Search PubMed⌕ Search

Biomedical subjects

Wai Lee T Wong

Publications and source records attributed to Wai Lee T Wong.

4 recordsLinked to original sources

The pharmacokinetics of an albumin-binding Fab (AB.Fab) can be modulated as a function of affinity for albumin.

An AB.Fab (albumin-binding Fab) consists of a Fab and a phage-derived albumin-binding peptide. This molecule is capable of binding both antigen and albumin simultaneously. Using a Fab derived from Herceptin we generated a panel of AB.Fab variants with wide-ranging affinities for albumin. An assay that measured AB.Fab binding to albumin in solution was developed to most accurately reflect the binding affinity for albumin in vivo. Affinity varied depending upon the species of albumin tested. For rat and rabbit albumin, affinities ranged from 0.04 to 2.5 microM. Reduced affinity for albumin correlated with a reduced half-life and higher clearance rates in both species; the beta half-life ranged 6-fold while clearance ranged over 50-fold in rats and 20-fold in rabbits. To estimate the pharmacokinetic properties of an AB.Fab in humans, AB.Fab variants with similar affinities for rat and rabbit albumin were selected. Using their pharmacokinetic parameters and the principles of allometric scaling for albumin, we estimate an approximate beta half-life for an AB.Fab with 0.5 microM affinity for albumin of up to 4 days in humans with a clearance of 76 ml/h. These variants demonstrate the ability to modulate the clearance of a Fab fragment in vivo and help to establish guidelines for pharmacokinetic engineering of molecules through albumin binding.

Albumins↗

Substrate capacity considerations in developing kinase assays.

In developing a screening assay for a serine/threonine kinase, we evaluated various formats of an in-plate enzyme-linked immunosorbent assay (ELISA), as well as solution-phase kinase assays using either ELISA or AlphaScreen detection. Substrate was available both as a biotinylated 15-residue peptide and as a 25-residue peptide containing the same sequence expressed as a glutathione S-transferase fusion protein. When increasing concentrations of either of these substrates were coated directly onto ELISA plates, the rates of the kinase reactions progressively increased. In contrast, when the biotin-peptide was captured onto NeutrAvidin-coated plates, the finite peptide binding capacity of the plates limited the amount of substrate that could be incorporated into the assay system and thereby limited the rate of the reaction at a given kinase concentration. Solution-phase kinase reactions can tolerate high substrate concentrations; however, analysis of kinase reaction samples containing biotin-peptide concentrations higher than the binding capacity of NeutrAvidin-coated plates resulted in an inability to detect differences between reactions run at different substrate concentrations. For AlphaScreen detection following solution-phase kinase reactions, limitations in the binding capacity of the donor and acceptor beads caused loss of signal for substrate concentrations above the maximum binding capacity. Overall, the solution-phase assays required significantly more kinase than the in-plate assays (1-4 microg/ml versus <100 ng/ml, respectively). These studies demonstrate that the amount of substrate that can be incorporated into an assay system substantially affects the rate of the kinase reaction and therefore the amount of kinase required for the assay.

Enzyme-Linked Immunosorbent Assay↗

Nucleic acid capture assay, a new method for direct quantitation of nucleic acids.

Technologies allowing direct detection of specific RNA/DNA sequences occasionally serve as an alternative to amplification methods for gene expression studies. In these direct methods the hybridization of probes takes place in complex mixtures, thus specificity and sensitivity still limit the use of current technologies. To address these challenges, we developed a new technique called the nucleic acid capture assay, involving a direct multi-capture system. This approach combines a 3'-ethylene glycol scaffolding with the incorporation of 2'-methoxy deoxyribonucleotides in the capture sequences. In our design, all nucleotides other than those complementary to the target mRNA have been replaced by an inert linker, resulting in significant reductions in non-specific binding. We also provide a versatile method to detect the presence of captured targets by using specific labeled probes with alkaline phosphatase-conjugated anti-label antibodies. This direct, flexible and reliable technique for gene expression analysis is well suited for high-throughput screening and has potential for DNA microarray applications.

Chemistry Techniques, Analytical↗

Development of a frozen cell array as a high-throughput approach for cell-based analysis.

Recent advances in molecular biology, human genetics, and functional genomics tremendously increase the number of molecular targets available for potential therapeutic and diagnostic use. To complement DNA array data, cost-efficient high-throughput technologies providing reliable information at the protein level need to be developed. Here we describe the generation of a frozen cell array that required the use of single cell suspensions and could serve various applications such as the analysis of specific antibody or ligand binding to a large panel of different cell types. As an example, binding of an anti-human epithelial cell adhesion molecule monoclonal antibody to 24 different cell lines has been analyzed using the cell array and compared to the data generated by fluorescence-activated cell sorting. The reliability and flexibility of our frozen cell array technology is compatible with the needs of high-throughput screening for drug discovery and target validation.

Antibodies↗