Images in cardiovascular medicine. Non-life-threatening leaflet escape.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to William Wijns.
Explore the source record for details and available documents.
The Plasma level of angiotensin-converting enzyme (ACE) has been identified as a major risk factor for restenosis after coronary stent implantation in selected patients; ACE inhibition may therefore contribute to prevent its occurrence. The effect of oral ACE inhibition at conventional doses was analyzed retrospectively in a series of 897 patients with ischemia who received >or=1 coronary stent on 998 lesions and underwent angiographic follow-up; no exclusion criteria were introduced in this analysis. The restenosis rate in 282 patients (31.4%) taking ACE inhibitors was 36.6% compared with 22.9% in 615 non-ACE-inhibited patients (p = 0.00001, odds ratio [OR] 1.94, 95% confidence interval [CI] 1.45 to 2.59), and the late loss in minimum lumen diameter was 1.25 +/- 0.8 versus 0.96 +/- 0.8 mm, respectively (p = 0.0001). During univariate analysis, a negative effect of the drug on restenosis was observed in all subgroups of patients (i.e., hypertensives, diabetics, women, and patients with previous myocardial infarction). Similar effects were observed independently of the ACE gene insertion/deletion polymorphism. During multivariate analysis, ACE inhibition was confirmed as an independent risk factor for restenosis (OR 1.84, 95% CI 1.35 to 2.51, p = 0.0001). Other predictors were the implantation of multiple stents (OR 2.41, 95% CI 1.60 to 3.64, p <0.0001), diabetes (OR 2.34, 95% CI 1.61 to 3.41, p <0.0001), and vessel reference diameter before angioplasty (OR 0.51, 95% CI 0.38 to 0.69, p <0.0001). Although unexplained and apparently contradictory, our data suggest that the use of conventional oral doses of ACE inhibitors in a "real-world" population who underwent coronary stent implantation increases the incidence of in-stent restenosis. Such a finding does not negate the known clinical benefits of ACE inhibitors, but it may deserve attention when a patient treated with ACE inhibitors becomes a candidate for stent implantation.
Explore the source record for details and available documents.
Stents have ameliorated the outcome of percutaneous coronary interventions. Improved design, profile and flexibility of the currently available stents now permit to deliver the stent without pre-dilatation. In western European countries, stent implantation now occurs in up to 80% of all percutaneous revascularization procedures. In selected cases the safety and feasibility of direct stenting over conventional balloon-predilatation stenting has been demonstrated, in association with slightly superior outcome. This likely results from reduced vessel wall damage-dissections are sealed at the moment they are created-and distal embolization is reduced. In addition, a significant reduction in terms of costs and duration of procedures was demonstrated, while restenosis rate is not reduced with direct stenting.
The aim of this prospective, multicenter, single arm study was to assess the safety and feasibility of EXPRESS Coronary Stent implantation in native coronary arteries without balloon predilatation. Forty-two patients with de novo or restenotic lesions were enrolled, of which 38 were eligible for analysis. The coronary lesions were predominantly complex, occurring in arteries with a mean reference diameter of 2.80 +/- 0.49 mm. Technical and procedural success were achieved in 89.5% and 84% of the cases respectively. The mean minimal lumen diameter increased from 1.08 +/- 0.26 mm to 2.55 +/- 0.44 mm and diameter stenosis decreased from 61 +/- 7% to 13 +/- 8%. The primary endpoint of major adverse cardiac events at 30 days was 2.6% and was limited to only one event (target vessel revascularization, nontarget lesion). No other MACE were observed during the three-month follow-up period. Based on the findings of this study, direct stenting with the EXPRESS Stent appears feasible and is well tolerated.
OBJECTIVES: The authors sought to determine the incidence and causes of geographical miss (GM) and evaluate its impact on edge restenosis after 'primary', centered, intracoronary beta-radiation therapy. BACKGROUND: Edge restenosis is a limitation of intracoronary beta-radiation therapy. GM occurs when the radiation source does not fully cover the injured segment and may account for this phenomenon. METHODS: One hundred and eighty-one patients enrolled in the Dose-Finding study were retrospectively analyzed. The patients were randomized to receive 9, 12, 15 or 18 Gy at 1 mm tissue depth. Using quantitative coronary angiography the effective irradiated segment (EIRS) and both edges were studied prior to and after intervention, and at six-month follow-up. GM was defined as a situation where the effective radiation source length (24 mm) did not fully cover the injured segment. The edges of the EIRS that were injured during the procedure constituted the GM edges. A greater than 50% diameter stenosis at follow-up was considered significant. GM was determined by the simultaneous, electrocardiographically matched, side-by-side projection of the source and balloons in place, in identical projections surrounded by contrast. RESULTS: In 16% of patients GM was noninterpretable owing to inadequate filming. GM constituted 21.1% of the interpretable edges and 40.1% of the interpretable vessels analyzed. The occurrence of restenosis in the EIRS and the analyzed vessel segment (VS) was similar between procedures with and without GM. In vessels with GM, restenosis was significantly increased from the EIRS to the VS (from 8.77% to 21%, p = 0.05) as opposed to non-GM vessels (from 11.9% to 19%, p = 0.6). GM tended to be associated with a greater incidence of significant stenosis at the edges of the EIRS (8.3% versus 4.0%, p = 0.15) compared with individuals with >50 % stenosis but no GM. This effect was more prominent at the distal edge. The relation of GM and edge restenosis was independent of dosage. CONCLUSIONS: Since GM does not affect the incidence of restenosis in the EIRS, restenosis in this segment should be considered a treatment failure, probably due to inadequate dosage. GM is related to significant increase in restenosis from the EIRS to the VS. GM tends to be associated with restenosis at the edges of the EIRS. This is a local phenomenon, which is independent of dosage and which has a specific pathophysiology (combination of injury and low-dose radiation). If GM can be eliminated, the results of vascular brachytherapy will be improved.
Explore the source record for details and available documents.
Patients with diffuse in-stent restenoses (ISRs) are at high risk for recurrent restenosis after percutaneous transluminal balloon angioplasty (PTCA). Percutaneous transluminal rotational ablation (PTCR) has proved effective in removing neointimal burden in ISRs. This study compares the acute and long-term results of PTCA and PTCR for the treatment of diffuse ISR in a randomized, multicenter investigation. The primary end point was the comparison of the minimum luminal diameter (MLD) between both groups at 6-month follow-up. Patients with symptomatic, diffuse, or high-grade ISRs were included; 146 patients were randomized to PTCA and 152 patients to PTCR. Diameter stenosis was reduced from 80 +/- 12% to 29 +/- 10% and from 80 +/- 11% to 28 +/- 12%, respectively, and MLD increased from 0.55 +/- 0.3 to 1.9 +/- 0.3 mm in the PTCA group and from 0.54 +/- 0.3 mm to 1.9 +/- 0.4 mm in the PTCR group. Spasm in the treated vessel and an intermittent slow flow phenomenon occurred more often after rotational ablation (17.7% vs 8.6%, p = 0.001; 5.3% vs 0%, p = 0.007). Minimum stenosis diameter at 6-month follow-up was smaller in the PTCR group than in the PTCA group (1.0 +/- 0.6 vs 1.2 +/- 0.6 mm, p = 0.008) and the restenosis rate was higher (64.9% vs 51.2%, p = 0.027). Procedural factors did not influence long-term outcome. In the PTCR group, the restenosis rate increased with decreasing vessel size, whereas this was not seen in the PTCA group. The lesion length and the baseline diameter stenosis were found to be predictive of restenosis with both treatment strategies; however, a residual diameter stenosis of <30% predicted absence of a restenosis only in the PTCR group. Thus, PTCA and PTCR of diffuse ISRs yield comparable acute angiographic results. The recurrence of a restenosis is higher after PTCR than after PTCA.
BACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2+/-5 versus 37+/-28 mm3) and percent of volume obstruction (1+/-3% versus 29+/-20%) at 6 months between the 2 groups was highly significant (P<0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition in the sirolimus group compared with the uncoated stent group (P<0.05), it was not associated with any adverse clinical events at 1 year. CONCLUSIONS: Sirolimus-eluting stents are effective in preventing neointimal hyperplasia without creating edge effect and without affecting the plaque burden behind the struts.
Accurate prediction of improvement in left ventricular ejection fraction (LVEF) after revascularisation is critical in the therapeutic decision-making process in patients with chronic ischaemic dysfunction. Positron emission tomography (PET) allows non-invasive evaluation of myocardial blood flow (MBF), metabolic rate of glucose (MRG, absolute and relative) and the water-perfusable tissue fraction (PTF). Each of these indices has been proposed for the prediction of functional recovery. Their relative merits, however, are unknown, because a direct head-to-head comparison of their predictive accuracy in the same patients has not been performed. In this study, MBF, MRG (absolute and relative) and PTF were evaluated in 34 patients with severe ischaemic LV dysfunction (LVEF 32%+/-9%). MBF and PTF were determined by oxygen-15 labelled water PET, and MRG (absolute and relative) was determined by fluorine-18 fluorodeoxyglucose (FDG) PET during hyperinsulinaemic euglycaemic clamp. LVEF was measured by radionuclide ventriculography before and 4-6 months after surgery. Sensitivities of MBF, PTF, absolute MRG and relative MRG in predicting improvement in LVEF were 80%, 80%, 90% and 100%, respectively. Their specificities were 54%, 67%, 71% and 71%, respectively. The lowest specificity was obtained for MBF, an intermediate specificity was obtained for PTF and the highest specificities were obtained with FDG PET using absolute and relative MRG. It is concluded that metabolic imaging is superior to perfusion-based indexes for assessment of the potential for functional recovery after revascularisation.
We recently demonstrated that an allelic polymorphism in the haptoglobin gene is a major determinant of susceptibility to a number of vascular disorders. We set out to determine if haptoglobin phenotype was predictive of the development of restenosis in a consecutive series of patients, all of whom underwent stent implantation followed by repeat angiography with quantitative coronary angiography analysis 6 months later. This study included 214 consecutive patients undergoing stent implantation for de novo lesions between 1998 and 1999 in Aalst, Belgium. All underwent follow-up quantitative coronary angiography analysis 6 months after the procedure. The haptoglobin phenotype was determined by electrophoresis. No significant differences were found between patients segregated by phenotype with respect to clinical, procedural, and angiographic factors previously suggested to influence the development of restenosis. None of the diabetic patients homozygous for the haptoglobin 1 allele developed restenosis compared with a >50% restenosis rate for diabetic patients with at least 1 haptoglobin 2 allele (p <0.02). In all patients (diabetic and nondiabetic), we observed a trend toward a lower incidence of restenosis in patients homozygous for the 1 allele (21% vs 33%, p <0.09). Moreover, we found a graded risk relation to the number of haptoglobin 2 alleles. The risk of developing restenosis was greater in subjects with 2 haptoglobin 2 alleles (36%) than in those with 1 haptoglobin 2 allele (31%) or no haptoglobin 2 alleles (21%). Thus, knowledge of the haptoglobin phenotype may be useful in assessing and utilizing new therapies that attempt to reduce restenosis, and may have important implications for the risk stratification algorithm used in managing diabetic patients with coronary artery disease.
OBJECTIVES: We sought to assess the relationship between completeness of revascularization and adverse events at one year in the ARTS (Arterial Revascularization Therapies Study) trial. BACKGROUND: There is uncertainty to what extent degree of completeness of revascularization, using up-to-date techniques, influences medium-term outcome. METHODS: After consensus between surgeon and cardiologist regarding the potential for equivalence in the completeness of revascularization, 1,205 patients with multivessel disease were randomly assigned to either bypass surgery or stent implantation. All baseline and procedural angiograms and surgical case-record forms were centrally assessed for completeness of revascularization. RESULTS: Of 1,205 patients randomized, 1,172 underwent the assigned treatment. Complete data for review were available in 1,143 patients (97.5%). Complete revascularization was achieved in 84.1% of the surgically treated patients and 70.5% of the angioplasty patients (p < 0.001). After one year, the stented angioplasty patients with incomplete revascularization showed a significantly lower event-free survival than stented patients with complete revascularization (i.e., freedom from death, myocardial infarction, cerebrovascular accident and repeat revascularization) (69.4% vs. 76.6%; p < 0.05). This difference was due to a higher incidence of subsequent bypass procedures (10.0% vs. 2.0%; p < 0.05). Conversely, at one year, bypass surgery patients with incomplete revascularization showed only a marginally lower event-free survival rate than those with complete revascularization (87.8% vs. 89.9%). CONCLUSIONS: Complete revascularization was more frequently accomplished by bypass surgery than by stent implantation. One year after bypass, there was no significant difference in event-free survival between surgically treated patients with complete revascularization and those with incomplete revascularization, but patients randomized to stenting with incomplete revascularization had a greater need for subsequent bypass surgery.
OBJECTIVES: We sought to investigate the clinical benefit of additional stent implantation after achieving an optimal result of balloon angioplasty (BA) in long coronary lesions (>20 mm). BACKGROUND: Long coronary lesions are associated with increased early complications and late restenosis after BA. Stenting improves the early outcome, but stent restenosis is also related to both lesion length and stent length. METHODS: A total of 437 patients with a single native lesion 20 to 50 mm in length were included and underwent BA, using long balloons matched to lesion length and vessel diameter (balloon/artery ratio 1.1) to achieve a diameter stenosis (DS) <30% by on-line quantitative coronary angiography (QCA). "Bail-out stenting" was performed for flow-limiting dissections or >50% DS. Patients in whom an optimal BA result was achieved were randomized to additional stenting (using NIR stents) or no stenting. The primary end point was freedom from major adverse cardiac events (MACE) at nine months, and core laboratory QCA was performed on serial angiograms. RESULTS: Bailout stenting was necessary in 149 patients (34%) and was associated with a significantly increased risk of peri-procedural infarction (p < 0.02). Among the 288 randomized patients, the mean lesion length was 27+/-9 mm, and the vessel diameter was 2.78+/-0.52 mm. The procedural success rate was 90% for the 143 patients assigned to BA alone (control group), as compared with 93% in the 145 patients assigned to additional stenting (stent group), which resulted in a superior early minimal lumen diameter (0.54 mm, p < 0.001) and led to reduced angiographic restenosis (27% vs. 42%, p = 0.022). Freedom from MACE at nine months was 77% in both groups. CONCLUSIONS: A strategy of provisional stenting for long coronary lesions led to bailout stenting in one-third of patients, with a threefold increase in peri-procedural infarction. Additional stenting yielded a lower angiographic restenosis rate, but no reduction in MACE at nine months.
The dose distribution around an intravascular brachytherapy 90Y line source with centering balloon catheters was measured with a plastic scintillator, TLD and radiochromic film. The absolute dose rates measured with the three detectors in a solid water phantom at 1, 2 and 3 mm distance from the centering balloon surfaces are in agreement within 3.5%, when the detectors are calibrated with the same 90Sr/90Y source. The dose rates measured with the plastic scintillator in the solid water phantom are in agreement with those directly measured in water. The measured relative dose distributions can be reproduced by Monte Carlo calculations. Also, the influence of the balloon diameter on the dose rate can be reproduced by the calculations. The dose rate calibration routinely performed with the plastic scintillator was checked for fifty-one sources with a well chamber and with another dedicated dose rate checking device. These measurements show that the consistency of the calibration of these sources was better than 10%. In a previous paper absolute dose rates for five other 90Y sources measured with TLD and radiochromic film in a solid water phantom were compared with those obtained with the plastic scintillator in water [Piessens and Reynaert, "Verification of absolute dose rates for intravascular beta sources," Phys. Med. Biol. 45, 2219-2231 (2000)]. Differences of 25 to 41%, depending on the balloon diameter, were reported. In this paper we show the evidence for three main reasons for these previously observed discrepancies: an inconsistency between a detector calibration performed with a 6 MeV electron beam and with a calibrated 90Sr/90Y source from NIST (16%), inaccuracies of the measuring distances in the solid water phantom (maximum 7.5%) and a time instability of the plastic scintillator, probably due to radiation damage (6%).
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: This study evaluated vascular brachytherapy (VBT) as a potent antiproliferative treatment to prevent in-stent restenosis (ISR) after coronary angioplasty of de novo lesions in patients carrying the D allele of the I/D polymorphism of the ACE gene and high ACE plasma levels (>34 U/l). METHODS AND MATERIALS: A prospective randomized trial was designed to detect a 30% improvement in the minimal lumen diameter (MLD) of the stenotic artery, as measured by quantitative coronary analysis (QCA), 6 months following VBT at the time of stented angioplasty. All patients were carriers of the D allele of the ACE gene, with plasma ACE levels >34 U/l. RESULTS: Thirty-one patients (33 stenoses) were allocated to stent implantation (control group) and 30 patients (31 stenoses) to VBT and stented angioplasty. After angioplasty, in-stent MLD was similar in the two groups. At 6 months in the control group, in-stent MLD had decreased to 1.74+/-0.8 versus 2.25+/-1.05 mm in the VBT group (P=.04). The mean in-stent diameter was 2.3+/-0.8 mm in the control group versus 2.9+/-1.05 mm after VBT (P=.02), and the restenosis rate was 37.5% versus 17.9%, respectively (P=.08). At 6 months, a higher need for target vessel revascularization (TVR) was observed in the control group: 35.5% versus 13.3% (P=.04). CONCLUSIONS: This randomized study confirms that patients with high plasma ACE concentrations are exposed to an increased risk for ISR after coronary stenting. The preventive use of VBT in these patients reduced neointimal formation by 65% such that the MLD at follow-up was increased by 29% compared with the control group.
Reperfusion treatment of ST-segment elevation myocardial infarction (STEMI) is one of the medical interventions with the largest potential for saving human lives, independently of age and gender. An attempt to reopen an acutely occluded coronary artery can be done within a wide array of possibilities, from the simple administration of aspirin to the combination of drugs and complex coronary artery interventions. Fibrinolytic drugs and aspirin represent the easiest way to attempt reperfusion and together offer an acceptable compromise between opportunity for treatment and efficacy. Other drugs and the use of invasive revascularization alternatives yield further advantages, and in some high-risk subgroups may be the most rational treatment approach. Beyond investigator's bias and dedication to either form of reperfusion treatment, interventions and/or drugs should be used as needed (and as possible) to increase the overall impact of reperfusion treatment in the community, taking advantage of the best potential of each approach. Most resources have been directed toward the improvement of reperfusion rates with the combination of fibrinolytic and antiplatelet drugs or with angioplasty. These efforts have certainly raised costs, but have not decisively improved clinical outcome nor have they broadened the impact of reperfusion treatment in the community. Indeed, the main shortcoming of reperfusion therapy is that the cohort of untreated patients is still larger than the cohort of treated patients. At a time when mortality of patients with STEMI reaching the hospital and receiving treatment has decreased significantly, the prehospital diagnosis and treatment of STEMI with the objective of enlarging the treated population and shortening the pretreatment delays is likely the best strategy to further reduce mortality. The need for a population approach to treatment of STEMI is even more obvious when considering the expanding patient load that continuously worsens its clinical risk profile, together with the increasing incidence of diabetes, obesity, hypertension, and smoking habits. The target for improving reperfusion treatment of STEMI in the future, and thereby saving more lives, seems now to involve a cultural change and fulfillment of an organizational mission more than an incremental improvement in the current pharmacologic or interventional approach. These epidemiologic and social aspects of contemporary medicine deserve full attention at a time when researchers, clinicians, and health care providers tend to focus primarily on technological advances.