Acute and subacute intracerebral hemorrhages: comparison of MR imaging at 1.5 and 3.0 T--initial experience.

PURPOSE: To assess and describe the appearance of intracerebral hemorrhage (ICH) at 3.0-T magnetic resonance (MR) imaging as compared with the appearance of this lesion type at 1.5-T MR imaging. MATERIALS AND METHODS: Sixteen patients with 21 parenchymal ICHs were examined. ICHs were classified as hyperacute, acute, early subacute, late subacute, or chronic. Patients underwent 1.5- and 3.0-T MR imaging with T2-weighted fast spin-echo, fluid-attenuated inversion-recovery (FLAIR), and T1-weighted spin-echo (1.5-T) and gradient-echo (3.0-T) sequences within 4 hours of each other. The central (ie, core) and peripheral (ie, body) parts of the ICHs were analyzed quantitatively by using contrast-to-noise ratio (CNR) calculations derived from signal intensity (SI) measurements; these values were statistically evaluated by using the Mann-Whitney U test. Two readers qualitatively determined SIs of the cores and bodies of the ICHs, degrees of apparent susceptibility artifacts, and lesion ages. The chi(2) test was used to determine statistically significant differences. RESULTS: With the exception of the bodies of late subacute ICHs at 3.0-T T2-weighted imaging, which had increased positive CNRs and SI scores (P </=.05), all parts of the ICHs at all stages showed increased negative CNRs and SI scores at 3.0-T FLAIR and T2-weighted imaging, as compared with these values at 1.5 T (P </=.05). No significant CNR or SI score differences at any ICH stage were observed between 1.5-T spin-echo and 3.0-T gradient-echo T1-weighted imaging (P >.05). With the exception of minor susceptibility artifacts seen in acute and early subacute ICHs at 3.0-T T1-weighted gradient-echo imaging, no susceptibility artifacts were noticed. The ages of most lesions were identified correctly without significant differences between the two field strengths (P >.05), with the exception of the ages of acute ICHs, which were occasionally misinterpreted as early subacute lesions at 3.0 T. CONCLUSION: At 3.0 T, all parts of acute and early subacute ICHs had significantly increased hypointensity on FLAIR and T2-weighted MR images as compared with the SIs of these lesions at 1.5 T. However, 1.5- and 3.0-T MR images were equivalent in the determination of acute to late subacute ICHs.

Acute Disease↗

Low-voltage digital selenium radiography: detection of simulated interstitial lung disease, nodules, and catheters--a phantom study.

PURPOSE: To compare three tube voltages in digital selenium radiography for the detection of simulated interstitial lung disease, nodules, and catheters. MATERIALS AND METHODS: Simulated catheters, nodules, and ground-glass, linear, miliary, and reticular patterns were superimposed over an anthropomorphic chest phantom. Digital selenium radiography was performed with different tube voltages (70, 90, and 150 kVp). Hard-copy images were generated. Detection performance of five radiologists was compared by using receiver operating characteristic (ROC) analysis involving 54,000 observations. RESULTS: The detection of ground-glass, linear, miliary, and reticular patterns over lucent lung and of nodules equal to, smaller than, and larger than 10 mm increased when 70 kVp and/or 90 kVp was used. However, only the reticular pattern was significantly better detected at lower peak voltage (P <.05). Simulated catheters and nodules over the mediastinum showed smaller areas under the ROC curve at lower peak voltage. These results were not statistically significant (P >.05). CONCLUSION: The diagnostic performance of digital selenium radiography at lower peak voltage is at least as good as that at higher peak voltage for interstitial lung disease over lucent lung. Performance is equivalent for nodules and catheters over obscured chest regions at lower peak voltages compared with that at 150 kVp. Our results implicate that the use of high-voltage technique in digital selenium radiography should be reassessed.

Catheterization↗

Proton magnetic resonance spectroscopy in anorexia nervosa: correlations with cognition.

The aim of this study was to investigate the relationship between cognitive impairment and cerebral metabolites in patients with anorexia nervosa (AN). N-acetylaspartate (NAA), creatine/phosphocreatine (Cr), choline-containing compounds, glutamate/glutamine (Glx) and myoinositol were measured by proton magnetic resonance spectroscopy (H-MRS) of the left prefrontal cortex. Compared with healthy controls, AN patients displayed a significantly poorer performance in verbal learning and in attentional and executive tasks. Performance in the divided attention task was correlated with NAA and Cr in the dorsolateral prefrontal cortex, while executive functioning and depressive symptomatology were associated with Glx levels in the anterior cingulate. Our results provide evidence for cognitive impairment in AN patients which is associated with cerebral metabolism in the prefrontal cortex.

Adult↗

Screening for early lung cancer with low-dose spiral computed tomography: results of annual follow-up examinations in asymptomatic smokers.

The aim of this study was analysis of incidence results in a prospective one-arm feasibility study of lung cancer screening with low-radiation-dose spiral computed tomography in heavy smokers. Eight hundred seventeen smokers (> or =40 years, > or =20 pack years of smoking history) underwent baseline low-dose CT. Biopsy was recommended in nodules >10 mm with CT morphology suggesting malignancy. In all other lesions follow-up with low-dose CT was recommended. Annual repeat CT was offered to all study participants. Six hundred sixty-eight (81.8%) of the 817 subjects underwent annual repeat CT with a total of 1735 follow-up years. Follow-up of non-calcified nodules present at baseline CT demonstrated growth in 11 of 792 subjects. Biopsy was performed in 8 of 11 growing nodules 7 of which represented lung cancer. Of 174 new nodules, 3 represented lung cancer. The 10 screen-detected lung cancers were all non-small cell cancer (6 stage IA, 1 stage IB, 1 stage IIIA, 2 stage IV). Five symptom-diagnosed cancers (2 small cell lung cancer: 1 limited disease, 1 extensive disease, 3 central/endobronchial non-small cell lung cancer, 2 stage IIIA, 1 stage IIIB) were diagnosed because of symptoms in the 12-month interval between two annual CT scans. Incidence of lung cancer was lower than prevalence, screen-detected cancers were smaller, and stage I was found in 70% (7 of 10) of screen-detected tumors. Only 27% (4 of 15) of invasive procedures was performed for benign lesions; however, 33% (5 of 15) of all cancers diagnosed in the population were symptom-diagnosed cancers (3 central NSCLC, all stage III, 2 SCLC) demonstrating the limitations of CT screening.

Algorithms↗

First-pass and equilibrium-MRA of the aortoiliac region with a superparamagnetic iron oxide blood pool MR contrast agent (SH U 555 C): results of a human pilot study.

The purpose of this study was to study different doses for first-pass and equilibrium phase MRA of aortoiliac vessels with a superparamagnetic iron oxide (SPIO) intravascular MR contrast agent (SH U 555 C) after single i.v. bolus injection. Sixteen healthy volunteers were prospectively enrolled into this single-blind, placebo-controlled clinical trial. SHU 555 C was injected as an i.v. bolus at stepwise increased dose levels of 5, 10, 20 and 40 micromol Fe/kg bodyweight (b.w.) corresponding to injection volumes of 0.01, 0.02, 0.04 and 0.08 ml/kg b.w. Serial high-resolution three-dimensional MRA of the aortoiliac vessels was acquired during first-pass and equilibrium, at 6 min intervals up to 42 min after contrast application using a breath-hold three-dimensional FLASH sequence on a 1.5 T scanner. Intravascular enhancement was calculated within the abdominal aorta and the inferior vena cava and a statistical analysis for significant differences in vessel enhancement was performed during the bolus and equilibrium phases. The visibility of vessels was ranked and effects of potential artifacts on image quality were graded for each time point and dose group. SH U 555 C showed a dose-dependent intravascular enhancement during the observation period (42 min). The highest dose of 40 micromol Fe/kg b.w. revealed the highest image quality during first-pass and equilibrium phases. The intravascular enhancement in the aorta increased dose-dependently from 5 to 40 micromol kg b.w. during first-pass and equilibrium phases (p<0.05). Intravascular signal inhomogeneities were observed at lower doses and decreased with increasing doses. First-pass MRA was diagnostic at doses of 10, 20 and 40 micromol Fe/kg b.w. For equilibrium MRA, a dose of 40 micromol Fe/kg b.w. was considered to be diagnostic. SH U 555 C proved to be a contrast agent with a high T1-effect suitable for both first-pass MRA comparable to gadolinium-enhanced MRA and high resolution equilibrium MRA up to 42 min post-injection (p.i.).

Adult↗

Diagnostic performance of a flat-panel detector at low tube voltage in chest radiography: a phantom study.

RATIONALE AND OBJECTIVES: To evaluate a large area, cesium iodide amorphous silicon flat-panel detector (CsI/a-Si) at 3 tube voltages to detect simulated interstitial lung disease, nodules, and catheters. METHODS: Simulated interstitial lung disease, nodules, and catheters were superimposed over a chest phantom. Images were generated at 125 kVp, 90 kVp, and 70 kVp at the same surface dose and reduced effective dose equivalent for 90 kVp and 70 kVp and printed on hard copies. Fifty-four thousand observations were analyzed by receiver operating characteristic (ROC). RESULTS: Detectability of linear, miliary, reticular pattern, and nodules over lucent lung as well as of catheters and nodules over obscured chest areas increased at 90 and/or 70 kVp with higher Az values; however, only it was statistically significant for reticular pattern at 70 kVp and nodules at 90 kVp compared with 125 kVp (P < 0.05). The detection of ground-glass pattern was worse at lower kVp (P > 0.05). CONCLUSION: For most simulated patterns, differences in diagnostic performance at 70 kVp/90 kVp and 125 kVp were not significant, except for reticular pattern and nodules over lucent lung.

Cesium↗

3.0 Tesla magnetic resonance angiography of endovascular aortic stent grafts: phantom measurements in comparison with 1.5 Tesla.

RATIONALE AND OBJECTIVES: This study evaluated different stent grafts by 3 T magnetic resonance angiography (MRA) with respect to lumen visibility, susceptibility-induced signal loss, and type of stent artifacts compared with 1.5 T MRA in a phantom model. METHODS: Six different stent-grafts (tube: n = 3, bifurcated: n = 3) were evaluated by 3 T and 1.5 T MRA using a tube phantom. MRA was performed using T1-weighted sequences at both systems with comparable parameters (3T: TR 5.4/TE 2.0/FA 30 degrees, 1.5 T: TR 6.2/TE 2.2/FA 30 degrees). A blind study of the image quality, including artifacts, was performed by 3 radiologists. Furthermore, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values were calculated. Statistical analysis was performed with Student's t test (P < 0.05). RESULTS: One Elgiloy stent graft showed almost a complete intraluminal signal loss at 1.5 and 3 T. All other models could be evaluated by both systems by MRA, resulting in a favorable lumen visibility (score: 1) for prostheses made of nitinol. Scores for overall image quality and artifacts were the same for both MR systems. SNR and CNR values of the stented part of the vessel phantom increased from 320 +/- 33 to 618 +/- 40 and from 306 +/- 34 to 596 +/- 40 at 3 T when compared with 1.5 T, resulting in a significant signal gain of 93% at the higher field strength. CONCLUSIONS: 3 Tesla MRA of aortic stent grafts in a phantom model demonstrates an increase in SNR and CNR when compared with 1.5 T. However, the magnitude of imaging artifacts as well as coherent intraluminal signal loss within the stent does not increase equally in both MR systems.

Aorta↗

Endovascular management of tandem extracranial internal carotid artery aneurysms with a covered stent.

PURPOSE: To illustrate the endovascular technique for treating tandem arterial aneurysms in the distal carotid artery. CASE REPORT: A 49-year-old woman presented with progressive swelling of the neck caused by a pulsatile tumor. Angiography demonstrated 2 aneurysms of the extracranial internal carotid artery near the skull base, so surgery was not a therapeutic option. Both aneurysms were successfully excluded with deployment of a single Wallgraft across both lesions; no complications were encountered. At 2-year follow-up, the patient is doing well, without any sign of aneurysm reperfusion. CONCLUSIONS: The presented case demonstrates that stenting of tandem aneurysms may be performed even in the carotid artery. Nevertheless, this treatment should be considered as a therapeutic option only in selected cases.

Aneurysm↗

Coronary MR angiography: comparison of quantitative and qualitative data from four techniques.

OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.

Aged↗

Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

PURPOSE: To determine left ventricular (LV) volumetric and functional parameters from retrospectively electrocardiographically gated multi-detector row computed tomography (CT) by using semiautomated analysis software and to correlate results with those of magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 30 patients (mean age, 59.2 years +/- 7.1 [SD]) known to have or suspected of having coronary artery disease, four-channel multi-detector row CT was performed with standard technique, and diastolic and systolic image reconstructions were generated. With commercially available analysis software capable of semiautomated contour detection, end diastolic and end systolic LV volumes were determined from short-axis secondary CT reformations. Steady-state free-precession cine MR images were acquired in short-axis orientation within 48 hours and analyzed by using dedicated software. Bland-Altman analysis was performed to calculate limits of agreement and systematic errors between CT and MR imaging. RESULTS: Mean end diastolic (138.8 mL +/- 31.9) and end systolic (53.9 mL +/- 21.2) LV volumes as determined with CT correlated well with MR imaging measurements (142.0 mL +/- 32.5 [r = 0.93] and 54.9 mL +/- 22.8 [r = 0.94], respectively [P <.001]). LV ejection fraction (61.6% +/- 10.6 for CT vs 62.3% +/- 10.1 for MR imaging; r = 0.89) and stroke volume (84.6 mL +/- 20.9 for CT vs 86.9 mL +/- 21.5 for MR imaging; r = 0.88) also showed good correlation (P <.001). Bland-Altman analysis showed acceptable limits of agreement (+/-9.8% for ejection fraction) without systematic errors. CONCLUSION: In selected patients, semiautomated analysis software enables LV volumetric and functional analysis based on multi-detector row CT data sets, the results of which correlate well with MR imaging findings.

Aged↗

Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility.

The aim of this study was to assess the in vivo measurement precision of a software tool for volumetric analysis of pulmonary nodules from two consecutive low-dose multi-row detector CT scans. A total of 151 pulmonary nodules (diameter 2.2-20.5 mm, mean diameter 7.4+/-4.5 mm) in ten subjects with pulmonary metastases were examined with low-dose four-detector-row CT (120 kVp, 20 mAs (effective), collimation 4x1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm; Somatom VolumeZoom, Siemens). Two consecutive low-dose scans covering the whole lung were performed within 10 min. Nodule volume was determined for all pulmonary nodules visually detected in both scans using the volumetry tool included in the Siemens LungCare software. The 95% limits of agreement between nodule volume measurements on different scans were calculated using the Bland and Altman method for assessing measurement agreement. Intra- and interobserver agreement of volume measurement were determined using repetitive measurements of 50 randomly selected nodules at the same scan by the same and different observers. Taking into account all 151 nodules, 95% limits of agreement were -20.4 to 21.9% (standard error 1.5%); they were -19.3 to 20.4% (standard error 1.7%) for 105 nodules <10 mm. Limits of agreement were -3.9 to 5.7% for intraobserver and -5.5 to 6.6% for interobserver agreement. Precision of in vivo volumetric analysis of nodules with an automatic volumetry software tool was sufficiently high to allow for detection of clinically relevant growth in small pulmonary nodules.

Adult↗

Lumbar spine radiography: digital flat-panel detector versus screen-film and storage-phosphor systems in monkeys as a pediatric model.

PURPOSE: To assess image quality and exposure dose requirements of a flat-panel detector system versus screen-film and storage-phosphor systems for radiographic depiction of the lumbar spine in Cynomolgus monkeys as a pediatric model. MATERIALS AND METHODS: Twenty Cynomolgus monkeys underwent anteroposterior radiography of the lumbar spine. The size and weight of these monkeys are comparable to those of infants 3-4 months of age. Images were acquired with speed class 400 screen-film, flat-panel, and storage-phosphor systems with identical exposure dose. All other conditions were matched exactly. Additional images were acquired with the flat-panel and storage-phosphor systems at exposure doses equivalent to speed classes 800 and 1600. All images were obtained at 66 kVp without antiscatter grid. Images were assessed independently by three radiologists for visibility of 60 anatomic structures by using a five-point confidence scale. Scores were calculated for the seven combinations of imaging mode and exposure dose and were compared by using the Friedman test. RESULTS: Scores were 1.70 (speed class 400), 1.97 (speed class 800), and 2.27 (speed class 1600) for the flat-panel system; 2.50 (speed class 400) for the screen-film system; and 2.58 (speed class 400), 2.77 (speed class 800), and 3.13 (speed class 1600) for the storage-phosphor system. Scores for the flat-panel system at speed classes 400 and 800 were significantly lower (indicating better visibility) than those of the screen-film and storage-phosphor systems (P <.05). CONCLUSION: The flat-panel system is superior to screen-film and storage-phosphor systems in lumbar spine radiography in monkeys. With the flat-panel system, exposure dose can be reduced by 75% without loss in image quality.

Animals↗

Acute mania is accompanied by elevated glutamate/glutamine levels within the left dorsolateral prefrontal cortex.

RATIONALE: The dorsolateral prefrontal cortex (DLPFC) participates in the pathophysiology of mania. In particular, left-sided structural and metabolic abnormalities have been described. OBJECTIVES: Clinical symptoms may be due to hyperactivity of cortical glutamatergic neurons, resulting in increased excitatory neurotransmitter flux and thus enhanced Glx levels. METHODS: Glutamate/glutamine (Glx) levels were assessed by proton magnetic resonance spectroscopy ((1)H-MRS) in eight acute manic patients compared with age- and gender-matched controls. RESULTS: Manic patients had significantly elevated Glx levels ( t-test; t=-3.1, P=0.008) within the left DLPFC. CONCLUSIONS: Our results indicate that the prefrontal cortical glutamatergic system is involved in the pathophysiology of acute mania. This may have implications for the treatment of mania.

Acute Disease↗

Effective electroconvulsive therapy reverses glutamate/glutamine deficit in the left anterior cingulum of unipolar depressed patients.

Cortical glutamate/glutamine (Glx) metabolism seems to be affected by a major depressive disorder. Recently, a Glx deficit was detected by proton magnetic resonance spectroscopy (1H-MRS) in the bilateral anterior cingulum of depressives. The aim of this study was to assess the effect of successful electroconvulsive therapy (ECT) on Glx levels in the anterior cingulum. The left anterior cingulum of 17 severely depressed unipolar patients was measured by 1H STEAM spectroscopy before and after ECT, and the results were compared with those for 17 age- and gender-matched controls. We observed significantly reduced Glx levels in the patients' left cingulum compared to healthy controls. In ECT responders, in contrast to non-responders, Glx levels normalized (P=0.04) and then did not differ statistically from controls. Severe depression seems to be associated with a Glx deficit and increasing Glx may be an important mechanism of ECT action.

Depressive Disorder↗

Detection of subtle undisplaced rib fractures in a porcine model: radiation dose requirement--digital flat-panel versus screen-film and storage-phosphor systems.

PURPOSE: To compare a large-area direct read-out flat-panel detector radiography system with screen-film and storage-phosphor systems with regard to detection of subtle undisplaced rib fractures and to assess the diagnostic performance of the flat-panel system with decreasing exposure level. MATERIALS AND METHODS: Subtle fractures were created artificially in 100 of 200 porcine rib specimens. Specimens were enclosed in containers of water to generate absorption and scatter radiation conditions similar to those of a human chest wall. Imaging was performed with flat-panel, screen-film, and storage-phosphor systems with conditions that were exactly matched. Different exposure levels equivalent to speed classes (S) of 400, 800, 1,600, and 6,400 were used. All images were independently assessed for the presence of fracture by three radiologists with a five-level confidence scale. Receiver operating characteristic (ROC) analysis was performed for a total of 4,200 observations (600 for each imaging system and exposure level). Diagnostic performance was estimated with area under the ROC curve (Az). Significance of differences in diagnostic performance was tested with analysis of variance. RESULTS: ROC analysis yielded mean Az values for the flat-panel system of 0.879 (S = 400), 0.833 (S = 800), 0.765 (S = 1,600), and 0.576 (S = 6,400). Az values were 0.834 (S = 400) for the screen-film system and 0.789 (S = 400) and 0.729 (S = 800) for the storage-phosphor system. Analysis of variance revealed significant differences in diagnostic performance between various combinations of imaging system and exposure levels (P <.05). CONCLUSION: The flat-panel system is superior to the screen-film and storage-phosphor systems for detection of subtle undisplaced rib fractures at clinical exposure settings (eg, S = 400). With the flat-panel system, radiation dose can be reduced by 50% to achieve diagnostic performance comparable to that of a speed class 400 screen-film system.

Animals↗

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm ( n=4), intramural bleeding ( n=2) and type-B aortic dissection ( n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as alternative non-invasive imaging for follow-up of nitinol stent grafts. Arterial-phase leak assessment can be less evident in CE MRA compared with MS CTA studies; therefore, the use of late-phase imaging seems to be necessary. The diagnostic gap of stent-graft fracture evaluation using MRA may be filled with plain radiographs.

Aged↗

Hazardous situation in the MR bore: induction in ECG leads causes fire.

There is a potential hazard during examinations of patients with attached or implanted long conductors, e.g. ECG leads: an MR exam of the lumbar spine of a patient was performed in a 1.5-T scanner under ECG monitoring using equipment marked as MR compatible. Standard cabling of 370-cm length was guided without loops from the electrodes through the caudal opening of the magnet bore. During a sagittal T1-weighted turbo-spin-echo scan suddenly a flame of approximately 3 cm arose from the patient's shirt, close to the position of the electrodes. The supervising anaesthesiologist extinguished the flames with his hands. A subsequent physical examination revealed second- to third-degree burns. The analysis of the incident revealed that high voltages can be induced in straight conductors without loops as ECG cables by coupling with the electric component of the HF field. Local heating or sparking can cause an open flame at the position of the electrodes. This danger exists even with ECG equipment that is specifically marked as MR compatible.

Electrocardiography↗