Search PubMed⌕ Search

Biomedical subjects

Weiyan Nie

Publications and source records attributed to Weiyan Nie.

2 recordsLinked to original sources

Multiplex measurement of seven tumor markers using an electrochemical protein chip.

An electrochemical immunosensor for performing multianalyte measurements of tumor markers is described. The sensor consisted of an array of immunosensing electrodes fabricated on a glass substrate. Each electrode contained a different immobilized antigen and was capable of measuring a specific tumor marker using electrochemical enzyme-based competitive immunoassay. Using this arrangement, multiple analytes could be measured simultaneously by performing the technical operations for a single assay. The biosensor was used to measure the concentrations of seven important tumor markers: AFP, ferritin, CEA, hCG-beta, CA 15-3, CA 125, and CA 19-9. The sensor had excellent precision and accuracy and was comparable in performance to single-analyte ELISAs (1.9-8.1% interassay CV; <2 ng/mL (or units/mL) detection limit for most analytes). Multianalyte assays provide significant advantages over single-analyte tests in terms of cost per test, labor, test throughput, and convenience. We anticipate that chip-based sensors, as described herein, will be suitable for the mass production of economical, miniaturized lab-on-a-chip devices that will have applications in a wide range of clinical, environmental, and biodefense applications.

Antigens, Neoplasm↗

Electrochemical multianalyte immunoassays using an array-based sensor.

A novel amperometric biosensor for performing simultaneous electrochemical multianalyte immunoassays is described. The sensor consisted of eight iridium oxide sensing electrodes (0.78 mm(2) each), an iridium counter electrode, and a Ag/AgCl reference electrode patterned on a glass substrate. Four different capture antibodies were immobilized on the sensing electrodes via adsorption. Quantification of proteins was achieved using an ELISA in which the electrochemical oxidation of enzyme-generated hydroquinone was measured. The spatial separation of the electrodes enabled simultaneous electrochemical immunoassays for multiple proteins to be conducted in a single assay without amperometric cross-talk between the electrodes. The simultaneous detection of goat IgG, mouse IgG, human IgG, and chicken IgY was demonstrated. The detection limit was 3 ng/mL for all analytes. The sensor had excellent precision (1.9-8.2% interassay CV) and was comparable in performance to commercial single-analyte ELISAs. We anticipate that chip-based sensors, as described herein, will be suitable for the mass production of economical, miniaturized, multianalyte assay devices.

Animals↗