Search PubMed⌕ Search

Biomedical subjects

William R Heineman

Publications and source records attributed to William R Heineman.

At least 19 recordsLinked to original sources

Highly oxidizing excited states of Re and Tc complexes.

Like the Re analogue, the ligand-to-metal charge transfer (LMCT) excited-state of [Tc(dmpe)3]2+ (dmpe is bis-1,2-(dimethylphosphino)ethane) is luminescent in solution at room temperature. Surprisingly, both [M(dmpe)3]2+* species have extremely large excited-state potentials (ESPs) as oxidants-the highest for any simple coordination complex of a transition metal. Furthermore, this potential is available using a photon of visible light (calculated for M = Re(Tc); E1/2* = +2.61(2.52) V versus SCE; lambdamax = 526(585) nm). Using a Rehm-Weller analysis with a series of aromatic hydrocarbons as electron-transfer quenchers, E1/2(Re2+*/Re+) has been determined to be 2.58 V, in good agreement with the calculated value. Both [M(dmpe)3]2+* species are quenched by chloride ion and both can function as excited-state oxidants in water solution.

Organometallic Compounds↗

Unlimited-volume electrokinetic stacking injection in sweeping capillary electrophoresis using a cationic surfactant.

Sweeping is an effective and convenient way for online sample preconcentration in micellar electrokinetic chromatography. The usual procedure includes a hydrodynamic injection step carried out by applying pressure to the sample vial followed by the subsequent sweeping and separation processes. The injected sample volume is limited by the dimensions of the capillary because a part of the capillary has to be left free of sample solution for the subsequent sweeping and separation steps. In addition, when a short capillary, such as 4-10 cm, is used for sweeping, the injected sample volume is small even if the entire capillary is filled with sample solution. To solve this problem, an electrokinetic stacking injection (EKSI) scheme was developed by using a cationic surfactant, dodecyltrimethylammonium bromide, for sweeping in capillary electrophoresis. An experimental model was proposed, and the entire process was theoretically analyzed. According to the theoretical discussion, the optimal conditions for two model analytes, 5-carboxyfluorescein (5-FAM) and sodium fluorescein (FL), were experimentally determined. The injected sample plug lengths for 5-FAM and FL under 20.1 kV for 60 min were experimentally estimated as 836 and 729 cm, corresponding to 28- and 24-fold the effective capillary length, respectively. The EKSI scheme resulted in increased detection factors for 5-FAM and FL of 4.5 x 10(3) and 4.0 x 10(3) using 60-min injection relative to a traditional pressure injection.

Cations↗

On-line sample preconcentration by sweeping with dodecyltrimethylammonium bromide in capillary zone electrophoresis.

On-line sample preconcentration of oligonucleotides with a new sweeping carrier was developed by using dodecyltrimethylammonium bromide (DTAB) below the critical micelle concentration (CMC). The sweeping results with DTAB below and above the CMC were compared. The use of DTAB below the CMC benefits the preconcentration of the oligonucleotides, while the use of DTAB above the CMC is good for hydrophobic small molecules. The factors affecting the sweeping results were optimized and this method was evaluated by constructing calibration curves for thrombin aptamers. The sweeping scheme produced a 112-fold sensitivity enhancement for the oligonucleotides relative to that run in a running buffer without DTAB. The sweeping method developed here can be a good reinforcement of the preconcentration scheme by sweeping when less-hydrophobic analytes or large negatively-charged molecules need to be preconcentrated.

Acetonitriles↗

On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis.

Previous reports describing sample stacking on microchip capillary electrophoresis (microCE) have regarded the microchip channels as a closed system and treated the bulk flow as in traditional capillary electrophoresis. This work demonstrates that the flows arising from the intersection should be investigated as an open system. It is shown that the pressure-driven flows into or from the branch channels due to bulk velocity mismatch in the main channel should not be neglected but can be used for liquid transportation in the channels. On the basis of these concepts, a sample preconcentration scheme was developed in a commercially available single-cross glass chip for microCE. Similar to field-amplified stacking injection in traditional CE, a low conductivity sample buffer plug was introduced into the separation channel immediately before the negatively charged analyte molecules were injected. The detection sensitivity was improved by 94-, 108-, and 160-fold for fluorescein-5-isothiocyanate, fluorescein disodium, and 5-carboxyfluorescein, respectively, relative to a traditional pinched injection. The calibration curves for fluorescein and 5-carboxyfluorescein demonstrated good linearity in the concentration range (1-60 nM) investigated with acceptable reproducibility of migration time and peak height and area ratios (4-5% RSD). This preconcentration scheme will be of particular significance to the practical use of microCE in the emerging miniaturized analytical instrumentation.

Buffers↗

Analytical performance of polymer-based microfluidic devices fabricated by computer numerical controlled machining.

A study comparing the electrophoretic separation performance attainable from microchips molded by masters fabricated using conventional CNC machining techniques with commercial microchips, wire imprinted microchips, and microchips from LIGA molding devices is presented. An electrophoresis-based detection system using fluorescence microscopy was used to determine the analytical utility of these microchips. The separation performance of CNC microchips was comparable to commercially available microchips as well as those fabricated from LIGA masters. The important feature of the CNC machined masters is that they have rapid design-to-device times using routinely available machining tools. This low-cost prototyping approach provides a new entry point for researchers interested in thermoplastic microchips and can accelerate the development of polymer-based lab-on-a-chip devices.

Computer-Aided Design↗

Luminescence from the trans-dioxotechnetium(V) chromophore.

The luminescence of trans-[TcO2(L)4]+ (L = pyridine (py) or picoline (pic)) and trans-[TcO2(CN)4]3- at room and low temperature is described and represents the first example of room temperature excited-state luminescence observed for Tc complexes. At room temperature, the complexes exhibited broad luminescence with emission maxima ranging from 745 to 780 nm. Analogous to the Re complexes (emission at 635-655 nm), the low-temperature emission spectra of microcrystalline samples of [TcO2(py)4]BPh4 and [TcO2(pic)4]BPh4 display the characteristic progressions of the symmetric O=Tc=O and Tc-L stretching modes. DFT/TDDFT calculations were performed on the trans-[MO2(L)4]+ (M = Re, Tc) congeners and predicted the dioxotechnetium emission to be 0.41 eV lower in energy than its Re analogue. Low-temperature lifetimes (8 K) ranging from 15 to 1926 mus for the series of Tc complexes are consistent with the Re analogues.

Journal Article↗

The autofluorescence of plastic materials and chips measured under laser irradiation.

Plastic materials have the potential to substitute for glass substrates used in microfluidic and microTAS systems adding flexibility in materials' choices. Optical quality plastic materials with a low autofluorescence are crucial for optimal detection by fluorescence and laser induced fluorescence techniques. This paper summarizes a series of optical investigations on commercially available plastic chip materials (PMMA, COC, PC, PDMS) and chips made from those materials. Intrinsic optical constants of plastic materials-refractive index for bulk materials-determined by spectroscopic ellipsometry and transmission spectroscopy in the visible range are presented. The laser-induced autofluorescence of materials and chips was assessed at four laser wavelengths, namely, 403, 488, 532 and 633 nm. Considerable bleaching of the autofluorescence was observed under continuous laser illumination. Overall, the longer wavelength laser excitation sources yielded less autofluorescence. PDMS exhibited the least autofluorescence and was comparable to BoroFloat glass. In all cases, chips exhibited slightly higher autofluorescence than the raw plastic materials from which they had been made.

Equipment Failure Analysis↗

Estimation of pK(a) values using microchip capillary electrophoresis and indirect fluorescence detection.

Microchip capillary electrophoresis (CE), coupled with indirect fluorescence detection was investigated for estimating the pK(a) values of non-fluorescent compounds. The CE method is based on the differences in electrophoretic mobility of the analyte as a function of the pH of the running buffer. Nine compounds were tested, including several of pharmaceutical importance, with pK(a) values from 10.3 to 4.6. All buffers contained 5-TAMRA as the fluorescent probe for indirect detection. Calculated pK(a) values agreed well with literature values obtained by traditional methods, differing not more than 0.2 from the literature value. The current work on single lane chips demonstrates the principle of microchip CE with indirect detection as a viable method for estimating pK(a) values. However, increased throughput will be required using a multilane chip to enable the approach to be used practically.

Aniline Compounds↗

Dynamic in situ spectroscopic ellipsometry of the reaction of aqueous iron(II) with 2,2'-bipyridine in a thin Nafion film.

Dynamic in situ spectroscopic ellipsometry studies of the chemical reaction between ferrous ion and 2,2'-bipyridine (bpy) in a thin Nafion film are presented. A simple prototype system composed of a thin Nafion film on a glass substrate was used throughout the work. The reaction was detected by optically monitoring the formation of the strongly absorbing complex ion, Fe(bpy)3(2+) (epsilon 520 = 7.70 x 10(3) M(-1) cm(-1) in 0.1 M NaCl). The changes in film optical constants, n and k, and the thickness upon exposure of it to various solutions were monitored in a flow cell with the film on the backside of the substrate relative to the interrogation by light. A "step-by-step" approach was used to isolate the component parts of the system in which the film was consecutively exposed to solutions in the following order: supporting electrolyte, bpy, and, last, ferrous iron solution. The optical properties of the materials were quantitatively described before and during mass transport within the film by modeling using the appropriate multilayer optical models, i.e., the Cauchy equation for nonabsorbing media and the Urbach and Tauc-Lorentz (oscillator) functions for a film that absorbed. The experiments done allowed study of the diffusion in the film and the chemical reactions that are important in the sensing scheme for ferrous iron. Ligand (bpy) diffusion followed a two-stage diffusion mechanism described by a Berens-Hopfenberg model for incremental sorption (D25 = 7.04 x 10(-13) cm2 s(-1)). The stabilities of the appropriate systems, i.e., Nafion film with bpy, iron, and iron complex, were studied by exposing equilibrated films to circulating supporting electrolyte solutions. The measurements gave important insights into a set of film chemical reactions and, in turn, selective film dynamics. This work exemplifies the usefulness of spectroscopic ellipsometry in monitoring the kinetics of a chemical reaction in situ, as well as the changes in the film physical properties under dynamic conditions.

Journal Article↗

Amperometric determination of live Escherichia coli using antibody-coated paramagnetic beads.

Detecting and enumerating fecal coliforms, especially Escherichia coli, as indicators of fecal contamination, are essential for the quality control of supplied and recreational waters. We have developed a sensitive, inexpensive, and small-volume amperometric detection method for E. coli beta-galactosidase by bead-based immunoassay. The technique uses biotin-labeled capture antibodies (Ab) immobilized on paramagnetic microbeads that have been functionalized with streptavidin (bead-Ab). The bead-Ab conjugate captures E. coli from solution. The captured E. coli is incubated in Luria Bertani (LB) broth medium with the added inducer isopropyl beta-D: -thiogalactopyranoside (IPTG). The induced beta-galactosidase converts p-aminophenyl beta-D: -galactopyranoside (PAPG) into p-aminophenol (PAP), which is measured by amperometry using a gold rotating disc electrode. A good linear correlation (R2 = 0.989) was obtained between log cfu mL(-1) E. coli and the time necessary to product a specific concentration of PAP. Amperometric detection enabled determination of 2x10(6) cfu mL(-1) E. coli within a 30 min incubation period, and the total analysis time was less than 1 h. It was also possible to determine as few as 20 cfu mL(-1) E. coli under optimized conditions within 6-7 h. This process may be easily adapted as an automated portable bioanalytical device for the rapid detection of live E. coli.

Aminophenols↗

Immunoassay for B. globigii spores as a model for detecting B. anthracis spores in finished water.

The 2001 anthrax alarm in the US raised concerns about the Nation's preparedness to the threat of bioterrorism, and the demand for early warning systems that might be used in the case of a biological attack continues to grow. Here we develop an ultra-sensitive rapid detection method for B. globigii(BG) spores, the simulant of B. anthracis(BA) spores. BG spores were detected by a bead-based sandwich immunoassay with fluorescence detection. Paramagnetic Dynal beads were used as a solid support, primary antibody was attached to the beads by streptavidin-biotin coupling and the secondary antibody had an alkaline phosphatase (AP) enzyme label. Enzymatic conversion of fluorescein diphosphate (FDP) to fluorescein by AP was measured in real time with lambda(ex)= 490 nm and lambda(em)= 520 nm. The assay was linear from 2.6 x 10(3)-5.6 x 10(5) BG spores mL(-1), and the detection limit was 2.6 x 10(3) spores mL(-1) or 78 spores. All reagent concentrations and incubation times were optimized. The assay time from the moment the spores were introduced to the system was 30 min, and real-time fluorescence detection was done in less than 1 min. Formation of the BG spores-capture beads complex was confirmed by environmental scanning electron microscopy (ESEM). BG spores were detected successfully when doped into Cincinnati tap water to demonstrate the applicability of the developed method to detect the spores in non-buffered media.

Animals↗

Bacillus globigii bugbeads: a model simulant of a bacterial spore.

Nonpathogenic microorganisms are often used as simulants of biological pathogens during the initial phase of detection method development. While these simulants approximate the size, shape, and cellular organization of the microorganism of interest, they do not resemble its surface protein content, a factor particularly important in methods based on immunorecognition. Here, we develop and detect an artificial bacterial spore--B. globigii (BG) Bugbead-a particle mimicking the antigenic surface of BG spores. Two methods of spore protein extraction were compared both quantitatively (by protein concentration assay) and qualitatively (by SDS-PAGE and Western blot): extraction by mechanical disruption and extraction by chemical decoating. The former method was more efficient in producing more protein and a greater number of antigens. BG Bugbeads were made by conjugating the extracted proteins to 0.8-microm carboxyl-coated polystyrene particles via carbodiimide coupling. BG Bugbeads were successfully detected by a bead-based enzyme-labeled immunoassay with fluorescence detection with a detection limit of 6.9 x 10(3) particles/mL. Formation of the Bugbead-capture bead complex was confirmed by ESEM. The concept of a harmless artificial spore can be applied to developing improved simulants for pathogenic spore-forming microorganisms such as B. anthracis, C. botulinum, and B. cereus, which can to be used for method validation, instrument calibration, and troubleshooting.

Antigens, Bacterial↗

Estimation of logP(ow) values for neutral and basic compounds by microchip microemulsion electrokinetic chromatography with indirect fluorimetric detection (muMEEKC-IFD).

Microchip microemulsion electrokinetic chromatography with indirect fluorimetric detection (muMEEKC-IFD) was used to obtain logP octanol/water (logP(ow)) values for neutral and basic compounds. Six compounds, with logP(ow) values between 0.38 and 5.03, were used to create a calibration curve relating the log of retention factors (logk) obtained from muMEEKC-IFD with the known logP(ow) values. The logP(ow) values for six additional compounds were determined using the logk values obtained by muMEEKC-IFD and the linear relationship between logP(ow) and logk established for the standard compounds. The muMEEKC-IFD buffer was composed of 50 mM 3-[cyclohexylamino]-1-propane-sulfonic acid (CAPS) buffer (pH 10.4) containing 1.2% n-heptane (v/v), 2% sodium dodecylsulfate (w/v), 8% 1-butanol (v/v) and 4 microM 5-carboxytetramethyl-rhodamine (TAMRA) as the fluorophore probe for indirect detection. The muMEEKC-IFD provided an accurate method for estimating logP(ow) values and also a means for analyzing compounds that are non-fluorescent.

Calibration↗

Rapid pKa estimation using vacuum-assisted multiplexed capillary electrophoresis (VAMCE) with ultraviolet detection.

A rapid approach for estimating the pK(a) value of small organic molecules was developed using vacuum-assisted multiplexed capillary electrophoresis (VAMCE) with ultraviolet detection. The VAMCE method employed a 96-capillary array, arranged in a standard 8 x 12 microtiter plate configuration, with each row of capillaries filled with 12 individual running buffers of equal ionic strength (I = 50 mM) covering a pH range from 2.2 to 10.7. A separate compound was injected hydrodynamically into each row of capillaries allowing the estimation of pK(a) values for eight compounds in a single run. The application of a vacuum during the separation generated a bulk fluid flow and allowed the electrophoretic separation to be completed within 5 min. The complete VAMCE method, conditioning, and electrophoretic separation was optimized to allow the pK(a) estimation for between 128 to 168 compounds in an 8-h period. The VAMCE method provided a reliable approach for estimating pK(a) values both within- and between-day. The pK(a) values for a series of 96 compounds estimated by VAMCE agreed well with some of literature pK(a) values with an average absolute difference of 0.22 log units.

Electrophoresis, Capillary↗

Microfluidic immunosensor systems.

Immunosensing microfluidic devices are reviewed. Devices are commonly fabricated in glass, silicon, and polymers, with polymers seeing greater attention in recent years. Methods have been developed to immobilize antibodies and other molecules and resist non-specific adsorption through surface modification. The most common detection method is fluorescence, followed by electrochemistry. Various microfluidic designs have been reported for immunoassay applications. The observed trends in microfluidic immunoassay applications closely resemble the trends of general immunoassays, where large molecules are detected principally through a sandwich procedure, while competitive assays are used to detect smaller molecules. The following future trends are suggested: more sensitive detection, increased integration and miniaturization, multianalyte analysis, more robust reagents and devices, and increased functionality of surface treatments.

Biosensing Techniques↗

Fabrication of comb interdigitated electrodes array (IDA) for a microbead-based electrochemical assay system.

This research is directed towards developing a more sensitive and rapid electrochemical sensor for enzyme labeled immunoassays by coupling redox cycling at interdigitated electrode arrays (IDA) with the enzyme label beta-galactosidase. Coplanar and comb IDA electrodes with a 2.4 microm gap were fabricated and their redox cycling currents were measured. ANSYS was used to model steady state currents for electrodes with different geometries. Comb IDA electrodes enhanced the signal about three times more than the coplanar IDAs, which agreed with the results of the simulation. Magnetic microbead-based enzyme assay, as a typical example of biochemical detection, was done using the comb and coplanar IDAs. The enzymes could be placed close to the sensing electrodes (approximately 10 microm for the comb IDAs) and detection took less than 1 min with a limit of detection of 70 amol of beta-galactosidase. We conclude that faster and more sensitive assays can be achieved with the comb IDA.

Biosensing Techniques↗

Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 17. Improvement in detection limits using ultrathin perfluorosulfonated ionomer films in conjunction with continuous sample flow.

We report herein an attenuated total reflectance (ATR) absorbance-based spectroelectrochemical sensor for tris(2,2'-bipyridyl)ruthenium(II) ion [Ru(bpy)(3)(2+)] that employs ultrathin (24-50 nm) Nafion films as the charge-selective layer. This film serves to sequester and preconcentrate the analyte at the optically transparent electrode surface such that it can be efficiently detected optically via electrochemical modulation. Our studies indicate that use of ultrathin films in tandem with continuous flow of sample solution through the cell compartment leads to a 100-500-fold enhancement in detection limit (10 nM) compared to earlier absorbance-based spectroelectrochemical sensors ( approximately 1-5 microM); markedly shorter analysis times also result. We report the dependence of the measured absorbance on sample flow rate and Nafion film thickness, and also provide calibration curves that illustrate the linear range and detection limits of the sensor using a 24 nm film at a constant sample flow rate of 0.07 mL/min.

Journal Article↗

Microbead-based electrochemical immunoassay with interdigitated array electrodes.

The objective of this study was to develop a sensitive and miniaturized immunoassay by coupling a microbead-based immunoassay with an interdigitated array (IDA) electrode. An IDA electrode amplifies the signal by recycling an electrochemically redox-reversible molecule. The microfabricated platinum electrodes had 25 pairs of electrodes with 1.6-microm gaps and 2.4-microm widths. An enzyme-labeled sandwich immunoassay on paramagnetic microbeads with mouse IgG as the analyte and beta-galactosidase as the enzyme label was used as the model system. beta-Galactosidase converted p-aminophenyl beta-D-galactopyranoside to p-aminophenol (PAP). This enzyme reaction was measured continuously by positioning the microbeads near the electrode surface with a magnet. Electrochemical recycling occurred with PAP oxidation to p-quinone imine (PQI) at +290 mV followed by PQI reduction to PAP at -300 mV vs Ag/AgCl. Dual-electrode detection amplified the signal fourfold compared to single-electrode detection, and the recycling efficiency reached 87%. A calibration curve of PAP concentration vs anodic current was linear between 10(-4) and 10(-6)M. A signal from 1000 beads in a 20-microL drop was detectable and the immunoassay was complete within 10 min with a detection limit of 3.5x10(-15)mol mouse IgG.

Aminophenols↗