Search PubMed⌕ Search

Biomedical subjects

Wilfried M A Niessen

Publications and source records attributed to Wilfried M A Niessen.

10 recordsLinked to original sources

Analytical separation and detection methods for flavonoids.

Flavonoids receive considerable attention in the literature, specifically because of their biological and physiological importance. This review focuses on separation and detection methods for flavonoids and their application to plants, food, drinks and biological fluids. The topics that will be discussed are sample treatment, column liquid chromatography (LC), but also methods such as gas chromatography (GC), capillary electrophoresis (CE) and thin-layer chromatography (TLC), various detection methods and structural characterization. Because of the increasing interest in structure elucidation of flavonoids, special attention will be devoted to the use of tandem-mass spectrometric (MS/MS) techniques for the characterization of several important sub-classes, and to the potential of combined diode-array UV (DAD UV), tandem-MS and nuclear magnetic resonance (NMR) detection for unambiguous identification. Emphasis will be on recent developments and trends.

Beverages↗

High-temperature liquid chromatography coupled on-line to a continuous-flow biochemical screening assay with electrospray ionization mass spectrometric detection.

The potential of high-temperature liquid chromatography (HTLC) was investigated in an on-line combination with a screening system for bioactive compounds against the enzyme cathepsin B. Samples were separated by HTLC and subsequently analyzed by an on-line continuous-flow enzymatic assay. Detection was performed by electrospray ionization mass spectrometry, revealing both the bioactivity and the molecular mass of the bioactive compounds. Compared to conventional reversed-phase liquid chromatography, the amount of methanol necessary for separation could be decreased to only 10%, which improved the compatibility of LC with a biochemical assay. Sufficient preheating of the mobile phase prior to the separation and postcolumn cooling to prevent deactivation of the enzyme, even at column temperatures as high as 208 degrees C, was achieved as indicated by the reliable peak shapes obtained. The sensitivity was comparable with previously described systems operating at ambient temperatures as similar IC50 values were obtained. Exposing the inhibitors to high temperatures did not lead to thermal decomposition. The separation of inhibitors and the subsequent biochemical assay was performed either isothermally at various temperatures or by applying various temperature gradients as well as at various flow rates. The results obtained clearly show the compatibility of HTLC with an enzymatic screening assay.

Cathepsin B↗

Selective quantitative bioanalysis of proteins in biological fluids by on-line immunoaffinity chromatography-protein digestion-liquid chromatography-mass spectrometry.

A quantitative method for the determination of proteins in complex biological matrices has been developed based on the selectivity of antibodies for sample purification followed by proteolytic digestion and quantitative mass spectrometry. An immunosorbent of polyclonal anti-bovine serum albumin (BSA) antibodies immobilized on CNBR agarose is used in the on-line mode for selective sample pretreatment. Next, the purified sample is trypsin digested to obtain protein specific peptide markers. Subsequent analysis of the peptide mixture using a desalination procedure and a separation step coupled, on-line to an ion-trap mass spectrometer, reveals that this method enables selective determination of proteins in biological matrices like diluted human plasma. This approach enhances substantially the selectivity compared to common quantitative analysis executed with immunoassays and colorimetry, fluorimetry or luminescence detection. Hyphenation of the immunoaffinity chromatography with on-line digestion and chromatography-mass spectrometry is performed and a completely on-line quantification of the model protein BSA in bovine and human urine was established. A detection limit of 170 nmol/l and a quantification limit of 280 nmol/l is obtained using 50 microl of either standard or spiked biological matrix. The model system allows fully automated absolute quantitative mass spectrometric analysis of intact proteins in biological matrices without time-consuming labeling procedures.

Animals↗

A microfluidic-based enzymatic assay for bioactivity screening combined with capillary liquid chromatography and mass spectrometry.

The design and implementation of a continuous-flow microfluidic assay for the screening of (complex) mixtures for bioactive compounds is described. The microfluidic chip featured two microreactors (1.6 and 2.4 microL) in which an enzyme inhibition and a substrate conversion reaction were performed, respectively. Enzyme inhibition was detected by continuously monitoring the products formed in the enzyme-substrate reaction by electrospray ionization mass spectrometry (ESI-MS). In order to enable the screening of mixtures of compounds, the chip-based assay was coupled on-line to capillary reversed-phase high-performance liquid chromatography (HPLC) with the HPLC column being operated either in isocratic or gradient elution mode. In order to improve the detection limits of the current method, sample preconcentration based on a micro on-line solid-phase extraction column was employed. The use of electrospray MS allowed the simultaneous detection of chemical (MS spectra) and biological parameters (enzyme inhibition) of ligands eluting from the HPLC column. The present system was optimized and validated using the protease cathepsin B as enzyme of choice. Inhibition of cathepsin B is detected by monitoring three product traces, obtained by cleavage of the substrate. The two microreactors provided 32 and 36 s reaction time, respectively, which resulted in sufficient assay dynamics to enable the screening of bioactive compounds. The total flow rate was 4 microL min-1, which a 25-fold decrease was compared with a macro-scale system described earlier. Detection limits of 0.17-2.6 micromol L-1 were obtained for the screening of inhibitors, which is comparable to either microtiter plate assays or continuous-flow assays described in the literature.

Cathepsin B↗

On-line coupling of high-performance liquid chromatography to a continuous-flow enzyme assay based on electrospray ionization mass spectrometry.

Liquid chromatography (LC) was coupled on-line to a continuous-flow enzymatic assay using electrospray ionization mass spectrometry (ESI-MS) as readout for the screening of enzyme inhibitors in complex samples. Inhibitors were detected by changes in the concentration of the enzymatic reaction products, indicating the inhibition of enzymatic activity. The molecular masses of the inhibitors were determined with high certainty by using retention time matching and peak shape comparison. Due to the high matching accuracy, baseline separation of coeluting analytes was not necessary in order to identify the correct masses of the bioactive compounds. The continuous-flow system was successfully applied for the screening of complex samples, such as natural extracts. For a red clover extract, detection limits of 0.3-0.8 micromol/L were obtained. System validation was performed by determining the IC(50) values of four inhibitors in the flow-injection mode. The IC(50) values were in the 0.11-5.6 micromol/L range and correspond closely to data obtained by microtiter plate assays. Detection limits were in the range of 0.018-0.35 micromol/L in the flow-injection mode, and 0.075-0.75 micromol/L in the LC mode. These values are well below the typical compound concentrations (1-10 micromol/L) used in high-throughput screening. Together with an interday precision of 12.6%, these results demonstrate the applicability of the system for bioactivity screening of complex mixtures, generating both chemical and biological information on bioactive compounds in a single run.

Animals↗

Liquid chromatography with triple-quadrupole and quadrupole-time-of-flight mass spectrometry for the determination of micro-constituents - a comparison.

The potential of liquid chromatography with triple-quadrupole mass spectrometry (LC-QqQ MS) was compared to that of quadrupole time-of-flight mass spectrometry (LC-Q-ToF MS) for the determination of microconstituents. Three applications were studied: (1) the ng/l quantification of five human drugs in surface water and waste-water effluents; (2) the quantification and confirmation of three corticosteroids in bovine urine at concentrations of 1-100 microg/l, and; (3) the confirmation of nicotine in rat plasma. In all cases, the criteria of the EU Commission Decision 2002/657/EC were followed (for confirmation analysis two MS/MS ions were monitored, and the ratio of their abundances were calculated and compared with those of standards). With both techniques fully satisfactory results were obtained in almost all instances. That is, unequivocal confirmation according to the most stringent EU criteria, those for "illegal compounds", was possible.One main advantage of LC-Q-ToF MS is that for identification and confirmation purposes, full MS/MS spectra are available after a single injection: no second injection, as required with QqQ MS, is needed. As well as the increased efficiency, the enhanced selectivity due to the impressive mass selectivity of LC-Q-ToF MS must be emphasized, which allows accurate masses of fragment ions to be calculated. Method characteristics such as linear dynamic range and repeatability were found to be essentially the same for both techniques, but LC-QqQ MS has the advantage that its detection limits are somewhat lower.

Animals↗

Development of a simplified method for the simultaneous determination of retinol, alpha-tocopherol, and beta-carotene in serum by liquid chromatography-tandem mass spectrometry with atmospheric pressure chemical ionization.

A new and simple method for the determination of fat-soluble vitamins (retinol, alpha-tocopherol, and beta-carotene) in human serum was developed and validated by using liquid chromatography-tandem mass spectrometry with atmospheric pressure chemical ionization (LC-APCI-MS-MS). Different solvent mixtures were tested to obtain deproteinization and extraction of the analytes from the matrix. As a result, a volume of 240 microL of a 1:1 (v/v) ethanol/ethyl acetate mixture added to 60 microL of serum was found to be suitable for both protein precipitation and antioxidants solubilization, giving the best recovery for all three analytes. Deproteinized samples (20 microL) were injected after dilution, without the need for concentration or evaporation to dryness and reconstruction of the sample. Vitamins were separated on a C-8 column using a 95:5 (v/v) methanol/dichloromethane mixture and ionized in the positive-ion mode; detection was performed in the selected-reaction monitoring mode. Linearity of the LC-APCI-MS-MS method was established over 5 orders of magnitude for retinol and alpha-tocopherol, whereas in the case of beta-carotene it was limited to 4 orders. Lower limits of quantitation were 1.7, 2.3, and 4.1 nM for retinol, alpha-tocopherol, and beta-carotene, respectively. Serum concentrations of retinol, alpha-tocopherol, and alpha+beta-carotene determined in a group of healthy volunteers were 2.48, 38.07, and 0.50 microM, respectively, in samples collected in winter ( n=122) and 2.69, 45.88, and 0.90 microM during summer ( n=66).

Adult↗

Determination of patterns of biologically relevant aldehydes in exhaled breath condensate of healthy subjects by liquid chromatography/atmospheric chemical ionization tandem mass spectrometry.

A method for the simultaneous determination of several classes of aldehydes in exhaled breath condensate (EBC) was developed using liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS). EBC is a biological matrix obtained by a relatively new, simple and noninvasive technique and provides an indirect assessment of pulmonary status. The measurement of aldehydes in EBC represents a biomarker of the effect of oxidative stress caused by smoke, disease, or strong oxidants like ozone. Malondialdehyde (MDA), acrolein, alpha,beta-unsaturated hydroxylated aldehydes [namely 4-hydroxyhexenal (4-HHE) and 4-hydroxynonenal (4-HNE)], and saturated aldehydes (n-hexanal, n-heptanal and n-nonanal) were measured in EBC after derivatization with 2,4-dinitrophenylhydrazine (DNPH). Atmospheric pressure chemical ionization of the analytes was obtained in positive-ion mode for MDA, and in negative-ion mode for acrolein, 4-HHE, 4-HNE, and saturated aldehydes. DNPH derivatives were separated on a C18 column using variable proportions of 20 mM aqueous acetic acid and methanol. Linearity was established over 4-5 orders of magnitude and limits of detection were in the 0.3-1.0 nM range. Intra-day and inter-day precision were in the 1.3-9.9% range for all the compounds. MDA, acrolein and n-alkanals were detectable in all EBC samples, whereas the highly reactive 4-HHE and 4-HNE were found in only a few samples. Statistically significant higher concentrations of MDA, acrolein and n-hexanal were found in EBC from smokers.

Air Pressure↗

Developing strategies for isolation of minor impurities with mass spectrometry-directed fractionation.

Efficient and automated purification of new chemical entities/potential drug substances and isolation of minor impurities are important aspects of early drug discovery and development strategies, especially when combinatorial synthesis is applied. LC-MS controlled preparative LC and automated fraction collection have been developed for this purpose. The success of such an approach is greatly determined by the quality of the software controlling the application, the coordination between software and hardware, and the reliability of the hardware. The performance of a commercially-available LC-MS controlled autopurification system was evaluated by fractionating four impurities of buspirone as a model compound, eluting closely to the major component under both acidic and basic mobile-phase conditions. A purification strategy for these four components is proposed.

Buspirone↗

Liquid chromatography/electrospray tandem mass spectrometry characterization of styrene metabolism in man and in rat.

Liquid chromatography with electrospray tandem mass spectrometry was used to characterize the metabolism of styrene in man and in rat. To improve identification and characterization of minor styrene metabolites, rats were co-exposed to styrene and styrene-d(8). In addition to the main styrene metabolites, mandelic acid and phenylglyoxylic acid, and specific mercapturic acids, phenylhydroxyethylmercapturic acids (PHEMAs), other minor metabolites, including phenylglycine, N-acetyl-S-(phenacyl)cysteine, 4-vinylphenol and styreneglycol conjugates (glucuronides and sulfates) were identified and determined both in human and rat urine. Phenylglycine and N-acetyl-S-(phenacyl)cysteine have been hypothesized to occur, but never detected in human or rat urine after styrene exposure. 4-Vinylphenol and styrene glycol had already been recognized as styrene metabolites, but never determined as intact glucuronide and sulfate conjugates. Failure to identify 1- and 2-phenylethanol conjugates suggests that phenylethanol might be an intermediate metabolite, but it is not a conjugated catabolite. A method for the simultaneous determination of mandelic acid, phenylglyoxylic acid, phenyglycine and the four PHEMA diastereoisomers has been developed and validated. For those glucuronide and sulfate conjugates whose standards are not commercially available, a method for semiquantitative analysis, based on the use of structurally similar compounds as standards, has been developed. This approach was found to be valid for the determination of 4-vinylphenol glucuronide and 4-vinylphenol sulfate.

Acetylcysteine↗