Visual symptoms after lung transplantation: a case of progressive multifocal leukoencephalopathy.

After solid organ transplantation, signs and symptoms of the central nervous system may present a diagnostic challenge. A 43-year-old patient developed a decrease in vision 15 months after bilateral lung transplantation. The initial diagnosis was a left posterior cataract, but left eye cataract extraction did not improve his vision. Seizures led to investigation of a broader differential diagnosis (cyclosporine intoxication, post-transplant lymphoproliferative disorder, infectious disease, chronic lymphatic leukemia). The clinical diagnosis of progressive multifocal leukoencephalopathy (PML) was confirmed by demonstration of JC virus in the cerebrospinal fluid and by autopsy findings. Modulation of the immunosuppressive regimen was unsuccessful. This case illustrates that decreased vision in immunocompromised patients may be the first manifestation of PML.

Adult↗

Airway inflammation and hyperresponsiveness to adenosine 5'-monophosphate in chronic obstructive pulmonary disease.

BACKGROUND: Chronic obstructive pulmonary disease (COPD) is often accompanied by bronchial hyperresponsiveness (BHR). Measurement of BHR may give information about airway inflammation. OBJECTIVE: To investigate the role of airway inflammation in hyperresponsiveness to adenosine 5'-monophosphate (AMP) in COPD. METHODS: We investigated inflammatory indices in induced sputum, bronchoalveolar lavage (BAL) fluid and bronchial biopsies in subjects with COPD with and without hyperresponsiveness to AMP. Twelve nonatopic subjects with COPD with hyperresponsiveness to AMP (mean +/- SD, age 63 +/- 8 years, FEV1% predicted 56 +/- 13%), six without BHR (age 60 +/- 6 years, FEV1% predicted 65 +/- 11%) and 11 healthy nonatopic controls without BHR (age 58 +/- 8 years, FEV1% predicted 104 +/- 11%) participated in the study. RESULTS: Subjects with COPD with BHR had significantly higher numbers of mucosal CD8 + and higher percentages of sputum eosinophils than those without BHR (median, 550 cells/mm2; range, 30-1340 vs 280 cells/mm2; range, 110-450, P = 0.045; and median, 2.7%; range, 0.5-8.5 vs 0.6%; range, 0-0.8 %, P = 0.0036, respectively). No differences were observed in BAL fluid. CONCLUSION: We conclude that hyperresponsiveness to AMP in COPD is associated with airway inflammation that is characterized by increased numbers of mucosal CD8 + cells and percentages of sputum eosinophils. Hyperresponsiveness to AMP may be used as a marker of airway inflammation in COPD, but its significance in the clinical course remains to be determined.

Adenosine Monophosphate↗

Ongoing airway inflammation in patients with COPD who do not currently smoke.

BACKGROUND: Inflammatory changes in the airways in chronic obstructive pulmonary disease (COPD) are largely attributed to smoking, yet they may be present even if patients do not currently smoke. The differences in inflammatory cells and the factors contributing to these differences were examined in the airways of patients with COPD who do not currently smoke. METHODS: Eighteen non-atopic subjects with COPD (14 men) of mean (SD) age 62 (8) years and forced expiratory volume in one second (FEV(1)) 59 (13)% predicted and 11 non-atopic healthy subjects (eight men) of mean (SD) age 58 (8) years, FEV(1) 104 (11)% predicted were studied. Sputum induction and bronchoscopy with bronchoalveolar lavage (BAL) and biopsies were performed. RESULTS: Patients with COPD had more mucosal EG2+ cells (eosinophils) (median (range) 40 (0-190) versus 5 (0-40) cells/mm(2), p = 0.049) and CD68+ cells (1115 (330-2920) versus 590 (450-1580) cells/mm(2), p = 0.03), and a tendency towards more CD4+ but not CD8+ lymphocytes than healthy controls. Furthermore, patients with COPD had higher percentages of sputum neutrophils (77 (29-94) versus 36 (18-60)%, p = 0.001) and eosinophils (1.2 (0-8.5) versus 0.2 (0-3.1)%, p = 0.008), BAL fluid eosinophils (0.4 (0-1.7) versus 0.2 (0-0.5)%, p = 0.03), and higher concentrations of sputum eosinophilic cationic protein (ECP) (838 (115-23 760) versus 121 (35-218) ng/ml, p<0.001). Concentrations of ECP expressed per eosinophil were not higher. Patients with COPD with high mucosal EG2+ cell numbers also had high mucosal CD4+ cell numbers. Sputum eosinophilia was associated with a decrease in FEV(1)/VC and BAL fluid eosinophilia with a decrease in mucosal NP57+ cells (neutrophils). CONCLUSIONS: Subjects with COPD who do not currently smoke have increased numbers of inflammatory cells. Eosinophils are increased in number in the airways in COPD but do not seem to be activated. The increased eosinophil numbers are probably due to recruitment as a result of ongoing inflammation. Macrophages and lymphocytes may play a part in this inflammation.

Biopsy↗

Eosinophilic granulocytes and interleukin-6 level in bronchoalveolar lavage fluid are associated with the development of obliterative bronchiolitis after lung transplantation.

In a prospective cohort study, we assessed whether changes in total cell counts and differentiation and interleukin-6 (IL-6), IL-8, and monocyte chemoattractant protein-1 (MCP-1) concentrations in bronchoalveolar lavage fluid (BALF) are associated with a higher risk to develop obliterative bronchiolitis (OB). We investigated 60 lung transplant patients (follow-up of 2 to 8 yr) with either histologic evidence of OB within 1 yr after lung transplantation (n = 19) or no pathology, good outcome (GO) for at least 24 mo and well-preserved lung function, i.e., FEV > or = 80% of baseline (n = 41). Median time between lung transplantation and the first BAL was 42 d for the GO group and 41 d for the OB group (p > 0.05). In the bronchial fraction, median total cell counts (0.06 x 10(3)/ml versus 0.04 x 10(3)/ml), lymphocyte (9 x 10(3)/ml versus 2 x 10(3)/ml), and eosinophilic granulocyte counts (1 x 10(3)/ml versus 0) were significantly higher in the OB group than in the GO group (p < 0.05). In the alveolar fraction, this was the case for the median value of neutrophilic granulocyte counts (19 x 10(3)/ml versus 4 x 10(3)/ml), respectively. Median values of IL-6 and IL-8 concentrations in both bronchial (IL-6: 23 versus 6 pg/ml, IL-8: 744 versus 102 pg/ml) and alveolar fractions (IL-6: 13 versus 3 pg/ml, IL-8: 110 versus 30 pg/ml) of the BALF were significantly higher in the OB group than in the GO group. By means of logistic regression, we showed that higher total cell, neutrophilic granulocyte, and lymphocyte counts, the presence of eosinophilic granulocytes, and higher concentrations of IL-6 and IL-8 were significantly associated with an increased risk to develop OB. We conclude that monitoring cell counts, neutrophilic and eosinophilic granulocytes, IL-6, and IL-8 in BALF within 2 mo after lung transplantation in addition to the transbronchial lung biopsy (TBB) pathology will contribute to a better identification and management of the group of patients at risk for developing OB within a year.

Adult↗

Comparison of induced sputum with bronchial wash, bronchoalveolar lavage and bronchial biopsies in COPD.

It is unclear how cellular and soluble inflammatory markers in induced sputum relate to markers in lavage fluid and biopsies in chronic obstructive pulmonary disease (COPD). This was investigated and also the possible differences between subjects with COPD and healthy controls assessed. Eighteen nonatopic subjects with COPD and 11 healthy controls were studied. Sputum was induced by inhalation of hypertonic saline. The airways were lavaged, using the first 50 mL for bronchial wash (BW) and the subsequent 150 mL for bronchoalveolar lavage (BAL), and biopsies were taken from subsegmental carinae. Neutrophils were the predominant cell type in sputum in COPD (median 77.3%) but not in BW (5.5%) and BAL fluid (1.7%). Differential cell counts in sputum did not correlate with the counts in BW or BAL fluid or biopsies, whereas sputum eosinophil cationic protein (ECP) levels correlated with BW fluid ECP levels (p=0.66, p=0.007) and sputum interleukin-8 (IL-8) concentration with BAL fluid IL-8 concentration (p= 0.52, p=0.026). Subjects with COPD had a higher percentage of sputum neutrophils and eosinophils and higher concentrations of ECP and IL-8 than healthy controls. The higher percentages of eosinophils and concentrations of ECP were also seen in BW and BAL fluid. Finally, higher numbers of macrophages and eosinophils were found in biopsies. In conclusion, induced sputum is derived from a different compartment from BW and BAL fluid and biopsies. Induced sputum may be useful for studying the contribution of luminal neutrophils and eosinophils in chronic obstructive pulmonary disease.

Adult↗

[Survival and impact of bronchiolitis obliterans syndrome after lung transplantation at the Academic Hospital Groningen, 1990/'98].

OBJECTIVE: To describe the results of the lung transplantation programme in Groningen in relation to the bronchiolitis obliterans syndrome (BOS), in the first 118 consecutive patients. DESIGN: Retrospective. METHOD: Data were collected on the 118 patients subjected to lung transplantation in November 1990 to June 1998 in the University Hospital Groningen, the Netherlands, regarding the prevalence of chronic transplant dysfunction (BOS) and survival. RESULTS: 117 lung transplantations (95 bilateral lung transplantations including 2 retransplants, and 22 single lung transplantations) and 1 heart-lung transplantation had been performed. The patients were 70 males and 48 females with a mean age of 42 years (range: 9-64). The mean (SD) survival at 1, 2, 3 and 5 years post transplantation was 83% (3), 70% (4), 66% (5) and 61% (5) respectively. The median survival amounted to 2447 days. The mean (SD) prevalence of BOS at respectively 1, 2, 3 and 5 years post transplantation was 32% (5), 36% (5), 44% (5) en 54% (6). After a diagnosis of BOS stage I the median survival was 649 days. CONCLUSION: The survival of the lung transplant programme of the University Hospital Groningen is considered to compare favourably with other centres. The prevalence of BOS is considerable, and comparable with the prevalence of BOS reported by other programmes. BOS is associated with a decreased life expectancy.

Academic Medical Centers↗

The short and long term effects of intraoperative electron beam radiotherapy (IORT) on thoracic organs after pneumonectomy an experimental study in the canine model.

PURPOSE: The tolerance of mediastinal structures and thoracic organs to intraoperative radiotherapy (IORT) was investigated in the canine model. METHODS AND MATERIALS: Twenty-two adult beagles divided into three groups were subjected to a left pneumonectomy and IORT (10 MeV electrons) at doses of 20 Gy (n = 9), 25 Gy (n = 4), or 30 Gy (n = 9). Intraoperative electron beam radiotherapy was delivered through a 5 cm circular lucite cone encompassing a mediastinal field including the bronchial stump, aorta, esophagus, heart, phrenic nerve, contralateral hilar structures, and lung. Clinical monitoring was performed with regular chest X-ray, ECG, bronchoscopy, esofagoscopy, and fluoroscopy. From the different treatment dose groups, dogs were electively sacrificed at 1.5, 6, 12, and 72 months with complete autopsies. RESULTS: There was no bronchial stump dehiscence or acute morbidity. Four dogs developed radiation induced esophagitis (18%), one in the 20 Gy IORT group (11%) and three in the 30 Gy IORT group (33%). There were six IORT related mortalities (27.5%), one esophagoaortic fistula (4.5%) and five bronchovascular fistulas (23%): two in the 20 Gy IORT group (22%), two in the 25 Gy IORT group (50%) and two in the 30 Gy IORT group (22%). Histopathological findings in uncomplicated follow-up showed marked myointimal fibrosis in the muscular arteries, submucosal fibrosis of the esophagus, and interstitial fibrosis of bronchial and lung tissue, especially in the higher dose group. CONCLUSION: The mediastinal vascular, bronchial and esophageal structures are relatively sensitive to doses > 20Gy IORT. The IORT related morbidity found in this study may be lower when the current clinically used IORT doses of 10-15 Gy are applied. Further clinical application of IORT in the future treatment strategies for resectable nonsmall cell lung cancer may be worthwhile to investigate.

Animals↗

[Primary sarcoma of A. pulmonalis: a rare cause of cor pulmonale].

A 64-year-old female presented with fever and weight loss, accompanied by normochromic normocytic anaemia with high erythrocyte sedimentation rate. She developed severe cor pulmonale. Ventilation-perfusion scintigraphy revealed a non-matched perfusion defect of the entire right lung with impaired perfusion on the left side. The CT scan of the thorax revealed an intravascular mass which completely blocked the right pulmonary artery with incomplete obstruction of the pulmonary trunk. Treatment with anticoagulants was started but failed. The presumably thrombotic mass was removed by thoracotomy; the histopathological diagnosis was: sarcoma of the pulmonary artery, incompletely resected. Postoperatively, the condition of the patient showed initial improvement, but she later developed fatal mediastinitis. Pulmonary artery sarcoma is a rare cause of cor pulmonale. Diagnosis is usually only established at operation, curative resection is uncommon and the prognosis is therefore poor--most patients die within months after the diagnosis has been made.

Diagnosis, Differential↗

[Nitric oxide and asthma].

Nitric oxide (NO) is a universal signalling molecule, involved in many physiological and pathophysiological processes, including asthmatic airway inflammation. Nitric oxide synthases (NOS) are newly identified enzyme systems active in airway epithelial cells, macrophages, neutrophils, mast cells, non-adrenergic non-cholinergic neurons, smooth muscle cells and endothelial cells. Two functional classes of NOS can be identified: the inducible form temporarily leading to large amounts of NO, and the constitutive form continuously leading to small amounts of NO. Large amounts of NO contribute to airway inflammation and killing of micro-organism, whereas small amounts of NO lead to smooth muscle relaxation. Asthmatic airway obstruction is induced by various bronchoconstricting factors (like allergens, pharmacological spasmogens, physical stimuli, infectious disease state) and is inhibited by NO. The development of specific inhibitors for the inducible form of NOS might open up a new era of antiasthmatic drugs.

Asthma↗

Spleen autotransplantation provides restoration of functional splenic lymphoid compartments and improves the humoral immune response to pneumococcal polysaccharide vaccine.

After splenectomy, patients have an increased risk of overwhelming post-splenectomy infection (OPSI) or sepsis involving encapsulated bacteria such as pneumococcus. The value of spleen autotransplantation after splenectomy because of trauma has long been questioned. Much attention has been given to the restoration of mononuclear phagocyte system (MPS) function, which appeared to be similar to that of splenectomized individuals. The presence of specific anti-pneumococcal antibodies may enhance phagocytosis of opsonized bacteria by other parts of the MPS, as present in the liver. Therefore, in the present study we have evaluated the restoration of the humoral immune response after spleen autotransplantation, especially to pneumococcal capsular polysaccharides (PPS). Wistar rats were divided into three groups which were operated as follows: splenectomy, splenectomy followed by autotransplantation, and sham operation. After 12 weeks the rats were vaccinated with 23-valent pneumococcal vaccine. Blood samples were taken after 3 days, 3 and 6 weeks for anti-PPS IgM and IgG ELISA against types 3, 4, 6, 9, 14 and 23. In addition, immunohistological studies were performed on the autotransplants. Significant antibody titre rises were found in a main proportion of the autotransplanted rats, comparable to sham-operated rats. Splenectomized rats showed as well a significantly lower increase in immunoglobulin levels, as significant differences in the proportion of rats showing a minimum two-fold increase of antibody level, considered to represent an adequate response. The titres were highest 3 days after vaccination. Immunohistochemical studies demonstrated structurally functional autotransplants, including an intact marginal zone. Considering this significant anti- pneumococcal antibody response, spleen autotransplants can be expected to enable an improved humoral response to PPS, and to contribute to protection against OPSI after splenectomy.

Animals↗

Immune response capacity after human splenic autotransplantation: restoration of response to individual pneumococcal vaccine subtypes.

OBJECTIVE: To evaluate features of general immune function, in particular the restoration of the humoral immune response to pneumococcal capsular polysaccharides, in humans undergoing a spleen autotransplantation after splenectomy because of trauma. SUMMARY BACKGROUND DATA: After splenectomy, patients have an increased risk of overwhelming infection or sepsis involving encapsulated bacteria such as pneumococci. The value of human spleen autotransplantation after splenectomy because of trauma has long been questioned. Mononuclear phagocyte system function appeared to be similar to that in splenectomized persons. The presence of specific antipneumococcal antibodies would allow other parts of the mononuclear phagocyte system, such as those in the liver, to phagocytose opsonized bacteria. METHODS: Ten consecutive patients undergoing splenectomy followed by autotransplantation were compared with the next 14 consecutive patients undergoing splenectomy alone. After a minimum of 6 months, the patients were vaccinated with 23-valent pneumococcal vaccine. Blood samples were taken at the time of vaccination and after 3 and 6 weeks for antipneumococcal capsular polysaccharides IgM and IgG enzyme-linked immunosorbent assay against types 3, 4, 6, 9, 14, and 23. Splenic regrowth was evaluated by scintigraphy. RESULTS: Surprisingly, several of the nonautotransplanted patients showed scintigraphic activity, indicating the presence of either accessory spleens or traumatic seeding (splenosis). Significant antibody titer increases (more than twofold) were found for both IgM and IgG in the autotransplanted patients. Splenectomized-only patients showed no significant increase in Ig levels in patients without splenic regrowth and partial improvement in patients with splenosis/accessory spleens. CONCLUSIONS: Considering this significant antipneumococcal antibody increase, spleen autotransplants can be expected to permit an adequate humoral response to pneumococcal infections and presumably also to other TI-2 antigens, and to protect against overwhelming postsplenectomy infection or sepsis.

Adolescent↗

Markers of nitric oxide metabolism in sputum and exhaled air are not increased in chronic obstructive pulmonary disease.

BACKGROUND: Nitric oxide (NO) is involved in inflammation and host defence of the lung. It has been found in increased concentrations in the airways in asthmatic subjects but its levels in patients with chronic obstructive pulmonary disease (COPD) have not been investigated. A study was undertaken to determine whether markers of NO metabolism (NO in exhaled air, iNOS expression in sputum cells, and nitrite + nitrate (NO2-/NO3-) in sputum supernatant) are increased in subjects with COPD, and whether they correlate with inflammatory indices in induced sputum. The associations of these markers with smoking were also assessed. METHODS: Sixteen subjects with COPD (median age 66 years, median forced expiratory volume in one second (FEV1) 63% predicted, eight current smokers) and 16 healthy subjects (median age 63 years, median FEV1 113% predicted, eight current smokers) participated in the study. NO was measured during tidal breathing and sputum was induced by inhalation of hypertonic saline. RESULTS: No differences were observed between subjects with COPD and healthy controls in exhaled NO excretion rate (median 5.15 and 6.25 nmol/min), sputum macrophage iNOS expression (14% and 12%), and sputum supernatant NO2-/NO3- (46 and 73 microM). NO in exhaled air correlated with the percentage of sputum eosinophils in patients with COPD (rho = 0.65, p = 0.009) but not in healthy individuals. Exhaled NO and supernatant NO2-/NO3- levels were lower in healthy smokers than in healthy non/ex-smokers. CONCLUSIONS: Our findings indicate that NO metabolism is not increased in patients with stable COPD. The close association between exhaled NO levels and sputum eosinophils suggests a role for NO in airway inflammation in COPD. Studies performed during exacerbations may clarify this role.

Aged↗

The relationship of skin test positivity, high serum total IgE levels, and peripheral blood eosinophilia to symptomatic and asymptomatic airway hyperresponsiveness.

The relationships of skin test positivity, high serum total IgE levels (> 100 kU/L), and peripheral blood eosinophilia (>/= 275 cells/microliter) to symptomatic (either chronic cough, chronic phlegm, bronchitis episodes, dyspnea, wheeze, or asthma) and asymptomatic bronchial hyperresponsiveness (BHR) were studied cross-sectionally in 620 adult subjects who participated in the Vlagtwedde-Vlaardingen Study of 1989 and 1990. Eosinophilia (OR = 2.06, 95% CI = 1.28 to 3.31) and skin test positivity (OR = 1.66, 95% CI = 1.02 to 2.71) were both significantly associated with BHR independent of age, sex, smoking, and urban area of residence. High serum total IgE levels were not associated with BHR (OR = 1.29, 95% CI = 0.81 to 2.03). Separate analyses for symptomatic and asymptomatic subjects showed that the higher risk of BHR with skin test positivity applied only to symptomatic subjects (OR = 5.78, 95% CI = 1.63 to 20.51), independent of eosinophilia and high serum total IgE levels. The higher risk of BHR with eosinophilia was not different between symptomatic and asymptomatic subjects, and independent of skin test positivity and high serum total IgE levels. The results of this study show that, in the general adult population, eosinophilia is associated with BHR both in symptomatic and asymptomatic persons, whereas skin test positivity is associated with BHR only in symptomatic subjects.

Adult↗

Smoking and airway hyperresponsiveness especially in the presence of blood eosinophilia increase the risk to develop respiratory symptoms: a 25-year follow-up study in the general adult population.

Airway hyperresponsiveness (AHR) constitutes a risk for development of respiratory symptoms. We assessed whether blood eosinophilia (>/= 275 eosinophils/microliters), skin test positivity (sum score >/= 3) and cigarette smoking (never, ex-smoker, 1-14 cig/d, 15-24 cig/d, >/= 25 cig/d) at the first of two successive surveys are related to the development of respiratory symptoms (chronic cough or phlegm, bronchitis, persistent wheeze, dyspnea, and asthma) at the second survey, and whether these relations are the same in subjects with (PC10 </= 8 mg/ml histamine) and without AHR. We analyzed data of the longitudinal Vlagtwedde-Vlaardingen Study (1965 to 1990) using logistic regression analyses with paired observations, taking multiple measurements within a person into account. In total, 995 men and 792 women contributed 4,403 paired observations. Eosinophilia in hyperresponsive subjects significantly increased the risk to develop one or more respiratory symptoms (odds ratio [OR] = 3.67, 95% confidence interval [CI] = 1.79 to 7.52), wheeze (OR = 5. 06, 95% CI = 2.11 to 12.13), and dyspnea (OR = 2.73, 95% CI = 1.13 to 6.60), independent of smoking, age, sex, area of residence, and time between two successive surveys. Smoking at the first of two successive surveys increased the risk to develop symptoms in a dose-dependent relation. Subjects with positive skin tests in the past were less likely to develop one or more respiratory symptoms (OR = 0.64, 95% CI = 0.46 to 0.88) and chronic phlegm (OR = 0.65, 95% CI = 0.42 to 1.00), independent of AHR. This longitudinal study in the general adult population shows that cigarette smoking and hyperresponsive subjects are at increased risk to develop respiratory symptoms, and especially so when eosinophilia is present in hyperresponsive persons.

Adolescent↗

Phase I study of transforming growth factor-beta3 mouthwashes for prevention of chemotherapy-induced mucositis.

The purpose of this study was to establish the safety and tolerability of recombinant transforming growth factor-beta3 (TGF-beta3; CGP 46614) mouthwashes intended for prevention of chemotherapy-induced mucositis. Local effects were especially analyzed by objective and subjective measurements of mucositis. Secondary aims were analysis of potential systemic exposure and development of anti-TGF-beta3-antibodies. Eleven breast cancer patients received chemotherapy with 1.5 g/m2 cyclophosphamide i.v., 80 mg/m2 epirubicin i.v., and 1.0 g/m2 5-fluorouracil i.v. (n = 8) or 1.6 g/m2 carboplatin i.v., 480 mg/m2 thiotepa i.v., and 6 g/m2 cyclophosphamide i.v. divided over 4 days (n = 3). TGF-beta3 mouthwashes (10 ml; provided by Novartis, Basel, Switzerland) were administered for 4 days, four times a day, starting 1 day before chemotherapy. The dose was escalated in following patients from 25 microg/ml (n = 3) to 50 microg/ml (n = 3) and 100 microg/ml (n = 5). Clinically, the mucosa was scored objectively and according to WHO criteria. The percentage of viable oral epithelial cells was determined by trypan blue dye exclusion. Morphology of cells was assessed in buccal smears. Plasma samples were collected for determination of TGF-beta3 levels and anti-TGF-beta3-antibodies. Adverse events were recorded by the patient in a diary. Mouthwashes with TGF-beta3 were well tolerated. Three patients scored for mucositis > grade 0 (WHO grading criteria). The percentage of viable oral epithelial cells in patients treated with 1.5 g/m2 cyclophosphamide i.v., 80 mg/m2 epirubicin i.v., and 1.0 g/m2 5-fluorouracil i.v. was stable, whereas in patients treated with 1.6 g/m2 carboplatin i.v., 480 mg/m2 thiotepa i.v., and 6 g/m2 cyclophosphamide i.v. divided over 4 days, an increase was observed. The morphology of buccal cells showed a transient shift from mature to immature cells in the first week. Neither systemic absorption of TGF-beta3 nor development of TGF-beta3-antibodies was observed. TGF-beta3 mouthwashes were well tolerated and deserve further study in preventing chemotherapy-induced mucositis.

Administration, Oral↗

Proteoglycan changes in the extracellular matrix of lung tissue from patients with pulmonary emphysema.

To characterize the changes in the extracellular matrix in smoking-related pulmonary emphysema, we undertook immunohistochemical studies in lung tissues from controls (n = 7), from patients with mild (n = 11) and severe (n = 8) emphysema, and from patients with lung fibrosis (n = 6). We studied collagens, laminin, fibronectin, proteoglycans (PGs), and beta1-integrins. The majority of the patients with severe emphysema showed diminished staining for the interstitial PGs, decorin and biglycan, in the peribronchiolar area, compared with patients in the control and fibrosis groups. Only a minority of patients with mild emphysema showed this diminished staining. In contrast, decorin and biglycan were well preserved in the perivascular area of all of the specimens from the emphysema group. Heparan sulfate PG staining was diminished in the respiratory airspace walls of patients with emphysema and fibrosis. Staining for Types I, III, and IV collagen, as well as for laminin, fibronectin, and the integrins, showed no differences between the four groups. The specific loss of interstitial PGs may be crucial for elastic recoil loss and subsequent bronchiolar obstruction, as seen in patients with smoking-related emphysema.

Adolescent↗