Search PubMed⌕ Search

Biomedical subjects

W Wijns

Publications and source records attributed to W Wijns.

142 records · Page 8Linked to original sources

Alternative diagnostic strategies for coronary artery disease in women: demonstration of the usefulness and efficiency of probability analysis.

Alternative strategies using conditional probability analysis for the diagnosis of coronary artery disease (CAD) were examined in 93 infarct-free women presenting with chest pain. Another group of 42 consecutive female patients was prospectively analyzed. For this latter group, the physician had access to the pretest and posttest probability of CAD before coronary angiography. These 135 women all underwent stress electrocardiographic, thallium scintigraphic, and coronary angiographic examination. The pretest and posttest probabilities of coronary disease were derived from a computerized Bayesian algorithm. Probability estimates were calculated by the four following hypothetical strategies: SO, in which history, including risk factors, was considered; S1, in which history and stress electrocardiographic results were considered; S2, in which history and stress electrocardiographic and stress thallium scintigraphic results were considered; and S3, in which history and stress electrocardiographic results were used, but in which stress scintigraphic results were considered only if the poststress probability of CAD was between 10% and 90%, i.e., if a sufficient level of diagnostic certainty could not be obtained with the electrocardiographic results alone. The strategies were compared with respect to accuracy with the coronary angiogram as the standard. For both groups of women, S2 and S3 were found to be the most accurate in predicting the presence or absence of coronary disease (p less than .05). However, it was found with use of S3 that more than one-third of the thallium scintigrams could have been avoided without loss of accuracy. It was also found that diagnostic catheterization performed to exclude CAD as a diagnosis could have been avoided in half of the patients without loss of accuracy.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Values and limitations of transstenotic pressure gradients measured during percutaneous coronary angioplasty.

The pressure gradient across coronary stenoses is measured routinely during angioplasty. Due to the finite size of the angioplasty catheter within the stenotic cross section, the remaining luminal area is further reduced and the transstenotic gradient may be overestimating the "true" pressure drop. This "true" pressure gradient can be approximated from the mean coronary blood flow and the stenosis geometry from theoretical models. Goal of this study was to assess the values and limitations of the in vivo measurements of the pressure gradient versus the calculated values. Therefore, flow in the great cardiac vein was measured in 13 patients before and/or after angioplasty of a proximal left anterior descending stenosis, not filled by collaterals. The Poiseuille and turbulent contributions to flow resistance were determined from stenosis geometry assessed by quantitative coronary angiography. A fourfold increase in the luminal area (from 0.7 mm2 pre- to 2.8 mm2 post angioplasty) was associated with a fourfold decrease in the in vivo measured transstenotic gradient (from 59 mm Hg pre- to 13 mm Hg post angioplasty). The occlusion area and the measured gradient were linearly correlated: gradient = 69-17 X occlusion area (r = 0.76). However, as expected, the transstenotic gradient systematically overestimated the theoretical gradient calculated from the laws of fluid dynamics. A nonlinear relation was found between the calculated gradient P and the occlusion area As: P = 15 X As-2 (r = 0.87).

Angina Pectoris↗

Effect of intracoronary thrombolytic therapy on global and regional left ventricular function. A three year experience with randomization.

The effect of myocardial reperfusion on regional left ventricular function has been quantitated by analysis of segmental wall motion in 185 patients enrolled in a randomized trial comparing thrombolysis with conventional treatment in patients with acute myocardial infarction. When analyzing the hemodynamic data on an "intention to treat" basis we found a significant preservation of left ventricular function after thrombolytic therapy when compared to conventional treatment. In addition, the wall motion analysis showed that a significant improvement of regional function in the "infarct zone" was observed in inferior infarction as well as in anterior infarction, although significant changes in regional function of the remote "non infarct zone" were observed at the acute as well as at the chronic stage. However, our follow-up data indicate that as yet it has not been resolved whether this method of treatment does indeed improve prognosis in patients with acute myocardial infarction. Accordingly, we maintain the view that such invasive treatment should not be generally applied until more follow-up data become available from larger randomized trials.

Aged↗

Validation of radionuclide cardiac output measurements during exercise.

A nongeometric radionuclide technique with correction for attenuation was used for the determination of cardiac output and stroke volume during exercise in nine normal subjects and in ten hypertensive patients. Simultaneous reference stroke volume (range 48-159 ml) and cardiac output (range 3.6-23.8 l/min) measurements were obtained by the Fick method. Data were collected at rest and during 60 degrees upright exercise, at two or three levels of increasing severity. Three statistical measurements were used for the comparison of both methods: correlation, precision, and accuracy. Radionuclide and Fick cardiac output measurements (n = 67, rest and exercise data) correlated well (r = 0.90). For stroke volume, the correlation was less (r = 0.64); however, the precision or random variability of both methods was similar for stroke volume (radionuclide: 8 ml or 9%; Fick: 16 ml or 16%). The accuracy or systematic error was defined as the mean difference between radionuclide and Fick measurements. The radionuclide method underestimated the Fick measurements. The systematic error was 18 +/- 18 ml for stroke volume and 2.4 +/- 2.4 l/m for cardiac output. A similar comparison of both methods was made on the absolute changes of stroke volume (r = 0.61; range -19 + 70 ml) and cardiac output (r = 0.82; range +1.6 + 16.4 l/m) between rest and exercise. The precision of the two methods was similar; the systematic error was 1.9 +/- 2.2 l/m for cardiac output and 6 +/- 17 ml for stroke volume. Thus, in these two groups of patients, although radionuclide and Fick cardiac output measurements at rest and during exercise correlated well, the radionuclide values were systematically and significantly lower.

Adult↗

Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements.

Cineangiograms of 138 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) were analyzed with a computer-based coronary angiography analysis system. The results before and after dilatation are presented. In a first study group (120 patients), the severity of the obstructive lesions derived from the automatically detected contours was evaluated in absolute terms and in percent-diameter reduction. In a second group of patients, 18 coronary lesions were selected for their extreme severity and symmetric aspect before angioplasty as assessed from multiple views. In the second group, the densitometric percent-area stenosis was used to assess the changes in cross-sectional area after PTCA and was compared with the circular percent-area stenosis computed from the diameter measurements. Before PTCA, a good agreement exists between the densitometric percent-area stenosis and the circular percent-area stenosis. After PTCA, important discrepancies between these 2 types of measurements are observed. It is suggested that these discrepancies in results after PTCA can be accounted for by asymmetric morphologic changes in luminal cross section, which cannot be assessed accurately from diameter measurements in a single-plane view.

Absorptiometry, Photon↗

The exercise response in idiopathic dilated cardiomyopathy.

In order to more clearly define the exercise response of idiopathic dilated cardiomyopathy (IDC), 20 patients in this study with strictly defined IDC were evaluated with radionuclide ventriculography and invasive hemodynamic monitoring. Severe cardiovascular impairment was present at rest, and peak supine exercise produced progressive left ventricular (LV) dilatation in both diastole and systole (mean +/- SEM from 172 +/- 14 to 212 +/- 22 ml/m2 at end-diastole and from 137 +/- 14 to 170 +/- 22 ml/m2 at end-systole; both p less than 0.03). There were marked increases in LV and right ventricular filling pressure (from 17 +/- 2 to 36 +/- 3 mmHg and from 7 +/- 2 to 15 +/- 2 mmHg, respectively; both p less than 0.0001) and increased pulmonary artery pressure. Mean LV ejection fraction did not change significantly with exercise (22 +/- 2 to 23 +/- 3%; p greater than 0.8), but individual patients demonstrated substantial variability. Cardiac output rose less than in normals and increases were brought about primarily by subnormal heart rate increases. High resting and exercise systemic and pulmonary vascular resistance were indicative of limited vasodilator reserve. Despite marked hemodynamic abnormalities, 10 of the 20 subjects had well preserved exercise capacity (greater than or equal to 12 min exercise duration). These patients as a group had significantly lower resting heart rate and higher exercise cardiac output and lower exercise systemic vascular resistance. However, they did not differ from the other patients with respect to resting LV function.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Prediction of mortality in hospital survivors of myocardial infarction. Comparison of predischarge exercise testing and radionuclide ventriculography at rest.

The relative merits of resting ejection fraction measured by radionuclide angiography and predischarge exercise stress testing were compared for predicting prognosis in hospital survivors of myocardial infarction. Two hundred and fourteen survivors of myocardial infarction out of 338 consecutive patients with acute myocardial infarction were studied over a 14 month period. Hospital mortality was 13% (45 of 338) whereas 19 additional patients out of 214 died in the subsequent year (9%). High, intermediate, and low risk groups could be identified by left ventricular ejection fraction measurement. Mortality was 33% for nine patients with an ejection fraction less than 20%, 19% for 58 patients with an ejection fraction between 20% and 39%, and 3% for 147 patients with an ejection fraction greater than 40%. Mortality was high (23%) in 47 patients who were unable to perform the stress test because of heart failure (19) or other limitations (28). The patients could be stratified further into intermediate and low risk groups according to the increase in systolic blood pressure during exercise: six deaths occurred in 46 patients with a blood pressure increase of less than 30 mm Hg and two deaths occurred in 121 patients with an increase greater than or equal to 30 mm Hg. Maximum workload, angina, ST changes, and ventricular arrhythmias were less predictive than blood pressure changes. It is concluded that the prognostic value of radionuclide angiography at rest and of symptom limited exercise testing is similar. The latter investigation should be the method of choice since it provides more specific information for patient management.

Aged↗

Left ventricular performance, regional blood flow, wall motion, and lactate metabolism during transluminal angioplasty.

The response of left ventricular function, coronary blood flow, and myocardial lactate metabolism during percutaneous transluminal coronary angioplasty (PTCA) was studied in a series of patients undergoing the procedure. From four to six balloon inflation procedures per patient were performed with an average duration per occlusion of 51 +/- 12 sec (mean +/- SD) and a total occlusion time of 252 +/- 140 sec. Analysis of left ventricular hemodynamics in 19 patients showed that the relaxation parameters, peak negative rate of change in pressure, and early time constants of relaxation, responded earliest to short-term coronary occlusion (peak effect at 17 +/- 7 sec) while other parameters, such as peak pressure, left ventricular end-diastolic pressure, and peak positive rate of change in pressure, responded more gradually, suggesting a progressive depression of myocardial mechanics throughout the procedure. Left ventricular angiograms, available for 14 patients, indicated an early onset of asynchronous relaxation concurrent with the early response in peak negative dP/dt and the time constant of early relaxation. All hemodynamic functions fully recovered within minutes after the end of PTCA. Mean blood flow in the great cardiac vein and proximal coronary sinus and the hyperemic response were measured in 20 patients. Before PTCA mean flow in the great cardiac vein was 69 +/- 17 ml/min and in the coronary sinus it was 129 +/- 34 ml/min. Reactive hyperemia (great cardiac vein) was 55% after the first PTCA and 91% after the third. A more pronounced reaction was observed when the residual functional coronary stenosis was reduced in subsequent dilatations. Arteriovenous lactate difference appeared constant during the first two occlusions (control +0.11 mmol/liter, first PTCA -0.87 mmol/liter, and second PTCA -0.82 mmol/liter) and did not increase during subsequent occlusions. Within minutes after the procedure lactate balance was again positive, demonstrating the reversibility of the metabolic disturbances after repeated ischemia. The results of this study indicate that there is no permanent dysfunction of global or regional myocardial mechanics, myocardial blood flow, or lactate metabolism after PTCA with four to six coronary occlusions of 40 to 60 sec.

Angioplasty, Balloon↗

Pulmonary vascular tone is a determinant of basal lung perfusion in normal seated subjects.

In the human upright lung the downward increase in lung perfusion reverses in the lower third, thus giving rise to a zone of reduced basal perfusion (zone 4). The flow in zone 4 is regulated by the extra-alveolar vessels, the diameter of which is determined by lung volume, perivascular interstitial pressure, and vasomotor tone. To estimate the role of pulmonary vascular tone in the formation of zone 4, we infused nitroprusside (NTP), a potent pulmonary vasodilator, in six normal seated subjects. We measured their regional perfusion distribution using 133Xe in control conditions and at two dose levels of NTP (20.8 and 52.1 micrograms/min). Regional perfusion distribution was measured similarly and according to the same protocol in six subjects receiving only a placebo solution. In four of the six subjects receiving NTP, right-heart catheterization allowed simultaneous estimations of cardiac output and pulmonary arterial pressure to be made. NTP slightly decreased the perfusion of the nondependent parts of the lungs and markedly increased the perfusion of the lung bases, thus reducing the extent of zone 4. No changes were observed in the placebo experiments. Cardiac output and indices of ventilation and gas exchange did not change significantly. Peripheral and pulmonary arterial pressure fell slightly but significantly during NTP infusion. We attribute the observed changes in basal perfusion to the vasodilatory effects of NTP on the extra-alveolar vessels. Our findings thus support the hypothesis that in normal subjects zone 4 is partly created by the pulmonary vascular tone.

Adult↗

Clinical validation of fully automated computation of ejection fraction from gated equilibrium blood-pool scintigrams.

A fully automated procedure for the computation of left-ventricular ejection fraction (EF) from cardiac-gated Tc-99m blood-pool (GBP) scintigrams with fixed, dual, and variable ROI methods is described. By comparison with EF data from contrast ventriculography in 68 patients, the dual-ROI method (separate end-diastolic and end-systolic contours) was found to be the method of choice; processing time was 2 min. Success score of dual-ROI procedure was 92% as assessed from 100 GBP studies. Overall reproducibility of data acquisition and analysis was determined in 12 patients. Mean value and standard deviation of differences between repeat studies (average time interval 27 min) were 0.8% and 4.3% EF units, respectively, (r = 0.98). We conclude that left-ventricular EF can be computed automatically from GBP scintigrams with minimal operator-interaction and good reproducibility; EFs are similar to those from contrast ventriculography.

Adult↗

Contrasting effect on cardiac output of digoxin and gitoxin in humans during congestive heart failure.

Recent studies have demonstrated that the biovailability of gitoxin could be increased to 100%. Favorable pharmacokinetic parameters for this glycoside have also been found in humans. The present paper deals with the comparative hemodynamic effect of digoxin and gitoxin on nine patients suffering from heart failure. The study was conducted in a coronary care unit with continuous hemodynamic monitoring. After intravenous administration of 1 mg digoxin or gitoxin, only gitoxin was observed to have an inotropic effect leading to significant improvement of the low cardiac output in these patients.

Aged↗

Lack of adaptation of pancreatic colipase in rats and mice.

A new automated potentiometric method for the determination of colipase was developed, taking advantage of the reactivation of purified lipase, in the presence of bile salt and at pH 6.5. High-fat and high-starch diets induced an opposite regulation of lipase and amylase in the rat pancreas. At the same time, the level of colipase was not influenced by nutrition. During fasting and in alloxan diabetes, the specific activity of lipase almost doubled, that of amylase decreased sharply, and colipase was not affected in the rat pancreas. In obese-hyperglycemic mice, suffering from obesity, hyperinsulinism, and moderate diabetes, there was also no regulation of pancreatic colipase. Thus, at variance with a number of hydrolases, there was no dietary or hormonal adaptation of colipase. However, this was probably without any bearing on intraluminal lipolysis. Indeed, comparison of lipase and colipase activities in pancreas and in small intestine suggests that colipase concentration is not a limiting factor of intraluminal lipolysis. The molecular mechanism of this assumption is discussed on the basis of in vitro studies.

Adaptation, Physiological↗

The use of carbon 11-labeled acetate for assessment of aerobic metabolism.

Carbon 11-labeled acetate has been validated as a tracer of citric acid flux and indirectly of oxidative metabolism. 11C-labeled acetate is predominantly metabolized to 11C-labeled carbon dioxide, which clears from the heart. The myocardial 11CO2 efflux rate that can be estimated by dynamic positron emission tomographic imaging closely correlates with myocardial oxygen consumption over a wide range of flow, substrate use, and metabolic conditions. 11C-labeled acetate clearance rates are indirect indexes of oxidative metabolism. To provide absolute mass fluxes, the 11C-labeled acetate approach would require biochemical validation and configuration of a tracer kinetic model. Clinically, estimates of myocardial oxygen consumption appear to be useful in assessing tissue viability, as shown in patients after acute myocardial infarction or with chronic coronary artery disease. In non-coronary artery disease, 11C-labeled acetate may provide measurement of cardiac efficiency and be useful for monitoring therapy.

Acetic Acid↗

Effects of short-term intravenous administration of diltiazem on left ventricular function and coronary hemodynamics in patients with coronary artery disease.

The hemodynamic effects of diltiazem were investigated in 15 patients with suspected coronary artery disease undergoing routine cardiac catheterization. Diltiazem was given in a high dose of 500 micrograms/kg over a period of 5 min and measurements made before and after drug administration during spontaneous heart rate and during matched atrial pacing. Spontaneous heart rate did not change (-5%; NS). Left ventricular (LV) systolic pressure decreased 24% (p less than 10(-6)) and LV end-diastolic pressure (LVEDP) did not change (-5%; NS). During coronary blood flow measurement, mean aortic pressure decreased 30% (p less than 10(-6)) as global (coronary sinus) and regional (great cardiac vein) coronary vascular resistance diminished with no change in coronary blood flow. Myocardial oxygen consumption decreased 19% (p less than 0.02). During matched pacing, although no change occurred in calculated systolic isovolumic indexes of contractility, end-systolic pressure-volume index decreased 15% (p less than 0.05). The time constant of isovolumic relaxation assessed by a biexponential model decreased. No net change occurred in either global or regional wall motion. In summary, high-dose diltiazem was administered safely to patients with coronary artery disease. It is concluded that, at this dose, diltiazem acted as a peripheral and coronary vasodilator. Hemodynamic changes consistent with a direct negative inotropic and chronotropic effect of the drug were observed. Myocardial oxygen consumption decreased with no change in coronary blood flow.

Aged↗