[Ambulatory co-disciplinary risk-adjusted preoperative care].

Routine preoperative studies in asymptomatic patients are not helpful for perioperative risk evaluation, and the cost is considerable. The decision regarding the status of a patient for elective surgery can be accurately predicted in 95% of cases on the basis of a complete history and physical examination alone; selective testing should be preferred. Interdisciplinary outpatient premedication is suitable for an individual risk evaluation, and a significant reduction in cost and inpatient treatment.

Adult↗

[Determination of core body temperature. A comparison of esophageal, bladder, and rectal temperature during postoperative rewarming].

OBJECTIVE: The data of 60 postoperatively sedated and ventilated patients were studied for analysis of oesophageal, bladder, and rectal temperatures. The purpose of the investigation was to clarify whether changes of oesophageal temperature are adequately reflected by bladder and rectal temperatures and whether the rate of rewarming has an influence on the accuracy of the latter two sites. METHODS: For temperature recording, a Hi-Lo Temp esophageal stethoscope (Mallinckrodt Medical), a Foley FC400-18 catheter temperature sensor (Respiratory Support Products, Mallinckrodt Medical), and a rectal temperature probe N401 (YSI) were used. Each probe and matching recording unit was calibrated over a range of 30-40 degrees C against a reference quartz thermometer (Hewlett packard Model 2801 A) in a thermostated water bath before the investigation. Five measuring points distributed over the whole period of rewarming were evaluated. Patients were assigned to groups with slow and fast rewarming, respectively. Agreement between the methods of measurement was assessed as described by Bland and Altman. Furthermore, differences between the oesophageal and bladder or rectal temperature were checked at each measuring point for statistical significance using the t-test. RESULTS: In regard to oesophageal temperature, the bladder and rectal temperatures had biases of -0.01 degree C and -0.03 degree C, respectively. Limits of agreement (+/- s) were +/-0.68 degree C and +/-0.82 degree C, respectively. The bias of the bladder temperature was independent of the rate of rewarming (Fig. 3). The bias of the rectal temperature, however, differed in regard to the rewarming rate, being +0.06 degree C in the group with slow rewarming and -0.13 degree C in the group with fast rewarming (Tables 1 and 2, Fig. 1 and 2). These differences were significant for the measuring points 4 and 5 (Fig. 4). CONCLUSIONS: Bladder and rectal temperatures can accurately indicate the oesophageal temperature with a very small bias in postoperatively sedated and ventilated patients. Since the rate of rewarming influences the accuracy of rectal temperature readings, monitoring of bladder temperature seems to be more favourable in the postoperative period.

Body Temperature↗

[Temperature measurement in the ear canal: comparison of an infrared thermometer with conventional temperature probes and evaluation of clinical factors on infrared measurement].

PURPOSE: We compared the readings of the GENIUS 3000A FirstTemp infrared thermometer with a conventional temperature probe (MON-A-THERM tympanic) placed in contact with the tympanic membrane. We also systematically evaluated user-dependent factors influencing the infrared readings. METHODS: In 100 postoperative patients we investigated the repeatability of the infrared measurements and the agreement with tympanic thermocouple probes in the contralateral ear regarding the degree of auditory canal contamination. In 20 volunteers we evaluated the influence of three factors: interval between consecutive measurements, dwell time in the auditory canal before reading the temperature, and positioning of the grip. Finally, we compared the infrared readings in the same ear of 20 different users who were not familiar with this new method. RESULTS: Comparison with the tympanic contact probes revealed a mean difference of -0.67 degree C (+/-0.65 degree C 2 SD). The infrared thermometer significantly underestimated the temperature of the thermocouple probes. Repeatability was +/-0.3 degree C. The presence of cerumen in the auditory canal had no influence on the infrared readings. Shortening of the interval between two consecutive readings (30 and 60 s.) led to increasing differences between the two measurements with the second reading decreasing. After positioning the infrared thermometer in the auditory canal 5 seconds before taking temperatures, the recorded temperatures were significantly lower compared to the immediate temperature recordings. Rotation of the device out of the telephone handle position led to an increasing lack of agreement between infrared thermometry and thermistor probes. In 20 inexperienced operators agreement with the thermocouple probe was -0.80 degree C (+/-0.60 degree C 2 SD) and repeatability was +/-0.6 degree C. CONCLUSION: Although easy to use, infrared thermometry requires careful handling and experienced users. To get optimal recordings, the time between consecutive measurements should not be less than 90 seconds. Recordings should be taken immediately after positioning the device in the auditory canal. Best results are obtained when the grip of the device follows the ramus mandibulae like a telephone handle. The lower readings of the infrared thermometer compared to tympanic contact-probes indicate that the obtained readings represent the temperature of the auditory canal rather than of the tympanic membrane itself.

Ear Canal↗

[Is reduction of intraoperative heat loss and management of hypothermic patients with anesthetic gas climate control advisable? Heat and humidity exchangers vs. active humidifiers ina functional lung model].

UNLABELLED: Heated humidifiers (HH) as well as heat and moisture exchangers (HME) are commonly used in intubated patients as air-conditioning devices to raise the moisture content of the air, thus preventing mucosal damage and heat loss resulting from ventilation with dry inspired gases. In contrary to HME, HH are able to add heat and moisture to the inspired air in surplus, which is often stressed as an advantage in warming hypothermic patients or reducing major heat losses, e.g., during long operations. The impact of air conditioning on the energy balance of man was calculated comparing HME and HH. METHODS: The efficiency of a HME (Medisize Hygrovent) and a HH (Fisher & Paykel MR 730) was evaluated in a mechanically ventilated lung model simulating the physiological heat and humidity conditions of the upper airways. The gas flow from the central supply was dry; the model temperature varied between 32 and 40 degrees C. By using a HH in the inspiratory limb, a circle system was simulated with water-saturated inspired air at room temperature. The water content of the ventilated air was determined at the tracheal tube connection using a fast, high-resolution humidity meter and was compared with the moisture return of the HME. The energy balance was calculated according to thermodynamic laws. RESULTS: Both HME and HH were able to create physiological heat and humidity conditions in the airways. With the normothermic patient model, the moisture return of the HME was equal to that of the HH set at 34 degrees C. Increasing the heating temperature resulted only in reduced water loss from the lung; heat and water input in the normothermic model was not possible. This was only effective with almost negligible amounts under hypothermic patient model conditions. DISCUSSION: The water content in the inspired and expired air is the most important parameter for estimating pulmonary heat loss in mechanically ventilated patients. In adults (minute volume approximately 71/min) the main fraction of pulmonary heat loss results from water evaporation from the airways (approximately 6 kcal/h), whereas the heat loss due to convection is negligible (approximately 1.2 kcal/h). In intubated patients ventilated with dry air, the heat loss increases to approximately 8 kcal/h due to greater water evaporation from the airways. Both HME and HH are able to reduce the pulmonary heat loss to 1-2 kcal/h. In normothermic as well as hypothermic patients, HH do not offer significant advantages in heat balance compared to effective HME. In conclusion, air conditioning in intubated patients is neither a powerful too for maintaining body temperature during long-lasting anaesthesia nor a sufficient method of warming hypothermic patients in intensive care units.

Air Conditioning↗

[Infrared temperature measurement in the ear canal with the DIATEK 9000 Instatemp and the DIATEK 9000 Thermoguide. Comparison with methods of temperature measurement in other body parts].

UNLABELLED: Temperature of the tympanic membrane is recommended as a "gold standard" of core-temperature recording. However, use of temperature probes in the auditory canal may lead to damage of tympanic membrane. Temperature measurement in the auditory canal with infrared thermometry does not pose this risk. Furthermore it is easy to perform and not very time-consuming. For this reason infrared thermometry of the auditory canal is becoming increasingly popular in clinical practice. We evaluated two infrared thermometers-the Diatek 9000 Thermoguide and the Diatek 9000 Instatemp-regarding factors influencing agreement with conventional tympanic temperature measurement and other core-temperature recording sites. In addition, we systematically evaluated user dependent factors that influence the agreement with the tympanic temperature. MATERIALS AND METHODS: In 20 volunteers we evaluated the influence of three factors: duration of the devices in the auditory canal before taking temperature (0 or 5 s), interval between two following recordings (30, 60, 90, 120, 180 s) and positioning of the grip relative to the auditory-canal axis (0, 60, 180 and 270 degrees). Agreement with tympanic contact probes (Mon-a-therm tympanic) in the contralateral ear was investigated in 100 postoperative patients. Comparative readings with rectal (YSI series 400) and esophageal (Mon-a-therm esophageal stethoscope with temperature sensor) probes were done in 100 patients in the ICU. The method of Bland and Altman was taken for comparison. RESULTS: Shortening of the interval between two consecutive readings led to increasing differences between the two measurements with the second reading decreasing. A similar effect was seen when positioning the infrared thermometers in the auditory canal before taking temperatures: after 5 s the recorded temperatures were significantly lower than temperature recordings taken immediately. Rotation of the devices out of the telephone handle position led to increasing lack of agreement between infrared thermometry and contact probes. Mean differences between infrared thermometry (Instatemp and Thermoguide, CAL-Mode) and tympanic probes were -0.41 +/- 0.67 degree C (2 SD) and -0.43 +/- 0.70 degree C, respectively. Mean differences between the Thermoquide (Rectal-Mode) and rectal probe were -0.19 +/- 0.72 degree C, and between the Thermoguide (Core Mode) and esophageal probe -0.13 +/- 0.74 degree C. DISCUSSION: Although easy to use, infrared thermometry requires careful handling. To obtain optimal recordings, the time between two consecutive readings should not be less than two min. Recordings should be taken immediately after positioning the devices in the auditory canal. Best results are obtained in the 60 degrees position with the grip of the devices following the ramus mandibulae (telephone handle position). The lower readings of infrared thermometry compared with tympanic contact probes indicate that the readings obtained represent the temperature of the auditory canal rather than of the tympanic membrane itself. To compensate for underestimation of core temperature by infrared thermometry, the results obtained are corrected and transferred into core-equivalent temperatures. This data correction reduces mean differences between infrared recordings and traditional core-temperature monitoring, but leaves limits of agreement between the two methods uninfluenced.

Body Temperature↗

[The comparative effectiveness of different infusion and blood warming methods].

UNLABELLED: Heat loses during surgery occur mainly to the environment and due to infusions and irrigations. Infusions given at room temperature account for a great deal of the total heat deficit during major operations, e.g., the infusion of 53 ml/kg 20 degrees C fluid leads to a loss of 1 degree C in mean body temperature. Hence, heating i.v. fluids will add to the effect of other measures aimed at reducing heat loss to the environment. We investigated the efficacy of different warming methods for i.v. fluids in an experimental model by measuring the temperature at the end of the delivery line. METHODS: The following in-line warmers were studied: Hotline HL-90 and System H-250/heat exchanger D-50 (Level 1 Technologies, Marshfield, USA), Astotherm IFT 260 (Stihler Elektronic GmbH, Stuttgart, Germany), RSLB 30 H Gamida (Productions Hospitalieres Francaises, Eaubonne, France), Bair Hugger 241/Modell 500 Prototype (Augustine Medical, Eden Prairie, USA). They were compared with pre-warming infusions (39 degrees C) only using the Clinitherm S (Labor Technik Barkey GmbH, Bielefeld, Germany) and pre-warming with "active insulation" of the delivery line using the Autotherm/Autoline system (Labor Technik Barkey GmbH, Bielefeld, Germany). We investigated the influence of four variables on the efficacy of warming: (1) flow rate (50-15,000 ml/h); (2) ambient temperature (20 degrees C and 25 degrees C); (3) infusion bag temperature (6 degrees C, 20 degrees C, and 39 degrees C); and (4) length of infusion system downstream from the heat exchanger. Fluid temperatures were measured using thermistors of 1 mm diameter (Modell YSI 520, Yellow Springs Instruments Co., Yellow Springs, USA) incorporated into 3-way stopcocks. Temperatures were recorded using Hellige temperature monitors (Hellige GmbH, Freiburg im Breisgau, Germany) and the signals were collected at 10 Hz through an AD converter and averaged over 1 min. Flows were calculated by timed collection into calibrated cylinders; 10 to 12 different flow rates were taken to define one temperature/ flow plot. Effective warming was defined as a temperature > 33 degrees C at the end of the infusion line. RESULTS: At high flow rates (> 2,500 ml/h) using 20 degrees C fluids at 20 degrees C ambient temperature, the H-250/D-50 system gave the highest temperatures throughout the range and showed effective warming from 1,300 ml/h on over the entire range tested (35 degrees C at 17,000 ml/h) compared to the RSLB 30 H Gamida system (3,000-18,000 ml/h) (Fig. 2). This difference in performance was almost abolished with fluids at 6 degrees C (Fig. 4). Similar efficacy could be reached by using prewarmed infusions that gave effective warming at > 2,000 ml/h and reached 39 degrees C at 13,000 ml/h. Prewarmed infusions could be used effectively down to > 80 ml/h applying "active insulation" (Autotherm/Autoline) to the whole infusion system. The Hotline HL-90 (50-4, 700 ml/h) appeared to be the most effective in-line warmer in the low (< 250 ml/h) and middle (250-2,500 ml/h) flow range, followed by the Astotherm IFT 260 (400-4,000 ml/h), but only if used with a length of 40 cm down-stream from the heat exchanger (Fig. 1). Increasing this distance to 145 cm markedly reduced its efficacy below the range of 2,000 ml/min (1,200- 3,000 ml/h) (Fig. 5). The Bair Hugger 241 Prototype showed a narrow effective range (700-1,300 ml/h) that could be extended beyond 1,300 ml/h by the use of prewarmed infusions (Figs. 1 and 3). The performance for 6 degrees C solutions and ambient temperatures of 25 degrees C are given in Fig. 4 and Table 1. CONCLUSIONS: The importance of infusion warming increases with the amount of fluid given.(ABSTRACT TRUNCATED)

Blood Physiological Phenomena↗

[Comparison of sufentanil-propofol-anesthesia with fentanyl-propofol in major abdominal surgery].

UNLABELLED: Major abdominal surgery often leads to a marked sympathoadrenal stress response with high concentrations of plasma catecholomines, hypertension, and tachycardia. We compared the effects of sufentanil-propofol with fentanyl-propofol anaesthesia in a controlled, randomised, double-blind study of 18 ASA I-II patients aged 23-64 years undergoing major abdominal surgery. Study parameters were haemodynamics (heart rate [HR], arterial [ABP], central venous, and pulmonary arterial pressures, cardiac index [CI]), arterial catecholamine concentrations, and the median frequency of the electroencephalogram (EEG) power spectrum. METHODS: After premedication with flunitrazepam 1-2 mg, promethazine 25-50 mg, and piritramide 7.5-15 mg, a five-lead electrocardiograph and a Lifescan brain activity monitor were attached and indwelling cannulae were inserted into the radial artery and two forearm veins. A thermodilution catheter was placed in the pulmonary artery via the right internal jugular vein. Anaesthesia was induced with either fentanyl 7 micrograms/kg followed by 5 micrograms/kg.h or sufentanil 1 microgram/kg followed by 0.7 microgram/kg.h up to the end of surgery. Additional boli of the opioids were given according to set criteria, resulting in an average consumption of 9.03 micrograms/kg.h fentanyl or 1.22 micrograms/kg.h sufentanil. Propofol 2 mg/kg was given followed by 6 micrograms/kg.h up to the end of surgery. Relaxation was obtained with pancuronium 0.025-0.05 mg/kg before and after induction, after tracheal intubation, before and after skin incision, after opening of the peritoneum, and at the end of surgery. RESULTS: No significant differences were observed between the two groups with regard to the study parameters. The duration of surgery and blood loss were similar in both groups, as were patient characteristics. After induction 2 patients in each group developed thoracic rigidity, which was reversible after muscle relaxation. HR, ABP, and CI decreased significantly before skin incision; after surgical stimulation the baseline values were again reached. but not exceeded. No patient developed tachycardia (> 100/min) or hypertension (> 15% higher than baseline pressure) for longer than 10 min during the study period until the end of surgery. The plasma concentrations of epinephrine and norepinephrine decreased significantly during anaesthesia, and under maximum surgical stimulation did not increase higher than the physiological baseline concentrations. The EEG median frequencies decreased after induction, and during the entire anaesthetic period the main activity was in the delta and theta frequency bands. CONCLUSIONS: With both regimens, the sympathoadrenal stress response to major abdominal surgery was nearly completely suppressed, resulting in stable haemodynamics during the operations. Sufentanil and fentanyl were equally well suited as analgesic components of total i.v. anaesthesia with propofol.

Abdomen↗

Oxygen cost of breathing for assisted spontaneous breathing modes: investigation into three states of pulmonary function.

OBJECTIVE: We investigated the effects of continuous positive airway pressure (CPAP) and pressure support ventilation (PSV) on the oxygen cost of breathing (VO2resp) for different states of pulmonary function. Additionally VO2resp was measured during spontaneous breathing. DESIGN: This was done in a controlled and prospective study. Ventilatory modes were applied randomly. SETTING: Measurements were performed in a quiet room on volunteers (VOL) and inpatients treated for chronic obstructive pulmonary disease (COPD). Post-operative patients after aortocoronary bypass surgery (ACB) were studied on the cardio-thoracic intensive care unit just before and after extubation. PATIENTS: Healthy volunteers (n = 14), postoperative patients after aorto-coronary bypass surgery (n = 15) and patients with COPD (n = 9, xFEV1 47.7%) were the objects of study. INTERVENTIONS: Demand flow CPAP (5 mbar) and PSV (7 mbar, PEEP 5 mbar), using the Hamilton Veolar ventilator, were investigated in comparison to spontaneous breathing. MEASUREMENTS AND RESULTS: VO2 was measured by a Datex Deltatrac metabolic monitor. VO2resp was calculated by subtraction of total oxygen uptake (VO2tot) in controlled mode ventilation (CMV) from that in the respective spontaneous breathing mode. For VOL and COPD patients who were not intubated, a CPAP facemask connected to a short 7.5 mm tube was used as connection to the ventilator. Breathing spontaneously under a canopy system VOL showed a VO2resp of 4.5 +/- 4.0% compared to 9.2 +/- 3.5% for ACB and 15.4 +/- 7.7% for COPD. CPAP changed the VO2resp to 7.8 +/- 3.9%, 12.0 +/- 4.0% and 9.1 +/- 3.6% respectively. PSV reduced the VO2resp to 7.9 +/- 3.8% in ACB and 7.7 +/- 5.5% in COPD. CONCLUSIONS: This investigation confirms findings that postoperative patients have a mild increase in VO2resp. COPD exhibit the highest increase in VO2resp. Tracheal tubes, masks and CPAP on a demand flow apparatus increases VO2resp in volunteers and postoperative patients after cardiac surgery. The same amount of CPAP in contrary reduces VO2resp in patients with COPD. Pressure support ventilation can offset the additional VO2resp induced by CPAP but at the same level does not further reduce VO2resp in COPD patients.

Adult↗

[The effect of an intracardiac left-right shunt on thermodilution measurements of cardiac output. An extracorporeal circulation model].

Thermodilution measurements of cardiac output (CO) by means of Swan-Ganz catheters, in a strict sense, represent pulmonary arterial blood flow (PBF). In principle, this is also true in the presence of intracardiac left-to-right shunts due to atrial or ventricular septal defects. However, early recirculation of indicator may give rise to serious methodological problems in these cases. We sought to determine the influence of intracardiac left-to-right shunts on different devices for thermodilution measurements of CO using an extra-corporeal flow model. METHODS. Blood flow was regulated by means of a centrifugal pump that at the same time enabled complete mixing of the indicator after injection (Fig. 1). Pulmonary and systemic parts of the circulation were simulated using two membrane oxygenators and a systemic-venous reservoir to delay systemic recirculation of indicator. Control measurements of PBF (Qp) and systemic (Qs) blood flow were performed by calibrated electromagnetic flow-meters (EMF). Blood temperature was kept constant using a heat exchanger without altering the indicator mass balance in the pulmonary circulation. Left-to-right shunt was varied at different systemic flow levels applying a Qp:Qs ratio ranging from 1:1 to 2.5:1. Thermodilution measurements of PBF were performed using two different thermodilution catheters that were connected to commercially available CO computers. Additionally, thermodilution curves were recorded on a microcomputer and analysed with custom-made software that enabled iterative regression analyses of the initial decay to determine that part of the downslope that best fits a mono-exponentially declining function. Extrapolation of the thermodilution curve was then based on the respective curve segment in order to eliminate indicator recirculation due to shunt flow. RESULTS. At moderate left-to-right shunts (Qp:Qs < 2:1) all thermodilution measurements showed close agreement with control measurements. At higher shunt flows (Qp:Qs > or = 2:1), however, conventional extrapolation procedures of CO computers considerably underestimated PBF (Fig. 2). This was particularly true when a slow-response thermistor catheter was used (Fig. 3). The reason for this underestimation of Qp was an overestimation of the area under curve because of inadequate mathematical elimination of indicator recirculation by standard truncation methods (Fig. 4). However, curve-alert messages of the commercially implemented software did not occur. A high level of agreement could be consistently obtained using a fast-response thermistor together with individual definition of extrapolation limits according to logarithmic regression analyses. DISCUSSION AND CONCLUSION. Under varying levels of left-to-right shunt, both the response time of thermodilution catheters and the algorithms for calculation of flow considerably influenced the validity of thermodilution measurements of PBF in an extracorporeal flow model. The use of computer-based regression analyses to define the optimal segment for monoexponential extrapolation could effectively eliminate indicator recirculation from the initial portion of the declining thermodilution curve and showed the closest agreement with EMF measurements of Qp. The quality of thermodilution curves with respect to recirculation peaks in the flow model was slightly better than in clinical routine. Nevertheless, the clinical applicability of the modified extrapolation algorithm could be illustrated during pulmonary thermodilution measurements in an exemplary patient with a ventricular septal defect (Fig. 5). PBF at extremely high shunt ratios, however, cannot be assessed by monoexponential extrapolation in principle (Fig. 6). Insufficient elimination of indicator recirculation resulted in flow values that closely resembled systemic rather than PBF. This finding is in accordance with a mathematical analysis of the underlying Steward-Hamilton equation if an infinite number of recirculations would be

Cardiac Output↗

[Heat and moisture exchangers for conditioning of inspired air of intubated patients in intensive care. The humidification properties of passive air exchangers under clinical conditions].

Heat and moisture exchangers (HME) are used as artificial noses for intubated patients to prevent tracheo-bronchial or pulmonary damage resulting from dry and cold inspired gases. HME are mounted directly on the tracheal tube, where they collect a large fraction of the heat and moisture of the expired air, adding this to the subsequent inspired breath. The effective performance depends on the water-retention capacity of the HME: the amount of water added to the inspired gas cannot exceed the stored water uptake of the previous breath. This study evaluates the efficiency of four different HME under laboratory and clinical conditions using a new moisture-measuring device. METHODS. In a first step, the absolute efficiency of four different HME (DAR Hygrobac, Gibeck Humid-Vent 2P, Pall BB 22-15 T, and Pall BB 100) was evaluated using a lung model simulating physiological heat and humidity conditions of the upper airways. The model was ventilated with tidal volumes of 500, 1,000, and 1,500 ml and different flow rates. The water content of the ventilated air was determined between tracheal tube and HME using a new high-resolution humidity meter and compared with the absolute water loss of the exhaled air at the gas outlet of a Siemens Servo C ventilator measured with a dew-point hygrometer. Secondly, the moisturizing efficiency was evaluated under clinical conditions in an intensive care unit with 25 intubated patients. Maintaining the ventilatory conditions for each patient, the HME were randomly changed. The humidity data were determined as described above and compared with the laboratory findings. RESULTS AND DISCUSSION. The water content at the respirator outlet is inversely equivalent to the humidity of the inspired gases and represents the water loss from the respiratory tract if the patient is ventilated with dry gases. Moisture retention and heating capacity decreased with higher volumes and higher flow rates. These data are simple to obtain without affecting the patient and can easily be interpreted. It was demonstrated that, compared to physiological conditions, the DAR Hygrobac and Gibeck Humid Vent 2P-HME coated with hygroscopic salts-were able to maintain sufficient inspiratory humidity and heat. The Pall-HME, solely a condensation humidifier, did not meet the physiological requirements.

Adult↗

Effect of ketanserin on global cerebral blood flow and middle cerebral artery flow velocity.

The aim of this study was to examine the influence of ketanserin, a 5-hydroxytryptamine antagonist antihypertensive agent, on the relationship between cerebral blood flow (CBF) and middle cerebral artery flow velocity (Vmean MCA) and to compare Doppler-sonographic indices of downstream resistance (pulsatility index, PI; resistance index, RI) with calculations of cerebrovascular resistance (CVR) in 17 male patients under fentanyl/midazolam anesthesia. CBF was measured with the Kety-Schmidt technique using argon as a tracer. Cerebral perfusion pressure (CPP) was calculated as the difference between mean arterial pressure (MAP) and jugular bulb pressure. Measurements of Vmean MCA and determinations of PI and RI were performed by use of a 2-MHz transcranial Doppler ultrasound device. All variables were measured at normo- and moderate hypocapnia before and after intravenous (i.v.) bolus administration of 0.3 mg/kg ketanserin followed by an infusion of 0.06 mg.kg-1.h-1. Ketanserin changed neither average CBF nor Vmean MCA. The CO2 reactivity of Vmean MCA was significantly lower than the CO2 reactivity of CBF (P < 0.01); however, ketanserin did not change the relationship between CBF and Vmean MCA. During hypocapnia, CVR as well as PI and RI significantly increased (P < or = 0.01), indicating consistent directional changes in arteriolar resistance and flow velocity pulsatility. In contrast, after i.v. administration of ketanserin, CVR decreased (P < 0.05), whereas both Doppler-derived indices increased (P < 0.01). These results suggest that ketanserin in a clinically relevant dose does not alter the validity of serial Vmean MCA measurements as an index of global CBF and that ketanserin does not change the diameter of middle cerebral arteries (MCAs). Doppler-derived indices of pulsatility and resistance, which are supposed to estimate changes in downstream resistance, reflect changes, after administration of ketanserin, in systemic hemodynamics rather than changes in CVR.

Adult↗

A new paediatric metabolic monitor.

OBJECTIVE: A paediatric option for the measurement of VO2 and VCO2 (20 to 150 ml/min) has recently been introduced for the adult Deltatrac metabolic monitor (Datex Instrumentarium, Finland) to use in ventilated and spontaneously breathing children. This paper describes a laboratory validation of the paediatric option for ventilated children with regard to the influence of respiratory variables. DESIGN: Respiratory variables were varied within the following ranges: FIO2 0.21-0.8, FIO2-FEO2 (DFO2) 0.01-0.05, FECO2 0.01-0.05, VE 300-6000 ml/min, VT 8-300 ml, RR 10-50/min, P(aw) 10-60 mbar, relative humidity 10% and 60%, and resulted in 107 test situations. SETTING: Gas exchange was simulated by injection of nitrogen and CO2 at a RQ close to 1. PATIENTS OR PARTICIPANTS: Different situations of paediatric patients ventilated in controlled mode were simulated on a gas injection model. INTERVENTIONS: Respiratory and metabolic variables were varied independently to result in a range of 8 to 210 ml/min of VO2 and VCO2. MEASUREMENTS AND RESULTS: Reference measurements were carried out by mass spectrometry and wet gas spirometry. The mean VCO2 difference for all tests ranging from 20 ml/min to 210 ml/min was -2.4% (2SD = +/- 12%). The respective VO2 difference was -3.2% (2SD = +/- 23%). Measurement agreement for VO2 in neonatal respirator treatment (20-50 ml/min) compared to older children (50-210 ml/min) showed a mean difference of -3.9% (2SD = +/- 26%) versus -2.8% (2SD = +/- 20%). The respective differences for VCO2 were -7.1% (2SD = +/- 7%) versus +0.4% (2SD = +/- 10%). The mean difference for VO2 as well as VCO2 indicated a high systematic agreement of both methods. The variability (+/- 2SD) in VCO2 measurement is acceptable for all applications. The overall variability in VO2 measurement (2SD = +/- 23%) can be reduced by exclusion of all tests with a FECO2 and DFO2 below 0.03. This results in a mean difference of -3.2% (2SD = +/- 13.7%). CONCLUSION: Within this limitation the paediatric measurement option seems to introduce a valuable method for clinical application in paediatric intensive care medicine.

Calibration↗

[Postoperative warming therapy in the recovery room. A comparison of radiative and convective warmers].

Hypothermia (Tcore < 36 degrees C) can be observed in 60%-80% of all admissions to the post-anaesthetic recovery unit. Effective warming devices may accelerate rewarming, improve patient comfort, and suppress shivering thermogenesis. This study was designed to compare the efficiency of warming devices in extubated postoperative patients and their effect on postoperative oxygen uptake (VO2). METHODS. Thirty-five ASA I and II patients after laparoscopic hernioplastic repair with core temperatures < 36 degrees C were randomly assigned to either postoperative nursing under a radiant heater (group R, n = 11, Aragona Thermal Ceilings CTC X, Aragona Medical AB, Täby, Sweden), a forced air system (group L, n = 12, Bair Hugger, Augustine Medical Inc., Eden Prairie, Minnesota, USA), or a normal cotton hospital blanket (group K, n = 12). Anaesthesia was conducted totally intravenously with propofol, alfentanil, and vecuronium. Mean body temperature and total body heat were calculated from urinary bladder temperature and four subcutaneous temperature measurements. The rate of thermogenesis was calculated from continuous measurement of VO2 (Datex Deltatrac Metabolic Monitor, Datex Instrumentarium Corp., Helsinki, Finland). Heat balance was derived from the increase in total body heat minus body heat production. Heart rate and noninvasive blood pressure were measured by the Cardiocap (Datex Instrumentarium Corp., Helsinki, Finland). All data were transferred to an IBM-compatible computer at 60-s intervals. Measurements were stopped when core temperature reached 37 degrees C. The rate of change was calculated for each variable for the period 15 min after the beginning of rewarming to attainment of 37 degrees C. Data are presented as median, minima, and maxima (min<==>max); the Mann-Whitney U test was used to test for significance of group differences. RESULTS. All groups were comparable for body weight, height, age, and amount of postoperative infusions. Temperatures at admission were 35.2 (33.4<==>35.9), 34.7 (34.3<==>35.8), and 35.4 (34.3<==>35.9) degrees C for groups R, B, and K, respectively. No significant differences in the rate of central rewarming could be found for these groups with 0.81 (0.41<==>1.32), 0.76 (0.40<==>1.07), and 0.70 (0.37<==>1.13) degrees C/h (Fig. 1). The mean VO2 of 3.41 (3.07<==>3.73), 3.55 (2.78<==>4.06), and 3.79 (2.51<==>7.00) ml/kg/min also did not differ significantly (Fig. 3). Significant differences between groups R and B [4.39 (3.74<==>6.19) and 4.30 (3.46<==>6.67) ml/kg/min] and K [5.92 (3.79<==>10.64) ml/kg/min] were found for VO2 maxima during the course of investigation (Fig. 4). The heat balance revealed significant differences among treatment and control groups with -88 (-226<==>+30), -41 (-212<==>+12), and -191 (-265<==>-86) kJ/h for groups R, B, and K. We additionally calculated the heat balance as a quotient, which showed 0.70 (0.22<==>1.07), 0.86 (0.44<==>1.04), and 0.49 (0.31<==>0.79) for groups R, B, and K (Fig. 4). The mean rate-pressure product of all groups did not differ significantly during the period of investigation. CONCLUSIONS. Neither external heat supply by radiant heat nor by a forced warm air system significantly reduced rewarming time in extubated, awake patients. As measured by heat balance, both active treatments saved about 20% more body heat production than in the control group. Continuing peripheral vasoconstriction may be the reason for the low efficiency of heat transfer. Thermal treatment did reduce the peak load (max. VO2) on the oxygen transport systems, though shivering was treated by pethidine if it occurred. External rewarming did not reduce the average load (mean VO2). Thus, concerning the goal of accelerating rewarming, it appears more rational to prevent intraoperative heat loss. For a comparison of efficiency of different warming devices, postoperative extubated patients do not appear to be an ideal model for study.

Adult↗

[Inverse fick's principle in comparison to measurements of oxygen consumption in respiratory gases. Does intrapulmonary oxygen uptake account for differences shown by different system methods?].

Automated measurements of respiratory gas exchange recently became available for the determination of oxygen uptake (VO2) in critically ill patients. Whereas these metabolic gas monitoring systems (MBM) are assumed to measure total body VO2, the reversed Fick method in principle excludes intrapulmonary VO2. Previous clinical reports comparing VO2 measured by the reversed Fick principle (VO2Fick) with VO2 measured by MBM (VO2MBM) found that VO2MBM was significantly greater than VO2Fick. It was suggested that these differences between methods represent VO2 of pulmonary and bronchial tissue, as intrapulmonary VO2 had been estimated to account for 15% of total body VO2 in dogs with experimental pneumonia. The objective of this study was to compare VO2Fick with VO2MBM in patients with and without pneumonia and to assess the reproducibility of both methods in critically ill patients. METHOD. With institutional approval nine critically ill patients with acute pneumonia were studied under controlled mechanical ventilation. The diagnosis of pneumonia was based on respective changes of chest X-rays, body temperature > 38 degrees C, and WBC counts > 12,000/mm3. Inspiratory oxygen fractions (FIO2) ranged from 0.3 to 0.6; all patients routinely received opioids and hypnotics. Complete muscle relaxation was achieved during the periods of measurement to avoid sudden changes in VO2 due to shivering or involuntary movements. Arterial and pulmonary-arterial blood samples were drawn simultaneously after aspiration of the sevenfold catheter dead space. Measurements of haemoglobin concentration (Hb), fractional oxygen saturation (SO2), and O2 partial pressure (PO2) were performed by use of a calibrated haemoximeter and blood gas analyser, respectively; 2 x 5 thermodilution measurements of cardiac output (CO) were spread randomly over the respiratory cycle for each determination of VO2Fick. To minimise systematic errors of CO measurements, the CO computer was calibrated in an extracorporeal flow model using an electromagnetic flowmeter. Calculations of VO2Fick were based on an oxygen binding capacity of 1.39 ml/g Hb. Simultaneous measurements of VO2MBM were obtained by use of a Datex Deltatrac MBM that had been validated in vitro with a gas dilution model of respiratory gas exchange. Calibration of the MBM was performed prior to each measurement. Gas supply of the respirator was provided by an external high-precision mixing device to reduce errors in VO2 measurements that may arise from short-term oscillations in FIO2. All patients with pneumonia were studied on three consecutive days; thus, measurements from 27 days could be analysed. On each day two sets of measurements were performed at an interval of 60 min to assess the reproducibility of differences between methods. During each set of measurements duplicate blood samples were drawn twice, before and after thermodilution measurements of CO, to evaluate the short-term repeatability of VO2Fick. The beginning and the end of each set of measurements were marked in the computer record of the MBM to assess the respective repeatability of VO2MBM. Fifty control measurements were performed in ten patients undergoing major neurosurgical procedures. None of these patients exhibited signs of pulmonary infection. Except for the number of repeated measures, all VO2 measurements were obtained in the same way as in the study group. Descriptive statistical analysis was performed according to Bland and Altman; comparisons between methods were done by multivariate analysis of variance for repeated measures. RESULTS. Neither in the study group nor in the control group could a significant difference between methods be demonstrated. In patients with pneumonia the mean difference between methods (VO2Fick-VO2MBM) was 15.2 ml/min (4.2%); the double standard deviation of differences (2 SD) was 59.2 ml/min (19.2%).

Blood Gas Analysis↗

Flow velocity measurements as an index of cerebral blood flow. Validity of transcranial Doppler sonographic monitoring during cardiac surgery.

BACKGROUND: Transcranial Doppler sonography is increasingly used to monitor changes in cerebral perfusion intraoperatively. However, little information is available about the validity of velocity measurements as an index of cerebral blood flow (CBF). The purpose of this study was to compare invasive and Doppler-derived measurements of cerebral hemodynamic variables during coronary artery bypass graft surgery. METHODS: In 15 male patients, measurements of CBF and middle cerebral artery flow velocity (VMCA) were performed before and after induction of fentanyl-midazolam anesthesia, during hypothermic cardiopulmonary bypass (CPB), and at the end of the surgical procedure. Transcranial Doppler sonography recordings of systolic, diastolic, and mean VMCA, and derived parameters such as pulsatility (PI) and resistance (RI) indexes were recorded from the proximal segment of the right middle cerebral artery. CBF was measured by the Kety-Schmidt inert gas saturation method with argon as a tracer. To facilitate comparisons of CBF and VMCA measurements, changes between consecutive measurements were expressed as percentage values. Calculations of cerebral perfusion pressure and cerebral vascular resistance (CVR) were based on jugular bulb pressure. The cerebral metabolic rate for oxygen was calculated from CBF and the arterial-cerebral venous oxygen content difference. RESULTS: Changes in mean VMCA paralleled changes in mean CBF except for hemodynamic changes associated with hypothermic CPB. At this stage of surgery, mean VMCA increased while actual CBF decreased. Separate analysis of the periods before and after CPB revealed a poor association between percentage changes in CBF and VMCA (r = 0.26, P = 0.36; r = 0.51, P = 0.06, respectively). Mean values of CVR, PI, and RI showed consistent changes after induction of anesthesia. After termination of CPB, mean CVR significantly decreased, whereas mean PI and RI remained virtually unchanged. Neither before nor after CPB was a clinically useful correlation found between percentage changes in PI, RI, and CVR (PI r = 0.28, P = 0.34; r = -0.47, P = 0.09, respectively; RI r = 0.16, P = 0.59; r = -0.53, P = 0.06, respectively). CONCLUSIONS: Hypothermic CPB seems to alter the relation between global CBF and flow velocity in basal cerebral arteries. Inconsistency in directional changes in CBF and VMCA at this stage of surgery might be attributable to changes in middle cerebral artery diameter, red blood cell velocity spectra, and regional flow distribution. Although changes in mean VMCA before and after CPB appear to parallel changes in mean CBF, individual responses of VMCA cannot reliably predict percentage changes in CBF. Furthermore, Doppler sonographic PI and RI cannot provide an approximation of changes in CVR during cardiac surgery.

Aged↗

A ventilator with an integrated gas-exchange monitoring function.

OBJECTIVE: To evaluate in the laboratory a new ventilator with a built-in monitoring function for gas exchange. DESIGN: Prospective laboratory evaluation of a new mechanical ventilator. SETTING: Gas exchange was simulated by injecting nitrogen and CO2 at a respiratory exchange ratio close to 1. SUBJECTS: Different settings of controlled-mode ventilation were simulated by the gas-injection model, which permitted an independent adjustment of variables. INTERVENTIONS: The influence of respiratory variables on oxygen consumption (VO2) and the CO2 production (VCO2) agreement with a reference method was investigated. MEASUREMENTS AND MAIN RESULTS: Independent variables, which may influence the accuracy and precision of the tested device, were adjusted systematically within the following ranges and resulted in 71 different combinations: FIO2 0.21 to 0.59; FIO2-mixed FEO2 0.02 to 0.05; mixed FECO2 0.02 to 0.05; inspiratory flow rate 25 to 120 L/min; inspiratory minute volume 4200 to 11,200 mL/min; tidal volume 420 to 1120 mL; respiratory rate 6 to 16 breaths/min; airway pressure 5 to 30 cm H2O. The resulting range for both VO2 and VCO2 was 140 to 390 mL/min. For each test situation, two reference measurements were taken by mass spectrometry and wet gas spirometry. Twelve measurements were taken by the gas-exchange measurement function of the tested ventilator. The two-fold standard deviation (SD) for repeated measurement differences was chosen to quantify the repeatability within each method. This repeatability coefficient gave 5.9 (4.7) mL/min for VO2 (VCO2) within the gas-exchange measurement function, compared with 3.6 (3.1) mL/min within the reference method measurements. The mean intermethod difference (test monitor--reference method) for VCO2 over all test situations was 4.1 +/- 10.7 (2 SD)%. The respective mean VO2 difference was 7.8 +/- 12.2 (2 SD)%. Eliminating test situations with inspiratory flow rates < 50 L/min (remaining n = 46) reduced the mean VO2 difference and variability by one third to 5.4 +/- 8.0 (2 SD)%. CONCLUSIONS: Assuming that limits of agreement for intermethod differences of +/- 20% are clinically acceptable, the VCO2 measurement indicates an acceptable accuracy and precision under controlled ventilation. The respective agreement for the VO2 measurement is lower, but still within the acceptable range. The systematic difference of the VO2 and the VCO2 is mainly influenced by a +8% bias in the inspiratory minute volume measurement, which seems especially susceptible to ventilator settings with inspiratory flow rates of < 50 L/min. An improvement of the minute volume detection would be desirable.

Analysis of Variance↗

Efficiency of a new radiant heater for postoperative rewarming.

Effective rewarming devices have only become available recently. This investigation compares the efficiency of an new overhead radiant heater (ARAGONA Thermal Ceilings TM, CTCX, 1000 W) with that of an electric blanket (50 W) or a standard hospital blanket. 35 patients undergoing postoperative assisted ventilation and continued sedation were randomly assigned to one of the treatments. Shivering, oxygen uptake, heart rate and invasive blood pressure were measured and the increase in total body heat minus body heat production was calculated as heat balance. Results are given as medians (range). Subcutaneous temperatures were taken to calculate the mean skin temperature. The evaluation was undertaken for an oesophageal temperature interval of 35 degrees to 37 degrees C. All groups exhibited a similar mean oxygen uptake i.e. thermogenesis (3.5 (2.7-4.0) ml.kg-1.min-1, 3.3 (2.7-4.9) ml.kg-1.min-1;3.2 (2.4-5.1) ml.kg-1. min-1) which correspond to a resting energy expenditure. The time of rewarming of the radiant heat treated group (n = 12) (100 (76-143) min) for this interval was significantly reduced in comparison to both other groups (183 (116-320) min; 231 (115-340) min). A slightly positive heat balance was only achieved in the group treated by radiant heat, indicating that all metabolic heat was conserved or heat losses were compensated by transfer of external heat. Shivering was significantly reduced in the radiant heater group whereas the rate pressure product was insignificantly higher. We did not find any significant effect for the electric heating blanket in comparison to the control group.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗