Search PubMed⌕ Search

Biomedical subjects

W W Lu

Publications and source records attributed to W W Lu.

At least 37 records · Page 2Linked to original sources

Ultrastructural study of mineralization of a strontium-containing hydroxyapatite (Sr-HA) cement in vivo.

The purpose of this study was to investigate the mineralization leading to osseointegration of strontium-containing hydroxyapatite (Sr-HA) bioactive bone cement injected into cancellous bone in vivo. Sr-HA cement was injected into the ilium of rabbits for 1, 3, and 6 months. The bone mineralization area was found to be largest at 3 months, then at 1 month, and smallest at 6 months (p < 0.01) measured with tetracycline labeling. Osseointegration of Sr-HA cement was achieved at 3 months as observed by scanning electron microscopy. A high calcium and phosphorus area was observed at the interface of bone-Sr-HA cement determined by energy-dispersive X-ray analysis. Transmission electron microscopy gave evidence of the mechanism of bone formation. Dissolution of Sr-HA into debris by the bone remodeling process was thought to increase the concentration of calcium and phosphorus at the interface of bone-Sr-HA cement and stimulate bone formation. Crystalline Sr-HA formed an amorphous layer and dissolved into the surrounding solution, then apatite crystallites were precipitated and formed new bone at 3 months. This young bone then becomes mature bone, which bonds tightly to the Sr-HA cement with collagen fibers inserted perpendicularly after 6 months.

Animals↗

The flexion-extension profile of lumbar spine in 100 healthy volunteers.

STUDY DESIGN: Dynamic lumbar flexion-extension motions were assessed by an electrogoniometer and a videofluoroscopy unit simultaneously. OBJECTIVES: The aims of this study were to assess the motion profile of lumbar spine in different genders and age groups and to assess their differences. SUMMARY OF BACKGROUNDS DATA: The dynamic lumbar flexion-extension motions analysis method has been developed and validated. However, data profile of the spinal motions of healthy volunteers has not been established. METHODS.: A total of 100 healthy volunteers, including 50 men and 50 women, were recruited. They were then divided into four equal groups, following their age ranges of 21 to 30 years, 31 to 40 years, 41 to 50 years, and 51 years and older. Lumbar flexion-extension motion was assessed with an electrogoniometer and videofluoroscopy simultaneously. Radiologic images of the lumbar spine were captured during flexion-extension in 10 degrees intervals. Intervertebral flexion-extension (IVFE) of each vertebral level was calculated. The spinal motion of different genders was compared segment by segment with independent t test. The spinal motion of different age groups was compared with one-way analysis of variance. RESULTS: A linear-liked pattern of the IVFE curves was observed in different genders and age groups. No statistically significant difference in the pattern of motion was found between genders. However, statistically significant difference in the slope of IVFE curves was found at all lumbar levels in subjects whose age was 51 years or older (P < 0.05). CONCLUSIONS: Assessment of motion profile was found to be helpful for the identification of spinal disorders in clinical practice. Because of the normal variation of spinal motion of subjects in different age ranges, interpretation of spinal motion disorders should be careful. Although the sample size in this study was limited, the database generated might be useful to assist the diagnosis of spinal "instability" in the future.

Adult↗

Microfracture and changes in energy absorption to fracture of young vertebral cancellous bone following physiological fatigue loading.

STUDY DESIGN: Fifty-five human thoracolumbar vertebrae were randomly fatigue loaded and analyzed. OBJECTIVES: The purpose of this study was to explore the relationship between fatigue loading, trabecular microfracture, and energy absorption to fracture in human cadaveric thoracolumbar vertebrae. BACKGROUND: Although trabecular microfractures are found in vivo and have been produced by fatigue loading in vitro, the effect of the level of physiologic fatigue loading on microfracture and energy absorption has not been investigated. METHODS: Fifty-five human thoracolumbar vertebrae (T11-L4) were randomly divided into 5 groups: 1) control (no loading, n = 6); 2) axial compression to yield (n = 7); and 3-5) 20,000 cycles of fatigue loading at 2 Hz (each n = 14). The level of fatigue loading was determined as a proportion of the yield load of Group 2 as follows: 10% (Group 3), 20% (Group 4), and 30% (Group 5). Half of the specimens in groups 3 to 5 were used for radiographic and histomorphometric analysis to determine microfracture density and distribution, whereas the other half were tested to determine the energy absorption to yield failure. RESULTS: No radiographic evidence of gross fracture was found in any of the groups following fatigue loading. A mean 7.5% increase in stiffness was found in specimens subject to cyclic loading at 10% of yield stress (Group 3). Fatigue at 20% (Group 4) and 30% of yield stress (Group 5) caused significantly higher (P < 0.05) increases in mean stiffness of 23.6% and 24.2%, respectively. Microfracture density increased from 0.46/mm in Group 3 to 0.66/mm in Group 4 and 0.94/mm in Group 5 (P < 0.05). The energy absorbed to failure decreased from 21.9 J in Group 3 to 18.1 J and 19.6 J in Groups 4 and 5, respectively (P < 0.05). CONCLUSIONS: Fatigue loading at physiologic levels produced microfractures that are not detectable by radiography. Increased fatigue load results in an increase in microfracture density and decrease energy absorbed to fracture, indicating a reduced resistance to further fatigue loading.

Absorptiometry, Photon↗

Surface treatment of injectable strontium-containing bioactive bone cement for vertebroplasty.

A novel injectable bioactive bone-bonding cement (SrHAC) composed of strontium-containing hydroxyapatite (Sr-HA) as the inorganic filler and bisphenol A diglycidylether dimethacrylate (Bis-GMA) as the organic matrix for vertebroplasty was developed previously. In this study, the Sr-HA powders were surface treated with methyl methacrylate (MMA) to improve the interface integration of the two phases. After surface treatment, the compression strength and Young's modulus, which were tested after immersion in distilled water at 37 degrees C for 24 h according to ISO 5833, were increased by 68.65 % (p <.001) and 31.02% (p <.001), respectively. The bending strength and bending stiffness of the bioactive bone cement were significantly improved by 54.44% (p <.001) and 83.90% (p <.001). In addition, the handling property of the cement was also enhanced. In vitro biomechanical testing showed that the stiffness of the fractured spine recovered to 82.5% (p <.01) of the intact condition after cementation with surface-treated SrHAC. The failure load of the spine cemented with original and MMA-treated SrHAC improved by 14.25% (p <.05) and 46.91% (p <.05) in comparison with the fractured spines. Results from this study revealed that the MMA-treated SrHAC has a better mechanical effect for orthopedic applications.

Animals↗

In vivo cancellous bone remodeling on a strontium-containing hydroxyapatite (sr-HA) bioactive cement.

The purpose of this study was to investigate the in vivo bone response to the strontium-containing hydroxyapatite (Sr-HA) bioactive bone cement injected into the cancellous bone. Sr-HA cement was injected into the iliac crest of rabbits for 1, 3, and 6 months. Active bone formation and remodeling were observed after 1 month. Newly formed bone was observed to grow onto the bone cement after 3 months. Thick osteoid layer with osteoblasts formed along the bone and guided over the bone cement surface reflected the stimulating effect of Sr-HA. From scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX) analysis, high calcium and phosphorus levels were detected at the interface with a thick layer of 70 microm in width, and fusion of Sr-HA with the bone was observed. Blood vessels were found developing in remodeling sites. The affinity of bone on Sr-HA cement was increased from 73.55 +/- 3.50% after 3 months up to 85.15 +/- 2.74% after 6 months (p < 0.01). In contrast to Sr-HA cement, poly(methyl methacrylate) (PMMA) bone cement was neither osteoconductive nor bioresorbable. Results show that the Sr-HA cement is biocompatible and osteoconductive, which is suitable for use in treating osteoporotic vertebral fractures.

Animals↗

Spinal flexibility increase after chymopapain injection is dose dependent: a possible alternative to anterior release in scoliosis.

STUDY DESIGN: Experimental animal study. OBJECTIVES: To investigate whether the increase in spinal flexibility after chymopapain injection is dose dependent and determine the "optimal" dosage of chymopapain to increase spinal flexibility in a rabbit model. SUMMARY OF BACKGROUND DATA: Spinal instability after chymopapain injection may result in severe back pain. However, this undesired mechanical effect in treating disc herniation may provide a safe minimally invasive approach for anterior spinal release in scoliosis correction. METHODS: A total of 138 lumbar intervertebral discs from 46 New Zealand white rabbits were randomly injected with chymopapain at 6.25, 12.5, 25, 50, 75, and 100 picokatals (pKats)/0.05 mL/disc. The rabbits were killed 1 week after the injection, and the lateral bending stiffness of the spinal segments without posterior elements was determined. RESULTS: The lateral bending spinal stiffness showed no significant change after injection of 6.25 and 12.5 pKats/0.05 mL/disc but reduced significantly following chymopapain injection of 25, 50, 75, and 100 pKats (all P < 0.05 by post hoc least significant difference tests). While the lateral bending stiffness was lowest at the 100-pKats dose, there were no significant differences between the four higher dosages. CONCLUSION: The reduction in the lateral bending spinal stiffness after chymopapain injection is dose dependent, and an optimal dosage for spinal release existed; doses greater than the optimal dosage did not result in further significant decrease in lateral bending spinal stiffness.

Animals↗

Strengthening mechanisms of bone bonding to crystalline hydroxyapatite in vivo.

The formation and strengthening mechanisms of bone bonding of crystalline hydroxyapatite (HA) has been investigated using high-resolution transmission electron microscope (HRTEM) and energy-dispersive X-ray (EDX) analysis. A series of results were obtained: (i) a layer of amorphous HA, which has almost the same chemistry as the implanted HA, was formed on the surface of crystalline HA particles prior to dissolution; (ii) at 3 months a bone-like tissue formed a bonding zone between mature bone and the HA implant, composed of nanocrystalline and amorphous apatite; and (iii) at 6 months, mature bone was in direct contact with HA particles, and collagen fibres were perpendicularly inserted into the surface layer of implanted HA crystals. Findings (i) and (ii) indicated the following dissolution-precipitation process. (i) The crystalline HA transforms into amorphous HA; (ii) the amorphous HA dissolves into the surrounding solution, resulting in over-saturation; and (iii) the nanocrystallites are precipitated from the over-saturated solution in the presence of collagen fibres. A preliminary analysis indicated several conclusions: (i) the transition from crystalline to amorphous HA might be the controlling step in the bone bonding of crystalline HA; (ii) biological interdigitation (or incorporation) of collagen fibres with HA and chemical bonding of a apatite layer were both necessary to strengthen and toughen a bone bond, not only for the bonding between bone and HA at 6 months, but also for the bonding zone at 3 months, which would otherwise be very fragile due to the inherited brittleness of polycrystalline ceramics; and (iii) perpendicular interdigitation is an effective way for collagen fibres to impart their unique combination of flexibility and strength to the interface which they are keying.

Adhesiveness↗

Isokinetic and isometric lifting capacity of Chinese in relation to the physical demand of job.

The aim of the study was to formulate normative data for the lifting capacities of a normal Chinese population, in order to establish a basic foundation for further studies and to investigate the relationship between individual attributes including age, gender, height, weight, job physical demand and each type of lifting capacity. Isokinetic and isometric lifting strength at low, waist and shoulder assessment levels were measured using the LIDO Workset II based on a sample of 93 normal Chinese adults (63 men and 30 women) between the ages of 21-51. The 50th percentile score for adult Chinese female's lifting strength was 17.71% lower than the American female while the adult Chinese male's lifting strength was 14.94% lower than the American male. Lifting forces were higher in the 20-40 year age group. The isometric work mode had considerable impact on the lifting capacities, with shoulder level having the highest lifting capacities. The gender and body weight had a significant positive correlation to lifting capacity while job physical demand had a moderate correlation. Age and body heights were weakly correlated to lifting capacity.

Adult↗

Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate--a biomechanical study in a cadaveric model.

The stability of palmar plate fixation using a locking compression T-plate was compared with that of a conventional palmar T-plate and a dorsal T-plate in a cadaveric model of an AO type C2 fracture of distal radius. The wrist axial load transmission through the radius was tested for each fixation. The results show that, under 100N axial load, the palmar locking compression T-plate restores stability comparable to that of the intact radius, and is superior to conventional palmar or dorsal T-plates.

Biomechanical Phenomena↗

Controllable porosity hydroxyapatite ceramics as spine cage: fabrication and properties evaluation.

A procedure was designed to prepare porosity-graded hydroxyapatite (HA) ceramics simulating the bimodal structure of natural bone, which could be used to build a cage that would promote the reconstruction of the anterior column after vertebrectomy or corpectomy in tumor and trauma surgery. HA ceramics with controllable pore size distribution and porosity were developed by using chitosan and Poly(vinyl alcohol) (PVA) as the pore-forming agents. HA ceramics with worthwhile properties such as a wide range of volume porosity (10-50%) and pore size (nanometer to 400 microm) can be obtained from this method, which allows the fabrication of HA ceramics with desirable porous characteristics simulating the bimodal natural bone architecture expected to provide advantages for bony fusion in the intervertebral foramina. When coated with chitosan-gelatin network, the bending strength of the porous HA ceramics significantly improved. The polymer network coated porous HA have potential application in the construction of cages for spinal operations.

Journal Article↗

Gene therapy for new bone formation using adeno-associated viral bone morphogenetic protein-2 vectors.

Previous reports have suggested that bone morphogenetic protein (BMP) gene therapy could be applied for in vivo bone regeneration. However, these studies were conducted either using immunodeficient animals because of immunogenicity of adenovirus vectors, or using ex vivo gene transfer technique, which is much more difficult to handle. Adeno-associated virus (AAV) is a replication-defective virus without any association with immunogenicity and human disease. This study was conducted to investigate whether orthotopic new bone formation could be induced by in vivo gene therapy using AAV-based BMP2 vectors. To test the feasibility of this approach, we constructed an AAV vector carrying human BMP2 gene. Mouse myoblast cells (C2C12) transduced with this vector could produce and secrete biologically active BMP2 protein and induce osteogenic activity, which was confirmed by ELISA and alkaline phosphatase activity assay. For in vivo study, AAV-BMP2 vectors were directly injected into the hindlimb muscle of immunocompetent Sprague-Dawley rats. Significant new bone under X-ray films could be detected as early as 3 weeks postinjection. The ossification tissue was further examined by histological and immunohistochemical analysis. This study is, to our knowledge, the first to establish the feasibility of AAV-based BMP2 gene therapy for endochondral ossification in immunocompetent animals.

Animals↗

Application of time-frequency analysis to somatosensory evoked potential for intraoperative spinal cord monitoring.

OBJECTIVE: To investigate the improvement in the reliability of intraoperative spinal cord monitoring by applying time-frequency analysis to somatosensory evoked potentials (SEP). METHODS: 34 patients undergoing scoliosis surgery were studied. SEP were recorded during different stages of scoliosis surgery. Averaged SEP signals were analysed intraoperatively by short time Fourier transform (STFT). The time-frequency characteristics of SEP were observed during surgery. The main peak in the time-frequency interpretation of SEP was measured in peak time, peak frequency, and peak power. The changes in these variables were compared with the changes in latency and amplitude during different surgical stages. RESULTS: During different surgical stages, changes in peak times and peak powers were found to correlate with the changes in latency and amplitude, respectively. Peak time showed more variability than latency (p < 0.01), while peak power showed less variability than amplitude (p < 0.01). The peak frequency of SEP appeared to be unchanged during surgery. SEP signals were found to have specific time-frequency characteristics, with the time-frequency distribution of the signals being located in a particular time-frequency space. CONCLUSIONS: Time-frequency analysis of SEP waveforms reveals stable and easily identifiable characteristics. Peak power is recommended as a more reliable monitoring parameter than amplitude, while peak time monitoring was not superior to latency measurement. Applying time-frequency analysis to SEP can improve the reliability of intraoperative spinal cord monitoring.

Adolescent↗

A comparison of deconvolution techniques for stress relaxation.

Stress relaxation (or equivalently creep) allows a large range of the relaxation (retardation) spectrum of materials to be examined, particularly at lower frequencies. However, higher frequency components of the relaxation curves (typically of the order of Hertz) are attenuated due to the finite time taken to strain the specimen. This higher frequency information can be recovered by deconvolution of the stress and strain during the loading period. This paper examines the use of three separate deconvolution techniques: numerical (Fourier) deconvolution, semi-analytical deconvolution using a theoretical form of the strain, and deconvolution by a linear approximation method. Both theoretical data (where the exact form of the relaxation function is known) and experimental data were used to assess the accuracy and applicability of the deconvolution methods. All of the deconvolution techniques produced a consistent improvement in the higher frequency data up to the frequencies of the order of Hertz, with the linear approximation method showing better resolution in high-frequency analysis of the theoretical data. When the different deconvolution techniques were applied to experimental data, similar results were found for all three deconvolution techniques. Deconvolution of the stress and strain during loading is a simple and practical method for the recovery of higher frequency data from stress-relaxation experiments.

Algorithms↗

Bioactive bone cement as a principal fixture for spinal burst fracture: an in vitro biomechanical and morphologic study.

STUDY DESIGN: An in vitro biomechanical and radiographic study to evaluate the properties of a newly developed bioactive bone cement for stabilization of the fractured spine, suitable for minimally invasive application. OBJECTIVES: To determine the mechanical stability of the fractured spine after injection of the newly developed bioactive bone cement under quasi-static and cyclic loading regimens. SUMMARY OF BACKGROUND DATA: Bone cement injection has been reported as a potentially useful, minimally invasive technique for treating vertebral body fracture or stabilizing osteoporosis. However, potential problems associated with the use of polymethylmethacrylate (PMMA) have prompted the search for alternative solutions. The use of bioactive bone cement as a potential replacement for PMMA has been reported. METHODS: Biomechanical and radiographic analyses were used to test the mechanical stability of the fractured spine. The cement used was formed from hydroxyapatite powder containing strontium and bisphenol A diglycidylether dimethacrylate (D-GMA) resin. Twenty-six fresh porcine spine specimens (T10-L1) were divided into three groups: pilot, intact, and cemented. Spinal stiffness and failure strength were recorded in the intact group with the specimens flexed at 10 degrees. Uniform injuries were created in all specimens of the cemented group, and compressive loading was applied with 10 degrees of flexion until a fracture occurred. The bone cement was injected into the fractured spine, and stiffness was evaluated after 1 hour. Failure strength was also recorded after 3000 and 20,000 fatigue load cycles. Morphology of the specimens was observed and evaluated. RESULTS: Results from a cell biocompatibility test indicated that the new bioactive bone cement was favorable for cell growth. Spinal stiffness significantly decreased after fracture (47.5% of intact condition). Instant stiffness of the spine recovered to 107.8% of the intact condition after bone cement injection. After 3000 and 20,000 cycles of fatigue loading, stiffness of the cemented spine was found to be 93.5% and 94.4% of intact stiffness, respectively (P < 0.05). Average failure strength of the spine was 5056 N (after 3000 cycles) and 5301 N (after 20,000 cycles) after bone cement injection and fatigue loading. Radiographs and cross-sectional observations indicated a good cement-bone bonding and fracture fill. CONCLUSIONS: A new bioactive bone cement without cytotoxic effect has been developed. Results show that minimally invasive techniques to apply this cement to porcine spines results in augmentation of mild burst fractures such that the original stiffness and strength of the vertebra are recovered. This new cement therefore shows potential as an augmentation to traditional instrumentation in the surgical management of vertebral fractures. The potential for further clinical applications is currently under investigation.

Animals↗

Comparison of time-frequency distribution techniques for analysis of spinal somatosensory evoked potential.

Spinal somatosensory evoked potential (SSEP) has been employed to monitor the integrity of the spinal cord during surgery. To detect both temporal and spectral changes in SSEP waveforms, an investigation of the application of time-frequency analysis (TFA) techniques was conducted. SSEP signals from 30 scoliosis patients were analysed using different techniques; short time Fourier transform (STFT), Wigner-Ville distribution (WVD), Choi-Williams distribution (CWD), cone-shaped distribution (CSD) and adaptive spectrogram (ADS). The time-frequency distributions (TFD) computed using these methods were assessed and compared with each other. WVD, ADS, CSD and CWD showed better resolution than STFT. Comparing normalised peak widths, CSD showed the sharpest peak width (0.13+/-0.1) in the frequency dimension, and a mean peak width of 0.70+/-0.12 in the time dimension. Both WVD and CWD produced cross-term interference, distorting the TFA distribution, but this was not seen with CSD and ADS. CSD appeared to give a lower mean peak power bias (10.3%+/-6.2%) than ADS (41.8%+/-19.6%). Application of the CSD algorithm showed both good resolution and accurate spectrograms, and is therefore recommended as the most appropriate TFA technique for the analysis of SSEP signals.

Evoked Potentials, Somatosensory↗

Effect of stimulus pulse duration on intraoperative somatosensory evoked potential (SEP) monitoring.

The effect of the stimulus duration on the amplitude and latency of intraoperative somatosensory evoked potential (SEP) was studied in 30 patients with idiopathic scoliosis undergoing surgery. Constant current square-wave electrical stimulation was applied to the posterior tibial nerve at a rate of 5.1 Hz. The effects of both the pulse duration and the stimulus current density on the intraoperative SEP were evaluated. Amplitudes and latencies of SEP were analyzed by one-way parametric analysis of variance. SEP signal recording was found to be difficult if the stimulus duration was less than 0.05 ms. The stimulus duration had no significant effect on the latencies of the SEP, but the amplitude of the SEP showed significant changes with differing stimulus durations. The SEP amplitudes were found with significant increases in pulse durations less than 0.3 ms. Stimulus pulse duration has a significant effect on SEP amplitude, and this should be taken into consideration during intraoperative SEP monitoring. A pulse duration of 0.3 ms is recommended for SEP using posterior tibial nerve stimulation.

Adolescent↗

Back muscle contraction patterns of patients with low back pain before and after rehabilitation treatment: an electromyographic evaluation.

The aims of this study were to conduct a comparative investigation of muscle function between patients with low back pain (LBP) and healthy persons, and to determine whether intensive rehabilitation can change back muscle contraction synergy. Twenty healthy persons and 20 patients with chronic LBP were asked to perform symmetrical and asymmetric tasks. The patients with LBP were tested in the weeks immediately before and after 12 weeks of LBP rehabilitation. Tasks include "carrying" weights up and down and with a 45 degrees left rotation. Eight-channel surface electromyographic electrodes were placed on the surface of paraspinal muscles over the lumbar region. Correlations between the right and left corresponding muscles and between values before and after treatment were determined. Lifting capacity for patients with LBP were also measured before and after treatment. Results from electromyographic profiles showed that the muscle activity strategies varied between healthy persons and patients with LBP. The correlation coefficients for spinal muscles have shown very reproducible intrasubject muscle contraction synergies. Unbalanced electromyographic patterns found in patients with LBP given symmetrical tasks were not affected by rehabilitation treatment.

Adult↗

Effect of stimulation parameters on intraoperative spinal cord evoked potential monitoring.

The purpose of this study was to investigate the effects of the stimulus parameters on spinal cord evoked potential (SCEP) and to recommend a practical epidural stimulation protocol for intraoperative spinal cord monitoring. This prospective study compared the latencies and amplitudes of SCEP obtained on epidural stimulation of 30 patients with scoliosis under anesthesia using different stimulus pulse duration and stimulation rates. SCEP was found to be undetectable with shorter stimulus duration (<0.05 ms). The SCEP latencies did not show any significant difference among different stimulation parameters. However, the SCEP amplitude showed significant changes with differing stimulus durations. The SCEP amplitudes were found to significantly decrease when the pulse durations become shorter than 0.2 ms. Stimulus parameters showed significant effects on SCEP amplitude but not latency. Stimulus rates in the range of 21 to 61 Hz are equivalent for quick and reliable detection of SCEP. Considering the short latency of SCEP, a pulse duration of 0.2 ms is recommended for SCEP using epidural stimulation.

Adolescent↗