗

Generation of free radicals from lipid hydroperoxides by Ni2+ in the presence of oligopeptides.

The generation of free radicals from lipid hydroperoxides by Ni2+ in the presence of several oligopeptides was investigated by electron spin resonance (ESR) utilizing 5,5-dimethyl-1-pyrroline N-oxide (DMPO) as a spin trap. Incubation of Ni2+ with cumene hydroperoxide or t-butyl hydroperoxide did not generate any detectable free radical. In the presence of glycylglycylhistidine (GlyGlyHis), however, Ni2+ generated cumene peroxyl (ROO.) radical from cumene hydroperoxide, with the free radical generation reaching its saturation level within about 3 min. The reaction was first order with respect to both cumene hydroperoxide and Ni2+. Similar results were obtained using t-butyl hydroperoxide, but the yield of t-butyl peroxyl radical generation was about 7-fold lower. Other histidine-containing oligopeptides such as beta-alanyl-L-histidine (carnosine), gamma-aminobutyryl-L-histidine (homocarnosine), and beta-alanyl-3-methyl-L-histidine (anserine) caused the generation of both cumene alkyl (R.) and cumene alkoxyl (RO.) radicals in the reaction of Ni2+ with cumene hydroperoxide. Similar results were obtained using t-butyl hydroperoxide. Glutathione also caused generation of R. and RO. radicals in the reaction of Ni2+ with cumene hydroperoxide but the yield was approximately 25-fold greater than that produced by the histidine-containing peptides, except GlyGlyHis. The ratio of DMPO/R. and DMPO/RO. produced with glutathione and cumene hydroperoxide was approximately 3:1. Essentially the same results were obtained using t-butyl hydroperoxide except that the ratio of DMPO/R. to DMPO/RO. was approximately 1:1. The free radical generation from cumene hydroperoxide reached its saturation level almost instantaneously while in the case of t-butyl hydroperoxide, the saturation level was reached in about 3 min. In the presence of oxidized glutathione, the Ni2+/cumene hydroperoxide system caused DMPO/.OH generation from DMPO without forming free hydroxyl radical. Since glutathione, carnosine, homocarnosine, and anserine are considered to be cellular antioxidants, the present work suggests that instead of protecting against oxidative damage, these oligopeptides may facilitate the Ni(2+)-mediated free radical generation and thus may participate in the mechanism(s) of Ni2+ toxicity and carcinogenicity.

Benzene Derivatives↗

Xanthine oxidase/hydrogen peroxide generates sulfur trioxide anion radical (SO3.-) from sulfite (SO3(2-)).

In the presence of hydrogen peroxide (H2O2), xanthine oxidase has been found to catalyze sulfur trioxide anion radical (SO3.-) formation from sulfite anion (SO3(2-)). The SO3.- radical was identified by ESR (electron spin resonance) spin trapping, utilizing 5,5-dimethyl-l-pyrroline-l-oxide (DMPO) as the spin trap. Inactivated xanthine oxidase does not catalyze SO3.- radical formation, implying a specific role for this enzyme. The initial rate of SO3.- radical formation increases linearly with xanthine oxidase concentration. Together, these observations indicate that the SO3.- generation occurs enzymatically. These results suggest a new property of xanthine oxidase and perhaps also a significant step in the mechanism of sulfite toxicity in cellular systems.

Electron Spin Resonance Spectroscopy↗

Superoxide-independent reduction of vanadate by rat liver microsomes/NAD(P)H: vanadate reductase activity.

It has been reported that vanadate-stimulated oxidation of NAD(P)H by microsomal systems can proceed anaerobically, in contrast to the general notion that the oxidation proceeds exclusively by an O(2-)-dependent free radical chain mechanism. The current study indicates that microsomal systems are endowed with a vanadate-reductase property, involving a NAD(P)H-dependent electron transport cytochrome P450 system. Our ESR measurements demonstrated the formation of a vanadium(IV) species in a mixture containing vanadate, rat liver microsomes, and NAD(P)H. This vanadium(IV) species was identified as the vanadyl ion (VO2+) by comparison with the ESR spectrum of VOSO4. The initial rate of vanadium(IV) formation depends linearly on the concentration of microsomes. The Michaelis-Menten constants were found to be: km = 1.25 mM and Vmax = 0.066 mumol (min)-1 (mg microsomes)-1, respectively. Pretreatment of the microsomes with carbon monoxide or K3Fe(CN)6 reduced vanadium(IV) generation, suggesting that the NAD(P)H-dependent electron transport cytochrome P450 system plays a significant role in the microsomal reduction of vanadate. Measurements under argon or in the presence of superoxide dismutase caused only minor (less than 10%) reductions in vanadium(IV) generation. The VO2+ species was also detected in NAD(P)H oxidation by fructose plus vanadate, a reaction known to proceed via an O(2-)-mediated chain mechanism. However, the amount of vanadium(IV) generated by this reaction was an order of magnitude smaller than that by the microsomal system and was inhibitable by superoxide dismutase, affirming the conclusion that the microsomal/NAD(P)H system is endowed with the (O(2-)-independent) vanadium(V) reductase property.

Anaerobiosis↗

Transplacental genotoxicity of triethylenemelamine, benzene, and vinblastine in mice.

Transplacental cytogenetic effects of triethylenemelamine (TEM), benzene, and vinblastine on maternal mice and their fetuses have been investigated using micronucleus and sister chromatid exchange (SCE) as genetic endpoints. CD-1 mice were treated on day 14 and 15 of gestation with TEM (0.125, 0.25, and 0.5 mg/kg), benzene (439,878, and 1,318 mg/kg), and vinblastine (0.5, 1, and 2 mg/kg) by intraperitoneal injection at 24 hr intervals, and sacrificed 40 hr after the first injection. Erythrocytic precursor cells in maternal bone marrow and fetal livers (2-4) from each pregnant mouse were used for the micronucleus and/or the SCE analyses. Significant dose-related increases in both micronuclei and SCE were found in maternal bone marrow and fetal liver following TEM treatment. Benzene at the highest dose (1,318 mg/kg) also caused a significant increase in micronuclei and SCE in both maternal bone marrow and fetal liver cells. The embryonic genotoxic effect of TEM was much higher than that of benzene for both genetic endpoints, and the frequency of micronuclei induced by benzene was higher in fetal liver than in maternal bone marrow cells. Vinblastine, a spindle poison, induced micronuclei but not SCE. Micronuclei induction by vinblastine was 7 fold greater in maternal bone marrow than in fetal liver cells. All three chemicals were cytotoxic in maternal bone marrow cells, but not in fetal liver cells except for TEM, which showed a weak cytotoxicity in fetal liver cells in the micronucleus assay. These results indicate that TEM, benzene, and vinblastine are transplacental genotoxicants in mice.

Animals↗

Modulation of bat wing venule contraction by transmural pressure changes.

We tested the hypothesis that the frequency and amplitude of spontaneous venular contractions in the bat wing could be modulated by changes in transmural pressure. In one series of experiments, venous pressure in the wing was elevated by pressurizing a box containing the body of the animal while the wing was exposed to atmospheric pressure. During this time, venular diameters were continuously recorded using intravital microscopic techniques while venular pressures were measured through servo-null micropipettes. In another series of experiments, single venular segments were dissected from the wing, cannulated, and pressurized in vitro. The results from both experimental protocols were qualitatively similar; alterations in venous pressure over a narrow range (+/- 5 cmH2O from control) produced substantial changes in contraction frequency and amplitude. The product of frequency and cross-sectional area was maximal over the venous pressure range between 10 and 15 cmH2O. Venules demonstrated a rate-sensitive component in their reaction to rapid pressure changes, because contraction bursts occurred immediately after positive pressure steps and quiescent periods often occurred after negative pressure steps. We conclude that venular vasomotion in the bat wing is modulated by intraluminal pressure and involves a bidirectional, rate-sensitive mechanism. In addition, comparisons with arteriolar vasomotion studies suggest that venules are more sensitive to luminal pressure changes than arterioles.

Animals↗

Enhanced generation of free radicals from phagocytes induced by mineral dusts.

Several studies have suggested that pulmonary toxicity to asbestos and silica may be mediated through oxidant-induced cell injury. We have reported recently that surface radicals associated with freshly fractured silica may be an important factor in cell injury and induction of pulmonary disease. Although the generation of oxygenated radicals in dust-cell interactions has been demonstrated, there are no data correlating the toxicity of a dust with the level of oxygen radical generation by the dust during its interaction with phagocytic cells. In the present study, we have investigated the in vitro generation of oxygen free radicals from human neutrophils and rat alveolar macrophages stimulated with freshly fractured silica, aged silica, amosite, crocidolite, chrysotile, and nontoxic dust, barite. Electron spin resonance (ESR) with the aid of a spin trap phenyl-N-tert-butyl nitrone (PBN) was used to measure the oxygen radicals generated during phagocytosis of the dusts. The relative toxicity index and ESR peak heights, on an equal surface area basis and normalized to barite as one, showed a direct relationship. The normalized toxicity indices and peak heights were: silica, 3.5 versus 2; chrysotile, 4 versus 2; crocidolite, 11 versus 8; and amosite, 26 versus 13. Addition of hydroxyl radical scavengers such as catalase, dimethyl sulfoxide, 1,3 dimethyl-2-thiourea (DMTU), sodium benzoate, and mannitol prevented the radical generation. Carmustine, a glutathione reductase-glutathione peroxidase inhibitor, caused a 5-fold increase in the radical generation. These results indicate that a nontoxic dust such as barite generates toxic oxygen radicals at a minimal level that can be quenched by the normal cellular defense system. For toxic dusts such as silica, amosite, chrysotile, and crocidolite, the potential for oxygen radical generation is enhanced by their surface properties, physical dimensions, and the surface-based radical-generating redox sites. The enhanced radical generation may impair the cellular defense system, resulting in cell injury. Use of scavengers, chelators, and potentiating agents suggests the membrane-based oxidase system as the probable primary source of the radical-generating system. The data presented herein suggest the generation of oxygen free radicals as an important primary event in silica- as well as asbestos-induced cell injury.

Animals↗

Hydroxyl radical generation in the NADH/microsomal reduction of vanadate.

ESR spin trapping measurements demonstrate generation of hydroxyl (.OH) radical from reduction of vanadate by rat liver microsomes/NADH without exogenous H2O2. Catalase decreases the .OH signal while increasing a vanadium (4+) signal. Addition of superoxide dismutase (SOD) or measurements under an argon atmosphere show decreased .OH radical production. The results suggest that during the one-electron vanadate reduction process by microsomes/NADH, molecular oxygen is reduced to H2O2, which then reacts with vanadium (4+) to generate .OH radical via a Fenton-like mechanism.

Animals↗

Comparative laboratory evaluation of three toothbrushes regarding interproximal access efficacy.

A new toothbrush from the Colgate-Palmolive Company, called the Colgate Precision toothbrush, was compared to the Oral-B 40 toothbrush and Reach Full-Head soft toothbrush using a laboratory device designed to simulate clinical toothbrushing motions and pressures. The toothbrushing time was sixty seconds for each vertical or horizontal brushing motion and for each of the three brushing weights tested, 250, 500 or 750 grams. Interproximal access efficacy was determined by measuring the maximum width of the brushing stroke measured on pressure sensitive paper placed around the simulated anterior or posterior teeth. Twenty-four toothbrushes of each design were evaluated for each toothbrushing motion, tooth shape and toothbrushing weight for a total of 864 measurements. In all studies conducted, the Colgate Precision toothbrush had statistically superior total interproximal access efficacy scores compared to the Oral-B and Reach toothbrushes. In several assessments the Reach toothbrush was superior to the Oral-B 40 toothbrush.

Analysis of Variance↗

Thirty-day evaluation of the Stimu-gum gingival stimulator and tooth polisher for clinical safety and efficacy.

Two clinical studies have been performed to assess the intraoral safety and efficacy of a mechanical device containing a rubber cup polisher and interdental stimulator (Stimu-gum). In the first study the potential for producing irritation of the oral mucosal tissues was evaluated in 19 subjects when the Stimu-gum product was used in an exaggerated manner, i.e., five times a day for seven days. No untoward effects attributed to use of the Stimu-gum product were observed or reported at anytime in the study. A thirty-day study on 64 subjects compared the Stimu-gum device with an Oral-B 35 manual toothbrush for safety, plaque removal and gingivitis evaluations, at baseline and after 15 and 30 days of product use. The Stimu-gum product and the Oral-B toothbrush were equally effective in removing overnight plaque. The Stimu-gum device was significantly more effective than the Oral-B toothbrush in reducing gingivitis scores at 30 days and bleeding on probing at 15 days. Bleeding on probing scores continued to be lower in the Stimu-gum group at 30 days; however, differences were not statistically significant compared to the Oral-B mean scores.

Adolescent↗

Aerobic fitness: I. Response of volume regulating hormones to head-down tilt.

We investigated the relationship of aerobic fitness to the response of volume-regulating hormones to acute simulated microgravity. Six untrained (UT) and six endurance-trained (ET) healthy young males were studied in the head-down tilt (HDT) position of -6 degrees for 4 h. Peak oxygen uptake (VO2peak) and plasma volume (PV) were significantly greater in the ET (VO2peak = 61.7 +/- 1.6 ml.min-1.kg-1 and PV = 53.1 +/- 2.8 ml.kg-1) than in the UT (VO2peak = 38.4 +/- 1.7 ml.min-1.kg-1 and PV = 38.8 +/- 1.0 ml.kg-1). Plasma concentrations of atrial natriuretic peptide (ANP), arginine vasopressin (AVP), norepinephrine (NE), renin activity (PRA), and aldosterone (PA) were measured prior to HDT and at minutes 2, 5, 15, 30, 60, 120, 180, and 240 during HDT. PRA and PA significantly decreased during the time of HDT in both groups. The changes in ANP and NE concentrations were not significantly different between the groups nor across time. However, in the ET subjects, the changes in PRA and NE were significantly correlated with the changes in ANP (r = 0.49, P less than 0.01; and r = 0.86, P less than 0.001, respectively); in the UT subjects, the changes in AVP, PRA, and PA were significantly associated with changes in NE (r = 0.34, P less than 0.03; and r = 0.59; and r = 0.53, P less than 0.01, respectively). PV significantly decreased during HDT, and was primarily related to the decrease in PA in both groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Aerobic fitness: II. Orthostasis and VO2peak following head-down tilt.

To determine whether endurance exercise trained (ET) subjects would experience greater reductions in peak oxygen delivery and orthostatic tolerance (OT) than untrained (UT) subjects, both peak oxygen uptake (VO2peak) during upright bicycle ergometry and tolerance time during 70 degrees head-up tilt (HUT) were compared within and between groups before and after 4 h of -6 degrees head-down tilt (HDT). Eight ET subjects with a mean VO2peak of 61.7 +/- 1.6 ml.kg-1.min-1 were matched for age, height, and weight with eight UT subjects (VO2peak = 38.4 +/- 1.7 ml.kg-1.min-1). Following HDT, decreases in plasma volume (PV) were larger for ET subjects (-3.7 +/- 0.5 ml.kg-1) than for UT subjects (-2.3 +/- 0.3 ml.kg-1), P less than 0.03. Reductions in VO2peak for ET subjects (-5.4 +/- 1.1 ml.kg-1.min-1) were also greater than for UT subjects (-2.4 +/- 0.8 ml.kg-1.min-1), P less than 0.05. The ET (N = 6) subjects also had a significant decrease in OT time (-13.0 +/- 4.2 min) during post-HDT HUT, which was not observed for the UT group (N = 6). A significant inverse correlation was found pre-HDT VO2peak and the change in OT time, r = -0.74, P less than 0.01. The decrease in OT was also significantly correlated to the PV decrease, r = 0.59, P less than 0.04. The UT subjects had significantly augmented pressor responses to HUT manifested by the increases in both HR and MAP following HDT.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Reduction in LBNP tolerance following prolonged endurance exercise training.

Eight young men underwent an 8-month endurance exercise training program. Prior to and following the training program, the subjects' maximal oxygen uptake (VO2max), total blood volume (TBV) and plasma volume (PV), tolerance to lower body negative pressure (LBNP) assessed by the cumulative stress index (CSI) to presyncope, and their hemodynamic responses to 0 to -45 torr LBNP was determined. Hemodynamic measures included rebreathe carbon dioxide cardiac output (Qc), heart rate (HR), directly measured arterial blood pressures (ABP), and strain gauge determination of forearm blood flow (FBF) and leg volume changes (delta LgV). Calculated values of stroke volume (SV), forearm, vascular resistance (FVR), and peripheral vascular resistance (PVR) were made. Following training, each subject had an increased VO2max (mean = +27.4%, P < 0.001), TBV (mean = +15.8%, P < 0.02), and PV (mean = +16.5%, P < 0.02) and each subject had a decreased tolerance to LBNP (mean CSI = -24%, P < 0.001). Stepwise linear regression identified that the major factors to significantly predict the decreased CSI pre- to post-training were a reduced response of PVR to LBNP from -15 to -45 torr (Model R2 = 0.853), the delta TBV (model R2 = 0.981), and the greater post-training reduction in SBP to LBNP of 0 to -45 torr (model R2 = 1.0). These data suggest that physiologic adaptations associated with the increased VO2max and TBV resulting from a prolonged endurance exercise training program can alter the reflex control of vasomotion and cardiac output during LBNP and reduce the LBNP tolerance.

Adult↗