Search PubMed⌕ Search

Biomedical subjects

William D Suggs

Publications and source records attributed to William D Suggs.

15 recordsLinked to original sources

System to decrease length of stay for vascular surgery.

OBJECTIVES: Reduction of length of stay (LOS) is critical for optimal use of hospital resources. We developed and evaluated a system to aggressively reduce LOS for vascular surgery. METHOD: Key to this system, which we introduced on January 1, 2001, was appointment of a LOS officer, who communicated daily during hospitalization with patients and families about discharge planning, organized outpatient services for wound care and rehabilitation to transition patients quickly to nonhospital care, and had biweekly meetings with relevant paramedical services. LOS for 509 patients operated on in 2000 (standard group) was compared with LOS for 474 operated on in 2001 and 595 patients operated on in 2002 (LOS reduction groups). Data for all patients with aortic aneurysm, carotid artery stenosis, lower extremity critical ischemia or amputation, and foot debridement were included. RESULTS: LOS in 2000 averaged 8.5 days, compared with 5.9 days in 2001 and 5.6 days in 2002. All decreases in LOS for each diagnostic category in 2001 and 2002 were statistically significant (P = <.001-.03). There was no significant increase in readmission rate (2.2% vs 1.9% and 2.0%, respectively), mortality rate (0.8% vs 0.6% and 0.7%, respectively), or percent of patients who received endovascular treatment (18% vs 16% and 14%, respectively). These decreases in LOS saved the hospital more than US dollars 616200 in 2001, and US dollars 847550 in 2002 (US dollars 500/patient-day). CONCLUSIONS: A committed LOS officer with major specific daily responsibilities for decreasing LOS and discharging patients resulted in a 31% to 33% decrease in LOS, with important cost savings to the hospital and no negative effect on patient care.

Aged↗

Variability of maximal aortic aneurysm diameter measurements on CT scan: significance and methods to minimize.

OBJECTIVES: We noted substantial differences when measuring repeatedly the same abdominal aortic aneurysm (AAA) on the same computed tomography (CT) scan. This study quantitated this variability, and methods to minimize it were developed. METHODS: The CT maximal diameter of 25 AAAs was measured by eight experienced observers, including six vascular surgeons and two radiologists, using two methods: an unstandardized protocol, and a standardized protocol using fine calipers to carefully measure the largest diameter perpendicular to the estimated aneurysm centerline, from outer aneurysm wall to outer wall. The average measurement difference between observers was calculated for each method. The average difference between each observer's measurement and the official radiology report value was also calculated. Agreement between the two measurement methods was assessed with Bland-Altman plots. RESULTS: The difference in maximal diameter measurements between each observer averaged 4.0 +/- 5.1 mm (range, 0.0-35.0 mm) with the unstandardized method. The mean measurement difference with the standardized protocol was significantly lower, and averaged 2.8 +/- 4.4 mm (range, 0.0-26.0 mm; P<.05). Measurements taken from the official radiology report differed from each of the observer's standardized measurement by an average of 5.0 +/- 6.3 mm (range, 0.0-28.0 mm). This difference was similar for both the unstandardized and standardized methods. Bland-Altman plots confirmed the wide variation of the maximal diameter measurements when the unstandardized method was compared with the standardized method (95% confidence interval, -9-9 mm). CONCLUSIONS: Routine CT maximal diameter measurement of AAAs can have substantial interobserver variability. Standardized measurement protocols can decrease, but not eliminate, this measurement variability. Thus apparent size changes based on CT measurements may represent measurement artifact rather than actual aneurysm growth or shrinkage, particularly when a standardized system is not used.

Aortic Aneurysm, Abdominal↗

Predicting aneurysm enlargement in patients with persistent type II endoleaks.

OBJECTIVE: The clinical significance of type II endoleaks is not well understood. Some evidence, however, indicates that some type II endoleaks might result in aneurysm enlargement and rupture. To identify factors that might contribute to aneurysm expansion, we analyzed the influence of several variables on aneurysm growth in patients with persistent type II endoleaks after endovascular aortic aneurysm repair (EVAR). METHODS: In a series of 348 EVARs performed during a 10-year period, 32 patients (9.2%) developed type II endoleaks that persisted for more than 6 months. Variables analyzed included those defined by the reporting standards for EVAR (SVS/AAVS) as well as other endoleak characteristics. Univariate, receiver operating characteristic curve, and Cox regression analyses were used to determine the association between variables and aneurysm enlargement. RESULTS: The median follow-up period was 26.5 months (range, 6-88 months). Thirteen patients (41%) had aneurysm enlargement by 5 mm or more (median increase in diameter, 10 mm), whereas 19 (59%) had stable or shrinking aneurysm diameter. Univariate and Cox regression analyses identified the maximum diameter of the endoleak cavity, ie, the size of the nidus as defined on contrast computed tomography scan, as a significant predictor for aneurysm enlargement (relative risk, 1.12; 95% confidence interval, 1.04-1.19; P =.001). The median size of the nidus was 23 mm (range, 13-40 mm) in patients with aneurysm enlargement and 8 mm (range, 5-25 mm) in those without expansion (Mann-Whitney U test, P <.001). Moreover, receiver operating characteristic curve and Cox regression analyses showed that a maximum nidus diameter greater than 15 mm was particularly associated with an increased risk of aneurysm enlargement (relative risk, 11.1; 95% confidence interval, 1.4-85.8; P =.02). Other risk factors including gender, smoking history, hypertension, need of anticoagulation, aneurysm diameter, type of endograft used, and number or type of collateral vessels were not significant predictors of aneurysm enlargement. CONCLUSIONS: In patients with persistent type II endoleaks after EVAR, the maximum diameter of the endoleak cavity or nidus is an important predictor of aneurysm growth and might indicate the need for more aggressive surveillance as well as earlier treatment.

Aged↗

Is elevated creatinine level a contraindication to endovascular aneurysm repair?

PURPOSE: It is widely believed that chronic renal insufficiency (CRI) greatly increases the risk associated with endovascular abdominal aortic aneurysm repair (EVAR) and is a relative contraindication to the procedure and to the use of intra-arterial contrast agents (IACA). We reviewed a 5-year EVAR experience to determine whether the procedure and use of IACA have an important deleterious effect on renal function in patients with and without pre-existing CRI. METHODS: Endovascular aneurysm repair (EVAR) was performed in 200 patients with a variety of endografts, with intra-arterial contrast agents. The patients were retrospectively assigned to three groups on the basis of preoperative serum creatinine concentration (Cr): group 1 (n = 108), Cr less than 1.5 mg/dL (normal range); group 2 (n = 65), Cr 1.5 to 2.0 mg/dL; group 3 (n = 27), Cr 2.1 to 3.5 mg/dL. No patients had undergone hemodialysis. In groups 2 and 3, patients received hydration perioperatively, and received mannitol intraoperatively; no nephrotoxic drugs were administered during the procedure, other than nonionic contrast agent (Omnipaque 350). RESULTS: The incidence of postoperative complications between the three study groups was not statistically different. In group 1 a transient increase in serum Cr (>30% over baseline and >1.4 mg/dL) was noted in three patients (2.7%), two of whom (1.9%) required temporary hemodialysis and one (0.9%) who died of renal failure. In group 2 a transient increase in serum Cr was noted in two patients (3.1%); both patients (3.1%) required temporary hemodialysis, and one patient (1.5%) died of renal failure. In group 3 a transient increase in serum Cr was noted in two patients (7.4%); one patient (3.7%) required temporary hemodialysis, and one patient (3.7%) died of renal failure. Perioperative hypotension significantly increased the risk for elevated serum Cr and death (P <.05), and larger contrast volume was associated with an increase in serum Cr (P <.05) during the postoperative period. CONCLUSIONS: EVAR with intra-arterial contrast agents can be accomplished in patients with chronic renal insufficiency who do not require dialysis, with limited and acceptable morbidity and mortality, similar to that observed with open aneurysm repair. Contrary to other reports in which perioperative precautions were not used, our study shows that with EVAR the risk for worsening renal failure, dialysis, and death is only slightly, and not significantly, greater in patients with preoperative chronic renal insufficiency compared with patients with normal renal function. Perioperative hypotension and increased contrast volume are significant risk factors for postoperative increase in serum Cr and death. With appropriate precautions such as averting perioperative hypotension and limiting the volume of nonionic contrast agents, elevated Cr need not be a contraindication to EVAR with intra-arterial contrast agents.

Aged↗

Fate of collateral vessels following subintimal angioplasty.

PURPOSE: To evaluate the fate of collateral vessels adjacent to and within the target lesion following subintimal angioplasty (SIA). METHODS: Pre and postprocedural angiograms were reviewed for 29 patients undergoing SIA of the lower extremity arteries over a 3-year period. The number of patent collateral vessels </=5 cm proximal to the occlusion (proximal segment) and </=5 cm distal to the occlusion (distal segment) were recorded pre and postprocedurally and compared. In addition, the number of collateral vessels that were re-opened within the recanalized segment following SIA was counted. RESULTS: The mean number of patent collaterals in the proximal segment was 1.9 (range 0-4) preprocedurally and 1.4 (range 0-4) postprocedurally (p<0.002). The mean number of patent collaterals in the distal segment was 1.9 (range 0-4) pre-procedurally and 1.0 (range 0-4) postprocedurally (p<0.0001). Previously absent collaterals within the recanalized segment were observed in 4 (14%) of 29 patients post-SIA. The mean number of collateral vessels within all 3 segments (proximal, treated, and distal) was 3.9 collaterals preprocedurally and 2.9 collaterals postprocedurally. CONCLUSIONS: Some collateral vessels are sacrificed during SIA, but the majority are preserved. In addition, SIA has the potential to open new collaterals within the occluded segment. These collaterals may play an important role should restenosis develop within the target segment.

Aged↗

Delayed open conversion following endovascular aortoiliac aneurysm repair: partial (or complete) endograft preservation as a useful adjunct.

OBJECTIVES: The purpose of this study was to review our experience with delayed open conversion (>30 days) following endovascular aortoiliac aneurysm repair (EVAR) and to introduce the concept and advantages of endograft retention in this setting. METHODS: From January 1992 to January 2003, a total of 386 EVARs using a variety of endografts were successfully deployed. Eleven (2.8%) patients required delayed conversion to open repair at an average of 30 months (range, 10-64). Data from all patients undergoing both EVAR and open conversion were prospectively collected. RESULTS: EVARs were performed using grafts made by Talent (4), Vanguard (2,) AneuRx (1), and Surgeon (4). Conversion to open repair (9 transabdominal, 1 retroperitoneal, 1 transabdominal plus thoracotomy) was performed for aneurysm rupture in 7 patients (4 type 1 endoleak, 2 type 2 endoleak, 1 aortoenteric fistula) and aneurysm enlargement in 4 patients (1 type 1 endoleak, 1 type 2 endoleak, 1 type 3 endoleak, 1 endotension). Patients with aneurysm rupture were treated on an emergent basis. Complete removal of the endograft with supraceliac cross-clamping was performed in two cases. One patient (rupture) did not survive the operation, and one patient (aortoenteric fistula) died 2 weeks postoperatively. In the remaining nine cases, the endograft was either completely (1) or partially (6) removed, or left in situ (2). Supraceliac balloon control (2), supraceliac clamping (1), suprarenal clamping (1), or infrarenal clamping (5) was used in these cases. All nine of these patients survived the operation. In one procedure in which the endograft was left intact (endotension), repair was accomplished by exposing the endograft and by placing a standard tube graft over it as a sleeve. In the second procedure in which the graft was left in situ (rupture), the graft was well incorporated, and bleeding lumbar arteries were oversewn and the sac was closed tightly over the endograft. In the remaining 7 cases, the endograft was transected and the proximal portion only (6) or the proximal and distal portions (1) were excised. All surviving patients continue to do well and remain without complications associated with the endograft remnant at a mean follow-up of 22 months (range, 3-56) from the time of open conversion and 46 months (range, 10-73) from the time of original EVAR. CONCLUSIONS: Open repair in the setting of a long-standing endograft offers several unique technical challenges but can be successfully accomplished in most patients. Preservation of all or part of the endograft is possible in many patients. This technique simplifies the operative approach and is preferred over complete endograft removal if possible.

Aged↗

Open aneurysm repair at an endovascular center: value of a modified retroperitoneal approach in patients at high risk with difficult aneurysms.

OBJECTIVE: This study was undertaken to evaluate elective open abdominal aortic aneurysm (AAA) repair and the role of a modified retroperitoneal approach in a high-volume endovascular center. METHODS: We reviewed prospectively collected data for 175 elective infrarenal open AAA repairs performed over 6 years. A transperitoneal approach was used in 118 procedures, and a modified retroperitoneal approach was used in 57 procedures. The incisional modification, which facilitated repair in patients with massive obesity, scarring, or ventral hernia, included a higher, more posterolateral location in the ninth intercostal space. Risk factors that added to the difficulty of the repair included aneurysms with a short (<1 cm) or no aortic neck in 45 patients; large, angled or flared aortic neck in 32 patients;, tortuous and calcified iliac arteries in 6 patients; morbid obesity in 10 patients; low ejection fraction (15%-30%) in 14 patients; chronic obstructive pulmonary disease, with forced expiratory volume at 1 second less than 55% in 4 patients; previous laparotomy in 18 patients; previous left-sided colectomy in 11 patients; large right iliac aneurysm in 8 patients; large ventral hernia in 8 patients; pelvic irradiation in 4 patients; failed endovascular repair in 5 patients; and previous failed open repair attempt in 2 patients. Many of these factors occurred with significantly greater frequency (P =.04-.001) in the retroperitoneal group. All factors were correlated with outcome. RESULTS: Despite these risk factors, overall 30-day mortality was 3.5% (retroperitoneal group, 3.8%), and mean length of hospital stay was 9 days (retroperitoneal group, 8 days). There was no significant correlation between mortality or length of stay and any of the mentioned risk factors (P >.2). CONCLUSION: In the era of endovascular aneurysm exclusion, open AAA repair is generally used to treat anatomically complex or difficult aneurysms, many of which are present in patients at high risk. Despite this combination of anatomic and systemic risk factors, the modified retroperitoneal approach facilitates treatment in difficult circumstances and enables open AAA repair to be performed with acceptable mortality and morbidity.

Academic Medical Centers↗

Does transrenal fixation of aortic endografts impair renal function?

OBJECTIVES: Transrenal fixation (TFX) of aortic endografts is thought to increase the risk for renal infarction and impaired renal function. We studied the late effects of TFX on renal function and perfusion. METHODS: Of 189 patients with commercial aortic endografts, which we inserted between 1995 and 2002, we reviewed data for 130 patients (112 men, 18 women) with available creatinine (Cr) concentration and contrast enhanced computed tomography (CT) scans preoperatively and 1 to 97 months after the procedure. Of the 130 patients, 69 patients had TFX and 61 patients had infrarenal fixation (IFX). Both groups were physiologically comparable. Average age was 76 +/- 8 years for patients with TFX and 75 +/- 8 years for patients with IFX. Presence of renal infarct or renal artery occlusion was determined by nephrograms on serial contrast-enhanced CT scans. RESULTS: Mean follow-up was 17 +/- 16 months (range, 1-54 months) for TFX and 21 +/- 21 months (range, 1-97 months) for IFX. Mean serum Cr concentration increased significantly during long-term follow-up in both groups (TFX, 1.3 +/- 0.5 mg/dL to 1.5 +/- 0.8 mg/dL, P <.01; IFX, 1.3 +/- 0.7 mg/dL to 1.4 +/- 0.8 mg/dL, P <.03). Creatinine clearance (CrCl) similarly decreased over long-term follow-up in both groups (TFX, 53.3 +/- 17.7 mL/min/1.73 m(2) to 47.9 +/- 16.2 mL/min/1.73 m(2), P <.01; IFX, 58.1 +/- 22.7 mL/min/1.73 m(2) to 53.1 +/- 23.4 mL/min/1.73 m(2), P <.02). There were no significant differences in the increase in Cr concentration (P =.19) or decrease in CrCl (P =.68) between TFX and IFX groups. Small renal infarcts were noted in four patients (5.8%) in the TFX group and one patient (1.6%) in the IFX group. No increase in Cr concentration or decrease in CrCl was noted in any patient with a renal infarct. Postoperative renal dysfunction developed in 7 of 69 patients (10.1%) in the TFX group and 7 of 61 patients (11.5%) in the IFX group. There were no statistically significant differences between groups with respect to number of patients with new renal infarcts (P =.37) or postoperative renal dysfunction (P =.81). CONCLUSION: There is a slight increase in serum Cr concentration and decrease in CrCl after aortic endografting. However, there was no significant difference in these changes between patients with TFX and IFX. Although TFX may produce a higher incidence of small renal infarcts, these do not impair renal function. Thus our midterm results suggest that TFX can be performed safely, with no greater change in renal function than observed after IFX.

Aged↗

Treatment of ruptured abdominal aneurysms with stent grafts: a new gold standard?

Ruptured abdominal aortoiliac aneurysms, when treated with open surgical repair, have high morbidity and mortality rates. Since 1994, the authors have used endovascular approaches to treat this entity. Patients with presumed ruptured aortoiliac aneurysms were treated with restricted fluid resuscitation (hypotensive hemostasis), transport to the operating room, placement under local anesthesia of a brachial or femoral guide wire into the supraceliac aorta, and arteriography. If aortoiliac anatomy was suitable, an endovascular graft (stent-graft) repair was performed. If the anatomy was unfavorable, standard open repair was performed. Only if circulatory collapse occurred was a supraceliac balloon placed and inflated using the previously positioned guidewire. Of 35 patients treated in this manner, 29 underwent endovascular graft repair, and 6 required open repair. Four patients died within 30 days (operative mortality rate, 11%). Only 10 patients required supraceliac balloon control. Endovascular grafts, when combined with hypotensive hemostasis and other endovascular techniques including proximal balloon control, may improve treatment outcomes with ruptured abdominal aortoiliac aneurysms. The authors believe these techniques will become widely used for the treatment of ruptured aneurysms.

Angioplasty↗

Endovascular grafts and other catheter-directed techniques in the management of ruptured abdominal aortic aneurysms.

Abdominal aortoiliac aneurysms that are ruptured and treated with open surgical repair have high morbidity and mortality rates. We have employed endovascular approaches to treat this entity since 1994. Patients with presumed ruptured aortoiliac aneurysms were treated with restricted fluid resuscitation (hypotensive hemostasis), transport to the operating room, placement under local anesthesia of a brachial or femoral guidewire into the supraceliac aorta and arteriography. If aortoiliac anatomy was suitable, an endovascular graft repair was performed. If the anatomy was unfavorable, the aneurysm was repaired in a standard open fashion. Only if circulatory collapse occurred was a supraceliac balloon placed and inflated using the previously positioned guidewire. Of 36 patients so managed, 30 underwent endovascular graft repair and six required open repair. Four patients died within 30 days (operative mortality = 11%). Only 10 patients required supraceliac balloon control. Endovascular grafts, when combined with hypotensive hemostasis and other endovascular techniques, including proximal balloon control, may improve treatment outcomes with ruptured abdominal aortoiliac aneurysms. These techniques should become widely used for the treatment of ruptured aneurysms.

Aneurysm, Ruptured↗

Does subintimal angioplasty have a role in the treatment of severe lower extremity ischemia?

OBJECTIVE: Subintimal angioplasty (SIA) has been advocated to treat long segment lower extremity arterial occlusions, but many question its value. We evaluated the role of SIA in a group of patients with severe lower extremity arterial occlusive disease. METHODS: During a 2.5-year period, 39 patients with arterial occlusions (median length, 8 cm; range, 2 to 31 cm) were treated on an intention-to-treat basis with SIA. Twenty-five patients had gangrene, five had rest pain, and nine had disabling (<one block) claudication. There were 24 superficial femoral, two superficial-femoral-popliteal, four popliteal, two popliteal-tibial, five tibial, and two external iliac artery lesions. With fluoroscopic guidance, via a prograde common femoral artery puncture (n = 29) or a contralateral common femoral artery puncture (n = 9), a subintimal dissection plane was created across the occlusion with a standard guidewire and catheter. The arterial lumen was reentered distal to the occlusion, and the recanalized segment balloon was dilated. All patients were followed prospectively with arterial duplex scan. RESULTS: SIA was technically successful in 34 of 39 patients (87%). All five failures were from an inability to reenter the patent lumen distally. These five patients underwent successful bypasses that in no case were more distal than would have been required before SIA. In the 34 technically successful SIAs, pain completely resolved (14/14) and areas of gangrene (21/25) healed. The cumulative patency rate in patients who underwent successful SIA was 74% +/- 10% at 12 months. The mean increase in ankle-brachial index after SIA was 0.34 (range, 0.1 to 0.69). There were two distal embolic events, successfully treated surgically (n = 1) or with catheter-directed techniques (n = 1). Three patients underwent subsequent bypass, and the remaining five patients remain asymptomatic. CONCLUSION: SIA is feasible and can be effective in some patients with lower extremity arterial occlusions and threatened limbs. These results, plus SIA's many advantages, support an increasing role for it in the treatment of lower extremity arterial occlusive disease.

Aged↗

Patency rates of femorofemoral bypasses associated with endovascular aneurysm repair surpass those performed for occlusive disease.

PURPOSE: To evaluate the patency rates of femorofemoral grafts performed in conjunction with aortomonoiliac or aortomonofemoral (AMI/F) endografts. METHODS: Over the past 8 years, 110 patients (98 men; mean age 77+/-7 years, range 57-90) underwent aortoiliac aneurysm repair with an AMI/F endograft. Follow-up data in these patients were prospectively collected for a mean 2.3 years (range 1-68 months). RESULTS: There were 2 early (<7 days) AMI/F endograft thromboses with secondary femorofemoral graft occlusion. In both patients, patency of all grafts was restored by thrombectomy plus stenting of the endograft. Three late (4, 5, and 10 months) AMI/F endograft thromboses led to femorofemoral graft failure; 2 were successfully treated, but the third patient refused further intervention. No femorofemoral bypass failed in the absence of AMI/F endograft thrombosis. There were no femorofemoral graft infections. Four-year life-table primary and secondary patency rates were 95% and 99%, respectively. CONCLUSIONS: Femorofemoral bypasses with AMI/F endografts for aneurysmal disease are durable procedures and have better patency than femorofemoral grafts used to treat occlusive disease. Femorofemoral bypass patency rates alone are not a disadvantage of aortomonoiliac endografts.

Aged↗

Nonoperative management with selective delayed surgery for large abdominal aortic aneurysms in patients at high risk.

OBJECTIVE: An accepted fact is that abdominal aortic aneurysms (AAAs) larger than 5.5 cm should undergo elective repair. However, subsets of these patients have serious comorbid conditions, which greatly increase operative risk. This study evaluated the outcomes of periods of protracted nonoperative observational management with selective delayed surgery in patients at high risk with large infrarenal and pararenal AAAs. METHODS: Among 226 patients with AAAs more than 5.5 cm, we selected 72 with AAAs from 5.6 to 12.0 cm (mean, 7.0 cm) for periods of nonoperative management because of their prohibitive surgical risks. Comorbid factors included a low ejection fraction of 15% to 34% (mean, 22%) in 18 patients, 1 second forced expiratory volume less than 50% (mean, 38%) in 25, prior laparotomy in 10, and morbid obesity in 22. Follow-up examination was complete in the 72 patients for the 6 to 76 months (mean, 23 months) that they underwent nonoperative treatment. Fifty-three patients ultimately underwent operation because of AAA enlargement or onset of symptoms after 6 to 72 months (mean, 19 months) of nonoperative treatment. RESULTS: Of the 72 selected patients, 54 (75%) are living and 18 (25%) are dead. Seven patients who underwent only nonoperative treatment presently survive after 28 to 76 months (mean, 48 months). Of the 18 deaths, AAA rupture occurred in only three patients (4%) who were observed for 12, 31, and 72 months before rupture. Nine other deaths (13%) occurred after 6 to 72 months from comorbidities unrelated to the AAA. Six of the 53 patients who underwent delayed operation died within 30 days of operation (11% mortality rate). The mortality rate for the 154 good-risk patients with an AAA who underwent prompt open or endovascular repair was 2.2%. CONCLUSION: These data indicate that some patients with large AAAs and serious comorbidities are acceptably managed for long periods (6 to 76 months) with nonoperative means. Substantial delays of 12 to 76 months resulted in an AAA rupture rate of only 4%, and 13% of these patients (nine of 72) died of comorbidities unrelated to AAA rupture or surgery. Mortality rate in this group of patients, when operated, was 11% (six of 53). These findings support the selective use of nonoperative management in some patients with large AAAs and serious comorbidities.

Aged↗

Initial experience with cerebral protection devices to prevent embolization during carotid artery stenting.

OBJECTIVE: Carotid artery stenting (CAS) for treatment of carotid stenosis has not received wide acceptance because of the availability of carotid endarterectomy (CEA) with its excellent results and because of the risk of embolic stroke associated with CAS. The feasibility and efficacy of cerebral protection devices that may prevent such embolic complications have yet to be shown. We report our initial results with CAS performed with cerebral protection. METHODS: For a period of 28 months, 31 patients with carotid artery stenosis, most of whom were considered at high risk for CEA (87%), underwent treatment with CAS in conjunction with either the PercuSurge GuardWire (n = 19; Medtronic, Minneapolis, Minn), the Cordis Angioguard filter (n = 7; Cordis, Warren, NJ), or the ArteriA Parodi Anti-embolization catheter (n = 4; ArteriA, San Francisco, Calif) with US Food and Drug Administration-approved investigational device exemptions. Factors that made CEA high risk included restenosis after CEA (n = 6), hostile neck (n = 6), high or low lesions (n = 4), and severe comorbid medical conditions (n = 11). Preoperative neurologic symptoms were present in 58%, and the mean stenosis was 85% +/- 12%. Data were prospectively recorded and analyzed on an intent-to-treat basis. Neurologic evaluation was performed before and after CAS by a protocol neurologist. RESULTS: CAS was performed with local anesthesia with the Wallstent (n = 23; Boston Scientific Corp, Natick, Mass) or the PRECISE carotid stent (n = 7; Cordis) in conjunction with one of the protection devices in an operating room with a mobile C-arm. Each patient received dual antiplatelet therapy before surgery. The overall technical success rate was 97% (30/31). In one patient, the lesion could not be crossed with a guidewire because of a severely stenosed and tortuous lesion. This patient was not a candidate for CEA and was treated conservatively. In the remaining 30 cases, CAS had a good angiographic result (residual stenosis, <10%). All patients tolerated the protection device well, and no intraprocedural neurologic complications occurred. Macroscopic embolic particles were recovered from each case. One patient (3%) with a severely tortuous vessel had a major stroke immediately after CAS, and no deaths occurred. The combined 30 day stroke/death rate was 3%. During a mean follow-up period of 17 months, one subacute occlusion of the stent occurred but did not result in a stroke. Three other patients had duplex scan-proven in-stent restenosis, and two underwent treatment with repeat percutaneous transluminal angioplasty with a good result. No patient had a stroke during the follow-up period. CONCLUSION: CAS with cerebral protection devices can be performed safely with a high technical success rate. Although many patients who underwent treatment with CAS were at high risk, the neurologic complication rate was low and CAS appears to be an acceptable treatment option for select patients at high risk for CEA. Tight lesions and tortuous anatomy may make the use of distal protection devices difficult. Further study is warranted.

Aged↗

Spontaneous recanalization of arterial occlusions: an unusual mechanism for symptomatic improvement.

OBJECTIVE: Patients with infrainguinal occlusive disease may experience spontaneous symptomatic improvement. This is generally thought to be from augmented collateral circulation. This study reports another mechanism. METHODS: Over a 20-year period, 4123 patients underwent lower extremity arteriography for limb ischemia. For a variety of reasons, 451 patients had repeat arteriography. RESULTS: Five patients were identified as having conclusive arteriographic evidence of spontaneous recanalization of occluded arterial segments without having undergone any surgical or thrombolytic interventions. Repeat contrast arteriography was performed on these patients for failing grafts (n = 2) or contralateral lower extremity ischemia (n = 3). Three other patients had magnetic resonance arteriographic or duplex arteriographic evidence of spontaneous arterial recanalization. Spontaneous recanalizaton occurred in ileofemoral (n = 2), superficial femoral (n = 2), popliteal (n = 3), and peroneal (n = 1) arterial segments. The average time interval of occlusion to recanalization was 21 weeks (2 weeks to 2 years). Two of the eight patients had failed revascularization procedures before spontaneous recanalization. All eight patients had restoration of pulses distal to the recanalized segments and significant symptomatic improvement as defined with the Society for Vascular Surgery/American Association for Vascular Surgery categories for limb ischemia. CONCLUSION: Spontaneous recanalization of arterial segments can occur and must be considered when evaluating other proposed treatments of critical limb ischemia, including cilostazol, lytic agents, and angiogenic agents, such as vascular endothelial growth factor. Although its true incidence is unknown, this represents another mechanism for spontaneous symptomatic improvement without treatment in patients with severe limb ischemia.

Aged↗