Are there vascular density gradients along myocardial laser channels?

BACKGROUND: Clinical studies suggest that transmyocardial laser revascularization may improve regional blood flow of the subendocardial layer. The vascular growth pattern of laser channels was analyzed. METHODS: Twenty pigs were randomized to undergo ligation of left marginal arteries (n = 5), to undergo transmyocardial laser revascularization of the left lateral wall (n = 5), to undergo both procedures (n = 5) or to a control group (n = 5). All the animals were sacrificed after 1 month. Computed morphometric analysis of vascular density of the involved area was expressed as number of vascular structures per square millimeter (+/-1 standard deviation). RESULTS: The vascular density of the scar tissue of the laser channel was significantly increased in comparison with myocardial infarction alone: 49.6+/-12.8/mm2 versus 25.5+/-8.6/mm2 (p < 0.0001). The vascular densities of subendocardial and subepicardial channel areas were similar: 52.9+/-16.8/mm2 versus 46.3+/-13.6/mm2 (p = 0.41). The area immediately adjacent to the channels showed a vascular density similar to that of normal tissue: 6.02+/-1.7/mm2 versus 5.2+/-1.9/mm2 (p = 0.08). In the infarction + transmyocardial laser revascularization group, the channels were indistinguishable from infarction scar. CONCLUSIONS: Scars of transmyocardial laser revascularization channels exhibit an increased vascular density in comparison with scar tissue of myocardial infarction, which does not extend into their immediate vicinity. There was no vascular density gradient along the longitudinal axis of the channels.

Animals↗

Multivalvular surgery for infective endocarditis.

The short and the long-term results of our experience with 25 consecutive patients who underwent multivalvular surgery for infective endocarditis are analysed. Preoperatively, 20/25 (80%) patients were in New York Heart Association (NYHA) stage III or IV, and 2/25 (8%) patients were in cardiogenic shock. All the diseased valves were replaced with mechanical bileaflet prosthesis except seven mitral valves and one tricuspid valve, which could be repaired. Major postoperative complications occurred in 3/25 (12%) patients: a fatal cerebral haemorrhage, a reversible cerebellar syndrome and an intractable heart failure, which required transplantation. During a mean follow-up of 4.7 years (range 6 months to 16.8 years), 7/25 (28%) patients suffered from valve-related complications: five bleedings (one died), one embolic event and one prosthetic valve thrombosis. The actuarial freedom of valve-related event at 10 years was 61.8 +/- 12.4%. There was no prosthetic endocarditis. At follow-up, 20/21 (95%) survivors were in NYHA stage I or II. Long-term outcome in our patient population operated on for multivalvular endocarditis, is satisfactory with no recurrent infection and excellent functional results.

Adolescent↗

Augmented venous return for minimally invasive open heart surgery with selective caval cannulation.

OBJECTIVE: Minimally invasive open heart surgery involves limited intrathoracic cannulation sites necessitating cardiopulmonary bypass to be initiated via peripheral access using percutaneous cannulae with the tip placed into the right atrial cavity. However, surgery involving the opening of the right heart obliges the surgeon to maintain the end of the cannulae into the vena cavae. The impeded venous return due to the smaller diameter may be alleviated by inserting a centrifugal pump in the venous line. METHODS: Right anterior mini-thoracotomy and exposure of the femoral site were performed before the patient was heparinized. Cannulation of the femoral artery, the inferior vena cava via the femoral vein and the superior vena cava through the mini-thoracotomy was performed and cardiopulmonary bypass was initiated. Venous drainage was augmented with the centrifugal pump. Cardiac arrest was provoked and both vena cavae were snared before performing the intracardiac procedure. RESULTS: Twenty consecutive patients were operated on using this technique (15 males/five females; age: 44.8 +/- 14.3 years; bodyweight: 73.5 +/- 15.1 kg; body surface area: 1.8 +/- 0.2 m2; theoretical blood flow rate: 4.4 +/- 0.5 l/min). The cannula sizes were 21.9 +/- 2.2 Fr for the femoral artery, 26.5 +/- 1.7 Fr for the inferior vena cava and 23.8 +/- 2.5 Fr for the superior vena cava. Venous drainage through the single inferior vena cava cannula was 2.1 +/- 0.6 l/min (48.8 +/- 13.3% of the theoretical flow). Adding the superior vena cava cannula increased the venous flow to 3.1 +/- 0.4 l/min (70.7 +/- 9.6% of the theoretical value, P < 0.005). The use of the centrifugal pump increased the flow to 4.1 +/- 0.6 l/min (93.4 +/- 8.9% of the theoretical flow, P < 0.001) with a mean inlet negative pressure of -69 +/- 10.2 mmHg. The mean bypass time was 64.0 +/- 24.6 min for a mean operative time of 226.3 +/- 61.0 min. Minimum venous saturation was 69.4 +/- 8.5%. CONCLUSIONS: Despite the smaller diameter of the vena cavae compared to the right atrium, and a smaller internal diameter of percutaneous cardiopulmonary bypass cannulae compared to classic ones; the centrifugal pump improves the venous drainage significantly so that minimally invasive open heart procedures can be performed under optimal and safe perfusion conditions.

Adult↗

Extramediastinal surgical problems in heart transplant recipients.

BACKGROUND: As heart transplantation has gained wide acceptance, a growing number of recipients are at risk of experiencing extramediastinal surgical problems. STUDY DESIGN: We retrospectively reviewed our experience in the diagnosis and management of surgical problems occurring in 94 consecutive patients having heart transplantation. During the period of the study, we progressively adopted a policy of low-level immunosuppression, aiming toward monotherapy with cyclosporine. RESULTS: Seventy-four extramediastinal surgical problems developed in 44 of 94 patients (47%). The type of problems were gastrointestinal in 17 of 74 (23%), vascular in 13 of 74 (17.5%), urogenital in 8 of 74 (11%), and neurologic in 4 of 74 (5.5%). There were also 9 of 74 cases of trauma (12%), 9 of 74 skin tumors (12%), and 14 of 74 miscellaneous diseases (19%). Sixty-two surgical diseases occurring in 40 patients required 75 surgical interventions, 11 of them (15%) on an emergency basis. Operations were performed for 12 of 74 neoplasms (16%) and 12 of 74 infectious or potentially infectious diseases (16%). Surgical diseases occurred most commonly within the first 6 months after transplantation (20 of 74; 27%). Complications occurred in 8 of 75 surgical interventions (9%). A high proportion of surgical disease was potentially related to immunosuppressive therapy (37 of 74; 50%) or to transplantation itself (7 of 74; 9%). CONCLUSIONS: Extramediastinal diseases after heart transplantation involve most surgical specialties. Most of them are potentially linked with either the immunosuppressive therapy or the transplantation procedure, supporting our low-level immunosuppression policy. Expectant management is not justified in this population, who withstands operations well both early and late after transplantation.

Adolescent↗

[Prevention of pericardial adhesions with a bioresorbable membrane].

A bioresorbable membrane made of sodium hyaluronate and carboxymethycellulose, has been reported to prevent peritoneal adhesion. This study was designed to test its efficiency in the prevention of pericardial adhesions. Two groups of six pigs (mean weight 72 +/- 8 kg) were chosen for the experiment. The heart was exposed through a left thoracotomy and a wide patch of pericardium was excised. In the test group (n = 6), the left ventricular area without pericardium was divided into two areas: area A where six stitches of Prolene were performed, and area B which was left intact. The membrane was applied on the both areas as well as on the adjacent area covered with pericardium (area C). In the control group (n = 6), the same protocol was performed except for the membrane application. The animals were sacrificed one month later. The adhesion status as well as the visibility of the coronary anatomy was assessed according to severity scores ranging from 0 to 3 for the adhesions and from 0 to 2 for the visibility. The difference between groups was considered significant when p < 0.05. The adhesion score of the area A was 1.7 +/- 0.5 in the test group versus 2.5 +/- 0.5 in the control group (p = 0.02) and the visibility score was 1.3 +/- 0.8 and 2 +/- 0 respectively (p = 0.07). In the area B, the adhesion score was 1 +/- 0 in the test group versus 2 +/- 0.6 in the control group (p = 0.03) and the visibility score was 0.7 +/- 0.5 and 2 +/- 0 respectively (p = 0.001). Lastly, in the area C, the adhesion score was 1 +/- 0 in both groups (n.s.) and the visibility score was 0.7 +/- 0.4 in the test group versus 0.5 +/- 0.5 in the control group (n.s.). In this animal model, the role of the bioresorbable membrane in the prevention of pericardial adhesions is limited to the areas without pericardial cover and without foreign material. The presence of foreign material neutralizes its effect.

Animals↗

Thrombogenicity of deflated intraaortic balloon: impact of heparin coating.

In a calf model, 3 standard and 3 heparin coated intraaortic balloons (IAB) were inserted and left deflated in the descending aorta during 20 min to simulate balloon rupture. At the end of the experiment, the IAB were examined, and 3 samples of each were collected for scanning electron microscopy (SEM) analysis. None of the heparin coated IAB showed any sign of clot or deposit whereas all 3 standard IAB exhibited clots. SEM revealed no deposit on the heparin coated samples while 8 of the 9 standard samples disclosed deposits (p < 0.001). Morphometrically, 16.1+/-21.4% of the surfaces of the standard samples were covered with deposits whereas all the heparin coated samples were free (p = 0.004). The presence of clots on every standard IAB supports the hypothesis that other than local factors of the insertion site can play a role in the vascular complications of IAB. The absence of clots and deposits on the heparin coated IAB suggests a promising role of such devices in circumventing the tendency of clot formation on deflated balloons while avoiding the drawback of systemic anticoagulation.

Animals↗

Ex vivo testing of the Quart arterial line filter.

Arterial line filters are now routinely used in cardiac surgery in order to decrease the microemboli load to the patient. The Quart filter (Jostra, Hirrlingen, Germany) with a new planar construction design, an easy de-airing system and an integrated bypass, was tested for air filtration capacity and resistance to blood path in a standardized setting with surviving animals. Three calves (mean body weight: 71+/-3.4 kg) were connected to a standard cardiopulmonary bypass (CPB) circuit by jugular venous and carotid arterial cannulation with a mean flow rate of 3.5 l/min. The arterial line filter was challenged with upstream injections of boluses of air of 5, 10 and 15 ml, respectively. A Doppler ultrasound was positioned downstream on the arterial line to measure bubble count and size. The pressure drop through the filter was monitored at flow rates of between 1 and 6 l/min. At the end of the procedure the animals were weaned from the CPB and, thereafter, from the ventilator. After 7 days, the animals were sacrificed electively. This study shows that important quantities of air can be injected into the arterial line upstream of the filter with small volumes of small sized bubbles recorded downstream. With the 5 ml air bolus injection, mean values of 0.3+/-0.6 bubbles of 30 and 40 microm were detected, whereas with the 20 ml bolus, 32.6+/-8.7 bubbles of 10 microm, 3.7+/-1.1 bubbles of 30 microm, 3.3+/-0.6 bubbles of 40 microm and 0.7+/-1.1 bubbles of 50 microm were recorded. The blood path resistance at different blood flow rates was well within the acceptable range with a pressure drop of 20+/-0 and 26.6+/-5.7 mmHg at flow rates of 4 and 5 l/min, respectively. With its planar concept, the Quart filter offers good air filtering capacity both in terms of bubble count and size after injection of large boluses of air, without any increase of resistance to the blood path. Moreover, it offers a venting function and an integrated bypass system.

Air↗

Intra-aortic balloon: evaluation of heparin-coating under various experimental conditions.

In a calf model, heparin coated intra-aortic balloon (IAB) was compared with standard balloon. In group 1, 9 of each IAB type were set to the automatic mode for 15 min, 45 min and 6 hours respectively, while in group 2, 3 of each IAB type were left deflated during 20 minutes to simulate balloon dysfunction. At the end of the procedures, 3 samples of each IAB were analyzed with scanning electron microscopy (SEM) for surface deposits. Macroscopically, the 12/12 heparin coated IAB of both groups and the 9/9 standard IAB of group 1 were free of deposits, whereas the 3/3 standard IAB of group 2 exhibited clot deposits. SEM revealed deposit-free surfaces in the 36/36 heparin coated samples of both groups, while 14/27 standard samples of group 1 (p<0.01 when compared with heparin coated samples) and 8/9 standard samples of group 2 (p = 0.02, same comparison) disclosed blood cells and fibrin deposits. Morphometrically, the proportion of standard sample surfaces covered with deposits, estimated according to a score system (0% = 0; 0.1-25% = 1; 25.1-50% = 2; 50.1-75% = 3; 75. 1-100% = 4), was 0.69+/-0.82 in group 1 (p<0.01 when compared with heparin coated samples) and 1.22+/-0.83 in group 2 (p<0.01, same comparison). Thus heparin coated IAB presents no deposits either after 6 hours of intravascular ballooning or after 20 minutes of stagnation. It seems to be a promising strategy for patients with absolute or relative contraindications to systemic heparinization.

Animals↗

Trillium coating of cardiopulmonary bypass circuits improves biocompatibility.

Coating of cardiopulmonary bypass circuits may be a solution to prevent adverse effects induced by contact of blood elements with foreign surfaces. Using an animal model, we investigated the Trillium TM coating of cardiopulmonary bypass circuits (a new process involving polyethylene oxide, sulphonate groups and heparin) at low systemic heparinization, focusing on haemolysis and clot formation. Cardiopulmonary bypass was initiated through jugulo-carotid access with ACT maintained around 180 sec. Treated circuits (Trillium group) were evaluated in 3 calves (mean weight of 66.0+/-8.7 kg), vs. untreated circuits in 3 control calves (mean weight of 60.7+/-7.5 kg). Blood samples were drawn at regular intervals for biochemical, hematological and blood gas analyses. After 6 consecutive hours, the animals were weaned from CPB and were awakened. The circuits were analyzed for clot deposits. After 7 days the animals were sacrificed and an autopsy was carried out. Red cell and white cell counts did not change over the 6 hours. Platelet counts dropped to 75.9+/-7.3% of the baseline value in the Trillium group after 6 hours whereas counts dropped to 57.2+/-26.0 in the control group (p<0.05). Plasma free Hb remained constant in the Trillium group but increased significantly to 280+/-65% of baseline value in the control group (p<0.05). The amount of clots were significantly higher in the control group, in the connectors, the reservoir, the heat exchanger, and the oxygenator. No renal emboli were seen in the Trillium group whereas the mean number of emboli was 3.0+/-2.4 in the control group. We conclude that Trillium coating significantly improves the biocompatibility of artificial surfaces exposed to blood.

Animals↗

Optimization of the pump driven venous return for minimally invasive open heart surgery.

Blood return into the cardiotomy reservoir is usually reduced when a cardiopulmonary bypass (CPB) is initiated through a peripheral access, even if the tip of the venous cannula is pushed into the right atrium. A centrifugal pump can be placed on the venous line to increase the negative pressure. Surgery involving the right atrium requires selective cannulation of both vena cavae. Because of the small diameter of the vena cava as compared to the right atrium, the benefit of the centrifugal pump may have limitations. We analyze the factors influencing the active venous return when the cannula is maintained into the vena cava. In 4 calves (83.0+/-14.9 Kg) a CPB was initiated through carotid and jugular access, with the tip of the venous cannula placed into the superior vena cava, before ventricular fibrillation was provoked. Venous drainage was progressively increased thanks to the centrifugal pump. Considering the negative pressure induced on the venous line, we analyzed the performance expressed in l/min of blood drained, of four one stage cannulae ("lighthouse" tip 24F, 28F or 32F, and percutaneous 28F). The performance of all cannulae were highly dependent on the central venous pressure (CVP) with better drainage for higher CVP. The size and type of cannula also significantly affected blood drainage. Active drainage was best with the percutaneous 28F cannula. This cannula was specially attractive at low CVP conditions.

Animals↗

[Minimally invasive surgery for coronary disease: a new alternative].

To avoid the inflammatory syndrome generated by cardiopulmonary bypass, a new surgical technique, minimal invasive direct coronary artery bypass (MIDCAB), has been developed. An anastomosis is performed between the left internal mammary artery (LIMA) and the left anterior descending artery (LAD) on a beating heart, through a limited anterior thoracotomy. We describe our experience with this technique. Ten consecutive patients underwent a MIDCAB procedure. (9 males, age 65.9 +/- 9 years). There were 8 bypasses of the LIMA on the LAD, one bilateral mammary bypass on the LAD and the right coronary artery, and one conversion to a standard sternotomy with CPB for a saphenous vein bypass on the LAD because of injury to the LIMA (2nd case). There was one redo for haemostasis of the mammary artery bed (3rd case). The first 3 patients required postoperative blood transfusion. From the 4th operation onwards, with the introduction of new instrumentation which was better adapted to the narrowness of the surgical field, there were no further surgical complications. During the follow-up (mean 5 months; range 2-9), no patient suffered anginal recurrence. With the improvement of instrumentation, the MIDCAB technique offers satisfactory short- and mid-term results, while avoiding CPB with its adverse effects. Lastly, the cosmetic result is far better than with the conventional procedure.

Aged↗

Long-term results of mitral-aortic valve operations.

OBJECTIVE: We analyzed the long-term morbidity and mortality of our experience with combined mitral-aortic surgery, as well as their determinants. METHODS: Among 2109 consecutive patients undergoing valve operations, 200 had mitral-aortic valve procedures with at least implantation of a mechanical prosthesis: 163 of 200 (81.5%) patients had double valve replacement and 37 of 200 (18.5%) had mitral valve repair and aortic valve replacement. All mechanical valves were bileaflet prostheses. Preoperatively, 171 of 200 (85.5%) patients were in New York Heart Association class III-IV. Event-free survivals were determined by means of the Kaplan-Meier method and determinants of survivals with the Cox proportional hazards model (p < 0.05) entering 39 preoperative and perioperative factors. Follow-up was complete for 96% of the patients (192/200). RESULTS: Overall survivals at 5, 10, and 15 years were 88.5% +/- 0.55%, 73.5% +/- 4%, and 53.3% +/- 8.9%, and rates of freedom from valve-related mortality were 92.9% +/- 1.5%, 85.8% +/- 3.5%, and 85.8% +/- 3.5%. The rates of freedom from permanent valve-related impairment were 91.5% +/- 1.7%, 85.4% +/- 3.5%, and 79.3% +/- 6.7%, and those from all valve-related mortality and morbidity were 74.1% +/- 2.3%, 53.8% +/- 5%, and 49% +/- 5.6%. At last follow-up, 90% (139/154) of the survivors were in New York Heart Association class I-II. Left ventricular ejection fraction less than 50%, age older than 70 years, and preoperative ventricular arrhythmias were independent risk factors for valve-related late deaths. Diabetes, ejection fraction less than 50%, and coronary artery disease were independent determinants of all valve-related events. CONCLUSIONS: Functional results of survivors of combined mitral-aortic surgery are excellent. However long-term valve-related morbidity and mortality are substantial. In the patient population studied, the predictors are determined by patient-related factors, mainly myocardial factors, but not by valve-related factors.

Adolescent↗

Transmyocardial laser revascularisation in acutely ischaemic myocardium.

OBJECTIVE: Although recent experience suggests that transmyocardial laser revascularisation (TMLR) relieves angina, its mechanism of action remains undefined. We examined its functional effects and analysed its morphological features in an animal model of acute ischaemia. METHODS: A total of 15 pigs were randomised to ligation of left marginal arteries (infarction group, n = 5), to TMLR of the left lateral wall using a holmium:yttrium-aluminium garnet (Ho:YAG) laser (laser group, n = 5), and to both (laser-infarction group, n = 5). All the animals were sacrificed 1 month after the procedure. Haemodynamics and echocardiography with segmental wall motion score were carried out at both time intervals (scale 0-3: 0, normal; 1, hypokinesia; 2, akinesia; 3, dyskinesia). Histology of the involved area was analysed. RESULTS: Laser group showed no change of the segmental wall motion score of the involved area 30 min after the laser channels were made (score: 0 +/- 0). Infarction and laser infarction groups both showed a persistent and definitive increase of the segmental wall motion score (at 30 min: 1.6 +/- 0.3 and 2 +/- 0, respectively; at 1 month: 1.8 +/- 0.2 and 1.8 +/- 0.4, respectively). These increases were all statistically significant in comparison with baseline values (P < 0.5), however comparison between infarction and laser-infarction groups showed no significant difference. On macroscopic examination of the endocardial surface, no channel was opened. On histology, there were signs of neovascularisation around the channels in the laser group, whereas in the laser-infarction group the channels were embedded in the infarction scar. CONCLUSIONS: In this acute pig model, TMLR did not provide improvement of contractility of the ischaemic myocardium. To the degree that the present study pertains to the clinical setting, the results suggest that mechanisms other than blood flow through the channels should be considered, such as a laser-induced triggering of neovascularisation or neural destruction.

Animals↗

Acute effects of transmyocardial laser revascularization on left-ventricular function: an haemodynamic and echocardiographic study.

While the lesions produced by transmyocardial laser revascularisation (TMLR) induce scar formation, it is important to determine whether this procedure can be deleterious for the left-ventricular function, which is already impaired by the underlying ischaemic process in some patients. Ten channels were drilled in the left lateral wall of the hearts of ten pigs (mean weight, 61 +/- 8.2kg) with a Holmium:YAG laser. Haemodynamic measurements and echocardiographic assessment of left-ventricular function were performed before the TMLR procedure, 5 and 30 min after, and lastly after 5 min of pacing at a rate increased by 30% of the baseline value. Echocardiographic assessment was in the short axis at the level of the laser channels, and included left-ventricular ejection fraction and segmental wall motility of the lasered area (scale 0-3:0 = normal 1 = hypokinesia, 2 = akinesia, 3 = dyskinesia). Values at 5 and 30 min were compared with baseline values; the difference was considered significant if p < 0.05. Haemodynamical values were stable throughout all the procedures. The ejection fraction showed a slight but significant decrease 5 min after the creation of the channels (60.4 +/- 6.8% vs 54 +/- 7.6%, p=0.02) and recovered at 30min. The segmental motility score of the involved areas increased to 1 after 5 min in five animals, and came back to 0 at 30 min except in one animal. Even with pacing no segmental dysfunction occurred. The reversibility of the segmental hypokinesia induced by TMLR, as well as the absence of pace-induced dysfunction 30 min after the procedure strongly suggest the inocuity of TMLR in this experimental set-up.

Animals↗

Heparin removal after cardiopulmonary bypass in a patient with adverse reaction to protamine.

A 74-year-old man underwent elective coronary surgery under cardiopulmonary bypass. A few minutes after the protamine administration was started, he suddenly developed a severe hypotension necessitating cardiac massage and recannulation for pump assistance. A further test dose of protamine provoked an identical reaction. We installed a Heparin Removal Device, which allows for ex-vivo deheparinization. In 35 minutes ACT decreased from 480 sec to 180 sec and clots appeared in the operating field. This system provides an excellent alternative to protamine in patients with an adverse reaction to protamine.

Aged↗

Air trapping ability of the Spiral Gold membrane oxygenator: an ex vivo study.

Despite an overall improvement in cardiopulmonary bypass (CPB) technology and materials, air emboli still occur. The latest generation membrane oxygenator from Bentley Laboratories, the SpiralGold, was tested ex vivo for its air handling ability. The study was conducted on four calves. Bolus amounts of air of 10, 15 and 20 cm3 were each injected three times, upstream of the oxygenator and a bubble detector located directly downstream. The amount of bubbles was measured semiquantitatively on a 10 unit scale (U one semiquantitative unit). The animals were killed 10 days after the CPB. When 10 cm3 of air was injected, no bubbles were detected. With 15 and 20 cm3, respectively, 1 +/- 1.5 and 5 +/- 3.3 U of bubbles were detected. Despite a total of 135 cm3 of air injected as large bolus amounts, all the animals survived without any obvious neurological deficit secondary to air bubble manipulation. In conclusion, the SpiralGold oxygenator per se can reliably trap an air bolus of up to 10 cm3. This feature should be taken into account when choosing an oxygenator, as it offers an additional barrier to air bubbles in the CPB circuit.

Animals↗

Experimental evaluation of the Dideco D903 Avant 1.7 hollow-fibre membrane oxygenator.

Membrane oxygenators have now gained wide acceptance. A new hollow-fibre membrane oxygenator, the Dideco D903 Avant 1.7, with an optimized membrane surface (1.7 m2) and a wavy blood flow pattern, was tested for gas transfer and blood path resistance in a standardized setting with surviving animals. Three calves (mean body weight 63.29 +/- 2.9 kg) were connected to cardiopulmonary bypass by jugular venous and carotid arterial cannulation, classic roller pump and the Dideco D903 oxygenator with a mean flow rate of 53 +/- 0.1 ml/kg/min for 6 h. After this time, the animals were weaned from the CPB and thereafter from the ventilator. After 7 days, the animals were killed electively. Blood gas analysis was performed before bypass, after mixing (10 min) and then hourly for the 6 h of perfusion. Further samples were taken 30 min (spontaneous breathing) and 60 min after bypass (extubated). Physiological blood gas values could be maintained throughout perfusion in all animals. Mean arterial oxygen saturation varied between 99.3% and 99.7% for the arterial side of the oxygenator compared to 64.6% and 71% for the venous side. The highest mean pressure drop through the oxygenator was 54 mmHg. Postbypass blood gas analysis showed physiological values and no evidence of major lung trauma or pulmonary oedema in relation to the 6 h perfusion. The hollow-fibre membrane oxygenator, Dideco D903, offers excellent gas exchange capabilities and a low pressure drop under experimental conditions, despite reduced membrane surface area. The post mortem examination did not show any deleterious lesion.

Animals↗