Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique.

The purpose was to evaluate the potential of the multidimensional adaptive filtering (MAF) technique by investigating its effects on image noise and image quality in multislice spiral CT (MSCT) examinations of the head and neck region. Fifty patients with head and neck tumors were examined using MSCT with a high resolution protocol. Reconstructions were performed using dedicated reconstruction software with a standard algorithm both without and with MAF using different modification. In all reconstructions, we measured the noise in seven different anatomical structures. The image quality and image noise were rated on a five-point scale. There was a significant (P<0.05) reduction in mean pixel noise in the reconstructions using MAF in comparison to the standard reconstructions, but there was no significant difference between the different modification fractions. With MAF the mean reduction in noise level was 60%, depending upon body shape and anatomical region. Independently from the used modification fraction, MAF led to a significant (P<0.05) improvement of image quality. In direct comparison of the different filter strength, the optimal image quality was achieved in the investigations with 15% MAF. The use of MAF facilitates the distinction of anatomical and pathological structures from artifacts in the supraclavicular fossae and the upper mediastinum, whereas the image quality of the upper portions of the neck remained unchanged. MAF improved image quality by reducing the noise level and removing noise structures without loss of image sharpness. This technique offers new perspectives to reduce the patient dose.

Adipose Tissue↗

A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images.

The purpose of this study was to improve metal artifact reduction (MAR) in X-ray computed tomography (CT) by the combination of two artifact reduction methods. The presented method constitutes an image-based weighted superposition of images processed with two known methods for MAR: linear interpolation of reprojected metal traces (LI) and multi-dimensional adaptive filtering of the raw data (MAF). Two weighting concepts were realized that take into account mean distances of image points from metal objects or additional directional components. Artifact reduction on patient data from the jaw and the hip region shows that although the application of only one of the MAR algorithms can already improve image quality, these methods have specific drawbacks. While MAF does not correct corrupted CT values, LI often introduces secondary artifacts. The corrective impact of the merging algorithm is almost always superior to the application of only one of the methods. The results obtained with directional weighting are equal to or in many cases better than those of the distance weighting scheme. Merging combines the advantages of two fundamentally different approaches to artifact reduction and can improve the quality of images that are affected by metal artifacts.

Algorithms↗

Interactive 3D editing tools for image segmentation.

Segmentation is an important part of image processing, which often has a large impact on quantitative image analysis results. Fully automated operator independent segmentation procedures that successfully work in a population with a larger biological variation are extremely difficult to design and usually some kind of operator intervention is required, at least in pathological cases. We developed a variety of 3D editing tools that can be used to correct or improve results of initial automatic segmentation procedures. Specifically we will discuss and show examples for three types of editing tools that we termed: hole-filling (tool 1), point-bridging (tool 2), and surface-dragging (tool 3). Each tool comes in a number of flavors, all of which are implemented in a truly 3D manner. We describe the principles, evaluate efficiency and flexibility, and discuss advantages and disadvantages of each tool. We further demonstrate the superiority of the 3D approach over the time-consuming slice-by-slice editing of 3D datasets, which is still widely used in medical image processing today. We conclude that performance criteria for automatic segmentation algorithms may be eased significantly by including 3D editing tools early in the design process.

Algorithms↗

Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage.

We have developed a new approximate Feldkamp-type algorithm that we call the extended parallel backprojection (EPBP). Its main features are a phase-weighted backprojection and a voxel-by-voxel 180 degrees normalization. The first feature ensures three-dimensional (3-D) and 4-D capabilities with one and the same algorithm; the second ensures 100% detector usage (each ray is accounted for). The algorithm was evaluated using simulated data of a thorax phantom and a cardiac motion phantom for scanners with up to 256 slices. Axial (circle and sequence) and spiral scan trajectories were investigated. The standard reconstructions (EPBPStd) are of high quality, even for as many as 256 slices. The cardiac reconstructions (EPBPCI) are of high quality as well and show no significant deterioration of objects even far off the center of rotation. Since EPBPCI uses the cardio interpolation (CI) phase weighting the temporal resolution is equivalent to that of the well-established single-slice and multislice cardiac approaches 180 degrees CI, 180 degrees MCI, and ASSRCI, respectively, and lies in the order of 50 to 100 ms for rotation times between 0.4 and 0.5 s. EPBP appears to fulfill all required demands. Especially the phase-correlated EPBP reconstruction of cardiac multiple circle scan data is of high interest, e.g., for dynamic perfusion studies of the heart.

Algorithms↗

The Erlangen Fitness Osteoporosis Prevention Study: a controlled exercise trial in early postmenopausal women with low bone density-first-year results.

OBJECTIVE: To investigate the effect of a 2-year vigorous, combined high-impact, strength, and endurance training program on bone mineral density (BMD) determined by dual-energy x-ray absorptiometry (DXA), quantitative computed tomography (QCT), and ultrasound in early postmenopausal women with osteopenia. DESIGN: Nonrandomized controlled trial, reporting 1-year data. SETTING: Community. PARTICIPANTS: Early postmenopausal (1-8y postmenopausal) osteopenic women (DXA T score at lumbar spine or total hip between -1 and -2.5 standard deviations). The exercise group (n=59; mean age, 55.1+/-3.4y) and control group (n=41; mean age, 55.9+/-3.1y) were recruited from community registers. INTERVENTION: Fourteen months of exercise training, with 2 joint sessions and 2 additional home training sessions. Exercise and control groups were supplemented individually with calcium and cholecalciferol up to 1500mg of calcium and 500IU of vitamin D per day. MAIN OUTCOMES MEASURES: BMD at the lumbar spine and total hip measured by DXA, isometric maximum strength, and maximal oxygen consumption (VO2max) during a stepwise running test to exhaustion. RESULTS: Bone density increased significantly at the lumbar spine for the exercise group (1.3%, P<.001) and decreased in the control group (-1.2%, P<.01). Differences at the total hip (-0.3%, not significant vs -0.8%, P<.05) and the femoral neck (-0.8%, P<.05 vs -1.8%, P<.001) were nonsignificant. Changes in isometric maximum strength were significant for each region (grip strength, trunk flexors and extensors, hip flexors, leg adductors and abductors, arm flexors and extensors) in the exercise group (11%-39%) compared with nonrelevant changes (-1.1% to 3.9%) in the control group. Between-group differences were significant (P<.01-.001) for all strength parameters. VO2max increased significantly by 11% (P<.001) in the exercise group but decreased in the control group by 4% (P<.05) while showing significant between-group differences. CONCLUSION: High-intensity exercise training can have a positive influence on bone density in early postmenopausal osteopenic women.

Absorptiometry, Photon↗

[Advanced method for calculating the scatter signal contribution in CT detectors by the Monte Carlo method].

Multislice spiral CT scanners allow to acquire multiple slices simultaneously. With increasing numbers of slices, not only the total extent of slice collimation increases, but also the contribution of scatter radiation to the detector signal. A fast method for calculating the scatter signal would offer the possibility to correct the measured detector signal. Monte Carlo methods allow to simulate the paths of photons through a 3D volume, both in a patient- and scanner-specific fashion. If a scatter photon leaves the volume, its path can be followed and its interaction with an element of the detector be checked. This conventional way of calculating the scatter signal is time-consuming. In order to reduce the calculation time, a more efficient method was developed (Method of Weights). Every time an interaction occurs inside of the 3D volume, the probability of a detector hit due to photon scattering is calculated for each detector channel. The respective value is added to the scatter signal per detector with the corresponding weight. Simulated values of scatter-to-primary-signal ratios were confirmed by data available in the literature. Both the conventional and fast methods for the calculation of scatter signals yielded identical values within the range of statistical accuracy. Assuming the same computing time, the standard deviation for the conventional method was 5 times higher than for the fast one. The presented method allows to significantly reduce the computation time. It may therefore provide a basis for "real time" methods to correct for the scatter signal, especially in case of increasing numbers of slices.

Humans↗

Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography.

RATIONALE AND OBJECTIVES: To compare the image quality of electron beam tomography (EBT) and multislice spiral CT (MSCT) for coronary artery visualization. MATERIALS AND METHODS: Two groups of 30 patients without coronary stenoses were studied by MSCT (4 x 1 mm collimation) or EBT (3 mm slice thickness). Contrast-to-noise ratio (CNR), overall length of the visualized arteries and vessel length free of motion artifacts were measured. RESULTS: Length of visualized arteries was equal in MSCT and EBT. In EBT, longer segments were depicted free of motion artifacts (MSCT: 73%, EBT: 92% of visualized length, P< 0.001) and CNR was significantly higher than in MSCT (15.4 vs. 9.0; P< 0.001). In both modalities, vessel diameters correlated closely to quantitative coronary angiography. CONCLUSIONS: EBT and MSCT permit reliable coronary artery visualization and measurement of vessel diameters. For the used scan protocol, MSCT images had a lower CNR and were more frequently affected by motion.

Aged↗

A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data.

We developed a highly automated three-dimensionally based method for the segmentation of bone in volumetric computed tomography (CT) datasets. The multistep approach starts with three-dimensional (3-D) region-growing using local adaptive thresholds followed by procedures to correct for remaining boundary discontinuities and a subsequent anatomically oriented boundary adjustment using local values of cortical bone density. We describe the details of our approach and show applications in the proximal femur, the knee, and the skull. The accuracy of the determination of geometrical parameters was analyzed using CT scans of the semi-anthropomorphic European spine phantom. Depending on the settings of the segmentation parameters cortical thickness could be determined with an accuracy corresponding to the side length of 1 to 2.5 voxels. The impact of noise on the segmentation was investigated by artificially adding noise to the CT data. An increase in noise by factors of two and five changed cortical thickness corresponding to the side length of one voxel. Intraoperator and interoperator precision was analyzed by repeated analysis of nine pelvic CT scans. Precision errors were smaller than 1% for trabecular and total volumes and smaller than 2% for cortical thickness. Intraoperator and interoperator precision errors were not significantly different. Our segmentation approach shows: 1) high accuracy and precision and is 2) robust to noise, 3) insensitive to user-defined thresholds, 4) highly automated and fast, and 5) easy to initialize.

Algorithms↗

Forensic microradiology: micro-computed tomography (Micro-CT) and analysis of patterned injuries inside of bone.

When a knife is stabbed in bone, it leaves an impression in the bone. The characteristics (shape, size, etc.) may indicate the type of tool used to produce the patterned injury in bone. Until now it has been impossible in forensic sciences to document such damage precisely and non-destructively. Micro-computed tomography (Micro-CT) offers an opportunity to analyze patterned injuries of tool marks made in bone. Using high-resolution Micro-CT and computer software, detailed analysis of three-dimensional (3D) architecture has recently become feasible and allows microstructural 3D bone information to be collected. With adequate viewing software, data from 2D slice of an arbitrary plane can be extracted from 3D datasets. Using such software as a "digital virtual knife," the examiner can interactively section and analyze the 3D sample. Analysis of the bone injury revealed that Micro-CT provides an opportunity to correlate a bone injury to an injury-causing instrument. Even broken knife tips can be graphically and non-destructively assigned to a suspect weapon.

Animals↗

Assessment of calcium scoring performance in cardiac computed tomography.

Electron beam tomography (EBT) has been used for cardiac diagnosis and the quantitative assessment of coronary calcium since the late 1980s. The introduction of mechanical multi-slice spiral CT (MSCT) scanners with shorter rotation times opened new possibilities of cardiac imaging with conventional CT scanners. The purpose of this work was to qualitatively and quantitatively evaluate the performance for EBT and MSCT for the task of coronary artery calcium imaging as a function of acquisition protocol, heart rate, spiral reconstruction algorithm (where applicable) and calcium scoring method. A cardiac CT semi-anthropomorphic phantom was designed and manufactured for the investigation of all relevant image quality parameters in cardiac CT. This phantom includes various test objects, some of which can be moved within the anthropomorphic phantom in a manner that mimics realistic heart motion. These tools were used to qualitatively and quantitatively demonstrate the accuracy of coronary calcium imaging using typical protocols for an electron beam (Evolution C-150XP, Imatron, South San Francisco, Calif.) and a 0.5-s four-slice spiral CT scanner (Sensation 4, Siemens, Erlangen, Germany). A special focus was put on the method of quantifying coronary calcium, and three scoring systems were evaluated (Agatston, volume, and mass scoring). Good reproducibility in coronary calcium scoring is always the result of a combination of high temporal and spatial resolution; consequently, thin-slice protocols in combination with retrospective gating on MSCT scanners yielded the best results. The Agatston score was found to be the least reproducible scoring method. The hydroxyapatite mass, being better reproducible and comparable on different scanners and being a physical quantitative measure, appears to be the method of choice for future clinical studies. The hydroxyapatite mass is highly correlated to the Agatston score. The introduced phantoms can be used to quantitatively assess the performance characteristics of, for example, different scanners, reconstruction algorithms, and quantification methods in cardiac CT. This is especially important for quantitative tasks, such as the determination of the amount of calcium in the coronary arteries, to achieve high and constant quality in this field.

Calcinosis↗

Exercise effects on fitness and bone mineral density in early postmenopausal women: 1-year EFOPS results.

PURPOSE: To determine the effect of an intense exercise training on physical fitness, coronary heart disease (CHD), bone mineral density (BMD), and parameters related to quality of life in early postmenopausal women with osteopenia. METHODS: Fifty-nine fully compliant women (55.1 +/- 3.4 yr) without any medication or illness affecting bone metabolism took part in intensive exercise training (>2 sessions per week); 41 women served as nontraining control. Both groups received calcium and vitamin D (cholecalciferol) up to a maximum of 1500 mg x d(-1) calcium and 500 IU x d(-1) vitamin D. Bone density of the lumbar spine and hip (DXA Hologic QDR 4500), maximum isometric and dynamic strength (Schnell M3, Schnell-Trainer), VO2max (ZAN 600), and quality of life parameters including vasomotor symptoms related to menopause were measured at baseline and after 14 months. RESULTS: After 14 months, there were significant differences between exercise and control groups concerning changes of bone density (LS exercise: +1.3%, P < 0.001 vs control: -1.2%, P < 0.001), maximum isometric strength (exercise: +11 to +32% (P < 0.001) vs control: -1.1 to +3.9%), VO2max (exercise: +11% (P < 0.001) vs control: -4% (P < 0.05)), and quality of life parameters (e.g., lower back pain). Dynamic strength (1RM tests) at four exercises, which was assessed in the exercise group only, increased significantly by 15-43% (all P < 0.001). CONCLUSION: The intense exercise training program presented here was effective in improving strength, endurance, quality of life parameters, and even BMD in women in their critical early postmenopausal years.

Bone Density↗

Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 degrees MCD and 180 degrees MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorithms provided by the CT manufacturers, high image quality can be achieved. These algorithms require information about the cardiac motion, i.e., typically the simultaneously recorded electrocardiogram (ECG), to synchronize the reconstruction with the cardiac motion. Neither data acquired without ECG information (standard patients) nor acquisitions with corrupted ECG information can be handled adequately. We developed a method to extract the appropriate information about cardiac motion directly from the measured raw data (projection data). The so-called kymogram function is a measure of the cardiac motion as a function of time t or as a function of the projection angle alpha. In contrast to the ECG which is a global measure of the heart's electric excitation, the kymogram is a local measure of the heart motion at the z-position z(a) at projection angle a. The patient's local heart rate as well as the necessary synchronization information to be used with phase-correlated algorithms can be extracted from the kymogram by using a series of signal processing steps. The kymogram information is shown to be adequate to substitute the ECG information. Computer simulations with simulated ECG and patient measurements with simultaneously acquired ECG were carried out for a multislice scanner providing M = 4 slices to evaluate these new approaches. Both the ECG function and the kymogram function were used for reconstruction. Both were highly correlated regarding the periodicity information used for reconstruction. In 21 out of 25 consecutive cases the kymogram approach was equivalent to the ECG-correlated reconstruction; only minor differences in image quality between both methods were observed. For one patient the synchronization information detected by the ECG monitor turned out to be wrong; here, the kymogram constituted the only approach that provided useful reconstructions. Patient studies with 12 and 16 slices indicate the usefulness of our approach for cone-beam CT scans. Kymogram-correlated reconstructions also appear to have the potential to improve imaging of pericardial lung areas in general.

Algorithms↗

Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection.

OBJECTIVE: Although multidetector CT (MDCT) with retrospectively ECG-gated image reconstruction has been shown to permit noninvasive visualization of the coronary arteries, the 125-250 msec required for image acquisition frequently causes motion artifacts. We investigated the influence of a patient's heart rate on the presence of motion artifacts and on accuracy of stenosis detection on contrast-enhanced MDCT. MATERIALS AND METHODS: In 100 patients, MDCT was performed, and ECG-gated cross-sectional images were retrospectively reconstructed. From the 10 data sets obtained for each patient (reconstructed at 0-90% of the cardiac cycle in increments of 10%), we chose the best data set for every coronary artery. The images of the arteries were evaluated for occurrence of artifacts and the presence of high-grade stenosis (diameter reduction exceeding 70%) or occlusions. MDCT results were compared with coronary angiographic findings. RESULTS: Of the 400 coronary arteries, 115 (29%) could not be evaluated because of motion artifacts (n = 84) or other reasons (n = 31). Overall, 51 (49%) of 104 stenoses were revealed on MDCT. For detecting stenosis in those arteries that we could evaluate, MDCT had a sensitivity of 91% (51 of 56 stenoses detected) and a specificity of 89%. As the heart rate increased, the number of arteries that could be evaluated decreased, and overall sensitivity for stenosis detection decreased from 62% (heart rate < or = 70 beats per minute) to 33% (heart rate > 70 beats per minute). CONCLUSION: MDCT can reveal coronary stenoses, but the usefulness of MDCT as an aid in accurately evaluating stenoses decreases as a patient's heart rate increases.

Adult↗

An extensible software-based platform for reconstruction and evaluation of CT images.

A collection of software applications dedicated to clinical x-ray computed tomography (CT) has been developed. These tools are designed for routine and scientific work and represent a complete platform, which is called syngo Explorer. The user can reconstruct, process, and view CT images in a personal computer environment independently of specialized hardware. To manage patient data and to allow full database access, the system uses the syngo platform (Siemens Medical Solutions, Erlangen, Germany), which serves as a framework for the management and visualization of Digital Imaging and Communications in Medicine (DICOM) images. Part of the philosophy behind syngo Explorer is to quickly provide specialized solutions and to be able to respond to user requests at once. Thus, syngo Explorer was built by choosing a modular setup that comprises standard and specific reconstruction algorithms as well as various artifact reduction techniques; it also helps one attain better insights into dose issues. Various raw data formats of commercial CT scanners are supported. Reconstruction algorithms equivalent to those on the manufacturer's scanner console are provided. A non-syngo Windows XP (Microsoft, Redmond, Wash) version of the application is available.

Algorithms↗