Search PubMed⌕ Search

Biomedical subjects

W Thomlinson

Publications and source records attributed to W Thomlinson.

16 recordsLinked to original sources

Effect of tidal volume on distribution of ventilation assessed by synchrotron radiation CT in rabbit.

A respiration-gated synchrotron radiation computed tomography (SRCT) technique, which allows visualization and direct quantification of inhaled stable xenon gas, was used to study the effect of tidal volume (Vt) on regional lung ventilation. High-resolution maps (pixel size 0.35 x 0.35 mm) of local washin time constants (tau) and regional specific ventilation were obtained in five anesthetized, paralyzed, and mechanically ventilated rabbits in upright body position at the fourth, sixth, and eighth dorsal vertebral levels with a Vt from 4.9 +/- 0.3 to 7.9 +/- 0.4 ml/kg (means +/- SE). Increasing Vt without an increase in minute ventilation resulted in a proportional increase of mean specific ventilation up to 65% in all studied lung levels and reduced the scattering of washin tau values. The tau values had log-normal distributions. The results indicate that an increase in Vt decreases nonuniformity of intraregional ventilatory gas exchange. The findings suggest that (SRCT) provides a new quantitative tool with high spatial discrimination ability for assessment of changes in peripheral pulmonary gas distribution during mechanical ventilation.

Animals↗

Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology.

Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

Breast Neoplasms↗

Medical applications of synchrotron radiation.

The medical imaging and therapeutic technologies that are based on the use of radiation are reviewed briefly, with special emphasis on the recent developments of synchrotron radiation (SR) methods. New results have been achieved in all of these areas since the last comprehensive reviews were written in this field. This topical review is intended to make the latest possible results and complete set of references available. The different contrast mechanisms in imaging by x-rays are described. The applications range from whole-body imaging to studies of atomic and molecular structures. The SR imaging applications include coronary angiography, bronchography, mammography, computed tomography, x-ray microscopy and imaging by scattering. The therapy applications include photon activation therapy and microbeam radiation therapy.

Animals↗

Small-angle x-ray scattering studies of human breast tissue samples.

Small-angle x-ray scattering (SAXS) patterns are recorded from thin breast tissue samples containing healthy and cancerous regions. The SAXS patterns are compared with histo-pathological observations. The information available from SAXS is reviewed, and a model for scattering from collagen is presented. Scattering patterns of collagen at regions far from the tumours are essentially different from those at tumours. The axial period of collagen fibrils is 65.0 +/- 0.1 nm in healthy regions, and 0.3 nm larger in cancer-invaded regions. The average intensity of scattering from cancerous regions is an order of magnitude higher than the intensity from healthy regions. This is interpreted to arise from an increase of the specific surface area of the scatterers, which is due to a disruption of the molecular and supra-molecular structures in cancerous regions and invasion of new types of cells. The differences of the SAXS patterns are large and distinctive enough to suggest that these phenomena may be utilized in mammography.

Breast↗

Diffraction enhanced imaging contrast mechanisms in breast cancer specimens.

We have investigated the contrast mechanisms of the refraction angle, and the apparent absorption images obtained from the diffraction enhanced imaging technique (DEI) and have correlated them with the absorption contrast of conventional radiography. The contrast of both the DEI refraction angle image and the radiograph have the same dependence on density differences of the tissues in the visualization of cancer; in radiography these differences directly relate to the contrast while in the DEI refraction angle image it is the density difference and thickness gradient that gives the refraction angle. We show that the density difference of fibrils in breast cancer as measured by absorption images correlate well with the density difference derived from refraction angle images of DEI. In addition we find that the DEI apparent absorption image and the image obtained with the DEI system at the top of the reflectivity curve have much greater contrast than that of the normal radiograph (x8 to 33-fold higher). This is due to the rejection of small angle scattering (extinction) from the fibrils enhancing the contrast.

Absorption↗

Lack of cell death enhancement after irradiation with monochromatic synchrotron X rays at the K-shell edge of platinum incorporated in living SQ20B human cells as cis-diamminedichloroplatinum (II).

In this paper we describe the results of experiments using synchrotron radiation to trigger the Auger effect in living human cancer cells treated with a widely used chemotherapy drug: cis-diamminedichloroplatinum (II) (cisplatin). The experiments were carried out at the ID17 beamline of the European Synchrotron Radiation Facility, which produces a high-fluence monochromatic beam that is adjustable from 20 to 80 keV. Cisplatin was chosen as the carrier of platinum atoms in the cells because of its alkylating-like activity and the irradiation was done with monochromatic beams above and below the platinum K-shell edge (78.39 keV). Cell survival curves were comparable with those obtained for the same cells under conventional irradiation conditions. At a low dose of cisplatin (0.1 microM, 48 h), no difference was seen in survival when the cells were irradiated above and below the K-shell edge of platinum. Higher cisplatin concentrations were investigated to enhance the cellular platinum content. The results with 1 microM cisplatin for 12 h showed no difference when the cells were irradiated with beams above or below the platinum K-shell edge with the exception of the higher cell death resulting from drug toxicity. The intracellular content of platinum was significant, as measured macroscopically by inductively coupled plasma mass spectrometry. Its subcellular localization and particularly its presence in the cell nucleus were verified by microscopic synchrotron X-ray fluorescence. This was the first known attempt at K-shell edge photon activation of stable platinum in living cells with a platinum complex used for chemotherapy. Its evident toxicity in these cells leads us to put forth the hypothesis that cisplatin toxicity can mask the enhancement of cell death induced by the irradiation above the K-shell edge. However, K-shell edge photon activation of stable elements provides a powerful technique for the understanding of the biological effects of Auger processes. Further avenues of development are discussed.

Calibration↗

Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent.

Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.

Administration, Inhalation↗

Fixed-exit monochromator for computed tomography with synchrotron radiation at energies 18-90 keV.

A fixed-exit monochromator has been constructed for computed tomography (CT) studies at the Medical Beamline of the European Synchrotron Radiation Facility. A non-dispersive pair of bent Laue-type crystals is used, and the first crystal is water-cooled. The monochromator operates at energies from 18 to 90 keV, and the maximum width of the beam is 150 mm. The performance of the monochromator is studied with respect to the beam intensity and energy distributions, and a close agreement is found between the calculated and experimental results. The intensity is between 10(9) and 10(10) photons s(-1) mm(-2) under typical operating conditions. The harmonic content of a 25 keV beam is about 30% at the minimum wiggler gap of 25 mm (field 1.57 T) and decreases by an order of magnitude when the gap is increased to 60 mm (field 0.62 T). The experimental set-up for CT studies includes dose monitors, goniometers and translation stages for positioning and scanning the object, and a 432-element linear-array Ge detector. Examples from phantom studies and in vivo animal experiments are shown to illustrate the spatial resolution and contrast of the reconstructed images.

Journal Article↗

First human transvenous coronary angiography at the European Synchrotron Radiation Facility.

The first operation of the European Synchrotron Radiation Facility (ESRF) medical beamline is reported in this paper. The goal of the angiography project is to develop a reduced risk imaging technique, which can be used to follow up patients after coronary intervention. After the intravenous injection of a contrast agent (iodine) two images are produced with monochromatic beams, bracketing the iodine K-edge. The logarithmic subtraction of the two measurements results in an iodine enhanced image, which can be precisely quantified. A research protocol has been designed to evaluate the performances of this method in comparison with the conventional technique. Patients included in the protocol have previously undergone angioplasty. If a re-stenosis is suspected, the patient is imaged both at the ESRF and at the hospital with the conventional technique, within the next few days. This paper reports the results obtained with the first patients. To date, eight patients have been imaged and excellent image quality was obtained.

Angioplasty, Balloon, Coronary↗

Research at the European Synchrotron Radiation Facility medical beamline.

The application of synchrotron radiation in medical research has become a mature field of research at synchrotron facilities worldwide. In the relatively short time that synchrotrons have been available to the scientific community, their characteristic beams of UV and X-ray radiation have been applied to virtually all areas of medical science which use ionizing radiation. The ability to tune intense monochromatic beams over wide energy ranges differentiates these sources from standard clinical and research tools. At the European Synchrotron Radiation Facility (Grenoble, France), a major research facility is operational on an advanced wiggler radiation beamport, ID17. The beamport is designed to carry out a broad range of research ranging from cell radiation biology to in vivo human studies. Medical imaging programs at ID17 include transvenous coronary angiography, computed tomography, mammography and bronchography. In addition, a major research program on microbeam radiation therapy is progressing. This paper will present a very brief overview of the beamline and the imaging and therapy programs.

Animals↗

In vivo K-edge imaging with synchrotron radiation.

We present in this paper two imaging techniques using contrast agents assessed with in vivo experiments. Both methods are based on the same physical principle, and were implemented at the European Synchrotron Radiation Facility medical beamline. The first one is intravenous coronary angiography using synchrotron radiation X-rays. This imaging technique has been planned for human studies in the near future. We describe the first experiments that were carried out with pigs at the ESRF. The second imaging mode is computed tomography using synchrotron radiation on rats bearing brain tumors. Owing to synchrotron radiation physical properties, these new imaging methods provide additional information compared to conventional techniques. After infusion of the contrast agent, it is possible to derive from the images the concentration of the contrast agent in the tumor area for the computed tomography and in any visible vessel for the angiography method.

Animals↗

Medical applications of diffraction enhanced imaging.

We have developed a new X-ray imaging technique, diffraction enhanced imaging (DEI), which can be used to independently visualize the refraction and absorption of an object. The images are almost completely scatter-free, allowing enhanced contrast of objects that develop small angle scattering. The combination of these properties has resulted in images of mammography phantoms and tissues that have dramatically improved contrast over standard imaging techniques. This technique potentially is applicable to mammography and other fields of medical X-ray imaging and to radiology in general, as well as possible use in nondestructive testing and X-ray computed tomography. Images of various tissues and materials are presented to demonstrate the wide applicability of this technique to medical and biological imaging.

Journal Article↗

Diffraction enhanced x-ray imaging.

Diffraction enhanced imaging is a new x-ray radiographic imaging modality using monochromatic x-rays from a synchrotron which produces images of thick absorbing objects that are almost completely free of scatter. They show dramatically improved contrast over standard imaging applied to the same phantom. The contrast is based not only on attenuation but also the refraction and diffraction properties of the sample. This imaging method may improve image quality for medical applications, industrial radiography for non-destructive testing and x-ray computed tomography.

Biophysical Phenomena↗

Monochromatic energy-subtraction radiography using a rotating anode source and a bent Laue monochromator.

A system for area-beam energy-subtraction monochromatic radiography was developed and tested. It utilizes a bent Laue crystal monochromator developed at the National Synchrotron Light Source (NSLS), and a compact rotating anode X-ray source developed at the Science Research Laboratory (SRL). The K(alpha) characteristic lines (both K(alpha 1) and K(alpha 2) of the cerium and barium targets were diffracted by the monochromator and used for the above- and below-K-edge imaging, respectively, of phantoms with iodine contrast agents. Digital subtraction of the images produced an iodine image.

Angiography, Digital Subtraction↗